Loading…
Loading…
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
6 Oct 2026, 6:00 pm
GE (West) Jabalpur
Garrison Engineer (West) Jabalpur Supply Marg Post Box No. 54 Jabalpur Cantt-482001 (MP)
MAINTENANCE OF INTERNAL ELECTRIC SERVICES AND ALLIED WORK IN AOR OF MH, MDC, ECHS UNDER GE (W) JABALPUR
2026_MES_789462_1
9081/E8
Open Tender
Civil Works
Item Rate
180 days
GE (West) Jabalpur
As per tender documents
6 documents required · 6 mandatory
₹500
GE (West) Jabalpur
₹80,000
15 Sept 2026
15 Sept 2026
13 Oct 2026
16 Sept 2026
6 Oct 2026
29 Sept 2026
16 Sept 2026 - 24 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| - | Taking down carefully any type of old unserviceable point wiring copper or aluminium conductor (light, fan, socket, bell or power) point complete with fittings such as switches, ceiling roses, lamp holders, sockets, fan regulators, call bell, light fittings with PVC conduit surface / concealed or wooden battens including sunken cast iron / pressed steel terminal boxes etc complete all as specified & directed .
(Note: Painting work shall be measured and paid seperately under respective items.) | 1,089 | Per Point | - | - |
| - | Taking down carefully any type of old unserviceable submain wiring with PVC conduit surface / concealed or wooden battens etc complete all as specified & directed . | 620 | RM | - | - |
| - | M&L for sub main wiring with two runs of single core FRLSH PVC insulated, unsheathed, mutistranded copper conductor cable of size 4.0 sqmm drawn in and including rigid PVC conduit medium grade ISI marked not less than 20mm dia with its accessories, concealed type, including one run of single core FRLSH PVC insulated, unsheathed, multistranded copper conductor cable of size 4 sqmm as earth continuity and cutting chases as per standard engineering practice & making good the disturbed surfaces as per existing finish complete all as specified & directed.
Notes:-
(i) Finished sub main wiring with two runs of 4.0 sqmm cable & one run of 4 sqmm cable alongwith PVC conduit and its accessories shall be measured and paid as one unit length.
(ii) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
(iii) Colour coding for wiring/ bus bar/ main connection shall be followed . | 450 | RM | - | - |
| - | M&L for sub main wiring with two runs of single core FRLSH PVC insulated, unsheathed, mutistranded copper conductor cable of size 6.0 sqmm drawn in and including rigid PVC conduit medium grade ISI marked not less than 25mm dia with its accessories, concealed type, including one run of single core FRLSH PVC insulated, unsheathed, multistranded copper conductor cable of size 6 sqmm as earth continuity and cutting chases as per standard engineering practice & making good the disturbed surfaces as per existing finish complete all as specified & directed.
Notes:-
(i) Finished sub main wiring with two runs of 6.0 sqmm cable & one run of 6 sqmm cable alongwith PVC conduit and its accessories shall be measured and paid as one unit length.
(ii) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
(iii) Colour coding for wiring/ bus bar/ main connection shall be followed . | 120 | RM | - | - |
| - | M&L for sub main wiring with two runs of single core FRLSH PVC insulated, unsheathed, mutistranded copper conductor cable of size 10.0 sqmm drawn in and including rigid PVC conduit medium grade ISI marked not less than 25mm dia with its accessories, concealed type, including one run of single core FRLSH PVC insulated, unsheathed, multistranded copper conductor cable of size 10 sqmm as earth continuity and cutting chases as per standard engineering practice & making good the disturbed surfaces as per existing finish complete all as specified & directed.
Notes:-
(i) Finished sub main wiring with two runs of 10.0 sqmm cable & one run of 10 sqmm cable alongwith PVC conduit and its accessories shall be measured and paid as one unit length.
(ii) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
(iii) Colour coding for wiring/ bus bar/ main connection shall be followed . | 50 | RM | - | - |
| - | Material & Labour for point wiring with three layer PVC Insulated 1.5 Sqmm multi-strand copper conductor FRLSH cable 1100 Volts grade drawn into and concealed PVC conduits medium grade not less than 20mm( ISI marked) including all fitting and fixing accessories including 1.25 mm thick sunken pressed steel terminal boxes/Modular metal flush box duly painted with two coats of anti-corrosive paint outside and two coats of aluminium paint inside with and including 3mm thick hylam brand laminated white bakelite sheet cover for mounting switches, sockets, fan regulators fixed with CP screws with cup wahsers and PVC insulated 1.5 Sqmm multi-strand copper conductor cable as earth wire and making good the disturbed surfaces with cement sand mortar 1:3 to match with the existing surfaces complete all as specified & directed by Engineer-in-charge for One light Point controlled by one switch. | 450 | Per Point | - | - |
| - | ….do…. but for one Fan Point controlled by one switch. | 60 | Per Point | - | - |
| - | ….do…. but for one Bell Point controlled by one switch. | 15 | Per Point | - | - |
| - | ….do…. but for one socket point 5 Amp controlled by one switch on same board. | 50 | Per Point | - | - |
| - | ….do…. but for one socket point 5 Amp controlled by one switch on Independent board. | 50 | Per Point | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.23 MB
9081GP.pdf
Tender Documents • 0.41 MB
Tender9081SPPS.pdf
Tender Documents • 1.29 MB
SCH9081.pdf
Additional Documents • 0.09 MB
BOQ_884986.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .