Cable type
Cable size
No of cores
Voltage rating
Conforming to IS
Conductor
Conductor Material
Conductor Material Flexibility
Shape of Conductor
Standards
Insulation
Material
Nominal insulation Thickness
Inner Sheath /Bedding
Material
Thickness
Armour
Material
Nominal Dia of armour wire
Standards
Overall / Outer Sheath
Material
Min. Outer sheath thickness
Approx over all dia of cable
Electrical Parameters
Maximum. D.C. resistance/km of conductor at 20 deg.C
AC resistance/kilometer of conductor at 90 deg.C(approx.)
Reactance/kilometre (approx.)
Capacitance/Kilometre (approx.)
Normal Current rating.
Ground
Short circuit current rating for 1 second duration
Operating Temperature
Short circuit Temp
FR-LSH PROPERTIES
Oxygen Index
Temperature Index
Smoke density rating
Acid gas generation (HCL)
Flammability test
Drum Details
Drum Material & standards
Standard Drum Length
Sequential length marking
Embossing on Outer Sheath
Approx Wt.of Cable
Bidders Signature
GUARANTEED TECHNICAL PARTICULARS (GTP) Annexure 22A
Guaranteed Technical Particulars(GTP) for 1100V Grade,4Cx16Sq.mm Aluminium, PVC insulated , Galvanized Steel wire Armoured , LT Power Cable
Cable type
Cable size
No of cores
Voltage Rating
IS Standard
7. Conductor
8. Insulation
9. Armour
10. Overall / Outer Sheath
Minimum bending radius
Colour of sheath
Safe Pulling force
Approx overall dia of cable
11. Electrical Parameters
Normal Current rating.
Short circuit current rating for 1 second duration
Max. rated conductor temp
Max. allowable conductor temperature during short circuit
Continuous Current carrying capacities for conditions:
i)Air Temperature
ii)Ground Temperature
iii)Depth of laying
a) In Ground
b) In Air
FR-LSH PROPERTIES
Binder/Tapes
Drum Details
Approx Weight of Cable
Methods of Test for Cables
Furnish copy of Type test certificate not more than 5 years from the date of subject Notice Inviting Tender of similar cable for having Tested at CPRI or equivalent athority for conforming its performance as per relevent standards specified in the above GTP,Type Tests list and Technical specification for the subject cable indicated in the subject Tender.
Tests
Executive Engineer (MSP) Jog, Karnataka Power Corporation Ltd Jogfalls-577435
ANNEXURE-II
GUARANTEED TECHNICAL PARTICULARS
Cable type
Cable size
No of cores
Voltage rating
Conforming to IS
Conductor
Conductor Material
Conductor Material Flexibility
Shape of Conductor
Standards
Insulation
Material
Nominal insulation Thickness
Inner Sheath /Bedding
Material
Thickness
Armour
Material
Nominal Dia of armour wire
Standards
Overall / Outer Sheath
Material
Min. Outer sheath thickness
Approx over all dia of cable
Electrical Parameters
Maximum. D.C. resistance/km of conductor at 20 deg.C
AC resistance/kilometer of conductor at 90 deg.C(approx.)
Reactance/kilometre (approx.)
Capacitance/Kilometre (approx.)
Normal Current rating.
Ground
Short circuit current rating for 1 second duration
Operating Temperature
Short circuit Temp
FR-LSH PROPERTIES
Oxygen Index
Temperature Index
Smoke density rating
Acid gas generation (HCL)
Flammability test
Drum Details
Drum Material & standards
Standard Drum Length
Sequential length marking
Embossing on Outer Sheath
Approx Wt.of Cable
Bidders Signature
GUARANTEED TECHNICAL PARTICULARS (GTP) Annexure 20 A
Guaranteed Technical Particulars(GTP) for 1100V Grade,3.5Cx25Sq.mm Aluminium , PVC insulated ,Galvanized Steel round wire Armoured , LT Power Cable
Cable type
Cable size
No of cores
Voltage Rating
IS Standard
7. Conductor
8. Insulation
9. Armour
10. Overall / Outer Sheath
Minimum bending radius
Colour of sheath
Safe Pulling force
Approx overall dia of cable
11. Electrical Parameters
Normal Current rating.
Short circuit current rating for 1 second duration
Max. rated conductor temp
Max. allowable conductor temperature during short circuit
Continuous Current carrying capacities for conditions:
i)Air Temperature
ii)Ground Temperature
iii)Depth of laying
a) In Ground
b) In Air
FR-LSH PROPERTIES
Binder/Tapes
Drum Details
Approx Weight of Cable
Methods of Test for Cables
Furnish copy of Type test certificate not more than 5 years from the date of subject Notice Inviting Tender of similar cable for having Tested at CPRI or equivalent athority for conforming its performance as per relevent standards specified in the above GTP,Type Tests list and Technical specification for the subject cable indicated in the subject Tender.
Tests
Executive Engineer (MSP) Jog, Karnataka Power Corporation Ltd Jogfalls-577435
ANNEXURE-II
GUARANTEED TECHNICAL PARTICULARS
Cable type
Cable size
No of cores
Voltage rating
Conforming to IS
Conductor
Conductor Material
Conductor Material Flexibility
Shape of Conductor
Standards
Insulation
Material
Nominal insulation Thickness
Inner Sheath /Bedding
Material
Thickness
Armour
Material
Nominal Dia of armour wire
Standards
Overall / Outer Sheath
Material
Min. Outer sheath thickness
Approx over all dia of cable
Electrical Parameters
Maximum. D.C. resistance/km of conductor at 20 deg.C
AC resistance/kilometer of conductor at 90 deg.C(approx.)
Reactance/kilometre (approx.)
Capacitance/Kilometre (approx.)
Normal Current rating.
Ground
Short circuit current rating for 1 second duration
Operating Temperature
Short circuit Temp
FR-LSH PROPERTIES
Oxygen Index
Temperature Index
Smoke density rating
Acid gas generation (HCL)
Flammability test
Drum Details
Drum Material & standards
Standard Drum Length
Sequential length marking
Embossing on Outer Sheath
Approx Wt.of Cable
Bidders Signature
GUARANTEED TECHNICAL PARTICULARS (GTP) Annexure 15A
Guaranteed Technical Particulars(GTP) for 1100V Grade,3.5Cx35Sq.mm aluminium, PVC insulated , Galvanized steel wire Armoured , LT Power Cable
Cable type
Cable size
No of cores
Voltage Rating
IS Standard
7. Conductor
8. Insulation
9. Armour
10. Overall / Outer Sheath
Minimum bending radius
Colour of sheath
Safe Pulling force
Approx overall dia of cable
11. Electrical Parameters
Normal Current rating.
Short circuit current rating for 1 second duration
Max. rated conductor temp
Max. allowable conductor temperature during short circuit
Continuous Current carrying capacities for conditions:
i)Air Temperature
ii)Ground Temperature
iii)Depth of laying
a) In Ground
b) In Air
FR-LSH PROPERTIES
Binder/Tapes
Drum Details
Approx Weight of Cable
Methods of Test for Cables
Furnish copy of Type test certificate not more than 5 years from the date of subject Notice Inviting Tender of similar cable for having Tested at CPRI or equivalent athority for conforming its performance as per relevent standards specified in the above GTP,Type Tests list and Technical specification for the subject cable indicated in the subject Tender.
Tests
Executive Engineer (MSP) Jog, Karnataka Power Corporation Ltd Jogfalls-577435
ANNEXURE-II
GUARANTEED TECHNICAL PARTICULARS
Cable type
Cable size
No of cores
Voltage rating
Conforming to IS
Conductor
Conductor Material
Conductor Material Flexibility
Shape of Conductor
Standards
Insulation
Material
Nominal insulation Thickness
Inner Sheath /Bedding
Material
Thickness
Armour
Material
Nominal Dia of armour wire
Standards
Overall / Outer Sheath
Material
Min. Outer sheath thickness
Approx over all dia of cable
Electrical Parameters
Maximum. D.C. resistance/km of conductor at 20 deg.C
AC resistance/kilometer of conductor at 90 deg.C(approx.)
Reactance/kilometre (approx.)
Capacitance/Kilometre (approx.)
Normal Current rating.
Ground
Short circuit current rating for 1 second duration
Operating Temperature
Short circuit Temp
FR-LSH PROPERTIES
Oxygen Index
Temperature Index
Smoke density rating
Acid gas generation (HCL)
Flammability test
Drum Details
Drum Material & standards
Standard Drum Length
Sequential length marking
Embossing on Outer Sheath
Approx Wt.of Cable
Bidders Signature
GUARANTEED TECHNICAL PARTICULARS (GTP) Annexure 2 A
Guaranteed Technical Particulars(GTP) For 11 kV , 3C x 95 Sq.mm, Aluminium Conductor, XLPE Insulated, Armoured, PVC Sheathed UG Power Cable
Cable type
Cable size
No of cores
Voltage Rating
IS Standard
7. Conductor
8. Insulation
9. Armour
10. Overall / Outer Sheath
Minimum bending radius
Tolerance on thickness
Colour of sheath
Safe Pulling force
Approx overall dia of cable
11. Electrical Parameters
Normal Current rating.
Short circuit current rating for 1 second duration
Max. rated conductor temp
Max. allowable conductor temperature during short circuit
Continuous Current carrying capacities for conditions:
i)Air Temperature
ii)Ground Temperature
iii)Depth of laying
a) In Ground
b) In Air
FR-LSH PROPERTIES
Binder/Tapes
Drum Details
Approx Weight of Cable
Methods of Test for Cables
The cable offered shall have successfully passed all type of test described in IS 7098-part-2. And furnish copy of Type test certificate not more than 5 years from the date of subject Notice Inviting Tender of similar cable for having Tested at CPRI or equivalent athority for conforming its performance as per relevent standards specified in the above GTP,Type Tests list and Technical specification for the subject cable indicated in the subject Tender.
Tests
Performance guarantee
Executive Engineer (MSP) Jog, Karnataka Power Corporation Ltd Jogfalls-577435
ANNEXURE-II
GUARANTEED TECHNICAL PARTICULARS
Cable type
Cable size
No of cores
Voltage rating
Conforming to IS
Conductor
Conductor Material
Conductor Material Flexibility
Shape of Conductor
Standards
Insulation
Material
Nominal insulation Thickness
Inner Sheath /Bedding
Material
Thickness
Armour
Material
Nominal Dia of armour wire
Standards
Overall / Outer Sheath
Material
Min. Outer sheath thickness
Approx over all dia of cable
Electrical Parameters
Maximum. D.C. resistance/km of conductor at 20 deg.C
AC resistance/kilometer of conductor at 90 deg.C(approx.)
Reactance/kilometre (approx.)
Capacitance/Kilometre (approx.)
Normal Current rating.
Ground
Short circuit current rating for 1 second duration
Operating Temperature
Short circuit Temp
FR-LSH PROPERTIES
Oxygen Index
Temperature Index
Smoke density rating
Acid gas generation (HCL)
Flammability test
Drum Details
Drum Material & standards
Standard Drum Length
Sequential length marking
Embossing on Outer Sheath
Approx Wt.of Cable
Bidders Signature
GUARANTEED TECHNICAL PARTICULARS (GTP) Annexure 21A
Guaranteed Technical Particulars(GTP) for 1100V Grade,3.5Cx70 Sq.mm Aluminium , PVC insulated ,Galvanized Steel round wire Armoured , LT Power Cable
Cable type
Cable size
No of cores
Voltage Rating
IS Standard
7. Conductor
8. Insulation
9. Armour
10. Overall / Outer Sheath
Minimum bending radius
Colour of sheath
Safe Pulling force
Approx overall dia of cable
11. Electrical Parameters
Normal Current rating.
Short circuit current rating for 1 second duration
Max. rated conductor temp
Max. allowable conductor temperature during short circuit
Continuous Current carrying capacities for conditions:
i)Air Temperature
ii)Ground Temperature
iii)Depth of laying
a) In Ground
b) In Air
FR-LSH PROPERTIES
Binder/Tapes
Drum Details
Approx Weight of Cable
Methods of Test for Cables
Furnish copy of Type test certificate not more than 5 years from the date of subject Notice Inviting Tender of similar cable for having Tested at CPRI or equivalent athority for conforming its performance as per relevent standards specified in the above GTP,Type Tests list and Technical specification for the subject cable indicated in the subject Tender.
Tests
Executive Engineer (MSP) Jog, Karnataka Power Corporation Ltd Jogfalls-577435
ANNEXURE-II
GUARANTEED TECHNICAL PARTICULARS
Cable type
Cable size
No of cores
Voltage rating
Conforming to IS
Conductor
Conductor Material
Conductor Material Flexibility
Shape of Conductor
Standards
Insulation
Material
Nominal insulation Thickness
Inner Sheath /Bedding
Material
Thickness
Armour
Material
Nominal Dia of armour wire
Standards
Overall / Outer Sheath
Material
Min. Outer sheath thickness
Approx over all dia of cable
Electrical Parameters
Maximum. D.C. resistance/km of conductor at 20 deg.C
AC resistance/kilometer of conductor at 90 deg.C(approx.)
Reactance/kilometre (approx.)
Capacitance/Kilometre (approx.)
Normal Current rating.
Ground
Short circuit current rating for 1 second duration
Operating Temperature
Short circuit Temp
FR-LSH PROPERTIES
Oxygen Index
Temperature Index
Smoke density rating
Acid gas generation (HCL)
Flammability test
Drum Details
Drum Material & standards
Standard Drum Length
Sequential length marking
Embossing on Outer Sheath
Approx Wt.of Cable
Bidders Signature
GUARANTEED TECHNICAL PARTICULARS (GTP) Annexure 3A
Guaranteed Technical Particulars(GTP) for 1100V Grade,4Cx95 Sq.mm aluminium, PVC insulated , Galvanized steel wire Armoured , LT Power Cable
Cable type
Cable size
No of cores
Voltage Rating
IS Standard
7. Conductor
8. Insulation
9. Armour
10. Overall / Outer Sheath
Minimum bending radius
Colour of sheath
Safe Pulling force
Approx overall dia of cable
11. Electrical Parameters
Normal Current rating.
Short circuit current rating for 1 second duration
Max. rated conductor temp
Max. allowable conductor temperature during short circuit
Continuous Current carrying capacities for conditions:
i)Air Temperature
ii)Ground Temperature
iii)Depth of laying
a) In Ground
b) In Air
FR-LSH PROPERTIES
Binder/Tapes
Drum Details
Approx Weight of Cable
Methods of Test for Cables
Furnish copy of Type test certificate not more than 5 years from the date of subject Notice Inviting Tender of similar cable for having Tested at CPRI or equivalent athority for conforming its performance as per relevent standards specified in the above GTP,Type Tests list and Technical specification for the subject cable indicated in the subject Tender.
Tests
Executive Engineer (MSP) Jog, Karnataka Power Corporation Ltd Jogfalls-577435
ANNEXURE-II
GUARANTEED TECHNICAL PARTICULARS
Cable type
Cable size
No of cores
Voltage rating
Conforming to IS
Conductor
Conductor Material
Conductor Material Flexibility
Shape of Conductor
Standards
Insulation
Material
Nominal insulation Thickness
Inner Sheath /Bedding
Material
Thickness
Armour
Material
Nominal Dia of armour wire
Standards
Overall / Outer Sheath
Material
Min. Outer sheath thickness
Approx over all dia of cable
Electrical Parameters
Maximum. D.C. resistance/km of conductor at 20 deg.C
AC resistance/kilometer of conductor at 90 deg.C(approx.)
Reactance/kilometre (approx.)
Capacitance/Kilometre (approx.)
Normal Current rating.
Ground
Short circuit current rating for 1 second duration
Operating Temperature
Short circuit Temp
FR-LSH PROPERTIES
Oxygen Index
Temperature Index
Smoke density rating
Acid gas generation (HCL)
Flammability test
Drum Details
Drum Material & standards
Standard Drum Length
Sequential length marking
Embossing on Outer Sheath
Approx Wt.of Cable
Bidders Signature
GUARANTEED TECHNICAL PARTICULARS (GTP) Annexure 19A
Guaranteed Technical Particulars(GTP) for 1100V Grade,4Cx10Sq.mm aluminium, PVC insulated , Galvanized steel wire Armoured , LT Power Cable
Cable type
Cable size
No of cores
Voltage Rating
IS Standard
7. Conductor
8. Insulation
9. Armour
10. Overall / Outer Sheath
Minimum bending radius
Colour of sheath
Safe Pulling force
Approx overall dia of cable
11. Electrical Parameters
Normal Current rating.
Short circuit current rating for 1 second duration
Max. rated conductor temp
Max. allowable conductor temperature during short circuit
Continuous Current carrying capacities for conditions:
i)Air Temperature
ii)Ground Temperature
iii)Depth of laying
a) In Ground
b) In Air
FR-LSH PROPERTIES
Binder/Tapes
Drum Details
Approx Weight of Cable
Methods of Test for Cables
Furnish copy of Type test certificate not more than 5 years from the date of subject Notice Inviting Tender of similar cable for having Tested at CPRI or equivalent athority for conforming its performance as per relevent standards specified in the above GTP,Type Tests list and Technical specification for the subject cable indicated in the subject Tender.
Tests
Executive Engineer (MSP) Jog, Karnataka Power Corporation Ltd Jogfalls-577435
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
GTP 22 A LT Cable Shiva.xlsx
Tender Document • 0.02 MB
GTP 20 A LT Cable Shiva.xlsx
Tender Document • 0.02 MB
Bid document IND2479.doc
Tender Document • 0.28 MB
GTP 15 A LT Cable Shiva.xlsx
Tender Document • 0.02 MB
GTP 2A HT Cable Shiva.xlsx
Tender Document • 0.02 MB
GTP 21 A LT Cable Shiva.xlsx
Tender Document • 0.02 MB
GTP 3 A LT Cable Shiva.xlsx
Tender Document • 0.02 MB
Brief bid notification IND2479.doc
Tender Document • 0.07 MB
GTP 19 A LT Cable Shiva.xlsx
Tender Document • 0.02 MB
Section III IND2479.docx
Tender Document • 0.06 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .