Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 0 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance 86 MAHEWA EAST NAINI PRAYAGRAJ U P | PRAYAGRAJ | PRAYAGRAJ | UTTAR PRADESH | 211008 | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
5 Oct 2020, 6:00 pmClosed
GE AF Bamrauli
GE AF Bamrauli
REPAIR MAINT TO ROOF TREATMENT CHAJJA FOR PREVENTION OF SEEPAGE SUNKEN FLOOR PREVENTION OF SEEPAGE TO BLDG AND OTHER ALLIED MISC WORK UNDER AGE BR I AT BAMRAULI
2020_MES_375369_1
8600/E8
Open Tender
Civil Works
Item Rate
270 days
Bamrauli
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE AF Bamrauli
₹90,000
Yes
12 Oct 2020
7 Sept 2020
7 Oct 2020
7 Sept 2020
5 Oct 2020
23 Sept 2020
Amount
Dismantling of stone slabs and tiles of any description or thickness in floors, aprons, roof etc laid bedded and pointed in any mortar complete all as specified and directed.
M & L for taking down existing treatment (Tarfelt) includig plastering/screed bed on roof/wall of any thickness complete all as specified and directed.
Demolition of plain cement concrete in any description and in any position complete all as specified and directed.
M & L PCC 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate) as in padding on roof surface for correcting / making proper slope on roof, surface finished fair and even complete all as specified and directed.
Provision of Roof treatment consisting of the following items and operations complete all sepecifed and directed :- (a) M&L for rendering 10mm thick in cement mortar (1:4) over concrete surfaces of roof, mixed with liquid water proofing compound @ 200 ML per 50 Kg by weight of cement or as per manufacturers instruction including finishing surfaces even and fair without using extra cement complete all as specified and directed. (Water proofing compound will be measured and paid separately) (b) Cleaning the roof surface from dust / dirt and any other foreign materials and applying a coat of bituminious primer @ 0.30 liters per square meter uniformily after the surfaces fully dried complete all as specified and directed. (c) M&L for applying a coat of hot blown bitumen grade 85/25 conforming to IS 702 over primed surface of roof slab @ 1.20 Kg/Sqm complete all as specified and directed. (d) M&L for APP based polymeric water proofing membrane minimum weight 3 Kg / Sqm and minimum 3mm thick reinforced with polyster non wove fabric (weight not less than 150 gms/Sqm or as per IS), laid over hot bitumen surface by torched application with the strict supervision of manufacturers technical supervisor including cutting & chasing 100mm x 75mm in the parapet to insert the APP membrane and sealed with and including PCC (1:2:4) type B-0 (Mixed with and including polymer based liquid water proofing compound @ 200ML per 50 Kg by weight of cement or as per manufacturer’s specification. Membrane shall be laid with 100mm side/end lap on prepared surfaces as per manufacturer instruction. The work shall be carried out strictly with the technical tradesmen and supervision of technical staff of manufacturer.
M&L for 20mm thick PCC tiles machine pressed, factory made as per IS-1237-1980 laid over and including a bedding layer of 20mm screed in cement mortar (1:4). The cement mortar screed shall be mixed with polymer based liqiud water proof compound @ 200ML per 50 Kg by weight of cement or as per manufacturer's specification / instructions and tiles joints shall be filled with polymer based cement proof joint filler manufactured by approved manufactured for Approachable roof. (WPC shall be measured and paid separately)
Preparation of new APP based polymeric water proofing membrane surface and applying one coat of aluminium paint complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L for treating the sunken floor with preparing surfaces by brushing with wire brushes for removing caked mud etc. sweeping with brooms and finally fanning the cleaned surface with gunny bags to remove all loose dirt etc, applying consisting of the following operation (a) 10mm thick plaster/screed bed in cement mortar 1:3 complete mixed with water proofing compound as per manufactures instructions complete all as specified & directed (Note- WPC shall be measured and paid separately) (B) Cleaning floor surface by wire brush brooming & removing dust & shall be painted with a coat of bituminous primer conforming to IS; 3384-1986 @ 0.3 Ltr per sqm uniformily complete all as specified & directed (c) After primer the entire surface applying tack coat of hot blown bitumen grade 85/25 grade conforming to 702-1988 @ 1.2 kg per sqm over primer (d) Over hot bitumen laying polymeric water proofing membrance consisting of 90 to 100 micron thick center core of HMHDPE Film with standard weight not less than 3 Kg per Sqm over entire area laid with 100mm side lap/end lap on prepared surfaces as per manufacture's technical instruction & sealed complete all as specified & directed (e) Again the entire floor surface applying tack coat of hot blown bitumen grade 85/25 grade conforming to IS 702 @ 1.2 kg per Sqm complete all as specified and directed.
M&L broken bricks hardcore of gauge n exc. 63 mm , deposited , spread and levelled in layer n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for cement concrete (1:5:10), type E-2 (using 40 mm graded stone aggregate) as in , sub base etc mixed with liquid water proofing compound @200 ML per 50 Kg by weight of cement or as per manufacturers instruction including finishing surfaces even and smooth without using extra cement complete all as specified and directed.
M & L for 25mm thick PCC (1:2:4) type B-0 (using 20 mm graded stone aggregate) as in leveling course to floor complete all as specified and directed.
M&L for non skid ceramic coloured tiles (Ist quality) 7 to 8mm thick (Square/rectangular), area of each tile exc 0.11 Sqm but n.exc 0.18 sqm as in floors etc set and jointed in neat grey cement slurry and pointed in white or coloured cement to match, laid over and including 15 mm thick screed bed in CM (1:6) complete all as specified and directed.
M&L for coloured glazed ceramic tiles (Ist quality) of size350x250x 6 to7mm/450x350x6 to 7mm thick on vertical surfaces such as skirting, dado and rises to steps etc., set and jointed in neat cement slurry and pointed in white or colour cement to match the colour of tiles fixed over and including 10 mm thick backing coat in cement mortar (1:4) complete all as specified and directed.
Disconnecting existing tanks of capacity exc 250 & n.exc 500 ltrs, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required, reconnection and re-fixing in position after cleaning and repairing etc. complete all as specified and directed.
Disconnecting existing tanks of capacity exc 500 & n.exc 1000 ltrs, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required, reconnection and re-fixing in position after cleaning and repairing etc. complete all as specified and directed.
Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc. capacity exc 250 ltrs n. exc 500 Ltrs complete all as specified and directed including writing date of cleaning with suitable paint.
Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc. capacity exc 500 ltrs n. exc 1000 Ltrs complete all as specified and directed including writing date of cleaning with suitable paint.
S & F 500 litres capacity rotational moulded polyethylene water storage tanks triple layer,white colour (Cylindrical/vertical with closed top) ISI embossed hoisted and fixed in position including taking down old tank all as specified and directed.
S & F 1000 litres capacity rotational moulded polyethylene water storage tanks triple layer,white colour (Cylindrical/vertical with closed top) ISI embossed hoisted and fixed in position including taking down old tank all as specified and directed.
S&F in repair ball valve high pressure PTMT with epoxy coated aluminium rod and high density plastic ball complete screwed for iron pipe or brass ferule & fixed for 20mm bore of pipe all as specified & directed.
Taking up or down 15 mm dia steel tubing and connections and set a side for refixing or removal to store complete all as specified and directed.
Taking up or down 20 mm dia steel tubing and connections and set a side for refixing or removal to store complete all as specified and directed.
Supply and fixing 15 mm bore galvanised steel water tubing 'medium grade' with all fittings and fixed to walls, ceiling or laid in floors etc. complete all as specified and directed.
Supply and fixing 20 mm bore galvanised steel water tubing 'medium grade' with all fittings and fixed to walls, ceiling or laid in floors etc. complete all as specified and directed.
Refixing old 15 mm bore galvanised steel water tubing 'medium grade' obtained from taking down with provision of all new fittings and fixed to walls, ceiling or laid in floors etc. including cleaning of old pipes complete all as specified and directed.
Refixing old 20 mm bore galvanised steel water tubing 'medium grade' obtained from taking down with provision of all new fittings and fixed to walls, ceiling or laid in floors etc. including cleaning of old pipes complete all as specified and directed.
M&L for Cutting chases to brick walls, pinning in, making good to facings where required and making good in cement mortar (1:3) cuttings exceeding 10cm girth for concealed water tubing or concealed conduit wiring, etc.complete all as specified and directed.
Dismantling of brick work or stone mansonry, built in cement mortar including all quoins, pillars etc complete all as specified and directed
M&L for brick work with sub-class 'B' bricks, straight or curved on plan exceeding 6M mean radius, built in cement mortar (1:6) complete all as specified and directed
Taking down old cement plaster or cement lime plaster of any description on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for rendering 15mm thick in CM (1:6) on fair faces of brick work or concrete surfaces of walls, finished even & smooth without using extra cement complete all as specified and directed.
M&L for 15mm thick rendering on fair faces of brick or concrete surface in CM (1:4) finished even & smooth without using extra cement mix with liquid water proofing compound complete all as specified. Note : Liquid water proofing compound will be measured and paid separately.
M & L 5 mm thick rendering in cement mortar 1:4 on brick work or concrete surface on ceiling finished even and smooth without using extra cement complete all as specified and directed.
Supply only liquid integral waterproofing compound etc complete all as specified and directed.
Preparation of new plastered surface of wall and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed.
M&L for two coats oil bound distemper on newly plastered surfaces on wall over a coat of primer all as specified including preparation of surfaces complete all as specified and directed.
M&L for two coats oil bound distemper on newly plastered surfaces on wall over a coat of primer including over a coat of wall care putty including preparation of surfaces complete all as specified and directed.
M&L for preparation of newly plastered wall surface and applying three coats of white wash complete all as specified and as directed.
M&L for preparation of newly plastered ceiling surface and applying three coats of white wash complete all as specified and as directed.
S&F in repair gun metal, globe or gate valves 20 mm dia, with iron wheel head, screwed both ends for iron pipe all as specified and directed.
Preparation of old decorated plastered wall surfaces and applying one coat of cement base paint complete all as specified and directed.
Demolition and breaking up PVC drain pipes of 75/110mm dia as in wall/floor complete all as specified and directed.
S&F 75 mm bore PVC (SWR) bends any radius with acess door complete all as specified and directed
S&F 110 mm bore PVC (SWR) bends any radius with acess door complete all as specified and directed
S & F of 75mm bore PVC (SWR) junction single 'T' equal or unequal with acess door complete all as specified and directed
S & F of 110 mm bore PVC (SWR) junction single 'T' equal or unequal with acess door complete all as specified and directed
S & F of 110 mm bore PVC (SWR) Vent cowl complete all as specified and directed.
S & F of 75 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls complete all as specified and directed
S & F of 110 mm dia(SWR) pipes single socketed, in any length with rubber ring joints fixed to walls complete all as specified and directed
M & L for repairing of RCC projection, chajjas, roofs facia, column etc by necessary preparation i.e scrapping, cutting, chiseling and cleaning exposed reinforcement, surfaces of damaged, loosed RCC srfaces and applying one coat of cement slurry and filling the surfaces with cement concrete (1:1.5:3) using 12.50mm graded stone aggregate and reinforced with welded mesh of weight exc 2kg per Sqm but not exc 3kg/sqm with or without facia and finished exc 5Sqm each and thickness of RCC member n.exc 70mm at any height complete all as specified and as directed. Note : Cost of formwork and welded mesh are deemed to be included in unit rate quoted.
S&F in repairs Vitreous china squating pan " Orissa pattern, size 580 x 440 mm white, with integral foot rest (excluding flushing cistern and flush pipe) incl P or S trap connection to trap, and to flushing pipe anti syphonoge pipe etc incl making good to floor complete all as specified and directed.
S& F PVC valve less, syphonic action type, white low level flushing cistern of capacity 10 litre with inlet ball valve float and handle including brackets and 32 mm dia PVC flush pipe complete all as specified and directed.
S&F in repair Vitrious China wash basin, white, flat back, size 550x400mm excluding taps, waste chain and plugs and porcelain stopper but including bracket complete all as specified and directed.
S&F in repairs pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly nuts, screwed for iron pipe of bore of pipe 15mm complete all as specified and directed.
S&F 32mm dia waste fittings, brass, cromium plated for glazed ware sinks, basin etc with long screwed shanks and flynuts flange end complete all as specified and directed.
S&F low density PVC connection commercial quality 450 mm long including PTMT nuts at both sides of 15mm bore and fixed, complete all as specified and directed.
S&F in repair Swivel shower of chromium plated of size 125 mm for fixing with 15mm bore pipe complete all as specified and diected.
S&F in repair CP brass bib cock ,cast copper alloy with butterfly handle, screwed down screwed for iron pipe or for brass ferule of 15mm bore Cat. No.: F200003 of Hindware or equivalent model in Cera/Jaquar complete all as specified and diected.
S&F in repair stop valve cast copper alloy screwed down high pressure with capston head handle chromium plated concealed type screwed both ends for iron pipe 15 mm bore or for unions and fixed Cat. No.: F200007 of Hindware or equivalent model in Cera/Jaquar complete all as specified and diected.
S&F in repair stop valve cast copper alloy screwed down high pressure with with butterfly handle, screwed down, screwed for iron pipe or for brass ferule of 15mm bore or for unions and fixed Cat. No.: F200005 of Hindware or equivalent model in Cera/Jaquar complete all as specified and diected.
S&F PVC (SWR) floor trap, plain with CP grating including jointing with solvent cement, in 75 mm diameter of outlet complete all as specified and diected.
S&F in repair tubular towel rail 20 mm dia, D type 60 cm long between flanges brass chromium plated complete all as specified and directed.
S&F in repair 32 mm bore Low density polyethylene pipes (LDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc complete all as specified and as directed.
Dismantling timber scantlings in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in framed section complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
Dismantling Asbestors cement (corrugated semicorrugated,etc) sheet roof coverings complete all as specified and as directed.
M&L for asbestos cement 6 mm thick corrugated or semi corrugated sheets in roofs, walls etc, fixed with L or J type or cranked hook bolts complete all as specified and as directed.
M&L asbestos cement 6 mm thick two ceserrated ridge for corrugated or semi corrugated sheets, fixed with L or J type or cranked hook bolts incl dismantling of old ridge complete all as specified and as directed.
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an any colours having tensil strength of 550 Mpa as in roof covering or fixed to wall fixed with self tapping screws complete all as specified and as directed.
Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
M & L for PCC (1:3:6) type C-2 (using 40 mm graded stone aggregate) as in foundation, sub base / mass concrete etc complete all as specified and as directed.
S&F steel work in hollow structural pipes as in post/ Rafters/purlins and trusses special shaped washer including clamp and bolt complete using ERW or induction but welded tubes comforming to IS complete all as specified and directed.
Preparation of new surfaces of steel of any description over 10cm grith or width, not otherwise described and applying two coats of synthetic enamel paint over a coat of redoxide primer complete all as specified and directed.
Demolition of cement concrete(unreinforced) as in ground floor and paving n exc 15cm thickness (below or above GL) incl the disposal upto 50M complete all as specified and diected.
M&L for PCC (1:4:8) type D2 (using 40mm graded stone aggregate) in foundation, filling and mass concrete complete all as specified and directed.
M&L sand filling under floors or in foundations including watering and consolidation for interlocking tiles complete all as specified and directed.
M&L for machine pressed precast concrete interlocking paver blocks of any shape and size confirming to IS 15658-2006 of 60mm thickness with grey cement and pigment and the grade of concrete shall not be less then M- 35 grade complete all as specified and directed.
M&L for heavy duty plain/ chequered coloured tiles of size 300mmx300mm x12mm thick ( Durastone of somany ( highway/ taffic) or endura of Johnson equivalent of other specified make hardwearing floor tiles as in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15mm thick screeding in CM 1:4 complete all as specified and as directed.
Taking down chowkats or frame of any description with shutters (without taking off shutter from the frame) area exc 1.5 Sqm but not exc 1.5 Sqm each and removing from the site incl cutting holes for holdfasts including making good in CM 1:3/PCC 1:2:4 type BO complete all as specified and diected.
S & F factory made PVC door frames of size 50mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube suitable for opening as per site condition complete all as specified and directed and shown on page No. 160 of SSR part-II
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tube for top and bottom rail. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement including 2 Nos aluminium handle 150mm long and 2 Nos aluminium tower bolt 200mm long and 3 Nos aluminium hinges 100 mm long fixed to each shutter complete all as specified in drawing on sl page No 156 of SSR 2010 part -II and directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation. etc) or insulation boards/slabs/blankets, any thickness, including cover fillets all as specified and directed.
Supply, fixing in position premium sand texured finished mineral fibre acoustical ceiling tiles of size 600x600x16mm thick and placed on GI grid powder coated snap grid ceiling, 600x600 module consisting of wall angle section 24x24 mm and tee section with web height of 38mm and flange 24mm (colour white) (having rotary stiching on all T-section) with suspension system as shown in drawing No CWE/BAM/TD-34 She 1/1 and as approved by the GE including taking down old false ceiling complete all as specified and directed. Note :- (i) Ceiling tiles shall be of make Armstrong brand "DUNE RH99 (Bevelled / Tegular)" or equivalent brand of make as specified in Appendix 'B' to particular specifications. (ii) Thickness of GI section shall not be less than 3mm and shall be procured from the tile manufacturer. (iii) Section and hanging system shall have galvanizing of minimum 90 grams per square metre and of same make of tile. (iv) Work shall be executed by the manufacturer's authorised agency. (v) Old false ceiling shall be contractor property and necessary recovery shall be made as per rate specified in schedule of credit.
M&L PCC 1:2:4 type B1 (using 20mm graded aggregate) as in coping including necessary form work, bed block etc all as specified and directed.
Note :- Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material.
M/S Shivam Industries
Z N Enterprises
M/s M A Traders
oasis contractor builder and supplier
A S ENTERPRISES
MOHAMMAD RIZWAN CONTRACTOR
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .