Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.0 LAccepted-AOC WZ 831 NANGAL RAYA PANKHA ROAD NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹58.5 L+₹16.6 L (39.5%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹62.0 L+₹20.1 L (48.0%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder |
| Sl No | Description | Qty | Unit | M/S Anil Enterprises L3 | Tushar engineers L1 | AS Engineering L2 |
|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5m depth for foundation etc or for shafts, wells cesspits manholes pier holes etc not exceeding 10 sqm on plan and in soft /loose soil etc complete all as specified and directed. | 203 | CUM | 75 ₹15,225 Lowest | 300 ₹60,900 | 250 ₹50,750 |
| 2.00 | Returning, filing in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil etc complete all as specified and directed | 116 | CUM | 25 ₹2,900 Lowest | 50 ₹5,800 | 85 ₹9,860 |
| 3.00 | Removal of excavated materials (soil) not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting points etc complete all as specified and directed. | 87 | CUM | 30 ₹2,610 Lowest | 50 ₹4,350 | 65 ₹5,655 |
| 4.00 | M&L for sand filling under floor or in foundations including gently punned as in cushioning to cable and for foundation in floor complete all as specified and directed.
Note:- Punned thickness of sand shall be measured and paid. | 61 | CUM | 350 ₹21,350 Lowest | 400 ₹24,400 | 1,300 ₹79,300 |
| 5.00 | M&L for brick protection cover to the under ground cable (with old size sub class 'B' bricks) with width equal to length of brick laid dry and flat abutting each other with gaps between adjacent brick not exceeding 10 mm all as specified and directed. | 6 | PER 1000 NOS | 6,700 ₹40,200 | 6,000 ₹36,000 Lowest | 6,500 ₹39,000 |
| 6.00 | M&L for boring of existing road / path upto 100mm for laying of GI pipe protection cover to the under ground cable and making good distrubed area / surface all as specified and directed. | 44 | RM | 300 ₹13,200 Lowest | 500 ₹22,000 | 850 ₹37,400 |
| 7.00 | S&F galvanised tube of 50 mm bore, light grade with all fitting laid in trenches complete all as specified and directed. | 22 | RM | 500 ₹11,000 | 400 ₹8,800 Lowest | 550 ₹12,100 |
| 8.00 | S&F galvanised tube of 80 mm bore, light grade with all fitting laid in trenches complete all as specified and directed. | 22 | RM | 800 ₹17,600 | 450 ₹9,900 Lowest | 1,150 ₹25,300 |
| 9.00 | M&L in repair for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35 sq. mm 3.5 core complete all as specified and directed.
Note - Excavation,earth work,sand,brick and protection pipe shall be measured and paid seperately. | 260 | RM | 275 ₹71,500 Lowest | 340 ₹88,400 | 369 ₹95,940 |
| 10.00 | M&L in repair for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 70 sq. mm 3.5 core complete all as specified and directed.
Note-Excavation,earth work,sand,brick and protection pipe shall be measured and paid seperately. | 255 | RM | 525 ₹1,33,875 | 465 ₹1,18,575 Lowest | 675 ₹1,72,125 |
Tender Value
₹42.3 L
EMD Value
₹84,600
Closing Date
16 Mar 2026, 6:00 pmClosed
GE (S) Jaipur
Garrison Engineer (South) Jaipur Military Engineer Services Kalyan Marg, Jaipur302006
SPECIAL REPAIR TO LT PANELS AND CONNECTED WORK AT ZONE-III AREA (MD ACCN) UNDER GE(S) JAIPUR AT MIL STN JAIPUR
2026_MES_753333_1
GE(S)/J-76P/2025-26 8451/E8
Open Tender
Civil Works
Item Rate
180 days
GE (S) Jaipur
Class D and Category b(i)
8 documents required · 8 mandatory
₹500
GE(S) Jaipur
₹84,600
Yes
25 Apr 2026
21 Feb 2026
23 Mar 2026
21 Feb 2026
16 Mar 2026
9 Mar 2026
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5m depth for foundation etc or for shafts, wells cesspits manholes pier holes etc not exceeding 10 sqm on plan and in soft /loose soil etc complete all as specified and directed.
Returning, filing in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil etc complete all as specified and directed
Removal of excavated materials (soil) not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting points etc complete all as specified and directed.
M&L for sand filling under floor or in foundations including gently punned as in cushioning to cable and for foundation in floor complete all as specified and directed. Note:- Punned thickness of sand shall be measured and paid.
M&L for brick protection cover to the under ground cable (with old size sub class 'B' bricks) with width equal to length of brick laid dry and flat abutting each other with gaps between adjacent brick not exceeding 10 mm all as specified and directed.
M&L for boring of existing road / path upto 100mm for laying of GI pipe protection cover to the under ground cable and making good distrubed area / surface all as specified and directed.
S&F galvanised tube of 50 mm bore, light grade with all fitting laid in trenches complete all as specified and directed.
S&F galvanised tube of 80 mm bore, light grade with all fitting laid in trenches complete all as specified and directed.
M&L in repair for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35 sq. mm 3.5 core complete all as specified and directed. Note - Excavation,earth work,sand,brick and protection pipe shall be measured and paid seperately.
M&L in repair for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 70 sq. mm 3.5 core complete all as specified and directed. Note-Excavation,earth work,sand,brick and protection pipe shall be measured and paid seperately.
M&L in repair for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 120 sq. mm 3.5 core complete all as specified and directed. Note :- Excavation, earth work, sand, brick and protection pipe shall be measured and paid seperately.
M&L in repair for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 185 sq. mm 3.5 core complete all as specified and directed. Note-Excavation,earth work,sand,brick and protection pipe shall be measured and paid seperately.
Disconnecting & taking out the existing unserviceable LT panel and S&F new LT Panel (415 Volts, 50 Hz , 3-phase, 4 wire supply) CPRI approved, factory assembled, outdoor type, weather and vermin proof (Protection Class IP-54) made out of 40mm x 40mm x 6mm angle iron frame and 3.15 mm(for external) and 2 mm (for internal) thick MS Sheet CRCA sheet with both side (front and back) hinged , double door opening for external, rubber lining, locking arrangement, painted externally and internally with two coats of synthetic enamel grey paint first quality over a coat of red oxide primer complete mounted on angle iron leg made of angle iron 40mm x 40mm x 5 mm and 60 cm high above GL and 15 cm embedded in ground with PCC 1:2:4 type B1 of block size 30x30x30 cm comprising of the following: (a) Copper Bus bar: - Bus bar chamber having 4 nos air insulated copper strip bus bars of rating not less than the 1.5 times the rated capacity of the incomer MCCB, as well as outgoings shall have copper TPN extension links (bus bar) of current carrying capacity not less than 1.5 times the rated capacity of individual MCCBs. (b) Incoming: - (i) MCCB 4 pole, LT 415 Volts, 50 Hz AC grade, 250 amps rating 4 pole, 36 KA, Adjustable thermal and adjustable magnetic release specially fixed for incoming supply with overload, short circuit and earth fault protection, adjustable type (Ics=100%Icu) - 01 No. Continue....(at Sl Item No. 18.01)
Disconnecting & taking out the existing unserviceable LT panel and S&F new LT Panel (415 Volts, 50 Hz , 3-phase, 4 wire supply) CPRI approved, factory assembled, outdoor type, weather and vermin proof (Protection Class IP-54) made out of 40mm x 40mm x 6mm angle iron frame and 3.15 mm(for external) and 2 mm (for internal) thick MS Sheet CRCA sheet with both side (front and back) hinged , double door opening for external, rubber lining, locking arrangement, painted externally and internally with two coats of synthetic enamel grey paint first quality over a coat of red oxide primer complete mounted on angle iron leg made of angle iron 40mm x 40mm x 5 mm and 60 cm high above GL and 15 cm embedded in ground with PCC 1:2:4 type B1 of block size 30x30x30 cm comprising of the following: (a) Copper Bus bar: - Bus bar chamber having 4 nos air insulated copper strip bus bars of rating not less than the 1.5 times the rated capacity of the incomer MCCB, as well as outgoings shall have copper TPN extension links (bus bar) of current carrying capacity not less than 1.5 times the rated capacity of individual MCCBs. (b) Incoming: - (i) MCCB 4 pole, LT 415 Volts, 50 Hz AC grade, 320 amps rating 4 pole, 36 KA, Adjustable thermal and adjustable magnetic release specially fixed for incoming supply with overload, short circuit and earth fault protection, adjustable type (Ics=100%Icu) - 01 No. Continue....(at Sl Item No. 19.01)
Disconnecting & taking out the existing unserviceable LT panel and S&F new LT Panel (415 Volts, 50 Hz , 3-phase, 4 wire supply) CPRI approved, factory assembled, outdoor type, weather and vermin proof (Protection Class IP-54) made out of 40mm x 40mm x 6mm angle iron frame and 3.15 mm(for external) and 2 mm (for internal) thick MS Sheet CRCA sheet with both side (front and back) hinged , double door opening for external, rubber lining, locking arrangement, painted externally and internally with two coats of synthetic enamel grey paint first quality over a coat of red oxide primer complete mounted on angle iron leg made of angle iron 40mm x 40mm x 5 mm and 60 cm high above GL and 15 cm embedded in ground with PCC 1:2:4 type B1 of block size 30x30x30 cm comprising of the following: (a) Copper Bus bar: - Bus bar chamber having 4 nos air insulated copper strip bus bars of rating not less than the 1.5 times the rated capacity of the incomer ACB, as well as outgoings shall have copper TPN extension links (bus bar) of current carrying capacity not less than 1.5 times the rated capacity of individual MCCBs. (b) Incoming: - (i) ACB (Air Circuit Breaker) 4 Pole, 415 V, 50 KA, Manual Drawout type with microprocessor release of capacity 630 Amps and including extension terminals and Ics = 100% Icu Continue....(at Sl Item No. 20.01)
Disconnecting & taking out the existing unserviceable LT panel and S&F new LT Panel (415 Volts, 50 Hz , 3-phase, 4 wire supply) CPRI approved, factory assembled, outdoor type, weather and vermin proof (Protection Class IP-54) made out of 40mm x 40mm x 6mm angle iron frame and 3.15 mm(for external) and 2 mm (for internal) thick MS Sheet CRCA sheet with both side (front and back) hinged , double door opening for external, rubber lining, locking arrangement, painted externally and internally with two coats of synthetic enamel grey paint first quality over a coat of red oxide primer complete mounted on angle iron leg made of angle iron 40mm x 40mm x 5 mm and 60 cm high above GL and 15 cm embedded in ground with PCC 1:2:4 type B1 of block size 30x30x30 cm comprising of the following: (a) Copper Bus bar: - Bus bar chamber having 4 nos air insulated copper strip bus bars of rating not less than the 1.5 times the rated capacity of the incomer MCCB, as well as outgoings shall have copper TPN extension links (bus bar) of current carrying capacity not less than 1.5 times the rated capacity of individual MCCBs. (b) Incoming: - (i) MCCB 4 pole, LT 415 Volts, 50 Hz AC grade, 320 amps rating 4 pole, 36 KA, Adjustable thermal and adjustable magnetic release specially fixed for incoming supply with overload, short circuit and earth fault protection, adjustable type (Ics=100%Icu) - 01 No. Continue....(at Sl Item No. 21.01)
M&L in repair for earthing with galvanised iron earth plate electrode 600mm x 600 mm & 6 mm thick buried directly in ground vertically (earth pit not less than 2.25 metre deep below normal GL) with top of earth plate not less than 1.5 metre below Ground level, connected to GI strip 25x4 mm (up to 7.5 metre) by means of GI nuts, bolts & washers , earth strip protected with & including 40 mm dia light grade GI pipe (up to 7.5 metre) all as shown in electrical plate No 3 of MES Schedule Part I, with & including PCC 1:3:6 type C1 for pit with cover of 50 mm thick RCC 1:1.5:3 type A1 reinforced with welded steel wire fabric not less than 4 Kg per Sqm, watering arrangements with 20 mm GI medium grade pipe , GI funnel with GI mesh, filling with common salt & charcoal in alternate layers, necessary excavation and earth works in any type of soil, including test point, testing & commissioning, complete all as specified and directed. Note :- 1. The insulation procedure shall be followed as per instruction of the earth electrode manufacturer. 2. GI pipe of suitable size for protection against mechanical damage of main earth strip from earth electrode to test point up to 7.5 metre to be provided. The cost for the same shall be deemed to be included in the quoted rate. GI strip & GI protection pipe beyond 7.5 metre shall be measured & paid separately. 3. If desired earth resistance is not obtained during testing ,the earthing shall be re-done with out any extra cost.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.59 MB
8451Tender.pdf
Tender Documents • 1.04 MB
BOQ_843781.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .