27 Jan 2024, 6:00 pmClosed
GE (AF) Borjhar
Garrison Engineer (AF) Borjhar, Military Engineer Services, Guwahati Airport- PO, Borjhar Airport, Guwahati, Assam, Pin- 781015 Tele 0361 - 2840127
Provn of Standby DG Set for production labs / communication / signal eqpt with allied works at 14 BRD, AF
2023_MES_634227_1
8394/BOR/E8
Open Tender
Civil Works - Others
Item Rate
180 days
GE (AF) Borjhar
MES Contractor enlisted as Class D category b(i) having deposited Standing Security of Rs 100000.00 with dept. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category.
7 documents required · 7 mandatory
₹500
GE (AF) Borjhar
₹86,000
Yes
5 Apr 2024
26 Dec 2023
3 Feb 2024
26 Dec 2023
27 Jan 2024
7 Jan 2024
Amount
Excavation in post hole each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, and getting out soft soil complete all as specified and directed
Surface excavation n.exc 30 cm deep and averaging 15cm deep and getting out complete all as specified and directed
M&L for cement concrete 1:3:6 type C-2 (40mm aggregate) columns , pillar and posts etc. complete all as specified and directed
S&F structural steel in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc of grade Fe 410-W (Gde E- 250 quality A complete, all as specified and directed
S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment of grade Fe 410-W (Gde E- 250 quality A complete, all as specified and directed .
M&L for preparation of new steel and iron surfaces of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint of approved tint over a coat of zinc chrome primer, complete all as specified & directed.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete, all as specified and directed .
S&F Pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete, all as specified and directed .
M&L for brickwork with subclass 'B' Bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed .
M&L for rendering 15 mm thick in cement mortar 1:4 to other than fair faces of brick or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed
M&L for cement concrete 1:4:8 type D-2 (40mm aggregate) sub base of floors , mass concrete complete all as specified and directed
M&L for hardcore (broken stone or boulders) of gauge n exc 63mm, deposited, spread and levelled in layers n exc. 15cm thic, watered and rammed to a true surface complete all as specified and directed.
M&L factory made 60mm thick Machine pressed precast cement concrete coloured, rubber moulded, designer(reflecting type) interlocking pavour block of M-35 grade confirming to IS 15658-2006 of shape and size as directed with coloured top laid over and including 50mm thick sand cushioning, joints of blocks filled with dry sand and compacted complete all as specified and dierected
Removal of surplus soil to a distance not excceding 50 mtr away & depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed
M & L Cement concrete type B1 (1:2:4) using 20mm grades stone aggregate as in copings, bed plates, fixing of hold fasts and other similar works and the like incl weathering, slightly rounded or chamfered angles and throating as directed incl use and waste of necessary form work complete all as specified and directed
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth and getting out in soft/loose soil for lying of cable etc complete all as specified and
M&L for returning, filling in, including spreading, watering and well ramming in layers not exc 25cm in soft/loose soil complete all as specified and directed
M&L for removing surplus soil to a distance not exc 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed
Material and labour for sand cushioning for under ground cable with locally available sand for protection of cable including spreading and consolidations, complete all as specified and directed.
Supply and laying in trenches dry well burnt locally available sub class “B” bricks over sand cushioning for protection of cable complete all as per specified and directed.
M&L for tubes 80 mm bore light grade galvnized with all fittings laid in trenches/wall/ pole through MS flat (25x3 mm) nut bolts &washers(where ever required) of proper sizes for protection cabls complete all as specified and directed
Supply and laying heavy duty armoured LT underground cable 1100 V grade XLPE insulated,PVC sheathed multi stranded aluminium cable of sizes 95 Sqmm 3.5 core in pipe/trenches/cable duct/ fixed on wall by proper size of shaped GI clamps with nut bolts etc and making good the disturbed surfaces by cement mortor/painting to match the existing, connecting with all accessories lugs and glands, all as specified and diected.
Supply and laying heavy duty armoured LT underground cable 1100 V grade XLPE insulated,PVC sheathed multi stranded aluminium cable of sizes 120 Sqmm 3.5 core in pipe/trenches/cable duct/ fixed on wall by proper size of shaped GI clamps with nut bolts etc and making good the disturbed surfaces by cement mortor/painting to match the existing, connecting with all accessories lugs and glands, all as specified and diected .
Supply and fix double compression copper stain less steel gland for fixing armoured cable in panel of size 3.5 Core of 95 Sq mm to 120 sq mm size complete all as specified and directed
Supply and fix double compression copper stain less steel gland for fixing armoured cable in panel of size 3.5 Core of 95 Sq mm to 120 sq mm size complete all as specified and directed
M&L for taking out of old unsv cable of any sizes or types for replacement with new one complete all as specified & directed.
M&L for relaying heavy duty LT under ground cable of any size and types in pipe /trench /cable duct/fixed on wall by proper size shaped GI clamps with nut bolts etc and making good the disturbed surfaces by cement mortar /paint to match with the existing surface complete all as specified & directed.
Supply, install, testing and commissioning of servo controlled voltage stablizer indoor type (Confirming to BIS: 815:Part 1:1994,reaffirmed 2009) 3- Phase ,50 Hz, naturally oil cooled, Inddor, Unbalanced Type ,Copper Wound ,Digital Display Type, Relay Smooth and Silent Operation with first filiing Transformer oil (IS335: 1993 reaffirmed 2005) of capacity 200 KVA for unbalanced load with input voltage avriation from 300V-480 V between phase to phase with alarm/protection and by pass facility input voltage & current etc. and comprised of digital multi function meter complete including platform as per manufacturer's norms with the undermentioned features as mentioned below. 1) Input voltage avriation from 300V-480 V 2) Output voltage stablized at any designed/desired voltage 415 +- 1% (Adjustable) 3) Rated frequency 50 Hz. 4) No distoration in wave form. 5)Response time not to exceed 10 mille second. 6) Sensitivity (+-) 1%. 7) Rate of correction 8 volts/second for single phase and 20 volt/second for phase to phase. 8) No Load losses less than 0.5%. 9) Fill load losses than 2.5%. 10) Duty cycle - continuous 24 x 7. 11) Efficiency more than 95% 12) Type of load :3 Phase ,unbalanced type. 13) Digital display Voltmeter /Ampmeter.1 14) Capacity :- 200 KVA 15) Make- Volina. PROTECTIONS:- 1. Over load/short circuit protections 2. High/Low voltage cut off. 3.By Pass arrangement in case of emergency. 4. Single phase sequence change protection. OPTIONAL PROTECTION:- Ingress Protection (IP) up to IP42//IP 45 a) Physical examination b) Insulation resistance c) High voltage test d) Leakage current test e) Provision for earthing f) Output voltage g) No load current h) Mesurement of no load losses j) Inducted voltage test.
M & L for earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick, burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less 1.5 mtr deep below normal ground level connected to GI strip 32 X6 mm as earthing lead connected to earth plate by means of nut, bolts, check nut & washer of galvanized iron or of steel, GI earth wire will be protected by 40 mm dia GI pipe 'light grade', watering pipe 20 mm dia GI 'light grade', GI wire meshed funnel, alternate layer of char coal and salt on all side to earth plate upto thickness of 150 mm, filling of black cotton soil in earth pit upto ground level, PCC chamber recessed for and including RCC cover including all necessary excavation & earth work, earth wire connected to O/H continious earth wire on pole, testing the earthing after completion all as specified and directed .
M & L for earthing complete with using copper plate 60×60cm ×3.15mm thick electrode and 20×3mm copper strip as earthing leadburried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less 1.5 mtr deep below normal ground level connected to Copper strip 20x3 mm as earthing lead connected to earth plate by means of nut, bolts, check nut & washer of galvanized iron or of steel, copper earth strip will be protected by 25 mm dia GI pipe 'light grade', watering pipe 20 mm dia GI 'light grade', GI wire meshed funnel, alternate layer of char coal and salt on all side to earth plate upto thickness of 150 mm, filling of black cotton soil in earth pit upto ground level, PCC chamber recessed for and including RCC cover including all necessary excavation & earth work, earth wire connected to O/H continious earth wire on pole, testing the earthing after completion all as specified and directed .
M&L for boring under roads without disturbing the top surface of the road for throughing the cable complete all as specified and directed by Engr-in-Charge
Supply, erecting, testing and commissioning complete of manufacturer or OEM manufactured, silent type Diesel Engine Driven Generating Set capable of delivering 160 KVA, water cooled, 415 Volts (AC Three phase, 4 Wire system of supply) 50 HZ at power factor 0.8 minimum. The DG Set shall consists of diesel engine coupled to a matching alternator, through flexible coupling and mounted on common base frame and complete with engine control panel and AMF panel , fuel tank with mounting arrangements and exhaust pipe complete and for conditions prevalent at AF Station Borjhar including PCC foundation( of suitable size leaving at least 1.00 M all around for ease of movement and 1.5 M height), anti-vibration pads, including all features to comply with latest CPCB guidelines and Comprising of followings:-
ENGINE(Prime Mover): Diesel Engine 1500 RPM , direct injection ,6 cylinders ,four stroke, confirming to ISO3046/BS 5514, water cooled,turbo charged BHP to drive Alternator capable of delivering 160 KVA at outdoor atmospheric conditions at AF station Borjhar asking all derating factor into consideration),12/24 Volt(as per manufacturer recommendations) electric battery start including Battery as recomended by OEM complete with fly wheel all standard fittings/fixtures as per manufacturer recommendation and including suitable panel with tachometer, lub oil temperature, pressure gauge and frequency meters and also including self starter system, dynamo, fuel electric control panel with electronic governor and Engine protection system(shut down, high water temperature, low lub oil, oil pressure, over speed etc) fuel tank and first fill of lub oil and other consumables etc. Engine should conformly latest CPCB norms for ,emmission control ie (i) Nox+HC <04.0 ii) CO< 0.2 iii) PM,0.3 iv) Smoke limit (light absorption co-efficient,m-1<0.7
Alternator: Brushless AC alternator, 3 Phase, 415 Volt, 4 wire, rated for output of 160 KVA, Minimum power factor 0.8, 1500 RPM, IP 23 Protection class enclosure, insulation Class "H", salient pole, revolving field, single bearing automatic voltage regulator coupled through flexible coupling with and to match the above engine.Applicable standards IS 4722/BS 5000.
BASE PLATE: made out of structural steel as per manufacturers recommended design/specifications.
(ACOUSTIC ENCLOSURE: Sheet metal fabricated cope type silent enclosure manufactured on CNC machines as per CPCB norms and powder coated after seven tank process, the enclosure shall be designed for reducing the sound level to 75 DB (A) at a distance of 1 M at 75 % load under field condition and ox, 70DB at 3 M from Gen set when DG set is working at full load along with testing conformance, labeling certification etc as laid down in GSR No 371(E) dt 17 May 2002..
Foundation/Plinth/Base: Shall be provided as per manufacturers recommendations, however minimum 1.0 m Space should be available all around the DG Set.
Diesel storage tank of capacity adequate for storage of diesel for 12 hours operation og Gen Set.
MISC: Tool kit, Operation and Maintenance catalogue, spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices.
PURBANCHAL BUILDERS
KUNDAN ENGINEERS AND BUILDERS
M/S PANKAJ SUPPLY SYNDICATE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .