| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.0 LAccepted-AOC | L1 | Accepted-AOC Lowest tenderer | |
| 2 | L2₹42.6 L+₹4.6 L (12.1%)Rejected-Finance 00 KHATA NO 514 4357 PLOT NO 169 3484 KESHARA BHUBANESWAR KHURDA KHORDHA ODISHA 751007 | KHORDHA | ODISHA | 751007 | L2 | Rejected-Finance Other than Lowest tenderer | |
| 3 | L3₹53.5 L+₹15.5 L (40.7%)Rejected-Finance | L3 | Rejected-Finance Other than Lowest tenderer | |
| 4 | L4₹54.6 L+₹16.6 L (43.7%)Rejected-Finance | L4 | Rejected-Finance Other than Lowest tenderer | |
| 5 | L5₹55.5 L+₹17.5 L (46.1%)Rejected-Finance | L5 | Rejected-Finance Other than Lowest tenderer |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
13 Feb 2024, 6:00 pmClosed
Vipin Chandra Rai
GE UTILITY BATHINDA MIL STN
REPAIR/ MAINT AIR CONDITIONER (SPLIT TYPE / WINDOW TYPE / CASSATE TYPE ETC) AND VOLTAGE STABILIZER OF ZONE B UNDER GE (U).
2024_MES_637595_1
8779/2023-24/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Garrison Engineer Utility Bathinda
Class D cat c i
9 documents required · 9 mandatory
₹500
Garrison Engineer (U) Bathinda
₹1 L
Yes
12 Mar 2024
16 Jan 2024
15 Feb 2024
16 Jan 2024
13 Feb 2024
29 Jan 2024
Amount
Taking down carefully Window Type / Split Type / Cassate Type Air Conditioner 1.50 / 2.00 Ton capacity, from its location and removing dirt and dust from interior and exterior of the Air Conditioner and washing the condensor and evaporator with vami clean solution and other areas by soap solution, spraying pressurised water on condensor and evaportor with proper protection of electrical fixtures and connection, drying the blowing air, and placing in same position Window Type / Split Type / Cassate Type Air Conditioner conditioner complete all as directed. Note: Contractor will provide 01 Technician and 01 helper to the refrigeration subdivision for servicing of split / window / cassate type AC of 1.5/2 Ton capacity locating at ground floor / first floor / second floor / third floor installed at various places of cantt and also installing at its original position if required after repair and cost of the same are included in this item and nothing will be paid extra on this account
Providing two Nos of technician and two Nos of helper to the refrigeration sub division for attending and resolving day to day complaints of split / window / cassate type AC of any capacity in Bhatinda cantt area and repairing / installation / shifting / wiring / connecting / commissioning / testing / replacement of any item or component of avobe mentioned ACs locating at ground floor / first floor / second floor / third floor installed at various places of cantt and also installing at its original position if required after resolving complaints complete all as directed. Note: (i) Spare parts required like compressor, fan motor, drain motor, fan blade, capacitor, thermostat switch, evaporator coil, condenser coil, TK foam, copper pipe etc. to repair ACs shall be measured and paid separately under respective item as supply and fix in repair. (ii) T&P / vehicle required for technician and helpers shall be arranged by the contractor at his own cost to attend complaints and carry out the repair works at various locations of cantt area and the cost is included in this item and nothing extra shall be be paid in this regard.
Taking down unserviceable Rotary Compressor from Air Conditioner Window Type / Split type 2 Ton capacity of any make & type and Supply and Fixing New Rotary Compressor of air conditioner of window Type / Split type 2 Ton capacity along with new foundation rubber pads, nut and bolts including testing on full load complete all as directed. Make : Hitachi / Tecumseh / GMCC.
Taking down unserviceable Reciprocatory Compressor from Air Conditioner Window Type / Split type 1.50 Ton capacity of any make & type and Supply and Fixing New Reciprocatory Compressor of air conditioner of window Type / Split type 1.50 Ton capacity along with new foundation rubber pads, nut and bolts including testing on full load as directed. Make : Hitachi / Tecumseh / GMCC.
Taking down unserviceable Reciprocatory Compressor from Air Conditioner Window Type / Split type 2.00 Ton capacity of any make & type and Supply and Fixing New Reciprocatory Compressor of air conditioner of window Type / Split type 2.00 Ton capacity along with new foundation rubber pads, nut and bolts including testing on full load complete all as directed. Make : Hitachi / Tecumseh / GMCC.
Taking down unserviceable Rotary Compressor 3 Phase from Cassate Type Air Conditioner 4.00 Ton capacity of any make & type and Supply and Fixing new Rotary Compressor 4.00 Ton capacity of Cassate Type Air Conditioner along with new foundation rubber pads, nut and bolts including testing on full load complete all as directed. Make :Daikin/Blue Star/ Voltas. Note for serial item No. 03 to 06 :- (i)The cost of new foundation rubber pads, nut and bolts are included in this item and nothing shall be paid extra on this account. (ii)The cost of gas and charging the gas is also included in this item and nothing shall be paid extra on this account.
Supply and fixing in repair Fan motor of any size and any make for cassate type Air Conditioner complete all as directed.
Supply and Fixing in repair Drain motor of any size and any make for cassate type Air Conditioner complete all as directed.
Supply and Fixing in repair Fan motor suitable for Window Type / Split type Air Conditioner of capacity 1.5 Ton / 2.0 Ton complete all as directed.
Supply and Fixing in repair Fan Blade Metalic (aluminium) suitable for Window Type / Split Type Air Conditioner of capacity 1.5 Ton / 2.0 Ton complete all as directed.
Supply and Fixing in repair Running Capacitor 55 mfd in Air Conditioner of any make and model complete all as directed. Make : EPCOS / ASIAN / SIEMENS
Supply and Fixing in repair Running Capacitor 45 mfd in Air Conditioner of any make and model complete all as directed. Make : EPCOS / ASIAN / SIEMENS
Supply and Fixing in repair Running Capacitor 80-100 mfd in Air Conditioner of any make and model complete all as directed. Make : EPCOS / ASIAN / SIEMENS
Supply and Fixing in repair Running capacitor of 6 mfd for fan motor of Air Conditioneer all as directed. Make : EPCOS / ASIAN / SIEMENS
Supply and Fixing in repair Running capacitor of 2.5 mfd for fan motor of Air Conditioneer all as directed. Make : EPCOS / ASIAN / SIEMENS
Supply and Fixing in repair Thermostat Switch with knob suitable for Window Type Air Conditioner of any type and capacity complete all as directed.
Supply and Fixing in repair Plastic Front Grill assembly complete suitable for any make window type 1.5 / 2.0 tone Air Conditioner complete all as directed.
Supply and Fixing in repair Evaporator cooling coil made out of copper tubing and fins at appropriate spacing complete in all respects suitable for Window Type / Split type Air Conditioner capacity of 1.5 Ton /2.0 Ton including brazing/welding etc. complete all as directed.
Supply and Fixing in repair Condenser coil made out of copper tubing and fins at appropriate spacing complete in all respects suitable for Window Type / Split Type Air Conditioner 1.5 ton/2.0 ton including brazing / welding etc. complete all as directed.
Material and Labour for flushing out the condensate from gas system by creating vacuum, leakage testing of the system, injecting CTC solution for demoistureing the system and gas charging by R-22 upto the required pressure for 1.5 / 2.0 Ton Window Type / Split Type Air Conditioner complete all as directed. Note :- The cost of Material and Labour for charging of gas R-22 is included in this item and nothing shall be paid extra on this account.
Material and Labour for flushing out the condensate from gas system by creating vacuum, leakage testing of the system, injecting CTC solution for demoistureing the system and gas charging by R-410 upto the required pressure for 2.00 Ton /1.5 Ton Split Type / Cassate Type Air Conditioner complete all as directed. Note :- The cost of Material and Labour for charging of gas R-410 is included in this item and nothing shall be paid extra on this account.
Material and Labour for flushing out the condensate from gas system by creating vacuum, leakage testing of the system, injecting CTC solution for demoistureing the system and gas charging by R-32 upto the required pressure for 1.5 Ton / 2 .00 Ton Window / Split Type Air Conditioner complete all as directed. Note :- The cost of Material and Labour for charging R-32 is included in this item and nothing shall be paid extra on this account.
Supply and Fixing in repair Reverse valve (gun metal) for Window Type / Split Type Air Conditioner of 1.5 Ton / 2.0 Ton including copper pipe and including gas charging as required complete all as directed. Note :- The cost of material and labour for charging gas in Reverse valve is included in this item and nothing shall be paid extra on this account.
Supply and Fixing in repair PCB including Remote Control for remote sensing and operation suitable for Window Type / Split Type Air Conditioner 1.5 Ton / 2.0 Ton complete all as directed. Make :LG / Voltas / Blue Star / Hitachi
Supply and Fixing in repair PCB including remote control for remote sensing and operation suitable for Cassate Type Air Conditioner 2.00 Ton / 4.00 Ton complete all as directed. Make :Voltas / Daikin / Blue Star
Supply and fixing in repair invertor PCB including remote control for remote sensing and operation suitable for window / split type (indoor and outdoor complete) air conditioner1.5/2.0 ton complete all as directed. Make : Daikin/Blue Star/Hitachi/voltas/diakin
Supply and Fixing in repair indoor unit complete suitable for 1.5 Ton Split Type Air conditioner complete all as per manufacturer's instructions complete all as directed. Make :Hitachi(ryoku)/whirlpool/ carrier (Total line)
Supply and Fixing in repair out door unit complete suitable for 1.5 Ton split Type Air Conditioner complete all as per manufacturer's instructions and as directed. Make :Hitachi (ryoku)/whirlpool/carrier(total line)
Supply and Fixing in repair Metal clad Earth plug / socket 32 A 3 Pole, 230V AC complete all as directed. Make : LEGRAND / SCHNIDER / SIEMENS / HAVELLS
Supply, fixing in repair 2 KVA capacity Voltage stabilizer for automatic operation, single phase naturally air cooled, indoor type and designed for input variation between 150V - 250V with output voltage stabilized at 230V with accuracy of (+) or (-) 2.5% complete all as directed.
Taking down unserviceable Rotary Compressor from Air Conditioner Window Type / Split type 1.5 Ton capacity of any make & type and Supply and Fixing New Rotary Compressor of air conditioner of window Type / Split type 1.5 Ton capacity along with new foundation rubber pads, nut and bolts including testing on full load complete all as directed. Make : Hitachi / Tecumseh / GMCC. Note :- (i)The cost of new foundation rubber pads, nut and bolts are included in this item and nothing shall be paid extra on this account. (ii)The cost of gas and charging the gas is also included in this item and nothing shall be paid extra on this account.
Taking out unserviceable Blower motor from the indoor unit split Type Air Conditioner of any make / type / capacity and supply and fixing new Blower motor of same make / type / capacity including nut and bolts if required complete all as directed.
M&L for submain wiring with two run of 6 Sqmm, single core, PVC insulated and unsheathed cable conforming to IS 694, 1100 volts with copper conductor multi stranded drawn in and including 20 mm dia non metalic PVC grey conduit with all accessories such as Tees, elbows, junction box, reducers etc as required alongwith one run of 6 Sqmm single core PVC insulated and unsheathed cable conforming to IS 694, 1100 volts with copper conductor multi stranded as continous eart wire and connecting to existing main switch board/ distribution board of each building / Qtr as ordered and testing including taking down existing unserviceable submain wiring of any description and size complete all as directed. (Note : 2 runs of 6 sqmm cable, 1 run of 6 sqmm single core copper cable and 1 run of non metalic PVC conduit shall be measured as single run). Make: HAVELLS/ FINOLEX/ POLYCAB/ L&T / GLOSTER CABLES LIMITED
M & L for Copper tube, 9 mm / 6 mm dia, superior quality suitable for suction lines of split ACs of any make and capacity drawn trough pipes / fixed to walls / laid on floor or roof complete all as directed. Note : The cost of nut, bolts, screws etc for connecting of copper pipe from indoor to out door unit are included in this item and nothing shall be paid extra on this account.
Supply and Fixing inrepair MCB SP 32 A 'C' curve complete all as directed . Make : L&T / SIEMENS / LEGRAND / SCHNEIDER.
Supply and Fixing in repair chassis unit made out of MS sheet suitable for 1.5 Ton Window Type Air Conditiner with remote sensing system complete , duly spray painted with two coats of synthietic enamel paint colour (shade of colour as approved by Engineer-in- Charge) , including heavy duty copper tubing and copper fins evaporator coil, condenser coil ,copper wounded fan motor and suitable front grill etc. complete all as directed.
Supply & fix in repair Sheet metal enclosure having provision for a two pin and earth plug and socket complete with one single pole MCB up to 32 Amps, 240 volt capacity and tested on completion complete all as directed. Note: MCB and Two pin earth plug and socket will be measured and paid separately under appropriate item of BOQ. Make: L&T / SIEMENS / LEGRAND / SCHNEIDER.
Supply and fix in repair TK foam heat insulation tube of size 1/2 inch x 3/8 inch (inner dia x thickness) for AC piping hot and cold duly covered with EBP heavy duty high bond insulation tape heat resistant type complete all as directed.
Supply and fix in repair TK foam heat insulation tube of size 5/8 inch x 3/8 inch (inner dia x thickness) for AC piping hot and cold duly covered with EBP heavy duty high bond insulation tape heat resistant type complete all as directed.
Supply and fix in repair swing motor for indoor split AC/window AC of any make and capacity complete all as directed.
Supply and fix in repair blower for indoor split AC of any make and any capacity complete all as directed.
Supply and fix in repair indoor Split AC flexible drain pipe made of PVC of length not less than 5 meter and dia not less than 15 mm complete all as directed.
Supply and fix in repair outdoor unit AC stand including with nuts,bolts,rubber pads etc complete for mounting outdoor unit of split AC of any make and any capacity complete all as directed.
M & L for Sub main wiring with 2 runs of 4.0 sqmm, single core, PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dian no metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 2.5 sqmm single core PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing including taking down existing one complete all as directed. (Note : 2 runs of 4 sqmm cable, 1 run of 2.5 sqmm single core copper cable and 1 run of non metalic PVC conduit shall be measured as single run). Make: HAVELLS/ FINOLEX/ POLYCAB/ L&T / GLOSTER CABLES LIMITED
Supply and fixing in repair of 5.0 KVA capacity Voltage stabilizer for automatic operation, single phase naturally air cooled, indoor type and designed for input variation between 150V - 250V with output voltage stabilized at 230V with accuracy of (+) or (-) 2.5% complete all as directed.
Supply and fix in repair dust proof/water proof protection cover of polyster material for indoor and outdoor unit complete all as directed.
Dismantling of existing unservicebale voltage stablizer for repairs with replacement of relays electronic voltage sensor circut and meter, micro switch, indication light RC filters and other connected items for making functional and rewinding of unserviceable transformer with super enameled copper wire of appropriate size, varnishing assembling and testing completeof capacity 2 KVA to 5 KVA upto satisfactory function complete all as directed by Engr- in-Charge.
Supply & install Cassette type units indoor/outdoor complete with cordless remote control unit and with in built Heating and cooling arrangement and Digital Inverter twin roatry compressor, single phase untis 220V-240V, 50Hz of capacity 2.0TR including dismantling of old existing Cassette type unit complete all as directed by Engineer-in-Charge.
Supply & install wall split units indoor/outdoor complete with cordless remote control unit non star rated wall mount and with in built air ioniser and plasma filter for better indoor air quality of capacity 1.5 TR including dismantling of old existing split unit complete all as directed by Engineer-in-Charge.
Supply & install hi wall split units indoor/outdoor complete with cordless remote control unit non star rated wall mount and with in built air ioniser and plasma filter for better indoor air quality of capacity 2.0 TR including dismantling of old existing split unit complete all as directed by Engineer-in-Charge.
Supply & install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built Heating and Cooling arrangement and Digital inverter twin rotary of capacity 1.5 TR including dismantling of old existing split unit complete all as directed by Engineer-in-Charge.
Supply & install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built Heating and Cooling arrangement and Digital inverter twin rotary of capacity 2.0 TR including dismantling of old existing split unit complete all as directed by Engineer-in-Charge.
M&L for replacement of overload protection relay for window AC, water cooler and refrigaretor of make and model as per existing.
S&F in replacement of capillary tubing of any size not less than 0.5 mtr for AC/Water cooler/refrigerator complete all as directed.
S&F in replacement 3 pin plug top of capacity 15 Amp complete all as directed.
Material and Labour for flushing out the condensate from gas system by creating vacuum, leakage testing of the system, injecting CTC solution for demoistureing the system and charging R-134 gas upto the required pressure complete all as approved and directed.
Taking out the unserviceable compressor (Sealed unit) from water cooler 40 liters capacity of any make and type and repalacement of new compressor obtained from the factory out let make Copeland/Tecumseh/Whirlpool/LG model KCE 444, AE 4440 YGS including suitable relay, over load and starting/running capacitor, flushing out the old bunt condensite from the gas system by vacuumisation, cleaning the system by CTC solution, pressure testing of the system, gas charging with R-134a gas upto the desired pressure, testing & commissioning the water cooler complete all as directed.
Taking out the unserviceable compressor (Sealed unit) from water cooler 60/120 liters capacity of any make and type and repalacement of new compressor obtained from the factory out let make Copeland/Tecumseh/Whirlpool/LG model KCE 443, AKR 4460 including suitable relay, over load and starting/running capacitor flushing out the old burnt condensafe from the gas system by vacuumisation, cleaning the system by CTC solution , pressure testing of the system, gas charging with R-134a gas upto the desired pressure, testing & commissioning the water cooler complete all as directed.
Taking out the unserviceable compressor (Sealed unit) from water cooler 150 liters capacity of any make and type and repalacement of new compressor obtained from the factory out let make Copeland/Tecumseh/Whirlpool/LG, model ACJ 513, AW 1000, including suitable relay, over load and starting/running capacitor flushing out the old burnt condensafe from the gas system by vacuumisation, cleaning the system by CTC solution , pressure testing of the system, gas charging with R-134a / 22 gas upto the desired pressure, testing & commissioning the water cooler complete all as directed.
S&F in repair blower fan motor 1/10 HP suitable for water cooler, single phase 230 Volts including mounting ring/washer complete all as directed.
S&F in repair blower fan motor 1/35 HP suitable for water cooler, single phase 230 Volts including mounting ring/washer complete all as directed.
S&F in repair Fan blade plastic suitable for 1/35 HP motor complete all as directed.
S&F in repair Fan blade plastic suitable for 1/10 HP motor complete all as directed.
S&F in repair stainless steel taps push button type, 15 mm dia for water cooler of any capacity suitable for water cooler of make Usha/Blue Star complete all as directed.
S&F in repair Relay & overload set suitable for water cooler complete all as directed. Make : Annapurna/Reneutral/Denfoss
S&F in repair Running capacitor of 15 mfd complete all as directed.
S&F in repair Running capacitor of 40/60 mfd complete all as directed.
S&F in repair Thermostate valve complete all as directed.
Material and labour for taking out the inner water tank of water cooler of any size and brazing/welding including applying compounds as required to stop leakage from the water tank, replacement of glass wool/toffed sheet, chicken wire mesh of appropiate thickness and spacing and stoppage of leakage in tubing (if any) around the tank and refixing the same as per oringinal pattern complete all as directed.
S&F in repair copper condesor for 40/80 ltr capacity water cooler complete all as directed.
S&F in repair copper condesor for 60/120 ltr capacity water cooler complete all as directed.
S&F in repair drain hose pipe not less than 1.5 metre length and 30 mm dia with clamping arrangment complete all as directed.
S&F in repair drain hose pipe not less than 1.5 metre length and 40 mm dia with clamping arrangment complete all as directed.
S&F in repair Stainless Steel body unit of Water Cooler with Condenser Coil, Copper Wound Fan Motor and tank including heavy duty copper tubing, stainless steel taps push button type 15 mm dia of 40/80 ltr capacity complete all as directed.
Supply, installation, commissioning in repair water cooler fully stainless steel, electric driven single phase having approx strorage and nominal cooling capacity 40/80 complete all as directed by Engineer-in-Charge.
Supply, installation, commissioning in repair water cooler fully stainless steel, electric driven single phase having approx strorage and nominal cooling capacity 60/120 complete all as directed by Engineer-in-Charge. Make for serial item No. 76 to 77: Usha / Blue Star / Voltas
Sai Enterprises
NASIB ENGINEERS AND CONSTRUCTION
DIAMOND SALES COROPORATION
Sandeep Enterprises
M/s Kataria Construction Company
B K CONTRACTORS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .