Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.4 CrAccepted-AOC B 437 438 ROAD NO 18A KALADWAS BHAMASHAH INDUSTRIAL AREA UDAIPUR RAJASTHAN 313001 | UDAIPUR | RAJASTHAN | 313001 | ₹2.4 Cr Quoted ₹2.5 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹3.2 Cr+₹78.5 L (31.9%)Rejected-AOC | ₹3.2 Cr+₹78.5 L (31.9%) | L2 | Rejected-AOC L2 |
Tender Value
₹2 Cr
EMD Value
₹2 L
Closing Date
21 Dec 2020, 3:00 pmClosed
MD, RISL
1st floor, yojana Bhawan, Tilak Marg, C scheme jaipur
RFP Document for Interior Works of State Emergency Operation Center (SEOC) at Jaipur
2020_RISL_207279_1
F3.3 (280)/RISL/Pur/2019-20/12227
Open Tender
Civil Works
Item Rate
120 days
as per RFP
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,000
MD, RISL
₹2 L
Yes
22 Jul 2022
10 Dec 2020
21 Dec 2020
10 Dec 2020
21 Dec 2020
10 Dec 2020
Amount
Control Room Interior BOQ Schedule
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge.
In cement mortar.
Brick masonry with F.P.S. bricks of class designation 75 in foundation and plinth with bricks
Cement mortar 1 : 6 (1 cement : 6 coarse sand)
Plaster on new surface on wall in cement sand mortar 1:3 including racking of joints etc. complete fine finish :
20mm thick
SITC of Printed Metal Paneling :- The Panelling shall have the same specifications as that of Modular Rigid PVC Metal Panelling. However, in addition to it the surface tile shall be digitally printed. Graphics shall be approved by the Customer.UV digital printing on modular metal Panelling. For more details please refer Technical specification enclosed in rfp
SITC of Acoustic Metal Partition:- Partition with factory made removable type self inter lockable metal panels of Preformed textured RIGID PVC coated GI sheet panels. The metal panels fixed on structure made of 1.6 mm thick MS channels bent over automatic punching to fix metal panel and bending CNC. and their properties shall be as follows :- 1) Resistance to extremes of weather exposure and temperature. 2) Very low coefficient of expansion. 3) Can be cleaned using detergents. 4) Copy of Test certification for ASTM E84 (from UL/Intertek) for the surface burning characteristics of wall Panelling tiles to be submitted during drawing approval stage before commencement of job. This is mandatory requirement from Fire safety point of view. 5) Wall Panelling shall be Seismic Zone 5 Tested & certified from approved government agency, relevant certificate to be submitted during drawing approval stage before commencement of job. 6) The Wall Paneling system must be RoHS (Intertek/UL) certified, valid certificate to be submitted during drawing approval stage before commencement of job 7) Minimum 40% of the tiles shall have perforations to achieve NRC of 0.6 Sound Absorption Coefficient by diffuse field method; IS: 8225-1987 “Measurement of Sound Absorption Coefficient in Reverberation Room” (Equivalent to ISO: 354- 1985 and ASTM 423-90). Test report from reputed agency to be submitted during drawing approval stage before commencement of job. For more details please refer Technical specification enclosed in rfp
SITC of Acoustic Metal Paneling :- Paneling with factory made removable type self inter lockable metal panels of Preformed textured RIGID PVC coated GI sheet panels. The metal panels fixed on structure made of 1.6 mm thick MS channels bent over automatic punching to fix metal panel and bending CNC. and their properties shall be as follows :- 1) Resistance to extremes of weather exposure and temperature. 2) Very low coefficient of expansion. 3) Can be cleaned using detergents. 4) Copy of Test certification for ASTM E84 (from UL/Intertek) for the surface burning characteristics of wall Panelling tiles. This is mandatory requirement from Fire safety point of view. Certificate to be submitted during drawing approval stage before commencement of job. 5) The wall panelling/ partition system must be RoHS certified (from UL/Intertek) to ensure restriction of hazardous substance in any of the materials. Certificate to be submitted during drawing approval stage before commencement of job. 6) Minimum 40% of the tiles shall have perforations to achieve NRC of 0.6 Sound Absorption Coefficient by diffuse field method; IS: 8225-1987 “Measurement of Sound Absorption Coefficient in Reverberation Room” (Equivalent to ISO: 354- 1985 and ASTM 423-90). Test report from reputed agency to be submitted during drawing approval stage before commencement of job. 7) Wall Panelling shall be Seismic Zone 5 Tested & certified from approved government agency. Certificate to be submitted during drawing approval stage before commencement of job. 8) UL Certificate on Load bearing capacity of paneling - Paneling structure shall have load carrying capacity of 300 Kg to hold any display unit on clamp having minimum length of 750mm. UL Certificate to be submitted during drawing approval stage before commencement of job. For more details please refer Technical specification enclosed in rfp
SITC of Metal Panel made Straight Rafters Metal rafter made out of 200 X 75mm MS C sections covered by factory made metal panels of Preformed textured PVC coated GI sheet panels. Copy of Test certification for ASTM E84 (from UL/Intertek) for the surface burning characteristics of wall Panelling tiles. This is mandatory requirement from Fire safety point of view.
SITC of Glass Partition Material:- (12 mm thick toughened glass) Including full glass partitions of minimum 12 mm thick clear toughened glass, structural support system for top and bottom including holding system from RCC slab above false ceiling, including runner hung anchor fastener to fix it. Rubber interlinear & gaskets to fix bottom into SS "U" channel in floor. silicon sealant to filled gap. For more details please refer Technical specification enclosed in rfp
SITC of 12mm thick frameless tempered clear glass doors :- With door spring and locking arrangements and both way handle and patch fittings. Specifications : Tempered glass is formed by heating glass to the softening point in a horizontal tempering stove, and then quickly cooling it. Properties: 1) Safety (tempered): when broken, it spits into tiny harmless pieces 2) Strong intensity: heat-strengthened glass is approximately twice as strong as annealed glass of the same thickness, and tempered glass is about 4 times 3) Outstanding performance in resisting thermal stress and wind-load 4) Tempered glass cannot be cut, drill hole and other further processed. For more details please refer Technical specification enclosed in rfp
SITC of Designer Metal doors with frame (with glass vision panel) covered with Preformed textured RIGID PVC coated GI sheet:- With door closer/spring and locking arrangements and both way handle. Structure made of 1.6 mm thick MS channels bended over automatic punching and bending CNC. For more details please refer Technical specification enclosed in rfp
SITC of Designer Acoustic Metal False ceiling with linear planks :- 100% Modular factory made Powder coated Dual layer hook ceiling with combination of acrylic panels for installation of linear lights, designed to enhance visual feel and provision for easy installation and maintenance of integrated lighting. The perforated (140-150 mm Wide) and non-perforated (275-300mm Wide) ceiling panels of various lengths (as per the site requirement) shall be alternatively connected to form designer ceiling. Machine profiled section 125-175mm wide and 60-80mm deep having provision for fixing acrylic sheet shall run across the length at the room. Tiles shall be processed on high precision CNC & laser Machines to achieve perfect accuracy. Structure shall be made from heavy duty modular steel frame (minimum sheet thickness 0.8mm) with combination of Master section and series of main runners spaced at 1200 mm (center to center) securely fixed to the slab by the means of anchor fastener & 8 mm GI rod (max length 1200mm) fully threaded with Hex nut for precise level adjustment. Light fitting can be defined as per the LUX requirement. It shall have Laser cut circular hole for light fixing as per defined lux requirement and approved layout. Non-perforated tile slots to be punched to accommodate AC grills. 1) Metal ceiling shall be Seismic Zone 5 Tested & certified from approved government agency. Certificate to be submitted during drawing approval stage before commencement of job. 2) ASTM E84 certificate (From UL/intertek) for Ceiling tiles to ensure that the material does not provoke fire and does not generate smoke. Certificate to be submitted during drawing approval stage before commencement of job. 3) The Ceiling must be RoHS certified (from UL/Intertek) to ensure restriction of hazardous substance in any of the materials. Certificate to be submitted during drawing approval stage before commencement of job. 4) The Ceiling shall have UL Certified Integrated inbuilt channel for quick installation &replaceability of continuous linear light and shall permit quick and easy replacement of cove light without using any tools. Replacement to be carried out within 120 Seconds per meter. Certificate to be submitted during drawing approval stage before commencement of job.
SITC of Grid type 2' X 2' Ceiling:- Modular perforated metal false ceiling. Tile dimension shall be 2' X 2'. with durable regular edging and having following properties:- i) NRC (Noise Reduction Co-efficient) ii) Light reflectance. iii) Fire performance. iv) Humidity Resistance. v) Hot dipped galvanized steel. vi) Baked Polyester Paint surface. For more details please refer Technical specification enclosed in rfp
SITC of Material for false flooring:- Supply of fiber reinforced Calcium Sulphate panels having edges finished with PVC edge band and top surface should be finished with durable & environment friendly acoustic Forbo thick Marmoleum pasted with special glue. Tile Size should be 600mm X 600mm with ESRG system suitable for finish floor height up to 150mm. - The Panel shall have:- - Density of 1650KgM3. - DIN 4102 class A1 for Heat Resistance & - BS 476 for fire resistance. - Core material thickness should be 30mm. For more details please refer Technical specification enclosed in rfp
SITC of Optional CORPORATE LOGO Approx. Dimensions: 1200mm(W) X 900mm(H) For more details please refer Technical specification enclosed in rfp
SITC of Signage on Doors Entry and Exit Specification: Signage's are made up of laser cut Anti-Corrosive high grade AISI 316 Stainless Steel of 2mm thick sheet with laser cut method for impression and with satin finish. Approx. Dimensions: 300 mm X 170 mm X 2 mm For more details please refer Technical specification enclosed in rfp
SITC of Designer privacy film for glass Partition and glass Door
Furniture Schedule
Supply & Installation of New Modular Control Desk for provision of 03 monitors. 1. Table Top:- The material of the working surface should be minimum 25 mm thick MDF with High Pressure ANSI/NEMA LD3 certified scratch-resistant laminate. 2. Control Desk shall be Seismic Zone 5 tested and certified with monitor mounted on monitor arms of the console. Seismic test report of bare control desk shall be deemed unacceptable. Report need to be submitted during drawing approval before commencement of job. 3. The structure shall be rigid enough to withstand BIFMA X5.5: 2014 (Latest Edition). OEM must be BIFMA X5.5: 2014 certificate for at-least three years prior to release date of tender. The structure shall allow easy assembly of Hinged Shutters, Slat wall, Gland Plate, Monitor arms in extremely rigid manner. Certificate to be submitted during drawing approval before commencement of job. 4. Front Edge:- UL Certified design of high density Poly Urethane Foam moulded on industrial grade aluminium core to form 50mm deep tapered edge to be installed on worktop. The Edge shall be mechanically replaceable within 30 minutes in case of damage or wear without opening or removing the worktop. The shore hardness of 50mm deep front edge shall be between 60 to 90. Certificate to be submitted during drawing approval before commencement of job. 5. Slat Wall shall be made of approx. 2mm thick Extruded Aluminium (HE9WP aluminium alloy) and designed in such a way that no joints or gaps are visible in the entire width of the console. The entire console must be UL Listed. Certificate to be submitted during drawing approval before commencement of job. 6. Monitor Arm: - UL certified monitor arm assembly shall have auto lock, push & remove feature for quick release of VESA mounts and modular arm extensions for ease in maintenance and fixing of monitor by one technician within 30 seconds without using any tools. Certificate to be submitted during drawing approval before commencement of job. 7. Shutters & Side Legs: - Front, back shutters shall be of 18 mm Laminated MDF Board with premium finish. Side leg shall be of 25mm of the same finish. Hinges shall have life time warranty. Entire console must be Greenguard Gold certified. Certificate to be submitted during drawing approval before commencement of job.
Supply & Installation of Meeting Table 1. Table Top: made up of 25mm thick Prelaminated Particle Board with 2mm thick PVC edge banding tape. 2. Leg: made up of MS Powder Coated Finish.(75x25mm) 3. Understructure Pipe: made up of MS Powder Coated Finish. (40X40mm) 4. Cable Riser & Cable Tray: made up of MS Powder Coated Finish. 5. Accessories: Flap As per the detail sizes given below for Item 90.1, 90.2. For more details please refer Technical specification enclosed in rfp
Supply & Installation of Meeting Table (10 Person) Approx. Dimensions: 5400(W) X 1200(D) X 750(H)
Supply & Installation of Low Height Credenza 1. Structure: made up of 18mm thick Prelaminated Particle Board with 2mm thick PVC edge banding tape. Approx. Dimensions: 1200(W) X 450(D) X 750(H) For more details please refer Technical specification enclosed in rfp
Supply & Installation of Office Chair: 1. Medium Back Chair 2. PP Arm 3. Nylon Base 4. Gas Lift 5. Seat Back Net Tapestry For more details please refer Technical specification enclosed in rfp
Dismantling doors, windows and clearstory windows steel or wood shutter including chowkhats and holdfasts etc. complete and stacking within 50 meters lead:
Of area 3 square meter and below.
Brick work with mechanised autoclaved flyash lime bricks conforming to IS: 12894 :2002 of class designation 100 in superstructure above plinth level upto floor V level in. (Cement mortar 1:6 ( 1 cement : 6 coarse snad). The rate is inclusive of work up to G+4 Level including scaffolding.
Add extra for facing as per design and detailed specifications including additional cost of stones Ashlar rough tooled facing.
Dismantling tile work 10mm to 25mm thickness in floors and wall laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 meter lead:
Half Brick work with mechanised autoclaved flyash lime bricks conforming to IS: 12894 :2002 of class designation 100 in superstructure above plinth level upto floor V level in. ( Cement mortar 1:4 ( 1 cement : 4 coarse snad). The rate is inclusive of work up to G+4 Level including scaffolding.
Add extra providing and placing in position 2 Nos. , 6mm Ø M.S. bar at every third course of half brick masonry.
Plaster on new surface on walls in cement sand mortar 1:4 including racking of joints etc. complete fine finish :12 mm thk. The rate is inclusive of work up to G+4 Level including scaffolding.
Providing and laying water proofing treatment to vertical and horizontal surface of depressed portions of W.C., kitchen and the like consisting of: 1) 1st course of applying cement slurry @ 4.4 kg/sum mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizental surface.2) 2nd course of 20mm cement plaster 1:3 ( 1 cement : 3 coarse sand) mixed with water. proofing compound in recommended proportion including rounding off junction of vertical and horizental surface.3) 3rd course of applying blown or residual bituman applied hot at 1.7 kg per sqm. of area. 4) 4th course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100mm wide and pasted to each other with bitumen @1.7 kg/sqm.
Filling of sunk portion of roof with earthen pots of required height including filling voids with 1:3:6 light concrete, using brick bats complete levelling and dressing the surface by 50mm thick cement concrete 1:2:4 as per specification.
Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, shelves, sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:2 ( 1cement : 2 coarse sand) jointing with white cement mortar 1:2 (1 white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete. Up to 1500 Cm2 tiles ( Black)
Extra for providing edge moulding to 15-18mm thick marble/ Granite stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge. Granite Work
Extra for providing opening of equired size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/ stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edges etc. complete.
Providing Marble partitions. One partition will consist of two 16 mm marble stones . The marble should be prepolished.
Hydraulic door closer bottle type M.S. body with necessary accessories and screws complete
Providing and fixing pessed steel door frames confirming to IS 4351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface including filling with CC 1:2:4 (M 15 grade)complete as directed by Engineer-in- charge:Profile E
Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS: 13753 & IS :15622 of size 300mm x 450mm in wall, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush painting in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement plaster on walls and pillar). For toilet wall.
Providing and fixing 1st quality MAT finished ceremic tile size 300x300 mm confirming to IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush painting in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4)
Providing and applying white cement based putty over plastered surface to prepare the surface even and smooth complete. The rate is inclusive of work up to G+4 Level including scaffolding.
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding : Two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect. The rate is inclusive of work up to G+4 Level including scaffolding.
Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesin in glue both sides with approved steel fittings complete as per annexure '1' :35 mm thick . Decorative teak veneer one side.
Extra for providing external lipping with 2nd class teak wood battens 6 mm ninimum depth on all edges of shutters (over all area of door shutter to be measured )
Providing and fixing GYPSUM ceiling in STRAIGHT OR CURVED shape with INDIA GYPSUM ceiling sections with MAINS GI frame at 1200 c/c with cross members to be fixed at 450 c/c. The mains to be fixed on wall with PERIMETER members. The ceiling sections to behanged from ceiling with hangers at every 1200 c/c 12.5mm GYPSUM board to be screw fixed on the frame. The tapered edges of the board to be filled with jointing compound and covered with paper tape. The ceiling is finished with TOP coat as approved by INDIA GYPSUM. The item includes making all necessary steps, coves, openings etc. complete including two or more coats of plastic emulsion paint..
CARRIAGE OF MATERIALS: Building Rubbish Stone metal (Grit and ballast etc.) For 20 Km.
PLUMBING ESTIMATE
P & F European type white glazed vitreous china Ist quality W.C. pan (IS:2556 Mark) with P or S trap including cutting and making good the wall and floor.
Providing & fixing water closet seat covers with brass hinges complete:
Solid PVC (ISI marked) grade-I White for EWC.
P & F C.P. lugs for toilet seat cover.
P & F lst quality WVC Urinal (IS:2556 mark) with 25mm dia G.I. waste pipe, dome waste couplings, concealed iron brackets or screws etc complete.
Flat Back (large) or half stall size: 610 X 400 X 80 mm.
P & F W.V.C. Urinal Partition Plate of approved standard make of size 630 x 315 mm including making good the wall.
Providing & fixing Low Level Flushing Cistern of 10 litres capacity (IS:2556 mark) of approved make with complete fittings, C.I. brackets duly painted, brass ball cock with ball, (IS:1703 mark) complete including cutting and making good the wall :
PVC with PVC bend as per IS : 7231.
P & F C.P. brass Urinal Flush Pipe set complete with flanged brackets of approved make.
For 1 Urinal
Providing & fixing WVC Wash Basin (1st quality, IS: 2556 mark) of approved make with C.I. Brackets duly painted, 1.No.15mm C.P. Pillar cock (I.S.: 8934 mark) & 32mm C.P. brass waste coupling of approved make, 25mm G.I. waste pipe complete including cutting and making good the wall :
Size 510 mm x 400 mm
P & F Bevelled edge Mirror of special glass of approved make complete with 6 mm thick asbestos cement sheet ground fixed to wooden screws & washers.
Size 600 x 450mm x 4 mm thick
P&F towel rail or ring of approved quality /make:
C.P. brass Towel Rail elbow type with concealed screws size 600 mm (Heavy duty).
Providing & Fixing Grating of approved quality/make:
Stainless Steel Sheet Square 150 x 150 x 8mm. (Anti Cockroach)
P & F Toilet Paper Holder with rod of approved quality/make:
C.P. brass heavy & Superior quality.
P&F Soap dish or tray of approved quality/ make.
C.P. brass heavy and superior quality.
P&F extension pipe for bib cocks of approved quality/ make:
C.P. brass of Heavy & Superior quality 150 x15mm
P & F Jet spray for water closet with C.P. Copper tube flange of approved make.
Providing and fiixng C.P. flange for 15mm diatap.s
Concealed pipe in wall including painting with anticorrosive bitumen paint
15 mm dia nominal bore
20 mm dia nominal bore
P & F G.I. Pipes (External work) with G.I. fittings (IS:1239 Mark) including trenching & refilling earth etc.
32mm dia nominal bore ' B class '
40mm dia nominal bore ' B class '
Making connection of G.I. distribution branch with G.I. main including all fitting.
Beyond 25mm &upto 100mm dia
P & F Ball Cock (IS :1703 Mark) with Rod &P.V.C. Ball complete :
Brass wt.2000 gm 50mm.
P & F Full-way Valve (IS:778 Mark) or wheel valve of approved make :(Gun metal)
Gun Matel 25mm nominal bore.
P & F PVC Storage Tank ISI Marked (IS : 12701) indicating the BIS license No), of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design:
Hoisting Charges for each floor :
For items 2.26.1 to 2.26.4
Providing and fixing Superior quality CP Brass fittings of approved make as per direction of Engineer-in-charge
Two way Bib Cock 15 mm nominal size
Angular stop cock with long thread 15 mm nominal size
Concealed stop cock 15 mm nominal size
P & F 15 mm. Dia Connection pipe of approved quality/make:
C.P. Brass Pipe with CP Brass nuts upto length 450 mm.
P&F rigid PVC Pipe (IS:4985 mark) class II(4 Kg. /Cm.) approved quality /make including joining the pipe with solvent cement rubber ring and lubricant
63mm dia
Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes Type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make
75 mm dia
110 mm dia
Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make
Coupler
75mm dia
110mm dia
Bend 87.5 Dg.
75mm dia
110mm dia
Bend 45 Dg.
75mm dia
110mm dia
Pipe Clip
110mm dia
W.C. Connector
110mm dia
Single Tee
75mm dia
110mm dia
Nahni Trap with Jali 4”
110mm dia
Nahni Trap with Jali 3”
110mm dia
Vent Cowel
110mm dia
Construction of manhole in all type of soil inner size 90 X 60 Cm. 300 mm thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5 10 in foundation, 20 mm thick inside plaster in CM 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring, making channels, 80mm thick stone slab covering with 40mm thick M-15 grade C.C. flooring, Cement cover with frame of 450mm dia, earthwork etc. complete as per design including disposal of surplus earth within 50 mtr. lead.
Depth up to 0.5 M
Add extra over item 3.21.1 for every additional 0.10m depth above 0.5 m depth.
Fixing of fresh air fan/exhaust fan up to size of 300 mm on ply/ poly board of 6.0 mm in existing window frame including cutting of hole in ply. Nut bolts etc. as required.
Lighting
Supply, Installation, Testing and Commisioning of LED Based Recessed 2' x 2' Fixture with a maximum system wattage fo 39 Watts and a minimum system lumen putput of 2800 lumens, The luminaire shall meetIP20 rating with THD<15% and Power Factor >0.90, Operating Voltage Range of 140 - 270 V. LM 79 and LM 80 reports to be submitted from a NABL accredited in-house Lab to verify the above perimeters.
P & F of IP20 LED Recessed / Surface Mounted, Round / Sqaure Non-Dimmable Downlight with die-cast aluminum housing & Heat Sink for heat dissipation, high purity reflector with external BIS certified 2.5 KV surge protected driver having efficiency > 85% and in compliance to IEC standards. System Lumen efficacy of ≥ 100 lm / watt and life time of minimum 35000 Burning Hours with 70% of intial Lumen maintaned, CCT 3000°K / 4000°K / 6000°K , maximum power consumption should not more than the specified rating and Fixture shall be of CE complianed.
Recessed Mounting: LED Downlight 18/20W
Providing and Laying following sizes (dia.) of ISI marked medium duty PVC conduit along with accessories in surface / recessed using saddles, clamps, fastener as required including cutting the wall, covering conduit and making good the same as required Group 1 (For ELV works)
Wiring of light point / fan point / exhaust fan point / call bell point with 1.5 sq. mm FR insulated unsheathed flexible copper conductor 1.1kV grade and 1.5 sq.mm FR insulated unsheathed flexible earth copper conductor 1.1 kV grade (IS:694) including the cost of ISI marked Medium duty PVC conduit in surface / recessed & it's accessories, 18 swgM.S.modular box, 6 A modular type switch with modular grid plate & cover plate, zinc plated / brass screws, cup washers, bushes check nuts, making connections, testing etc. as per specification, drawing & preferred make.
One point controlled by one no 6 A switch
Group of two or more points controlled by one no 6 A switch
Wiring of 3 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) of approved make in surface / recessed ISI marked medium duty PVC conduit & it's accessories, Hot Dipped Galvanized M.S Modular box of 20 SWG with earth terminal, 6 A modular switch, 6 A modular socket, Modular plate with grid plate, screws, making connections, testing etc. as required (Gr. 1)
On board
Short point (up to 3 mtr.)
Medium point (up to 6 mtr.)
Long point (up to 10 mtr.)
Copper Conductor Wiring
Supply and Drawing of FR PVC insulated & unsheathed flexible copper conductor ISI marked (IS:694) of 1.1 kV grade and approved make in existing surface or recessed conduit/casing capping including making connections etc. as required (Gr 1.)
3x 1.5 sq.mm
2 x 2.5 sq. mm. + 1x1.5sqmm
2 x 4.0 sq. mm. + 1 x 2.5 sq. mm.
4 x 10.0 sq.mm
Distribution Board & it's Accessories
SITC of 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C/ D tripping characteristic) ISI marked IS 8828(1996)]/ conforming to IEC 60898 in existing board/sheets including making connections, testing etc. as required.
Single pole MCB
6 A to 32 A rating
Four pole MCB
40 A 63 A rating
SITC of 240/415 V Residual current circuit breaker conforming to IS:12640:1988/ IEC 61008 on existing board/sheet including making connections, testing etc. as required
Two pole 30 mA sensitivity
40 A rating
Four pole 100/300 mA sensitivity
40 A rating
63 A rating
SITC of Recessed/ Surface mounting heavy duty horizontal type sheet steel Distribution board phophatised/ powder painted complete with suitable rating insulated copper bus bar, shorting link, neutral link, earth link and din bar,masking sheet, conforming to IS13032 & IS8623 including making internal DB terminations with copper lugs, testing etc. as required.
Double Door (Single Phase)
Double Door (Three Phase)
P&F metal clad industrial plug top & socket unit with pin and sleeve type contact on porcelain/ bakelite base in sheet steel enclosure (without MCB) including making connections, testing etc.as required
Three / Four pole (Five pin): 30A-32A
SITC of recessed/ surface mounting heavy duty Vertical type 16 SWG sheet steel Distribution board with provision of incomer suitable for MCCB and SP / TP MCB as outgoing, phophatised, powder painted complete with insulated suitable rating copper bus bar, neutral link, earth link and din bar, masking sheet & conforming to IS13032 & IS8623 including making internal DB terminations with copper lugs, testing etc. as required
Double Door with Provision of Incomer MCCB
SITC of quick make and quick break 4 POLE current limiting MCCB having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings and conforming to IS 60947-2 / IEC 60947-2 with front face and centralised adjustable, line load interchangeability, having positive isolation capability, provision for UVR , shunt trip, earth fault trip, push (test) to trip, including making connections with lugs & spreaders, etc. as required.
With Thermal Magnetic release
up to 125 Amp, 25 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu
Wiring Accessories
Providing and Fixing of following modular accessories made out of unbreakable and fire retardant poly carbonate with silver contacts including making connections testing etc. as required
6 A One Way Switch
6 A Bell Push
6 A 3 Pin Shuttered Socket
16 A 6 Pin Shuttered Socket
RJ-45 Computer Jack with Shutter
T.V. Coaxial Socket
5 Step Fan Regulator 2 Module
Blanking Plate
16 A One Way Switch
SITC of following size mounting grid plates with cover plates
1/2 Module
3 Module
6 Module
8 Module
10/ 12 Module
SITC of following size hot dip galvanized M.S. box of 20 SWG with earthing terminal in recess/ surface suitable for modular accessories as required.
1-2 Module
3 Module
6 Module
8 Module
10/ 12 Module
LT Cable
Supply and Drawing of P.V.C. / XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with Copper conductor of IS:1554 P-I / IS:7098 P - I of Group 1 of approved make in ground as per IS:1255 including excavation of 30 cm x 75 cm size trench, 25 cm thick under layer of sand, IInd class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. UNARMD CABLES
Cable Termin Accessories
SITC of end termination with heavy Copper lugs (Pin / Ring type) duly crimped with crimping tool, PVC tape etc of following size.
SITC of following sizes of powder coated perforated M.S. cable trays including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with M.S. suspenders, fastners, supports etc. as required.
150mm x 50mm x 1.6mm
450mm x 50mm x 2.0mm
Earhting
SITC of Plate Earthing as per IS:3043 with copper Earth plate of size 300mm x 300mm x 3.0mm by embodying 3 to 4 mtr. below the ground level with 25 mm dia. G.I. 'B' class watering Pipe including all accessories like nut, bolts, reducer, nipple ,wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size 300 mm x 300 mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required.
SITC of following size earth wire/strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. as required.
25mm x 5mm Copper Strip
SITC of following size' B ' class G.I. Pipe confirming to IS : 1239 P-1 (1990) with accessories for laying earth conductor/ strip/ cable in ground/ surface/ recess as required
40 mm dia
Local Area Networking
SITC of 4 pair, 24 AWG UTP Cat 6 Cable as per latest ammendments of TIA /EIA 568 B.2-1 Specifications in existing MS/PVC Conduits including making connections to Information outlets and Patch Panels with ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing required
Supply and Installation of Information outlets made of high impact plastic body ABS FR Grade with spring loaded collapsible shutters in jack Recess, suitable for Cat 6 application complying to latest ammendments EIA/ TIA 568 B.2-1 Specifications in existing modular /MS Boxes along with necessory connections as required
Supply , Installation, Testing and Comissioning of Rack mounted 19", Cat 6 UTP,1.5-1.6 MM CRS chasis , powder coated Modular Patch Panels with collapsible shutters on jacks to support latest ammendments of TIA / EIA Cat 6 Specifications in Existing Communication Rack along with necessary connections of Cat 6 UTP Cables, With Rear Cable management trays and clamps.
24 Ports
Supply , Installation and Testing of 4 pair, 100 Ohm, 24 AWG, Cat 6 UTP, flexible, Double ended Patch Cords along with 2 No of RJ 45 connectors with strain relief transparent boots as per TIA /EIA 568 B.2-1 Specifications.
1 Mtr / 3 ft
3 Mtr / 10 ft
Supply, Installation, Testing and Comissioning of Wall mounted Communication rack with Glass Doors, Handles, Lock , Top and Bottom Cable entries, Supports for mounting rack on wall, Cable Managers, One Fan, Equipment Mounting Hardware, Power Supply Box for supplying power to switches, fans etc along with earth continuity kit, MCB, Indicator, Moulded Power Supply Cable
12 U (44 mm) wall mounted
SITC of Managed Layer-2 Intelligent Ethernet Switch providing 24 x 10/100/1000 Fast Ethernet ports and with min 4 SFP Giga Ports (provision for Fiber Giga connectivity) with provision of minimum Stacking of 06 Switches with related LAN Base Software
Access Control System
Supplying, Installing, Testing & Commissioning of the access control system consisting of the following:
Supply, installation, testing & commissioning of proximity card readers as per specification suitable for mounting on metal surface/ metal frames or wooden frames wall or as required based on site conditions including all accessories
Supply, installation, testing and commissioning of Smart cards as per specification.
Supply, installation, testing and commissioning of Push Button for Exit
Break Glass Unit for Access Doors
BIO METRIC Finger Reader as per specification
Supply, installation, testing and commissioning of IP based Door Controller for Controlling the above card readers as per specification mentioned including all accessories. Max. 4 Reader combition (Tenderer to mention quantity of controllers based on their system.) System should have capability to expand up to additional 100 doors in future.
Raceway
SITC of GI floor raceway of 100 x 38 mm of 1.6 mm thickness with Including PCC cutting of civil works if required.
SITC of 300 x 300 x 60-75 mm MS Floor junction box
SITC of 250 x 250 x 60-75 mm MS Floor junction box
SITC of 150 x 150 x 60-75 mm MS Floor junction box
SITC of POP-UP BOX 12 Module with 5 Socket 3/5 pin 6 Amp and 15 Amp Modular Switch with pre wired and flip flop pop up assembly in required matching color
HVAC WORKS
AIR COOLING & HEATING VRV/VRF SYSTEM SITC of air cooled VRV/VRF system complete for cooling and heating with Digital/Inverter Scroll Technology based outdoor units comprising condenser, scroll comresssors, etc. and indoor units comprising various types of evaporative blowers,electronic expansion valve, microprocessor based one cordless remote control and corded remote with each indoor units and charging the outdoor units by R-410 gas as required complete with all respect.
OUTDOOR UNITS: 18 HP HEATING -COOLING
IN-DOOR UNITS SITC of Indoor units equipped with pre-filter, fan section with low noise fan, multi-speed motor, coil section with DX coil, outer cabinet, drain pan, insulation, pipe connections, corded remote control etc. of various capacities as per specifications and drawings.
1.59 TR FOUR WAY CASSETTE TYPE
2.01 TR FOUR WAY CASSETTE TYPE
4.55 TR FOUR WAY CASSETTE TYPE
AIR COOLED VRV/VRF SYSTEM: TFA SITC of Design, Supply, Installation of Air Cooled VRV/VRF type airconditioning system complete with outdoor units comprising condenser, scroll/reciprocating comresssors, etc. and indoor units comprising 6 row coil & following air discharge and refrigeration capacities at an external static pressure of 25 mm wg , expansion device , microprocessor based remote controls, etc.
800 CFM ( 4.0 TR)
VRV/VRF SYSTEM
Supply and Drawing of 2c x 1.5 sqmm control cum transmission cabling/ power/ control cabling with PVC insulated, PVC sheathed, multi-core copper conductor control cable in suitable conduits between indoor and outdoor units and its remote controllers.
Installation, Testing, Commissioning of Y-joints/ T-joints
Supply and installation of copper refrigerant piping (Suction Line) of various sizes thickness complete with proper supports and Nitrile Rubber Tubular Insulation iwth Class '1' 19/100 mm etc. All related civil work such as making hole, chasing in wall, shall be inclusive in the quoted price.
Supply and installation of copper refrigerant piping (Liquid Line) of various sizes thickness complete with proper supports and Nitrile Rubber Tubular Insulation with Class '1' 13mm etc. All related civil work such as making hole, chasing in wall, shall be inclusive in the quoted price.
To supply, install, test and commission UPVC drain pipes and 'U ' traps from indoor units to nearest drain point.
32 mm dia
25 mm dia
AIR DISTRIBUTION/ EXHUAST SYSTEM
Supply, installation, testing and commissing of INLINE FANS for ventilation system. Each fan shall be complete with totally enclosed fan cooled motor, drive, motor mount & vibration isolators. Fan static pressure shall be 20 mm WG.
SITE FABRICATED DUCT
Supply, fabrication, installation, and testing of site Fabricated ducts of following thickness including necessary supports flexible hangers with isolators, nut bolts, gasket, splitter damper, volume control dampers, vanes, etc. complete as per specifications in accordance with the approved drawings.
24 gauge galvanised sheet
22 gauge galvanised sheet
19 mm thick Nitrile Rubber insulation (Density 65kg/m³) on ducts.
FLEXIBLE CONNECTION
Supply, fabrication, installation, and testing of canvas flexible connection constructed of fire resistant material as per the drawings /specifications.
Fire Detection and Alarm System
Supply, Installation, Testing & Commissioning of UL Listed and FM approved Microprocessor based redundant 1 loop capacity panel ,Networkable analogue addressable type fire alarm control panel with 80 character LCD display, each loop shall have a minimum capacity of 150 detectors & 150 devices analog in one loop. The panel shall have integrated QWERTY Keypad, 800 History logging event, Four access levels, capable of taking Flash Scan devices, flash EPROM, 240 volts AC power supply, automatic supervised battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and then be capable of operating the system for 30 Minutes in emergency conditions as required
Supply, Installation, Testing & Commissioning of UL Listed and FM approved addressable Self Acclimatising Multi Sensor smoke detector (AFC & BFC) with mounting based LED, to programme the detectors, complete as per all requirements of technical specifications & contracts works.r
Supply, Installation, Testing & Commissioning of UL listed and FM approved Intelligent Addressable microprocessor based, rate of rise and fixed temperature Heat detector with base.
Supply, Installation, Testing & Commissioning of UL listed and FM approved Single action Manual Pull Station. Shock and Vibration Resistant, Pull Down Lever Remains Down Until Reset. Shall be Polarity Insensitive.
Supply, Installation, Testing & Commissioning of UL listed and FM approved Intelligent addressable Output module having facility to activate sounders cum strobes etc.
Supply, Installation, Testing & Commissioning of UL listed and FM approved Line Isolator for isolating the section of circuit incase of short in the addressable Loop wiring.
Supply, Installation, Testing & Commissioning of UL listed and FM approved moniter module.
Supply and laying of 1.5 sq mm x 2 core copper Armd. with red outer sheath fire resistant electric cable (BS7629-1:2008-300/500V)
Supply, Installation, Testing & Commissioning of UL listed and FM approved control module.
Supply and Fixing ISI marked (IS : 15683) Portable Fire Exitnguisher, ABC type, finished externally with red enamel paint, complete in all respects including initial fill and wall suspension of following capacity: 9 KG
Providing and fixing ISI marked Portable Fire Extinguisher: CO2 4.5 kg capacity as per IS:2878
Video Surveillance
Supply, Installation, Testing and Commissioning of 2MP IR Dome 1/3" Progressive Scan CMOS, Min. Illumination 0.01 Lux @ (F1.2, AGC ON), 0 Lux with IR, IR Range 20 to 30 Mtr, Lens 4mm / 6mm, WDR 120 dB, Frame rate 50 Hz: 25 fps (1920 × 1080), 25 fps (1280 × 960), 25 fps (1280 × 720), ONVIF compliant, IP 66 rated, with mounting bracket as per site requirement.
Supply, Installation, Testing and Commissioning of 16 Ch NVR, 320 Mbps Bit Rate Input Max 4 SATA Interfaces, alarm I/O: 16/4, RAID 0,1,5,10 supported, 19" 3U case as per tender specification.
Supply, Installation, Testing & Commissioning of 8 TB Enterprice Level SATA-II Harddisk for Recording Storage.
PA (Public Announcement) System
Supply, Installation, Testing & Commissioning of 6W CEILING mount with max SPL1M/1W 101/92 dB . Frequency response of 160Hz-20KHz. The speaker shoud have tappings at 10/5/2.5 W. complete as required
Supply, installation, testing and commissioning of - 240 Watts amplifier with built in SD Card, FM, USB MP3 player Includingd Aux Input and compatibility for PA announcements. The amplifier shall also have arrangement for taking in data output form EPABX/FIRE Alram panel for announcements and Emergency Evac Prioritie
Supply and laying of 1.0 sq mm x 2 core oxygene free speaker wire in and including 25 mm dia rigid PVC conduit of FR grade with wall thickness of 1.6-1.8 mm (MMS Grade).
Rodent Repellent System
Supply, Installation, Testing and Commissioning of Master Console without satellites for Rodent Repellent system all Server Room and Hub Rooms.
Supply, Installation, Testing and Commissioning of Satellites to be installed with the Roden Repellant System at a minimum of 12 satellites per master console all Server Room and Hub Rooms
Supply and Surface Laying of 2 core x 0.5 Sq.mm copper cable flexible cable in 20mm dia PVC conduit
CCTV System
S/I/T/C IP 4MP indoor IR Camera with following specifications. The job includes all labor and petty material required to complete the job to the entire satisfaction of EIC. Image device: 1/2.5" CCD/ CMOS or better Resolution: Minimum 4 (MP) 2688x1520 Frame Rate: 30FPs@1080P Compression: H.264, H.265 Streaming: Multiple(upto 3 profile) Alarm: 1 Digital Input, 1 Relay Output Lens Type: 2.8 mm fixed True WDR 120 dB or better Minimum Illumination: 0.08 lux in color, 0 lux in B/W or Better IR Range: 30 Mtr. or better. Power Source (POE 802.3 af), 12 Volt Secondary Storage: Micro SD Card Up to 64 GB Supported Certification: UL/EN/BIS, CE, FCC certified Support Video Analytics Motion Detection, Tempering Alarm, Trip wire, Line Crossing
Fridge, Microwave Oven and Water Cooler
Providing and Installation of a microwave oven. The microwave oven shall be simple in operation and with turnable. Capable in microwave cooking and defrosting. Supply Voltage: 220 Volts, 50 Hz. Single phase A.C. Power Consumption: 1300W approx., Microwave Power: 700-850 Watts, Oven Capacity: 23-25 Ltrs, Microwave Frequency: 2450 MHz, Control: Soft/One touch control, Timer: 60-90 mins, Exterior Dimensions : 520mm(W) x 360mm(H) x 450mm(D) approx., Oven Dimensions : 330mm(W) x 220mm(H) x 330mm(D) approx. Accessories: Shall be supplied with a glass/ceramic tray.
Providing and installation of 4 Star BEE rated 240 Ltrs capacity Refrigerators with 10 year compressor warranty and 1 year warranty on entire refrigerator. Environment Friendly - 100% CFC, HCFC and HFC Free.
Providing and Installation of Stainless Steel Body water coolers having storage capacity of 80 ltrs and nominal cooling capacity of 40 ltrs/hr. No. of faucets: 2. Approx dimensions: 665 x 480 x 1210 weighing 47 Kg approx. Refrigerant - R134a. Compressor Type: RECIP.
Completed Charges with all expensive for Drawings (Civil, MEP Services of Electrical, HVAC, Fire Fighting, Plumbing) to accomplish the job related to Interiors and to submit the conceptual, working and As built drawings.
Description of Work / Item(s)
Amount
SITC of Silent DG Set (As per CPCB norms) complete with 1500 RPM Diesel Engine of suitable BHP & AC Brush less SPDP Alternator mounted on a common base Frame & coupled through a flexible coupling or close coupled. Alternator shall be self regulated with standard Alternator Protection( Over voltage, over speed & under voltage, under speed warning & shutdown). Engine shall have residential silencer, up to 3 M exhaust piping, electronic / Mechanical governor, Manual & electric Start, Batteries, Engine instruments panel, AVM and with Weatherproof, powder coated Accoustic enclosure for DG set for sound attenuation fabricated from 1.6 mm CRCA sheet steel (structure) with side wall fabricated from 1.6 mm CRCA sheet & filled with 100 mm thick glass wool (96Kg/m3)/Foam. as per IS 8183 the doors of 100 mm thick and fabricated from 1.6 mm CRCA sheet packed with accoustic material, canopy fixed with axial flow fan, All doors/ opening are sealed with neoprene/ EPDN gaskets. The enclosure has built in fuel tank, residential silencer (isolated from main DG chamber) with protection and tripping of DG set.
Radiator Cooled & Turbo Charged /AC
200 KVA at 0.8 pf 415V 50Hz 3-ǿ
Earth work in excavation/ by mechanical means (Hydraulic Excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sum on plan) including disposal of excavated earth, lead upto 50 m and lift upto 1.5 m, disposed earth to be levelled and neatly dressed:
Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in:
Dry Masonry.
Cement Mortar 1:6 ( 1-Cement : 6-Sand).
Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level.
M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size).
M15 grade Nominal Mix 1: 2: 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size).
Plaster on new surface on wall in cement sand mortar 1:3 including racking of joints etc. complete fine finish :
25 mm thick
LT Cable
P/Laying P.V.C. / XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor of IS:1554 P-I / IS :7098 P - I of Group 1 of approved make in ground as per IS:1255 including excavation of 30 cm x 75 cm size trench, 25 cm thick under layer of sand, IInd class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size.
PLC Based: 180 to 250 KVA
Earthing
Plate Earthing as per IS:3043 with Copper Earth plate of size 600 mm x 600 mm x 6.0 mm by embodying 3 to 4 mtr. below the ground level with 25 mm dia. G.I. 'B' class watering Pipe including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size 300 mm x 300 mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required.
Supply & Laying following size earth wire/strip in horizontal or vertical run in ground/ surface/ recess including riveting, soldering, saddles, making connection etc. as required.
25 mm x 5 mm Copper Strip
Air Conditioning
SITC of Interconnecting refrigerant pipe work with closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications including chase cutting, supports etc. as required.
Supply & Fixing of PVC trunking system for cable management including finishing accessories like corners, tee, adjustable angles, junction etc. as required. The trunking system shall have adaptable system for modular type RJ 45 data socket/ wiring accessories/ power sockets and shall be covered with peal off plastic cover.
150/160 mm x 50 mm
APFC Work
SITC of self healing MPP/MP type shunt capacitor (banks) conforming to IS:13340-41 / IEC :831-1&2 in existing panel or parallel with load terminals , the capacitor shall be fitted with discharge resistors, pressure sensitive disconnector (PSD) and shall have dissipation factor less than 0.0025 at 50 Hz and total wattage loss less than 0.5 Watt per KVAR. including making connections with suitable capacity conductors/cables testing etc. as required.
Heavy Duty Three phase 440 V, 50 Hz capacitor (Bank)
SITC of microprocessor based three phase sensing power factor correction relay having following sensing capacity secondary current, self analysing auto c/k setting according to targeted power factor setting, the relay shall have digit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current, insufficient compensation, indication of switching on units, auto/manual status, and shall have over load protection, no volt release, having multi parameter like KW, KVA, KVAR, metering facility as required.
12 to 14 stage
sensitivity up to 50 milli Amp
P & F Cam operated rotary switches on existing panel with 2 way and off position
Two Pole: 16 A
SF of 110/220 V, LED (22.5 mm dia) Indicating lamp with integral circuit, terminal block, including connection etc. as required.
Red/ Yellow/ Green Colour
P & F of 440 Volt 3 Pole capacitor (AC 6 B) duty contactor with 3 no. early make and post break auxiliary contacts in series with quick discharge damping resistors/ reactors to limit the inrush current, conforming to IS:13947-4-1/IEC:947-4-1, Din rail mounting type including making connections, testing etc. as required. suitable for following capacity capacitor bank.
7 to 10 KVAR
11 to 20 KVAR
P&F 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C/ D tripping characteristic) ISI marked IS 8828(1996)]/ conforming to IEC 60898 in existing board/sheets including making connections, testing etc. as required.
Triple pole MCB: 6 A to 32 A rating
SF of Current Transformer, with all necessary support in existing panel including connection etc. as required.
up to 150 / 5 Ratio, 5 VA, Class 1 accuracy
SF of (0-500) V range Volt meter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required.
Digital type
SF of CT operated direct reading type Ampere meter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required.
Below 500 A
Outdoor/ Indoor Panel
SITC of wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel made out of CRCA sheet, required hardware, duly treated for derusting in 7 tank process with dephosphating and with powder coating on both side of panel in desired shade The panel having PU/ Neoprene rubber gasket of not less than 3 mm thickness, separate detachable gland plate M.S. base channel, hinged door with locking arrangement for equipment/switchgear. Thickness of sheet shall not be less than 1.6 mm up to 600 mm length / width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartments having bolted type doors with / without detachable extension type structure. (only outer area on all sides shall be measured & panel to be fabricated from CPRI approved fabricator)
SITC of Fixed / Draw out type 4 pole Air Circuit Breaker conforming to IS 60947 p - 2 in existing LT panel suitable for LT installation 440 V, 50 Hz and having adjustable over load, short-circuit, earth fault and Thermal magnetic release with at least 4NO & 4NC auxiliary contacts safety shutter and fault position acknowledgement mechanism. type ACB shall have separate indication for service, test, isolation, maintenance position Breaking capacity Icu = Ics = Icw (1 sec) including making connections etc. as required.
Draw out type (Manual spring charged)
1600 A Rating, 50 / 65kA
SITC of quick make and quick break 4 POLE current limiting MCCB having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings and conforming to IS 60947-2 / IEC 60947-2 with front face and centralised adjustable, line load interchangeability, having positive isolation capability, provision for UVR , shunt trip, earth fault trip, push (test) to trip, including making connections with lugs & spreaders, etc. as required.
With Thermal Magnetic release
up to 100 Amp, 25 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu
200 Amp, 25/35kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu
250 Amp, 35 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu
400 Amp, 35 kA, adjustable O/L & adjustable S/C setting, Ics = 100 % Icu
Supplying and fixing of Aluminium / Copper bus bar by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves.
Electrolytic grade Aluminium bus bar
P & F of Multy function meter with LCD/ LED display capable of measuring electrical parameters like V, I, F, PF, KW, Kva, Kvar, Kwh, Kvah, Kvarh display with 1A/5A CT input for LV/ HV network, RS 485 communication port etc. complete in all respect.
SF of 110/220 V, LED (22.5 mm dia) Indicating lamp with integral circuit, terminal block, including connection etc. as required.
Red/ Yellow/ Green colour
Blue colour
S.I.T.C. of bus trunking arrangement in convenient sections complete with housing of galvanized sheet steel of minimum 1.5 mm thickness, aluminium bus bar for use on 3 phase, 4 wire, 415 volts, A.C. supply with degree of protection IP-42 for the following current carrying capacity, including jointing of sections, flexible joints. expansion joints, bends, and earthing with 2 runs of alum. strips etc. as required.
Decor Home India Pvt Ltd
Decor Home India Pvt Ltd
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .