Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.4 LAccepted-AOC WARD NO 13 NEW SURATGARH | SURATGARH | L1 | Accepted-AOC VALID | |
| 2 | L2₹7.9 L+₹1.2 L (17.3%)Rejected-Finance | L2 | Rejected-Finance NOT BEING LOWEST | |
| 3 | L3₹8.6 L+₹1.9 L (27.8%)Rejected-Finance RCP GURUDWARA ROAD WARD NO 29 SURATGARH SRI GANGANAGAR 335804 | SURATGARH | SRI GANGANAGAR | RAJASTHAN | 335804 | L3 | Rejected-Finance NOT BEING LOWEST | |
| 4 | L4₹10.4 L+₹3.7 L (54.9%)Rejected-Finance NEW ABADI KISHANPURA SURATGARH 335804 DISTT SRIGANGANGAR RAJ | GANGANAGAR | RAJASTHAN | 335804 | L4 | Rejected-Finance NOT BEING LOWEST | |
| 5 | L5₹15.0 L+₹8.2 L (122.2%)Rejected-Finance MULTICARE ENTERPRISES PRIVATE LIMITED COMMERCIAL COMPLEX VARDHMAN TOWER PREE T VIHAR G 63 GROUND FLOOR PLOT NO 16 17 18 110092 DELHI EAST DELHI N N 110092 | EAST DELHI | DELHI | 110092 | L5 | Rejected-Finance NOT BEING LOWEST |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
16 Aug 2022, 6:00 pmClosed
Lt Col Priyesh Srivastava
GE (AF) SURATGARH
REPAIR MAINT REWIRING RENEWAL OF INTERNAL ELECTRIFICATION FITTINGS AND FIXTURES AT AKASH VIHAR AND OFFICERS AREA ALONGWITH ALLIED EM WORKS AT AF STATION SURATGARH
2022_MES_539128_1
8974/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) SURATGARH
AS PER TENDER DOCUMENTS
10 documents required · 10 mandatory
₹500
GE (AF) SURATGARH
₹30,000
Yes
7 Oct 2022
19 Jul 2022
18 Aug 2022
19 Jul 2022
16 Aug 2022
2 Aug 2022
Amount
BOQ (REPAIR/MAINT/REWIRING/RENEWAL OF INTERNAL ELECTRIFICATION FITTINGS AND FIXTURES AT AKASH VIHAR AND OFFICERS AREA ALONGWITH ALLIED EM WORKS AT AF STATION SURATGARH.)
Taking down DB/main switch of any size and making good disturbed surfaces of wall/floor, complete all as specified and directed by Engineer-in-Charge. Note - Temporary power supply shall be provided by contractor.
Taking down unserviceable submain wiring and making good disturbed surfaces of walls/ floor etc matching with the existing surface, complete all as specified and directed by Engineer-in-Charge.
Taking down carefully aluminum point wiring (light, fans, socket etc) complete including battens and fittings such as switch, ceiling rose, light fittings, regulators, socket, etc. and making good disturbed surfaces of wall/floor, etc. complete all as specified and directed by Engineer-in-Charge. Note :- Temporary power supply shall be provided by contractor.
All as per serial item No 3.00 here-in-before but except conduit , complete all as specified and directed by Engineer-in-Charge.
S&F for Sub main wiring (concealed ) with two single core 4 sq mm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through including chasing cutting in any type of masonary including 25 mm dia non-metallic PVC conduit fixed in wall including 2.5 sq mm copper earth continuity wire, accessories and connecting to earth dolly, complete all as specified and directed by Engineer-in-Charge. Note :- 2 runs of 4 Sqmm, 1 run of PVC conduit & 1 run of 2.5 Sqmm cable shall be measured as single unit length.
S&F for Sub-main wiring in (existing concealed PVC conduit) with two single core 4 sq mm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through including chasing cutting in any type of masonry including 2.5 sq mm copper earth continuity wire, accessories and connecting to earth dolly , complete all as specified and directed by Engineer-in-Charge. Note :- 2 runs of 4 Sqmm & 1 run of 2.5 Sqmm cable shall be measured as single unit length.
M&L for Sub-main wiring in (existing concealed PVC conduit) with two single core 6 sq mm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through including chasing cutting in any type of masnory including 4 sq mm copper earth continuity wire, accessories and connecting to earth dolly , complete all as specified and directed by Engineer-in-Charge. Note :- 2 runs of 6 Sqmm & 1 run of 4 Sqmm cable shall be measured as single unit length. Note for item No.5 to 7 :- The disturbed surfaces of wall for concealing the wiring shall be make good by applying cement plaster, putty and colour wash etc matching with the existing surfaces.
M& L for Point wiring (concealed) complete with FRLS PVC insulated unsheathed 1100 Volts grade, conforming to IS-694, 1.5 sq mm (nominal area) multi stranded copper conductor cable drawn though in and including non metallic medium grade rigid PVC conduit accessories, ISI marked, 19/20 mm dia including all accessories, concealed in walls/floors/ceilings etc by cutting chases using machine and making good the disturbed surface, with and including sunken type pressed steel/welded MS terminal box 1.2 mm thick bakelite laminated sheet top cover 3 mm thick and 1.5 sq mm copper earth continuity wire connected to earth dolly complete for the following, complete all as specified and directed by Engineer-in-Charge:-
One light/fan/exhaust fan point controlled by one switch.
One bell/buzzer point controlled by one bell push switch
One switch socket outlet 3 pin 6 amp on same board.
One light point controlled by two 2-way switches with cables
One 3 pin socket outlet, 5 amps point on Independent board.
All as per item No 8 above but 4 sq mm cable size with 2.5 sq mm earth continuity wire for one 3 pin socket outlet, 15 Amps on independent board.(AC/Geyser), complete all as specified and directed.
M&L for Point wiring complete with 1.5 Sqmm (nominal area) FRLS PVC insulated, multi stranded, copper conductor cable unsheathed in existing concealed PVC conduit and PVC insulated copper conductor cable of size 1.5 sq mm as earth wire , connected to common earth dolly and replacement of aminated sheet cover of 3 mm thick for mounting swiches,socket,regulator suitable for mounting switches , complete for the following , complete all as specified and directed by Engineer-in-Charge:-
One light/fan point controlled by one switch.
One bell point controlled by one bell push switch
One switch socket outlet 3 pin 6 amp on same board.
One 3 pin socket outlet 5 amps on independent board
All as per item No 12 above but one 3 pin socket out let 15 Amps on independent board, with cables 2.5 sqmm sizer and earth wire 1.5 sqmm, complete all as specified and directed.
Note for Item No. 8 to 10 :- The disturbed surfaces of wall for concealing the wiring shall be make good by applying cement plaster, putty and colour wash etc to match with the existing surfaces. The quted rate shall include for the same.
Taking down old U/S light fitting and supply and fixing LED lights fitting 1x20 W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and directed.
Taking down old U/S light fitting and supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220V AC decorative type with driver holder and LED lamp including connecting up with three core fleexible copper conductor cable of suitable size, complete all as specified and directed.
Taking down old U/S light fitting and S&F LED light fitting 1X9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed.
S&F LED light fitting Roadway LED street light fitting 35 watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP-65/66 protection, complete all as specified and directed.
S&F Angle holder, PVC Polycarbonate type with back plate suitable for batten fittings, complete all as specified and directed by Engineer-in-Charge.
S&F Stepped type (0-4 step) electronic regulator for ceiling fan 1200 mm, 240 volts, 100 Watts, single pole, including connecting and testing , complete all as specified and directed by Engineer-in-Charge.
S&F Door bell ding dong, AC, 230 Volts, single pole including connecting and testing , complete all as specified and directed by Engineer-in-Charge.
S&F Bell push switch, single pole, one way flush type, 5 Amps, 240 volts, including connecting and testing , complete all as specified and directed by Engineer-in-Charge.
S&F Socket outlet, flush type 2 in 1, 3 pin, 5 amps, 240 volts, including connecting and testing , complete all as specified and directed by Engineer-in-Charge.
S&F Switch piano flush button single pole one way 5 amp 240 volts, including connecting and testing , complete all as specified and directed by Engineer-in-Charge.
S&F Switch piano flush type single pole two way 5 amps 240 volts , including connecting and testing ,complete all as specified and directed by Engineer-in-Charge.
S&F Socket outlet 2 in 1, 3 pin, 5 and 15 amps, flush type, 240 volts, including connecting and testing ,complete all as specified and directed by Engineer-in-Charge.
S&F Switch piano flush button single pole one way 15 amp 240 volts, including connecting and testing ,complete all as specified and directed by Engineer-in-Charge.
S&F Ceiling rose, surface bakelite, 65 x 50 mm, three terminals, including connecting and testing, complete all as specified and directed by Engineer-in-Charge.
S&F Step 0-4, modular type electronic regulator for ceiling fan 1200 mm sweep, 240 volts, 100 Watts humfree single pole, complete all as specified and directed by Engineer-in-Charge.
S&F Bell push, modular type, 6 Amps, 1 module, 230 volts , complete all as specified and directed by Engineer-in-Charge.
S&F Socket modular type single pole one way 6 Amps 2/3 pin 250 volts including taking down the old modular socket, complete all as specified and directed by Engineer-in-Charge.
S&F Switch modular type, single pole one way 6 Amps, 250 volts Ac suitable for modular switch boxes without indicator, complete all as specified and directed by Engineer-in-Charge.
S&F Socket modular type 16 Amps, 3 pin combine, 2 module,240 volts , complete all as specified and directed by Engineer-in-Charge.
S&F Switch modular type 16 Amps, 1 module,240 volts, complete all as specified and directed by Engineer-in-Charge.
S&F Sheet metal enclosure with socket plug top single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20 amps , 240 Volts, complete all as specified and directed by Engineer-in-Charge.
S&F Sheet metal Vertical TPN double door DB 4 Way, 415 Volt, TPN with 200 Amps rated bus bar complete with MCCB TPN 100 Amps, 16 kA, DPX 160 series as incoming and MCB's SP 40 Amps, 10 kA - 06 Nos as out Going and complete all as specefied and directed.
S&F Sheet metal enclosures for SPN DB's with double glazed door for incorporating MCBs,IP-43 , 8 way with 200 amps rated busbar, 240 volts, as per IS-8623, fixed in repair complete all as specified and directed by Engineer-in-Charge.
S&F Sheet metal enclosures for SPN DB's with double glazed door for incorporating MCBs, IP-43, 4 way, with 200 amps rated busbar, 415 volts, as per IS-8623, fixed in repair complete all as specified and directed by Engineer-in-Charge.
S&F MCB four poles, 63 Amps, breaking capacity 10 KA 'C' curve confirming to IS-8828, 240 volts, 50 HZ including making necessary incoming and outgoing electrical connection with suitable size of copper lugs etc fixed in repair complete all as specified and directed by Engineer-in-Charge.
S&F MCB SPN 40-63 amps 'C' series, breaking capacity 10 KA, 'C' curve 240 volts, 50 Hz including necessary incoming and out going electric connection with suitable size of copper lugs etc fixed in repair complete all as specified and directed by Engineer-in-Charge.
S&F MCB SP, 6 to 32 Amps, C series, breaking capacity 10 KA, 'C' curve 240 volts, 50 Hz including necessary incoming and out going electric connection with suitable size of copper lugs etc fixed in repair complete all as specified and directed by Engineer-in-Charge.
M&L Earthing complete with G I earth plate electrode 600 mm x 600 mm x 6 mm burried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to G I earth strip 4 dia G I wire by means of brass bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 40 mm bore (light grade) connected to main switch board or any other electrical equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6), type C-1 chamber, pit cover of precast RCC (1:2:4), type B-1, reinforced XPM of weight not less than 4 kg/ Sq.m and MS frame etc. including replacment of old unserviceable earthing, complete all as specified and as directed by Engineer-in-Charge. Note :- (i) The unit rate includes earth lead and protection pipe up to maximum 7.5 metre from earth plate to earth point/test point. (ii) Earth pit shall be constructed minimum 0.5 metre away from earth.
S&F for single phase temperproof digital meter equipped with 6 digit ultra bright LED counter, direct operation upto 5-30 Amp (without CT), operating on 220 volt single phase, direct read without multiplication factor, latest microcountroller based technology, Mains LED to indicate presence of auxillary supply, eroor indication for faulty / reverse connections etc reassembling to make meter serviceable, complete all as directed by Engineer-in-Charge. Make :- HPL/L&T/siemens
Taking down old u/s light fitting and supply, Installation, Testing and commissioning of LED 36 Watt environmental friendly, new generation, aesthetically designed, ultra modern recess mounting luminaries with high brightness SMD LEDs as light source 28 watt with nominal system lumen output of 2800 lumens and a minimum system efficacy of 100 lm/W. The luminarie shall have a rated system lifetime of 50,000 burning hours at L70. The lumnarie should have a colour temperature of 6500K and CRI>70. The lumnarie shall meet IP 66 rating and IK 09 rating with THD<20% and PF>0.9, complete all as specified and directed by Engineer-in-Charge.
S&F post top lantern LED type 40 watt 230 volts AC outdoor type with decorative post top for 360 degree indirect light IP-65 protection with impact and corrosion resistant with driver & lamp, complete all as specified and directed.
Contract Amount shall be derived after deducting the amount of Schedule of Credit in General Summary on serial page No 17 of tender documents.
m/s krishna builders
SRI SAI CONSTRUCTION COMPANY
M/s JUGAL KISHORE MISHRA AND SONS
Multicare Enterprises Pvt. Ltd.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .