Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.3 LAccepted-AOC | L1 | Accepted-AOC Accepted due to lowest rate quoted | |
| 2 | L2₹27.7 L+₹1.4 L (5.25%)Rejected-Finance | L2 | Rejected-Finance Rejected due to highest rate quoted | |
| 3 | L3₹28.4 L+₹2.1 L (8.06%)Rejected-Finance H NO 90 VILLAGE REWLA KHANPUR PO NAJAFGARH NEW DELHI 110043 | NEW DELHI | WEST DELHI | DELHI | 110043 | L3 | Rejected-Finance Rejected due to highest rate quoted | |
| 4 | L4₹41.6 L+₹15.4 L (58.4%)Rejected-Finance A 47D RAM DUTT ENCLAVE UTTAM NAGAR NEW DELHI 110059 | WEST | DELHI | 110059 | L4 | Rejected-Finance Rejected due to highest rate quoted |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
23 May 2025, 6:00 pmClosed
GE (AF) GURGAON
GE (AF) GURGAON
PERIODICAL SERVICES / CAMOUFLAGE PAINTING TO CERTAIN BLDGS IN DOMESTIC/ TECHNICAL AREA OF AF STN ARJANGARH UNDER GE AF GURGAON
2025_MES_705452_1
GE/GUR-/NIT-08/2025-26
Open Tender
Civil Works
Item Rate
270 days
GE (AF) GURGAON
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) GURGAON
₹96,000
26 Jun 2025
25 Apr 2025
26 May 2025
25 Apr 2025
23 May 2025
9 May 2025
Amount
Taking down cement plaster on brick walls & concrete surfaces & the like including raking out joints, hacking for key, scrubbing down with water etc., any description, including removal of rubbish outside MoD land, complete all as specified.
M&L Rendering 15 mm thick on brick or concrete surfaces in cement mortar (1:4) finished fair and even without using extra cement, complete all as specified.
M&L for 10 mm thick cement plaster on fair faces of brick work or concrete surfaces in cement mortar 1:6 on walls including finishing surface even and smooth without using extra cement complete all as specified.
M&L for 5 mm thick cement plaster on fair faces of brick work or concrete surfaces in cement mortar 1:3 in ceiling including finishing surface even and smooth without using extra cement complete all as specified.
M&L for preparation of newly plastered or unplastered/undecorated surface of wall and applying two coats of oil bound distemper over one coat of primer complete all as specified.
M&L for preparation of newly plastered or unplastered/undecorated surface of ceiling and applying two coats of oil bound distemper over one coat of primer complete all as specified
Material and labour for preparation of newly plastered surfaces of walls and applying two coats of cement base paint to achieve uniform and smooth surface having no sign of brush marks complete all as specified and directed.
M&L Preparing of new surface of wall and applying two coats of exterior emulsion paint over a coat primer on walls complete all as specified and directed by Engineer-in-charge.
Preparation of old surfaces of walls including brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc.; rubbing down and stopping of surfaces using sand paper and applying one coat of cement base paint, complete all as specified and directed by the Engineer-in-Charge.
M&L preparation(complete removal of existing treatment) of old decorated external wall surface by mechanised sander of berger paints or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible and applying two coat of cement base paint over a coat of primeron walls complete all as specified and directed. Note : (a) Stage for Preparation of surfaces shall be got approved from Engg-In-charge before applying the finishes.
Preparation of old surfaces of walls including brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc.; rubbing down and stopping of surfaces using sand paper and applying one coat of oil bound distemper, complete all as specified and directed by the Engineer-in-Charge.
M&L for preparation of plastered or unplastered old decorated surfaces by complete removal of existing treatment by mechanised sander of berger paints or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible and filling of holes and cracks with with suitable material like cement or plaster of paris etc and thereafter applying two coat of oil bound distemper on walls. Note : (a) Stage for Preparation of surfaces shall be got approved from Engg-In-Charge before applying the finishes. (b) Material shall be procured from manufacturer.
All as per item No.12 here-in-before but on surfaces of ceiling.
M&L for preparation of old treated plastered or unplastered surfaces of ceiling including cornices by brooming down or steel wire brushing, scraping down, smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spot, filling cracks/holes with putty and applying one coat of distemper oil emulsion on ceiling complete .
M&L for providing 3mm thick wall care putty on wall before applying oil bound distemper and making the surface uniform all as specified. Note: OBD to be measured and paid saperately.
M&L for providing 3mm thick wall care putty on ceiling before applying oil bound distemper and making the surface uniform all as specified. Note: OBD to be measured and paid saperately.
M&L for preparation of old treated plastered or unplastered surfaces of walls/ceiling including cornices by brooming down or steel wire brushing, scraping down, smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spot, filling cracks/holes with putty and applying one coat of wheather proofing exterior acrylic emulsion paint on walls complete complete all as specified. Note : (a) Stage for Preparation of surfaces shall be got approved from Engg-In-Charge before applying the finishes. (b) Material shall be procured from manufacturer.
Material and labour for preparation of old painted surfaces of steel of any description and girth, not otherwise described and treated with one coat of synthetic enamel paint complete all as directed
Material and labour for preparation of old painted surfaces of wood and wood based of any description and girth, not otherwise described and treated with one coat of synthetic enamel paint complete all as directed.
Uprooting completely tree/plant upto 30 cm girth from wall or any part of building upto double storey buildings, making good the disturbed portion and filling holes in cement mortar 1:3 or PCC 1:2:4 to match with existing surfaces and removal of rubbish outside MOD land complete all aspecified and directed.
M&L for preparation(complete removal of existing treatment) of old decorated external wall/ceiling/rppf surface of existing treatment by scrapping with Trucare Wall Sander : L-01/H-01 (having mechanical vaccum mechanism) having RPM not less than 1500, sand pad of 80 grit having dia of 7"/9" to make the surface free from dust, loose paint etc or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible and applying Two coats of wheather proofing exterior acrylic emulsion paint ( Camouflage Pattern) over priming coat premium quality on wall/roof surface upto 4th storey buildings complete all as specified and directed. Note : (a) Stage for Preparation of surfaces shall be got approved from Engg-In-Charge before applying the finishes. (b) Material shall be procured from manufacturer and work shall be got executed through authorised applicator.
M&L for preparation of old treated plastered or unplastered surfaces of walls/ceiling/roofs including cornices by brooming down or steel wire brushing, scraping down, smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spot, filling cracks/holes with putty and applying one coat of wheather proofing exterior acrylic emulsion paint (Camouflage pattern) on walls complete . Note : (a) Stage for Preparation of surfaces shall be got approved from Engg-In-Charge before applying the finishes. (b) Material shall be procured from manufacturer and work shall be got executed through authorised applicator.
M&L for preparing old painted surfaces of steel and iron surfaces over 10 cm in width or girth by cleaning, sand papering, brushing with wire brushes, scrapping by steel scrappers etc and applying one coat of synthetic enamel paint(Camouflage pattern) to give an even and smooth surface having no sign of brush marks complete all as specified .
M&L for preparation(complete removal of existing treatment) of old decorated external wall/ceiling/rpf surface of existing treatment by scrapping with Trucare Wall Sander : L-01/H-01 (having mechanical vaccum mechanism) having RPM not less than 1500, sand pad of 80 grit having dia of 7"/9" to make the surface free from dust, loose paint etc or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible and applying Two coats of wheather proofing exterior acrylic emulsion paint over priming coat premium quality on wall/ceiling/roof surface upto 4th storey buildings complete all as specified and directed. Note : (a) Stage for Preparation of surfaces shall be got approved from Engg-In-Charge before applying the finishes. (b) Material shall be procured from manufacturer
Supply only intergral water proofing compound ISI Marked complete all as specified.
M&L Preparing of new surface of wall and applying two coats of exterior emulsion paint (Camouflage pattern)over a coat primer on walls complete all as specified and directed by Engineer-in-charge. complete all as specified and as directed by Engineer-in-Charge .
M&L for repairing of RCC projection chhajjas,mumty roof bottom, facia etc by necessary preparation. Scraping cutting, chiseling derusting and cleaning exposed reinforcement, surfaces of damaged, loose RCC with cement concrete (1:1.5:3) using 20mm graded stone aggt and reinforcement with welded mesh of weight 2 Kg per Sqm but n.exc 3 Kg per Sqm (if reqd) with or without facia and finished with cement and sand mortar (1:3) using coarse sand and work in patches area n.exc 10 Sqm and thickness of RCC member n.exc 120 mm incl necessary formwork and applying two coats of finishes to match with the existing surfaces at any height complete all as specified and as directed by Engr-in-Charge. (The rate quoted by the contractor shall included for welded mesh, scaffolding and necessary formwork upto triple storey bldg).
D P ENTERPRISES (BID ID -3303504)
Ish Engineers and Contractors (BID ID -3295489)
akhil enterprises (BID ID -3303354)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .