Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹57.7 LAccepted-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L1 | Accepted-AOC Being Lowest Tenderer | |
| 2 | L2₹66.9 L+₹8.1 L (13.8%)Rejected-Finance | L2 | Rejected-Finance Being other than Lowest Tenderer | |
| 3 | L3₹78.9 L+₹20.1 L (34.1%)Rejected-Finance 25 13 1 AMBEGAON PATHAR PUNE 411046 | PUNE | MAHARASHTRA | 411046 | L3 | Rejected-Finance Being other than Lowest Tenderer | |
| 4 | L4₹80.7 L+₹21.9 L (37.2%)Rejected-Finance T 16 1 SHETTY HOTEL OLD NAVY NAGAR COLABA MUMBAI 400005 | MUMBAI | MUMBAI | MAHARASHTRA | 400005 | L4 | Rejected-Finance Being other than Lowest Tenderer |
Tender Value
₹75 L
EMD Value
₹1.5 L
Closing Date
19 Jun 2023, 6:55 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Lt Col Ng Rajesh Singh GE NW KUNJALI
GARRISON ENGINEER NW KUNJALI DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI 400005
8963 REPAIR TO ROOF COVERING PLINTH PROTECTION AND OTHER BR NATURE WORK AT NAVAL DOCKYARD MUMBAI
2023_MES_596767_1
8963/E8
Open Tender
Civil Works
Item Rate
270 days
GE (NW) KUNJALI
ALL AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹1,000
Yes
GE (NW) KUNJALI
₹1.5 L
Yes
22 Oct 2023
19 May 2023
21 Jun 2023
26 May 2023
19 Jun 2023
31 May 2023
19 May 2023 - 26 May 2023
Amount
Complete removal of existing water proofing treatment of any description in any position including cleaning, wire brushing, watering, removal of debries upto 1500 mtr distance as directed by Engineer-in-charge complete all as specified and as directed.
M&L for Wire brushing and cleaning top surface of roof or cement concrete,including flashings and junction of parapets, etc., and surface painting, with a layer of blown grade bitumen of any penetration applied hot @ 1.7 kg per sq. m, blinded with grit or pea size gravel @ 0.006 cu.m per sq.m, and lightly tampered (area of flashings, etc., shall be added to the roof area) complete all as specified and directed by EIC.
M&L for 100mm thick PCC (1:2:4) type B-1 (Using 20mm graded stone aggregate) as in roof/chajja padding for maintining roof/chajja slope complete all as specified and as directed by EIC.
M&L for laying chicken wiremesh of galvanised steel 0.7mm dia of wire having mesh size 25x25 fixing by using battens of approved makes complete all as specified & as directed by EIC.
M&L for rendering 20mm thick cement plaster in CM (1:3) on roof top surface finished even and fair including WPC by weight of 3% of total weight of cement in concrete complete all as specified and as directed. Note : WPC will be measuerd and paid separately.
Supply only integral water proofing compound (3% by weight by cement).
M&L for preparing plastered surface of roof slab, chhajjas etc, by brooming with broom sweeping free from dirt dust etc and evenly applying a coat of approved bituminous primer @ 0.20 Kg/Sqm of area complete all as specified and diretced by EIC.
M&L for APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) laid on primed surface by torched application method complete all as specified and directed by EIC. Note : 1. The side overlaps shall be minimum 75mm and the end laps shall be minimum 100 mm. All overlaps and joints shall be sealed as per manufacturer’s instructions 2. the membrane shall be inserted in the wall at the height of 300 mm by cutting groove in the wall finished by membrane flashing.
M&L for cement concrete tiles 30cmx30cmx22mm thick, machine pressed (with grey cement & pigments) set jointed and pointed in neat cement slurry in floors over and including 15mm thick bedding layers in CM 1:3 complete all as specified & as directed by EIC.
Material and labour for taking down , chipping and removing the loose, spailt, damaged cement concrete, cement mortor surfaces of RCC Columns, beams, walls, chajjah etc and exposing the reinforced cement , wire brushing and cleaning the exposed steel reinforced bar, applying rust remover over the cleaned re-bar surface wash the re-bar with clean water for removing all rusts from the old re-bar surfaces, fixing new reinforcement for strengthen the members as required, applying two coats of epoxy zinc primer on new and old steel surfaces, saturate the substrate with water applying one coat of polymer modified bond coat on affected concrete surfaces and finally providing polymer modified cement and quartz sand mortor in CM (1:3) mix, 40mm thk in two coats, using polymer @ 15% by weight of cement complete all as specified and directed. Note :-(New reinforcement and MS Sections will be measured and paid separately) Make : Dr. Fixit/Sunanda/chemestik/Fosrok
Drilling of hole 12 mm dia and depth 110 mm dia in brick masonry, after cleaning hole with electric blower and brush, filling hole with dispencing chemical HDM -500 dispencer up to 75% of whole volume with injectable mortar HIT-HY 70 330/2 or equivalents items in Ramset, G E Brand, inserting threaded anchor rod HAS-E RM 10/90/61 of HILTI item No 333123 or equivalent items in Ramset, G E Brand , allow to setup to rest towards including testing.
M&L for Chipping , removing carefullly concrete work by low impact hammer ,breakar without damaging the structure & cleaning and disposal of debries out side the premises etc. complete as directed by Engr-in-Charge. Hard concrete should not be removed by force.
M&L for Cleaning existing reinforcement with wire/rotary wire brush, making the surfaces free from loose material dirt etc, complete, applying two coats of alkaline rust converting primer FEOVERT confirming to ASTM-B-117, on the rebars, including cleaning the reinforcement, wire brushing to remove loose rust spalls, with time interval of 6 hour between the coats and applying protective coating IPNET-RB complete all as specified and directed.
M&L for providing and applying structural grade EPIBOND-21-LP prior to application of any type of mortar plaster confirming to ASTM-C-882-91 (Arizona slant shear Test) to ensure bond between old concrete and new concrete.
M&L for Building up the profile of structural members by using latex additives (MONOBOND) modified air cured mortar system (Polymer modified mortar) (1:5:15 = 1 monobond-5Cement-15 sand) -in damaged areas in 30mm thickness including leveling profiling etc complete
M&L for rendering 20 mm thick pre polymer modified ready mixed cement based plaster in two coats 12 mm thick base coat and 8 mm thick finishing/final coat. Polymer modified ready mixed cement based plaster should having minimum composition of cement & sand 1:4 using fully treated dry, well graded natural sand conforming to IS-383 suitable for external plastering having low rebound properties, low water demand for curing properties, mechnical mixing with water in a mettalic tray only to made good, consistency as per the specification of the manufacturer and applied over exterior masonry and concrete surfaces complete all as specified and directed.
Taking down cement plaster or cement lime plaster on brick on stone walls etc including raking out joint, hacking for key, scrubbing down with water etc complete all as specified.
M & L for rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 finished even and smooth (with out using extra cement) including Sagol finish complete all as specified using WPC @ 3% by weight of cement (Note: WPC shall be measure and paid seperatly)
All as per item No 18 above but 10 mm thick in CM (1:3) on ceilling.
All as per item No 18 above but 15 mm thick in CM (1:4).
M&L for preparation of new platered wall surfaces of any description & applying two coats of acrylic (antifungal) exterior grade paint on wall/roof including necessary scaffolding complete all as specified and directed
M&L for preparation of old wall surfaces of any description & applying one coats of acrylic (antifungal) exterior grade paint on wall/roof including necessary scaffolding complete all as specified and directed
M&L for Preparation of old decorated surfaces of ceilings / boards by washing, rubbing down and stopping and applying one coat of oil bound distemper (oil emulsion) on wall complete.
M & L for preparing new plastered surfaces of walls and applying two coats of oil bound distemper with priming plastered and other surfaces with alkali resistant primer with 3mm thk wall care putty on plastered surfaces complete all as specified and directed.
M&L for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified & directed by Engr-in-Charge.
Taking down eaves gutters and rainwater pipes( any size or pattern) , including all fittings, heads, shoes, bends , swan necks, etc, removal to store (measured overall as fixed along the centre line over fittings and accessories).
S &F 160 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall complete all as specified and directed.
S &F 110 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall complete all as specified and directed.
S &F 75 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall complete all as specified and directed.
S&F for PVC (SWR) bends any radius 160mm bore complete all as specified and as directed
S&F for PVC (SWR) bends any radius 110mm bore complete all as specified and as directed
S&F for PVC (SWR) bends any radius 75mm bore complete all as specified and as directed
Cleaning the dust, vegetation, sand,dry leaves and other waste material at the rain water pipe of any size and any description, spouts, water outlets of the roofs etc as direcetd and dispose off debries at a distance of 50m and n.exc 1.5 Km including taking down and refixing of existing pipes including necessary fixing arrangements
M & L for PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in roof/chajja padding for maintaining roof/chajja slope complete all as specified and as directed
Dsimentling battens for tiles, shingles etc, of any size including tilting fillets complete all as specified and as directed by EIC.
M&L for Roof tiles, Mangalore pattern, interlocking at side joints, laid dry complete all as specified and as directed.
M&L for Ridge or hip tiles to suit Mangalore pattern of roofing tiles, bedded and jointed in lime mortar 1:3 or cement mortar 1:6 complete all as specified and as directed.
M&L for 1.50mm thick galvanised steel sheet as in valley gutter fixed with rivets with MS strip including clamp in both sides (MS clamp in MS flat iron patti or equivalent) or other suitable arrangement over MS bracket trapezoidal shape of required profile with desired slope etc complete all as specifided and as directed by Engr-in-Charge.
Dismantling of asbestos cement (Corrugated, semicorrugated etc) sheets including ridge in roof coverings.
Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings
S&F in repair pre painted galvalume aluminum zinc coated GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified & as directed by EIC.
S&F in repair pre-painted galvalume aluminum zinc coated GI based Plain steel sheet 0.50mm thick of any colour as in ridge having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
Dismantling wrought iron or mild steel works of any description of work etc.
M&L for framed work of Fe 410 W (Grade E-250) quality B as in gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and as directed.
M&L for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) Fe 410 W (Grade E-250) quality B including distance pieces, cleats etc.
M & L for errection & dismantling of MS tubler double scaffolding (H frame) upto height of 30m &with necessary brazing ,provision of necessary safety equipment to the skilled workers to carry out the work and covering with green cloths for carring out external face work of walls all as directed by Engineer -in-charge.
Dismantling of wall,wall panneling,partition and ceiling boards (fibre, pulp, insulation) or insulation boards, bonded wool, blanket slab incl aluminium grid frame work complete all as specified and as directed
M&L for POP false ceiling using 600X900x12 mm thick plaster of paris with gypsum binder sheet decorative type and necessary provision for concealed type light fittings, fixed on 22 gauge GI channel grid work, main joist of size 50x25 mm spaced at 750 mm centre to centre, secondary joist of size 75X20 mm fixed to main joists spaced at 900mm, suspended to roof members using 25x25x2 mm GI angles and fasteners @ 1.2 M C/C, including dismantling old un serviceable false ceiling, complete all as specified and directed. Including taking down old false ceiling and rubbish off the premises.
M&L for epoxy base joint paint such as on external surfaces of walls to fill the gap with and including resin and hardner in proportion as per manufacturers instructions complete all as specified and as directed Make : Pidilite / Fosroc / Chemistic/ Dr Fixit
Taking up and down 15 mm bore GI tubing and connection including cleaning for re-fixing or removing to store complete all as specified and directed.
_Ditto_ all as per Sl item No. 50 here in before but 20 mm bore complete all as specified and directed.
_Ditto_ all as per Sl item No. 50 here in before but 25 mm or 32 mm bore complete all as specified and directed.
S & F GI tubing medium grade galvanised with all fitting and fixed complete to walls and ceiling or laid in floors 15 mm bore of pipe complete all as specified and directed.
_Ditto_ all as per Sl item No.53 here in before but 20 mm bore of pipe
_Ditto_ all as per Sl item No. 53 here in before but 25 mm bore of pipe
Demolition of cement Concrete of any description and in any position not otherwise specifically provided for
M&L for PCC 1:3:6, type C2 of 75mm thick as in plinth protection etc complete
Removing excavated material exc. 5 Km but n exc. 25 Km and depositing where directed
jalandhara construction
sai construction
Shetty Construction Co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .