GEMC-511687763159113
Awarded to Convergent Technologies
₹10.0 L
Products
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| 6 GHz VNA Master - MS2026C | Anritsu & MS2026C+15NNF50-1.5C (2e.a)+TOSLN50A-8 | - | 1 NOS | ₹10.0 L | 996,000 |
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹10.0 LQualified Make: Anritsu
Model: Anritsu & MS2026C+15NNF50-1.5C (2e.a)+TOSLN50A-8 204 CONVERGENT TECHNOLOGIES 2ND MAIN MAHALAKSHMI LAYOUT BANGALORE KARNATAKA 560086 | BENGALURU URBAN | KARNATAKA | 560086 | Make: Anritsu
Model: Anritsu & MS2026C+15NNF50-1.5C (2e.a)+TOSLN50A-8 | ₹10.0 L | L1 | Qualified |
| 2 | L2₹10.4 L+₹44,000 (4.42%)Qualified Make: Keysight Technologies
Model: Keysight N9914A with options Vector T/R, S-Parameter, Cal Kit, Cable E 366 2ND FLOOR NIRMAN VIHAR VIKAS MARG VIKAS MARG VIKAS MARG NEW DELHI DELHI 110092 | EAST DELHI | DELHI | 110092 | Make: Keysight Technologies
Model: Keysight N9914A with options Vector T/R, S-Parameter, Cal Kit, Cable | ₹10.4 L+₹44,000 (4.42%) | L2 | Qualified |
| 3 | L3₹11.4 L+₹1.4 L (14.3%)Qualified Make: Anritsu
Model: Anritsu & MS2026C+15NNF50-1.5C (2e.a)+TOSLN50A-8 6TH FLOOR K S CORPORATE TOWER PLOT NUMBER 24B FILM CITY SECTOR 16A NOIDA GAUTAM BUDDHA NAGAR UTTAR PRADESH 201301 | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201301 | Make: Anritsu
Model: Anritsu & MS2026C+15NNF50-1.5C (2e.a)+TOSLN50A-8 | ₹11.4 L+₹1.4 L (14.3%) | L3 | Qualified |
| 4 | Disqualified Make: Rohde & Schwarz
Model: Rohde &Schwarz ZVH8 A27 FIRST FLOOR MOHAN CORPORTAIVE INDUSTRIAL ESTATE MATHURA ROAD NEW DELHI DELHI 110044 | SOUTH EAST DELHI | DELHI | 110044 | Make: Rohde & Schwarz
Model: Rohde &Schwarz ZVH8 | - | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
7 Aug 2018, 5:00 pmClosed
spectrum analyzers vector network analyzers Experience with Gov. Required 5 Year (s) Spectrum Analyzers Vector Network Analyzers ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values FEATURES Description of the itemuu Two port vector network analyzers (without spectrum analyser) Spectrum analyzers
Two port vector network analyzers(with spectrum analyser)
Two port vector network analyzers (without spectrum analyser) GENERAL FEATURES COMMON TO SPECTRUM AND VECTOR ANALYSER Markers Normal
delta - Trigger Free run
External - Display TFT Colour display - Interface USB
LAN - Software for transfer of screen shot/measurement data to PC Yes - SPECTRUM ANALYZER FEATURES Frequency Range NA 9 kHz to 3 GHz
9 kHz to 7 GHz
9 kHz to 13 GHz
100 kHz to 18 GHz
9 kHz to 26.5 GHz
9 kHz to 40 GHz
9 kHz to 6 GHz
NA Aging rate of spectrum NA - 1/6 analyzer frequency: Better than 1x10-6 Year Frequency counter Resolution(minimum) (Hz) NA - Frequency Span NA As per GeM Catalogue. Spectral purity:SSB Phase Noise @10KHz offset shall be less than -90dBc/Hz at 1GHz NA - Spectral purity:Harmonics @ -40dBm level <=60 dBc NA - Sweep time @span >or= 1 KHz NA - Sweep time @span = 0 Hz NA - Resolution Bandwidth (-3dB) NA - Video Bandwidth NA - Amplitude : Max input level for protection (dBm) NA - Amplitude : Max input level for measurement (dBm) NA - Amplitude :level measurement uncertainity (dB) NA - Average noise level dis played(@300HzRBW
10 Hz VBW) NA - Average noise level dis played(@100HzRBW
1 Hz VBW) NA - Average noise level dis played(@300HzRBW
1 Hz VBW) NA - Measurement features NA - VECTOR NETWORK ANALYZER FEATURES Frequency Range for 2port vector network analyzer 2 MHz to 6 GHz - Frequency Resolution (CW ON) (Hz) 10 - Return Loss (dB) 0.00 to 60 - 2/6 VSWR (dB) 1.01 to 10.00 - Cable Loss (dB) 0.00 to 30.00 - Calibration with Precision calibration components-open
short
load should be included to achieve directivity >35 dB Yes - Abilty to locate Distance-to-fault in Co- axial cables yes - Phase Range (degree) -180 to +180 - Phase Resolution (deg) 0.01 - RF output port Type N
female
50Ohm - Dynamic Range 60 - Nominal port power output: Hi Power/Lo- Power selectable yes - Power levels corresponding to Hi and Lo levels 5 kHz to < 3 GHz: HI: +3dBm
LO: –25dBm`
3 GHz to 6 GHz: Hi: -3dBm
LO:–25dBm - Measurement of S11 and S21 and Smith Chart Yes - Vector Voltmeter for comparision and verification of the phase of the phase- matched cables NA - Group Delay measurement < 180º of phase change within the aperture - OPERATING CONDITIONS Operating Temperature '5 to 40 degree C & 80% RH @ 40 degree C '5 to 40 degree C & 80% RH @ 40 degree C Operating Humidity 80% RH @ 40 degree C 80% RH @ 40 degree C POWER REQUIREMENT Power requirement 230 +- 10 VAC
50Hz
Rechargeable battery 230 +- 10 VAC
Rechargeable battery chemistry of the battery lithium ion - Voltage of rechargeable Battery 10.8 - capacity of rechargeable battery (millAh) 7500 - Suitable charger Yes - 3/6 adaptor provided WARRANTY Warranty 3 1
2
3
4
5 ACCESSORIES Details of Standard accessories covered in the scope of supply 2000-1685-R Soft Carrying Case
633-75 Rechargeable Li-Ion Battery
40-187-R AC- DC Adapter
806-141-R Automotive Power Adapter
12 VDC
60 W
3-2000-1498 USB A/5-pin Mini-B Cable
3.05 m (10 ft)
2000-1371-R Ethernet Cable
2.13 m (7 ft)
Certificate of Calibration and Conformance - GENERIC Other features Features - Two-active- port
fully-reversing VNA
Measures all four S-parameters with a single connection. 3-receiver architecture for higher measuring speed
12-term error correction algorithm. User-configured 4-quadrant display for up to four S- parameters. Supports waveguide measurements
and SOLT
SSLT and SST calibrations. New Polar Impedance display. Transmission Dynamic Range 2 MHz to 3 GHz
100 dB
3 to 6 GHz
90 dB. 350 sec per data point sweep speed
ideal for fast filter tuning. Store more than 13
000 traces and setups in memory . High resolution daylight viewable TFT color display. Built-in editable Cable and Signal Standard List. Options - MS2026C - VNA Master
2-port
5 kHz - 6 GHz Qty 1
TOSLNF50A-8 - Coaxial Calibration Kit
Type Nf
DC to 8 GHz
50 Qty 1
15NN50-1.0B - Test - 4/6 Port Extension Cable
Armored
Phase Stable
1.0 meter
DC to 18 GHz
Nm - Nm
50 Qty 2.. CERTIFICATION/TEST REPORT DETAILS The equipment supplied with calibration certificate yes - conformity to Dry Heat for 16 hrs at a specified maximum temp in accordance with IS:900 0/part-3/section-5/1977 latest no - conformity to Cold Test for 4 hrs at a specified minimum temp in accordance with IS:900 0/part-2/section-4/1977 latest no - conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 h each at a temp of 40 degree C & 95% RH no - Availability of Test Reports from Central Govt/NABL/ILAC approved accredited lab to prove conformity to the specification true - Test Report Number and date for the specification test - - Name and address of the Lab for the specification test - - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 P V Raghu Ram N 560058
ISTRAC/ISRO
Plot No. 12 and 13
III Main
II Phase
Peenya Industrial Area 1 30
348198
GEM/2018/B/49333
GeM Contract
spectrum analyzers vector network analyzers
GeM Contract
30 days
Karnataka; Bengaluru Urban
PRODUCT
Awarded to Convergent Technologies
₹10.0 L
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| 6 GHz VNA Master - MS2026C | Anritsu & MS2026C+15NNF50-1.5C (2e.a)+TOSLN50A-8 | - | 1 NOS | ₹10.0 L | 996,000 |
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| spectrum analyzers vector network analyzers Experience with Gov. Required 5 Year (s) Spectrum Analyzers Vector Network Analyzers ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values FEATURES Description of the itemuu Two port vector network analyzers (without spectrum analyser) Spectrum analyzers | - | - | - |
| Two port vector network analyzers(with spectrum analyser) | - | - | - |
| Two port vector network analyzers (without spectrum analyser) GENERAL FEATURES COMMON TO SPECTRUM AND VECTOR ANALYSER Markers Normal | - | - | - |
| delta - Trigger Free run | - | - | - |
| External - Display TFT Colour display - Interface USB | - | - | - |
| LAN - Software for transfer of screen shot/measurement data to PC Yes - SPECTRUM ANALYZER FEATURES Frequency Range NA 9 kHz to 3 GHz | - | - | - |
| 9 kHz to 7 GHz | - | - | - |
| 9 kHz to 13 GHz | - | - | - |
| 100 kHz to 18 GHz | - | - | - |
| 9 kHz to 26.5 GHz | - | - | - |
| 9 kHz to 40 GHz | - | - | - |
| 9 kHz to 6 GHz | - | - | - |
| NA Aging rate of spectrum NA - 1/6 analyzer frequency: Better than 1x10-6 Year Frequency counter Resolution(minimum) (Hz) NA - Frequency Span NA As per GeM Catalogue. Spectral purity:SSB Phase Noise @10KHz offset shall be less than -90dBc/Hz at 1GHz NA - Spectral purity:Harmonics @ -40dBm level <=60 dBc NA - Sweep time @span >or= 1 KHz NA - Sweep time @span = 0 Hz NA - Resolution Bandwidth (-3dB) NA - Video Bandwidth NA - Amplitude : Max input level for protection (dBm) NA - Amplitude : Max input level for measurement (dBm) NA - Amplitude :level measurement uncertainity (dB) NA - Average noise level dis played(@300HzRBW | - | - | - |
| 10 Hz VBW) NA - Average noise level dis played(@100HzRBW | - | - | - |
| 1 Hz VBW) NA - Average noise level dis played(@300HzRBW | - | - | - |
| 1 Hz VBW) NA - Measurement features NA - VECTOR NETWORK ANALYZER FEATURES Frequency Range for 2port vector network analyzer 2 MHz to 6 GHz - Frequency Resolution (CW ON) (Hz) 10 - Return Loss (dB) 0.00 to 60 - 2/6 VSWR (dB) 1.01 to 10.00 - Cable Loss (dB) 0.00 to 30.00 - Calibration with Precision calibration components-open | - | - | - |
| short | - | - | - |
| load should be included to achieve directivity >35 dB Yes - Abilty to locate Distance-to-fault in Co- axial cables yes - Phase Range (degree) -180 to +180 - Phase Resolution (deg) 0.01 - RF output port Type N | - | - | - |
| female | - | - | - |
| 50Ohm - Dynamic Range 60 - Nominal port power output: Hi Power/Lo- Power selectable yes - Power levels corresponding to Hi and Lo levels 5 kHz to < 3 GHz: HI: +3dBm | - | - | - |
| LO: –25dBm` | - | - | - |
| 3 GHz to 6 GHz: Hi: -3dBm | - | - | - |
| LO:–25dBm - Measurement of S11 and S21 and Smith Chart Yes - Vector Voltmeter for comparision and verification of the phase of the phase- matched cables NA - Group Delay measurement < 180º of phase change within the aperture - OPERATING CONDITIONS Operating Temperature '5 to 40 degree C & 80% RH @ 40 degree C '5 to 40 degree C & 80% RH @ 40 degree C Operating Humidity 80% RH @ 40 degree C 80% RH @ 40 degree C POWER REQUIREMENT Power requirement 230 +- 10 VAC | - | - | - |
| 50Hz | - | - | - |
| Rechargeable battery 230 +- 10 VAC | - | - | - |
| Rechargeable battery chemistry of the battery lithium ion - Voltage of rechargeable Battery 10.8 - capacity of rechargeable battery (millAh) 7500 - Suitable charger Yes - 3/6 adaptor provided WARRANTY Warranty 3 1 | - | - | - |
| 2 | - | - | - |
| 3 | - | - | - |
| 4 | - | - | - |
| 5 ACCESSORIES Details of Standard accessories covered in the scope of supply 2000-1685-R Soft Carrying Case | - | - | - |
| 633-75 Rechargeable Li-Ion Battery | - | - | - |
| 40-187-R AC- DC Adapter | - | - | - |
| 806-141-R Automotive Power Adapter | - | - | - |
| 12 VDC | - | - | - |
| 60 W | - | - | - |
| 3-2000-1498 USB A/5-pin Mini-B Cable | - | - | - |
| 3.05 m (10 ft) | - | - | - |
| 2000-1371-R Ethernet Cable | - | - | - |
| 2.13 m (7 ft) | - | - | - |
| Certificate of Calibration and Conformance - GENERIC Other features Features - Two-active- port | - | - | - |
| fully-reversing VNA | - | - | - |
| Measures all four S-parameters with a single connection. 3-receiver architecture for higher measuring speed | - | - | - |
| 12-term error correction algorithm. User-configured 4-quadrant display for up to four S- parameters. Supports waveguide measurements | - | - | - |
| and SOLT | - | - | - |
| SSLT and SST calibrations. New Polar Impedance display. Transmission Dynamic Range 2 MHz to 3 GHz | - | - | - |
| 100 dB | - | - | - |
| 3 to 6 GHz | - | - | - |
| 90 dB. 350 sec per data point sweep speed | - | - | - |
| ideal for fast filter tuning. Store more than 13 | - | - | - |
| 000 traces and setups in memory . High resolution daylight viewable TFT color display. Built-in editable Cable and Signal Standard List. Options - MS2026C - VNA Master | - | - | - |
| 2-port | - | - | - |
| 5 kHz - 6 GHz Qty 1 | - | - | - |
| TOSLNF50A-8 - Coaxial Calibration Kit | - | - | - |
| Type Nf | - | - | - |
| DC to 8 GHz | - | - | - |
| 50 Qty 1 | - | - | - |
| 15NN50-1.0B - Test - 4/6 Port Extension Cable | - | - | - |
| Armored | - | - | - |
| Phase Stable | - | - | - |
| 1.0 meter | - | - | - |
| DC to 18 GHz | - | - | - |
| Nm - Nm | - | - | - |
| 50 Qty 2.. CERTIFICATION/TEST REPORT DETAILS The equipment supplied with calibration certificate yes - conformity to Dry Heat for 16 hrs at a specified maximum temp in accordance with IS:900 0/part-3/section-5/1977 latest no - conformity to Cold Test for 4 hrs at a specified minimum temp in accordance with IS:900 0/part-2/section-4/1977 latest no - conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 h each at a temp of 40 degree C & 95% RH no - Availability of Test Reports from Central Govt/NABL/ILAC approved accredited lab to prove conformity to the specification true - Test Report Number and date for the specification test - - Name and address of the Lab for the specification test - - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 P V Raghu Ram N 560058 | - | - | - |
| ISTRAC/ISRO | - | - | - |
| Plot No. 12 and 13 | - | - | - |
| III Main | - | - | - |
| II Phase | - | - | - |
| Peenya Industrial Area 1 30 | - | - | - |
Exempted
25 Oct 2018
18 Jul 2018
contract_GEMC-511687763159113.pdf
GEM_CONTRACT • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_348198.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .