Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.3 LAccepted-AOC | L1 | Accepted-AOC L1 Accepted | |
| 2 | L2₹15.5 L+₹18,919.50 (1.23%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹17.5 L+₹2.2 L (14.2%)Rejected-AOC 39 40 DASHMESH MARKET CIVIL GURUDWARA LINE PORT BLAIR 744 101 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | L3 | Rejected-AOC L3 | |
| 4 | L4₹19.5 L+₹4.2 L (27.3%)Rejected-AOC 00 KHATA NO 514 4357 PLOT NO 169 3484 KESHARA BHUBANESWAR KHURDA KHORDHA ODISHA 751007 | KHORDHA | ODISHA | 751007 | L4 | Rejected-AOC L4 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
14 Nov 2020, 6:00 pmClosed
GE GOLCONDA
GE GOLCONDA LANGERHOUSE OPP MILITARY HOSPITAL HYDERABAD TELANGANA
REPAIR REPLACEMENT MAINTENANCE OF LT EXTERNAL ELECT SUPPLY AND UG CABLES INCLUDING CONTROL PANELS AND OTHER ALLIED WORKS AT MH MD AREA UNDER GE GOLCONDA
2020_MES_386719_1
CA No. GE/Gol/Token 15 of 2020-2021
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE GOLCONDA
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE GOLCONDA
₹40,000
10 Apr 2021
15 Oct 2020
17 Nov 2020
15 Oct 2020
14 Nov 2020
29 Oct 2020
15 Oct 2020 - 27 Oct 2020
Amount
Note for item Nos 1 & 2 : (a) All existing incoming and out going cables are to be connected to the above panel with proper lugs, glands nuts, bolts etc which shall be deemed to include in the quoted rate. (b) The rate quoted by the contractor shall be deemed to be inclusive of demolition of concrete floors / cutting chases in walls, earth work excavation, PCC foundation etc, and making good the disturbed surfaces to match with the existing surfaces (c) The panel shall be fabricated from a reputed firm(CPRI Approved) .
S&F Steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolts, nuts, screws as specified type 410 SP-31(9.00 metre long) including two coats of bituminous paint internally and externally for the portion embedded in concrete and two coats of aluminium paint over one coat of red oxide primer to external/ exposed surfaces all as specified and directed. Note: (i) Rate quoted by the contractor shall deemed to includes excavation and earth work, 150mm thick PCC (1:3:6) type C2 (40mm graded stone aggregate below ploe and filled in trench up to 20cm above ground and coping concrete Shall be with PCC (1:2:4) type B1 20mm graded stone aggregate wth necessary formwork (iii) Rate quoted by the contractor shall also deemed to include for taking down carefully the exisitng unserviceable pole, serviceable street light fitting and ACSR conductor including connecting accessories and refixing the same after replacing the new pole with all necessary accessories complete all as specified and directed
S &L XLPE insulated and PVC sheathed heavy duty LT 1100 Volts grade armoured under ground cable, earthed with stranded aluminium conductor, laid in trenches/fixed to walls/poles etc., complete including taking down existing existing cable all as specified and directed for following sizes:- Note :- Earth work & excavation, sand cushioning and brick protection shall be measured and paid separately.
2 core 10 Sqmm
4 Core 16 Sqmm
3.5 Core 25 Sqmm
3.5 Core 35 Sqmm
3.5 Core 50 Sqmm
3.5 Core 70 Sqmm
3.5 Core 95 Sqmm
3.5 Core 120 Sqmm
3.5 Core 150 Sqmm
3.5 Core 185 Sqmm
3.5 Core 240 Sqmm
S & F Stel water tubing , light grade, galvanised as in cable protection at road crossing / on poles and tubing sealed at both ends after laying the cables complete all as specified and directed for the following sizes: -
100mm bore
80 mm bore
50 mm bore
S & F cable end termination jointing kit for 1.1 KV (earthed)grade cable for outdoor end termination heat shrinkable type joint with jointing material and accessories suitable to following sizes of cable complete including taking out old unserviceable one all as specified and directed.
35 Sqmm to 70 Sqmm
95 Sqmm to 150 Sqmm
185 Sqmm to 240 Sqmm
S and F cable jointing kit for 1.1 KV (Earthed) grade cable for outdoor termination heat shrinkable type straight through joint with jointing material and accessories suitable for 3.5 core cable for following sizes of cable complete including taking out old unserviceable one all as specified and directed.
35 sqmm to 70 sqmm
95 sqmm to150 sqmm
180 sqmm to 240 sqmm
S & F stringing of ACSR Conductor steel reinforced of type as directed including stretching, binding using ACSR conductor on insulator complete, on overhead line including taking down of existing conductor all as specified and directed.
Stringing only ACSR Conductor of type as directed including binding using ACSR conductor on insulator on overhead line, complete all as specified and directed .
S&F Stay assembly complete with accessories as shown in electric plate No.1 stay rod 16mm dia including loop type insulator, stay clamps, and also including excavation and earth work, PCC foundation etc., including taking out old unserviceable one all as specified and directed.
M&L Mild steel Cross arm bracing support clamps and back plates fabricated from structural steel sections including nuts, bolts and washers welding bending cold or hot drilling holes for bolts in any shape or sizes as indicated or directed inclusive of one coat of red oxide zinc chrome primer and two coats of aluminium paint, including taking down the existing cross arms etc complete all as specified and directed..
M&L Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two glavanised iron washers and one galvanised iron nut,100mm height, 65mm dia for 1100 Volts grade, including taking down existing insulators all as specifeid and directed.
M&L Shakle type, porcelain, vitreous, white brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts 100mm in height, 115mm dia, working pressure 1100 volts, section of strap 31X5, 14mm dia bolts including taking down the existing one etc complete all as specified and directed.
Cutting & trimming of tree branches any girth and size touching to overhead lines and cleaning the distance 1.5 mtr both sides of overhead line with in a gap of span 35 mtrs each and removing the same cleaning the site all as specified and directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth for foundation, laying of poles in trenches and getting out in hard/dense soil complete all as directed and specified.
Returning, filling including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick complete all as all as specified and directed.
Removal of surplus soil to a distance no exceeding 50 mtrs and depositing where directed at a lvevel not exceeding 1.5 mtrs above from the starting point complete all as all as specified and directed.
Supply and spread approved dry river sand for cable laying /foundations/Cable duct including watering and consolidation, cushioning of cable laid in trenches complete all as all as specified and directed. Note:- Punned thickness will be measured for payment purpose
M&L brick protection with common burnt bricks sub class ‘B’ of size 230 x 115 x 75mm laid in trenches for cable protection complete all as directed by Engineer-in-Charge.
M&L precast concrete cable cover, class LV, type 1 with peak, size 250mm x 150mm x 40mm laid in trenches as cable protection all as specified and directed.
M & L cutting of road, hard standing made of concrete or premix carpet, WBM, soiling and morrum filling including necessary excavation for laying of cable protection pipe all as directed including making good the road/hard standing by using all old/new materials and with PCC (1:2:4) type B1 (20mm graded stone aggregate) 200mm thick, required to match with the existing surface complete all as specified and directed.
M&L Earthing complete with galvanized steel with plate electrode 60 cm x 60 cm x 6.3mm thick buried directly in ground (earth kit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanized steel strip 32mm x 6mm dia by means of bolts, nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR part-I connected to earth test point incl necessary earth work and excavation PCC 1:3:6 type C1 using 20mm graded stone aggregate for earth chamber with SSR Part-II RCC cover 50mm thick 1:2:4 mix type B1, using 8mm dia TMT bars reinforcement @ 140mm c/c both ways, watering funnel with water pipe GI pipe 15mm dia medium grade and protection pipe GI 40 mm dia, light grade all as specified and directed in SSR Part II. Earth strip and protection pipe beyond 7.5m shall be measured and paid separately.
S&F PVC separators for suitable for LT over head line of 4 conductors and all as specified and directed
Fixing only MCCB 415 Volts, 4 pole, adjustable type, 63Amps, complete with all connected accessories including taking out old U/S one all as specified and directed. Note: MCCB Will be issued under Schedule'B' free for fixing only.
Fixing only MCCB 415 Volts, 4 pole, adjustable type, 100/160Amps, complete with all connected accessories including taking out old U/S one all as specified and directed. Note: MCCB Will be issued under Schedule'B' free for fixing only.
Fixing only MCCB 415 Volts, 4 pole, adjustable type, 200/260Amps, complete with all connected accessories including taking out old U/S one all as specified and directed. Note: MCCB Will be issued under Schedule'B' free for fixing only.
Fixing only MCCB 415 Volts, 4 pole, adjustable type, 320/400 Amps, complete with all connected accessories including taking out old U/S one all as specified and directed. Note: MCCB Will be issued under Schedule'B' free for fixing only.
Supply and install, test MPP-S heavy duty Capacitors upto 4 KVAr, including taking down existing unserviceable capacitors with electrical connections, complete all as specified and directed.
All as per item No. 49 hereinbefore but 5/7.5/10KVAr capacity
M&L for cleaning thoroughly LT distribution poles of any height and any description (Maximum 9 Mtr long ) with necessary cleaning agent including scrapping of old corroded paint dirt/ rust carefully and applying two coats aluminium paint including marking of pole numbers and colour washing of pole coping , complete all as specified and directed .
M&L for cleaning thoroughly the two pole structure of any height and any description with necessary cleaning agent including scrapping of old corroded paint dirt/ rust carefully and applying two coats aluminium paint including marking of pole numbers and colour washing of pole coping , complete all as specified and directed .
Supply and install, testisting and commissioning analog voltmeter of capacity 0-500V including taking down existing unserviceable Analog voltmeter with electrical connections, complete all as specified and directed.
Supply and install, testing and commissioning analog ammeter of capacity 0-250A/100A including taking down existing unserviceable analog ammeter with electrical connections, complete all as specified and directed.
Supply and install, testing, commissioning advanced power factor controller 12 segment including comprehensive displays with large, three-digit LED display, 3 logics(1:1:1), (1:2:2), (1:2:4) to connect banks, with automatic recognition or with standards programs RS-485 communication with electrical connections, including taking down existing unserviceable advanced power factor controller, complete all as specified and directed.
M&L for indoor, cubical type of suitable size with 2mm thick CRCA sheet single door, front open type, and painting with one coat of red oxide primer and two coats of powder caoted paint of MCCB enlosure for MCCB capacity 100 to 160 Amps with provision for entry/exit of suitable 3.5 core LT cable and connecting incomming and out goingLT cables all as specified and directed. Note: Rate quoted by the contractor shall be deemed to inclusive of taking down existing MCCB and re-fix in sheetmetal enclosure on the wall with suitable screws as directed.
S&F air break switch gange operated, triple pole, mechanical operated, verticllay or horizontally mounted on insulator and steel frame with operating mechanism worked from ground level for current rating 400 Amps, 11000 Volts with locking arrangement including connection and testing, including air break insulators (Switch), including taking down existing GOD complete all as specified and directed.
S&F copper wiring, electical and electronic parts of DG set AMF panel of 200 KVA DG Set, lugs, sleeves etc., including taking down of existing such wiring/spares all as specifeid and directed. Note: Supply only spare parts will be measured and paid separately.
Supply only DG set AMF panel control unit of modal No. DGC-6D suitable for DG Set 200 KVA of Engine kirlosker Cummins Ltd
Supply only relay chord(2+1) suitable for DG Set 200 KVA of Engine kirlosker Cummins Ltd
Supply only Push buttons & elements of Engine kirlosker Cummins Ltd
NAVANAND ENTERPRISES
STANDARD AGENCIES
SAI ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .