| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.9 LAccepted-AOC 209 210 AGGARWAL TOWER PLOT NO 2 SECTOR 5 ROHINI NORTH WEST DELHI DELHI 110085 | DELHI | NORTH WEST DELHI | DELHI | 110085 | L1 | Accepted-AOC L1 | |
| 2 | L2₹27.9 L+₹4.0 L (16.7%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | Rejected-Technical 5 B 2 1ST FLOOR OPP METRO PILLOR 484 TILAK NAGAR DELHI 110018 | WEST | DELHI | 110018 | - | Rejected-Technical OEM Not attached |
Tender Value
₹31.4 L
EMD Value
₹62,870
Closing Date
8 Aug 2022, 5:00 pmClosed
Amit Goyal
XEN(E)
Construction of District Head Quarter office building for Excise and Taxation Department in Sector-19 Rewari (Pdg. Fire Alarm and PA system only)
2022_HRY_214586_3
PWD/HRY/MAR-012
Open Tender
Electrical Works
Works
90 days
XEN(E)
Refer DNIT
2 documents required · 2 mandatory
₹5,000
₹62,870
13 Jan 2023
20 Jul 2022
9 Aug 2022
20 Jul 2022
8 Aug 2022
20 Jul 2022
Amount
SITC of Micro processor based 2 wire fault tolerant, networkable type fire alarm/ detection control panel having no. of 2 loops to suit minimum 20% extra over the no. of fire detectors. The panel shall be able to give location of all fire/ fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON/ OFF respective control module when ever any fire alarm is triggered. The panel shall have rectifier, loop cards, minimum 160 character LCD units/5.7” TFT to indicate Fire/ fault signal with address analog input, external/ inbuilt printer to log all fire or fault events complete in all respects. The panel shall be sheet steel power coated, sealed to IP30. The panel shall have 20 zones with individual LED indicators, expandable 80 LED indicators. The Panel shall have 3 Serial Ports. The panel shall have built in power supply and battery charger along with maintenance free 24 AH.2 X 12 volt SMF lead acid batteries capable of running for a minimum of 24 hours with battery charger complete as required and confirming BS5839 standards and duly approved by EN 54/UL/VDS as per specifications complete in all respect up to the entire satisfaction of Engineer-in-charge of work Makes:- BOSCH FPA 1000 series, Cerberus by Siemens, EATON, Honeywell Morley DXE Series.
SITC of Analog Addressable type active repeater fire alarm panel with backlite LCD Display, having controls for reset, mute, accept, silence alarms and self rest conforming to BS5839 standards and duly approved by EN54/UN54/VDS with all labour and material required to complete the job in all respect up to the entire satisfaction of Engineer-in-charge of the work. Make:- BOSCH FMR-1000-RCMD, Cerberus by Siemens, Morley ZxRA, EATON.
SITC of addressable multi sensor smoke detector with a combination of Optical & thermal including mounting base, auto addressing feature as required. Detector should have 2 as per NFPA 72 style 7 wiring requirement (One for incoming and one for outgoing line) for maintaining operational availability of all elements in loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in according with EPSG agreement EPSG/F/97/005. Detectors should monitor shall be 50 V/m shall be EN54/ VD/UL certification. (Detectors without in built isolators may be considered with an additional isolator Module after 20 devices) (Makes: Bosch FAP-440-T-FAA-440, Siemens, Cerberus OH921-DB-11, Honeywell Morley HM-PTSE+B501, EATON
SITC of addressable heat detector with fixed and rate of raise feature including mounting base with LED etc. complete as required. Each detector should have as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirement. High resistance to electromagnetic effects in accordance with EPSG agreement EPSG/F/97/005. Detector should monitor Electromagnetic interference and report in panel-current and average values. EMC safety for detector shall be 50V/m. Shall be EN54 VSs/UL certification (Detectors without in built isolators may be considered with an additional isolator module as per detector) (Make:- BOSCH FAG-440+FAA-440, Siemens Cerberus H1921+B-11, Honewell Morley HM-RHSE+B501, EATON
Supply Installation Testing Commissioning of UL/EN54/LPCB listed and FM approved line isloating for isolation the section of circuit in case of short in the addressable loop wiring (Make: Bosch / Siemens Cerberus/ Morley / EATON
SITC of intelligent analog addressable type Manual Call point having surface or flush mounting option fully compliant to EN54 having rotary decade switches for addressing with back box for mounting as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect upto the entire satisfaction of Engineer-in-Chage of the work. Make Siemens cerberus/ Morely/ EATON/Bosch.
SITC of Intelligent Analog Addressable type Response Indicator with all labour and material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work Make Siemens cerberus/ Morely/ EATON/Bosch.
SITC of Addressable Loop powered sounder with strobe/ flasher complete with mounting base as required performing to BS5839 standards and duly approved by EN54/DU/VDS required to complete the job in all respect up to the entire satisfaction of Engineer-in-charge of work Make:- BOSCH/ Siemens/ Cerberus/Morley/ EATON.
SITC of glow type EXIT Sign board photo luminescent of size 300mm x 250mm x 1.5mm rigid sheet signage containing Zink sulphate as bare chemical class-1 material PSPA fixed on 3mm acrylic sheet on both side showing marking (running man, arrow and Exit) and hanged with the ceiling with chain and fastener including cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer-in-charge of work. Make PES/Glolite/OMEX/ EATON
SITC of Addressable control relay module with flexible network structure with a maximum switching current of 1A @ 30V DC shall be EN54/UL/VDS certification Make BOSCH, Siemens/ Cerberus/ Morley/ EATON.
SITC of addressable monitor module for monitoring of a line with EOL resistor/ Potential free contact/ voltage monitoring shall be EN54/UL/VDS approved (In case of 2 Monitoring features in one module (points) each point shall be consider separately for payment) Makes: BOSCH FLM-325-214, Simens, Cerberus HTRI-M, Morley MI-DMMI, EATON.
SITC of minimum 1000 mtr. range Siren generator provided at the proof of the building with separator power supply relay etc. with all accessories required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work Make:- National/ Kheraj
Supply and erection of Fire Extinguishers duly hang on wall with necessary hook complete in all respect Make Safex, Minimax, Ceasefire).ABC dry power type fire extinguishers of 5 Kg Capacity.
Co2 type extinguishers of 4 Kg Capacity.
SITC of booster amplifier 480 watts frequency response 60 Hz to 15 Khz (+1/3dbi), inputs, XLR & input jack, input 2-4, impendence, 20 K, sensitivity, 1V balanced, S/N >;> 85dB complete in all respect Make:- Honeywell/ BOSCH/ Heinrich
SITC of Horn Loudspeaker made with ABS, watrand dust protected to IP65, Sound pressure level at 15W/7.5W, 115/103dB (SPL), Effective frequency range 500 Hz to 5 KHz, rated power 15W Make BOSCH/ Heinrich/Honeywell.
SITC of Wall / ceiling mount speaker with operation 6 watts with tapping of 6W/3W/1.5W Make Honeywell/BOSCH/ Heinrich
Supply and erection of 2core 1.5sqmm copper cable with all accessories required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work Make:- Havells/ Finolex/RR Kabel
HSR 23.1.6.6Wiring main ,sub mains and Circuit wiring in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in MS Conduit etc as required2 run of Size 1.50 Sqmm(1/1.40mm)
HSR 23.7.6Supply and erection of PVC CONDUIT ISi marked (Medium) recessed in walVceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of workPVC pipe of 20 mm dia
PVC pipe of 25 mm dia
PVC pipe of 32 mm dia
PVC pipe of 40 mm dia
HSR 23.23.10Supplying and drawing of 1 no UTP 4 pair CAT Sa LAN Cable in the existing surface/recess MS/PVC conduit as required
Shree Krishna Safety Vision
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .