| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.3 LAccepted-AOC B BLOCK 2 3 RAM BACHAN V B NAGAR PIPE ROAD KURLA W MUMBAI 400070 | MUMBAI SUBURBAN | MAHARASHTRA | 400070 | L1 | Accepted-AOC Being Lowest tenderer | |
| 2 | L2₹32.1 L+₹1.3 L (4.38%)Rejected-Finance NOT AVAILABLE | L2 | Rejected-Finance Being other than Lowest Tenderer | |
| 3 | L3₹35.4 L+₹4.7 L (15.2%)Rejected-Finance | L3 | Rejected-Finance Being other than Lowest Tenderer | |
| 4 | L4₹35.5 L+₹4.8 L (15.6%)Rejected-Finance | L4 | Rejected-Finance Being other than Lowest Tenderer | |
| 5 | L5₹37.0 L+₹6.3 L (20.4%)Rejected-Finance | L5 | Rejected-Finance Being other than Lowest Tenderer |
Tender Value
₹45.3 L
EMD Value
₹90,520
Closing Date
30 May 2023, 6:00 pmClosed
Lt Col Ng Rajesh Singh GE NW KUNJALI
GARRISON ENGINEER NW KUNJALI DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI 400005
8934 SPECIAL REPAIRS TO SHORT FIRING RANGE AT INS KUNJALI AND PROVISION OF EXTERNAL SUN SHADES OVER WINDOWS INCLUDING CONNECTED WORKS IN MAIN BUILDINGS AT BASE VICTULATING YARD COLABA MUMBAI UNDER GE NW KUNJALI
2023_MES_592751_1
8934/E8
Open Tender
Civil Works
Item Rate
183 days
GE (NW) KUNJALI
Please refer tender documents
7 documents required · 7 mandatory
₹500
Yes
GE (NW) KUNJALI
₹90,520
Yes
27 Oct 2023
2 May 2023
1 Jun 2023
9 May 2023
30 May 2023
16 May 2023
2 May 2023 - 9 May 2023
Amount
Dismantling plain or corrugated steel/AC roof sheets any gauge, thickness, including Nainital or similar pattern roof covering all as specified and directed.
S&F pre-painted galvalume aluminium zinc coated GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, chajjas, fixed with self tapping screws as specified.
S&F pre-painted galvalume aluminium zinc coated GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, chajjas, valley gutter, ridge and fixed with crumple joint etc fixed with self tapping screws as specified.
Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified.
S&F roof trusses (framed), trussed, purlins,crane gantries, rails and fastnings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.conforming to Fe 410 Gd E-250 all as specified .
Bands, straps, supports or stays for rainwater , , including bolts , if required; hooks ( stay), heavy, for large gates; hook and pintal hinges; large hasps and staples ; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters ; , plate washers and similar small articles conforming to Fe-290 Gde-E- 165
M&L for preparation of old painted steel surfaces of any description, over 10 cm in width or girth not otherwise described and applying one coat of synthetic enamel paint with necessary scaffolding for high rise bldgs etc all as specified and directed.
M&L for preparation of new steel surfaces of any description over 10 cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified and directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles and disposing off complete all as specified and as directed.
Excavating in trenches, n.exc 1.5 M wide and n.exc 1.5 M in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc n.exc 10 Sqm on plan and n.exc 1.5 M in depth and gettging out in hard using dense soils all as specified.
M&L for PCC 1:3:6 type C-2 ( Using 40 mm graded stone aggregate) as in foundation, filling and mass concrete
M&L for stone walling of random rubble, uncoursed brought upto courses, well bonded, bedded and solidly hearted, built in cement mortar 1:4 all as specified.
M&L for brick work with sub class B bricks straight or curved on plan exceeding 6 m mean radius built in CM 1:3 complete all as specified and as directed.
M&L for brick work with sub class B bricks straight or curved on plan exceeding 6 m mean radius built in CM 1:6 complete all as specified and as directed.
Returning filling in including spreading, levelling watering and well ramming in layers not exc 25 cm in hard/dense soil.
Removing excavated hard/dense soil n exc 250 mtr and depositing where directed at a level n exc 1.5 m above the starting point
Taking down cement or cement lime plaster, any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc including all necessary scaffolding as required and rubbishing off the premises etc complete all as specified and as directed.
M&L for Plastering 15mm thick in CM 1:6 on brick surfaces, finished even and smooth without using extra cement.
Rendering 15mm thick on brick work or concrete surfaces in cement mortar 1:4 finished even and fair including mixing integral water proofing compound in the proportion per manufacturer's instructions complete all as specified. (Note : Water proofing compound to be measured and paid for separately).
Supply only integral water proofing compound.
M & L for rendering 20mm thick in two coats(15mm inner coat and 5mm finishing coat) on brick work or concrete surfaces in cement mortar 1:4 finished even and fair including mixing integral water proofing compound in the proportion as per manufacturer's instructions, including necessary scaffolding for etc all as specified and directed. (Note : Water proofing compound to be measured and paid for separately).
S&F in repair Steel wire fabric (n exc 4 Kg per Sqm ) to wall,wood or steel members including fixing with galvanised steel staples or nails complete all as specified.
M&L for Preparation of newly plastered surfaces of wall and applying two coats of oil bound distemper over a coat of of primer all as specified and directed.
M&L for Complete removal of existing treatment on wall surfaces by scrapping, washing & rubbing down with water and applying two coats of oil bound distemper over a coat of primer.
M&L for preparation of old decorated surfaces of wall and applying one coat of oil emulsion distemper all as specified and directed
M&L for applying 1 to 2 mm thick wall care putty (JK/Birla) for making the surface even & smooth all as specified and directed by the Engineer-in-Charge.
M&L for preparation of newly plastered surfaces of wall, soffits, facia roof and applying two coats of weather proof acrylic based paint (100% acrylic) over one coat of cement based primer with necesssary scaffolding for high rise bldgs etc all as specified and directed.
M&L for Complete removal of existing treatment of old decorated surfaces of walls soffits, facia roof and applying two coat of weather proof acrylic based paint (100% acrylic) over one coat of cement based primer with necessary scaffolding for high rise bldgs. etc all as specified.
M&L for preparation of old decorated surfaces of walls, soffits, roof facia and applying one coat of weather proof acrylic based paint (100% acrylic) with necessary scaffolding for high rise bldgs etc all as specified and directed.
M&L for Sand Filling under floors or in foundation including watering and consolidation.
Forming embankments including raising (or lowering) earth, spreading in layers n exc 0.30cm thick, watering,ramming/rolling and finishing to required size, shapes etc, not exc. 1.50 m ht from base complete all as specified.
Dismantling stone slab and tiles of any description or thickness laid bedded and pointed in any mortar in floors, aprons etc all as specified and directed.
M&L for 20 mm thick Granite (of any type) work (table rubbed and polished) as in steps, jambs, pillars, window- cills,cooking platforms, working table and like over 20 mm thick screed bed or bedding layer in cement mortar (1:4), including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite
M &L for machine cut kota stone slab flooring 18 to 20 mm thick as in steps, landings, floors etc laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing,mirror polishing incl making 02 Nos grooves in steps over & incl 20 mm thick screed bed in cement mortar 1:4 complete all as specified and directed.
M &L for machine cut kota stone slab 18 to 20 mm thick as in skirting/vertical surfaces jointed and pointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, polishing and 15 mm thick backing coat in cement mortar 1:4 complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floor and in paving not exceeding 15 cm thickness (below or above ground level) complete all as specified.
Providing plain cement concrete type B-1, 1:2:4 (using 20 mm graded stone agg) as in lintels upto 1.5 M clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railing upto 60 cm in height, copings, kneelers, apex stones, bed plates, roof kerbs, water troughs and the like including weathering slightly rounded or chamfered angles and throating all as directed.
M&L for 100 mm thick cement concrete 1:4:8 type D-2 (Using 40 mm graded stone agg) as in sub base.
Taking down chowkats or frames but n exc 1.5 sqm each but with shutters (without taking off shutters from the frame)
Taking down chowkats or frames exc 1.5 sqm but n exc 4 sqm each but with shutters (without taking off shutters from the frame)
S&F 2nd class hard wood (sal) plain, solid, straight chawkhats and frames, wrought, framed, rebated on the solid rounded or chamfered, put together with glue pinned at joints all as specified.
S&F 35mm thick factory made 2nd class HW rail & stile plain framed , panelled shutter ( two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS: 1003 ( Part I), kiln seasoned and chemically pressure treated
S&F 40mm thick flush shutters, solid core construction, with block board core and ply wood face panels, commercial type on both side.
S&F powder coated aluminium (minimum 25 micron thickness of coating) of various section as required for doors, window & partion/Ventilator etc including fixing and making the frames hinges to receive glass/wire gauge etc. Complete incl all fittings like rubber beading, clips locking arrangement, handle, tower bolt for shutter, sealant etc all as specified and as directed by Engr- in- charge.
S&F aluminium grill with and including suitable aluminium anodised frame F/H section as requird manufactured by M/S Decogrill as per design No DG- 102, 7.5 mm thick all as specified and as directed by Engr- in- charge.
S&F 300 mm long aluminium alloy, sliding door bolt with hasp & staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts all as specified.
S&F aluminium anodized barrel tower bolts 150 mm of extruded section.
S&F 150 mm size aluminium alloy handles, fabricated type extruded section, ISI marked all as specified.
S&F 100mm size aluminium alloy handles, fabricated type extruded section, ISI marked all as specified.
S&F butt hinges 100 mm mild steel hinges medium weight.
S&F 3 mm thick aluminium composite panel cladding plain of approved colour/shade to beam/column/slab incircular/rectangular shape inbcluding cutting, notching, bending to shape as required jointing with silicon gel of approved colour & aluminum tubular hollow section 25 x 25 mm not exceeding 900 mm C/C on exceeding column/beam/slab to hold APC cladding etc (Note : colour/pattern of ACP sheet will be approved by GE).
M&L for plain cement concrete 1:2:4 type B-1 (using 20 mm graded stone agg) as in surface channels and drains all as specified.
M&L for preparation of old painted wooden surfaes of any description over 10cm width or girth and applying one coat of synthetic enamel paint including external window with necessary scaffolding for high rise bldgs.
M&L for preparation of new wooden surfaes of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer incl preparation of surfaces.
M&L for Fibrette tile made of wood fiber Cement Composite 1mm width wood fiber 15mm thick size 595x595/595x1195 mm having excellent noise absorption of 1 NRC as per ISO 354, density 400 Kg/m3 meets Fire ratings as per BS 476 Part 5,6 and 7 class 1 and P, water resistant and thermal insulated, Installed on T24 grid system of 0.6mm thick main 'T' length minimum 3000mm, web minimum 35mm to be placed at 600mm center to center and secondary cross 'T' of length 600mm web minimum 35mm inter locked. Wire support for Maint T to be taken at every 1200 length wise and 600mm width wise, with a backing of 50mm 1000GSM thick absorb wool tested as per Fire Retardent IS 15061-2002 for excellent results.
S&F mild steel framed work such as grills, gratings, chequred plates etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bar; barred iron doors; ladder; framed balusters; walkj ways, railings, frame work for water tanks and similar work conforming to Fe 290 Gd E-165 all as specified .
M&L for 75mm thick cement concrete 1:3:6 type C-2 (40 mm graded stone agg) as in sub base.
M&L for machine pressed precast concrete inter locking paver block any shape and size confirming to IS-15658-2006 of 60mm thickness M-35 Grade, glossy finished of approved colour laid over and including 25 mm thick fine sand cushion to a line and slope etc and joined complete including spreading screened river sand over surface for filling the joints with rising surface vibrator etc complete all as specified .
M&L for machine pressed chequered cement coloured tiles of size 250mmx250mmx20mm thick mix with grey cement and pigment laid over 15mm thick screed bed in CM 1:4 set and jointed and pointed in neat cement slurry in floors complete all as specified and direcetd.
M & L for PCC 1:3:6 type C2 (using 40mm graded stone aggregate ) as in plinth protection and similar works 75mm thick finished fair and smooth without using extra cement complete.
S&F 4mm thick bakelite sheet with decoratie choice laminated on both side complete all as specified and as directed.
M&L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending , hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia.
M & L for cement Concrete type B1 1:2:4 (Using 20 mm graded stone agg) as in coping including weathering, slightly rounded or chamfered angles and throating as directed.
Disconnecting & taking down, strip opening, cleaning all parts and packing of ceiling fan of any make and size & greasing ball bearing with specified quality grease including replacement of rubber reel with nut, bolts, split pins & re-assembling the ceiling fan as a one unit, complete all as specified.
M&L for hanging ceiling fan in position & re-comissioning the same including making electric connection complete all as specified & directed
All as per Item No. 66 here in before but of exhaust fan any make & size complete all as specified.
M&L for fixing Exhaust fan in position & re-commissioning the same including making electric connection complete all as specified and directed.
Preparation of old painted surfaces of ceiling fan of any make & size & applying one coat of synthetic enamel white paint by spray painting including marking of MES No/Unit name bottom of the fan by applying balck paint complete all as specified & directed by EIC.
All as per srl No 69 above but using gray paint/green paint for exhaust fan any size & make all as specified.
Taking down carefully old U/S point wiring copper/Aluminum (light/ fan /sockets/power) complete with switches, sockets, fan regulators, ceiling roses, lamp holders, brackets, removing material to store for keeping in safe custody and making good to disturbed surfaces as directed by Engineer-in-Charge
M&L for sub-main wiring with 2 runs of 2.5 sqmm copper conductor cable (FRLS grade), 1100 volts grade PVC insulated and unsheathed multi-stranded, drawn in and including heavy grade PVC casing and capping not less than 25mm dia (internal width) with all accessories like tees, elbows, junction boxs, reducer etc as required, including one run of 2.5 sqmm dia PVC insulated unsheathed copper conductor cable as earth dolly/mains, with all accessories like PVC elbow, PVC tee, etc including taking up/down old unserviceable sub main wiring and making good the distrubed surfaces/location complete all as specified and directed. Note: (a) Colour coding shall be followed as (i) Phase- Red/Yellow/Blue (ii) Neutral - Black (iii) Earth - green (b) Make of wire : Polycab/ Havells/ Finolex/Gloster (c) Make of PVC casing capping/Conduit :- Precision/ pesto plast / National/Plaza
M&L for sub-main wiring with 2 runs of 4.0sqmm copper conductor cable (FRLS grade), 1100 volts grade PVC insulated and unsheathed multi-stranded, drawn in and including heavy grade PVC casing capping not less than 25mm dia (internal width) with all accessories like tees, elbows, junction boxs, reducer etc as required, including one run of 4.0sqmm dia PVC insulated unsheathed copper conductor cable as earth dolly/mains, with all accessories like PVC elbow, PVC tee, etc including taking up/down old unserviceable sub main wiring and making good the distrubed surfaces/location complete all as specified and directed. Note: (a) Colour coding shall be followed as (i) Phase- Red/Yellow/Blue (ii) Neutral - Black (iii) Earth - green (b) Make of wire : Polycab/ Havells/ Finolex/Gloster (c) Make of PVC casing capping/Conduit :- Precision/ pesto plast / National/Plaza
M&L for sub-main wiring with 4 runs of 10.0sqmm copper conductor cable (FRLS grade), 1100 volts grade PVC insulated and unsheathed multi-stranded, drawn in and including heavy grade Capping casing not less than 25mm dia (internal width) with all accessories like tees, elbows, junction boxs, reducer etc as required, including one run of 10.0sqmm dia PVC insulated unsheathed copper conductor cable as earth dolly/mains, with all accessories like PVC elbow, PVC tee, etc including making good the distrubed surfaces/location complete all as specified and directed. Note: (a) Colour coding shall be followed as (i) Phase- Red/Yellow/Blue (ii) Neutral - Black (iii) Earth - green (b) Make of wire : Polycab/ Havells/ Finolex/Gloster/Plaza (c) Make of PVC casing capping :- Precision/ pesto plast / National/Plaza
S&F in repair of double door type SPN DB 08 Way ,240V with 100A copper busbar each phase , with mettalic double door type IP-43 IK 09 protection suitable for housing MCB's all as specified and directed by EIC. Make: Legrand cat No 507611 /Seimens/C&S. Note : MCB DBs shall be concealed in wall where ever posible including making good the surface to match with surrounding.
S & F MCB SP 6-32 Amps,10KA, 'C' series 240V complete all as specified and directed. Make:Schinder/Seimens/C&S
S & F MCB SPN 40 Amps,10KA 'C' series 240V complete all as specified and directed. Make:Schinder/Seimens/C&S
M&L for point wiring complete with 1.5 Sq.mm single core multistranded PVC insulated & unsheathed copper conductors cable 1100 volts FRLS grade ISI make and drawn through & including PVC non metallic casing and capping with Accessories fixed on wall/ceiling/truss etc with PVC non metallic ISI make terminal boxes fixed on wall including one PVC insulated & unsheathed multistranded copper conductor 1.5 Sq. mm as earth continuity conductor connected to common earth dolly including modular box with cover plate frame in any module complete fixed on wall for fixing the switches, switch, socket all as specified for following :- NOTE: a) Colour coding shall be followed as given below:- i) Phase - Red/Yellow/Blue ii) Neutral - Black iii) Earth - Green b) Electrical wiring above false ceiling shall be drawn through non mettalic rigid PVC conduit.
(a) One light point controlled by one 5A switch
(b) One Fan/exhaust point controlled by one 5A switch
(c) One 5A switch socket combination on the same board
(d) One 5A switch socket point on independent board
M&L for point wiring complete with proper colour coding using PVC insulated unsheathed multistranded copper conductor cable 4.0 sqmm size, 1100 volts ISI marked, FRLS grade drawn through and including non mettalic rigid, double lock, ISI marked, not less than 25mm casing capping with all accessories such as tee, bends, elbow, reducers, junction box etc fixed on wall/ceiling/truss and one run of PVC insulated unsheathed, multistranded copper conductor cable of 2.5sqmm size, 1100 volts, ISI marked, FRLS grade green colour as earth continuty conductor connected to common earth dolly with and including modular box with cover plate frame in any module complete fixed on wall complete comprising of 02 Nos 6A sockets and 01 No 15A socket on same board complete all as specified and directed. Note: (a) Colour coding shall be followed as (i) Phase- Red/Yellow/Blue (ii) Neutral - Black (iii) Earth - green
M&L for point wiring complete with 2.5Sq. mm single core multistranded PVC insulated & unsheathed copper conductors cable 1100 volts FRLS grade ISI make and drawn through & including PVC non metallic casing and capping with Accessories fixed on wall/ceiling/truss etc with PVC moulded box/ hylem sheet ISI marked fixed on wall including one PVC insulated & unsheathed multistranded copper conductor 2.5Sq. mm as earth continuity conductor connected to common earth dolly for 15 amp swich socket on independant board complete including modular box with cover plate frame in any module complete complete fixed on wall for fixing the switches, switch, socket all as specified. Note: (a) Colour coding shall be followed as (i) Phase- Red/Yellow/Blue (ii) Neutral - Black (iii) Earth - green
S & F ceiling rose surface bakelite 65 x 50mm, flush type, 3 terminals complete all as specified and directed by EIC.
S & F modular switch 1 way 6A,1 module all as specified and directed by EIC. Anchor/Roma/Legrand/C&S/Goldmedal
S & F modular switch 1 way 16A,1 module all as specified and directed by EIC. Make: Anchor/Roma/Legrand/C&S/Goldmedal
S & F modular socket, 6A - 2/3 pin combined 2 modules all as specified and directed by EIC. Anchor/Roma/Legrand/C&S/Goldmedal
S & F modular socket 6/16A,2/3 pin, combined 2 module all as specified and directed by EIC. Anchor/Roma/Legrand/C&S/Goldmedal
S&F for modular fan step regulator, 120W - 2 modular all as specified and directed by EIC. Anchor/Roma/Legrand/C&S/Goldmedal
S & F lamp holder PVC/polycarbonate insulated body type complete all as directed. Make : C&S cat No ACBHA006/Anchor/Roma
Supply and fixing in repair new generation walll/surface mounted bulk head LED fitting 10W, provides high quality ecomonic energy saving lighting complete with all accessories internally pre-wired and including fixing the fitting on wall/ceiling including connecting up with copper conductor cable with suitable size and all as directed by Engr-in-Charge. Make : CG /Wipro/Philips/Bajaj/ Havells cat No RUGBYNEONFT10WLED860SSYMTOPC/Shakti
Supply and fixing in repair walll/surface mounted 20W LED batten fitting engineering plastic battern with white acrylic cover complete with all accessories internally pre-wired and including fixing the fitting on wall/ceiling with suitable PVC round/square block-02 Nos including connecting up with twin core copper conductor cable with suitable size and all as directed by Engr-in-Charge. Make : CG/wipro/C&S/Shakti cat No SZSLAMX020/Bajaj/Havells/Philips
S & F modular power socket 25A,2 module, 25A plug top, 25A mini MCB 'C' series 3KA including 4 module box with cover plate complete all as specified and directed by EIC. Make: Anchor/Roma/Crabtree SAP code : ACNKCXW253, DCTNCSPA025,ACAGXXW253, ACVPPCWV03,ACTXPIWX03
Material and Labour for Earthing complete with MS plate electrode of size 600 X 600 X 6 mm buried directly and preferably vertically in ground (earth pit not less than 2.25 mtrs deep below ground level ) with top edge of the plate not less than 1.5 Mtrs below ground level, connected to earth strip 25x4 mm galvanized MS strip by means of check nuts, bolts, washers etc all as shown in electrical plate No. 5 of SSR Part-I, connected to Earthing test point including earth work, 1:3:6 type C1 (using 20mm graded stone aggregate) PCC chamber, 1:2:4 type B1 (Using 20mm graded stone aggregate) PCC cover with 8 mm dia steel bars at 100 mm C/C, suitable size of GI pipe for earth lead protection and watering, water funnel etc. complete all as specified and directed.
M & L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire all as specified and directed by EIC.
Supply and fixing in replacement LED 40W Street/building security light fittings with high pressure die cast housing with toughened glass and individual LED with secondary optics and IP66 protection complete all as specified and directed by EIC. Make : CG /Wipro/Philips/Bajaj/ Havells/Benlo/Shakti Cat No SZPCLMX040
S&F GI cable tray perforated type 2mm thick of size 250x50mm to be fixed on any wall (brick/stone) vertically/horizontally including all accessories complete bending,shaping,drilling,welding, cutting & all fixing arrangement complete all as directed.
M&L for cement concrete in 1:2:4 type B1 (using 20mm grade stone aggregate) for road cutting/pole coupling exposed surface and fair and even finished with out using any extra cement etc complete all as specified and directed
Supply and fix in replacement MS arms bracket 30 degree bend, suitable pipe dia for security light & 1.5mtr long for mounting one in nos street light fitting including clamps / nut / bolts & washer to brace the same properly with duly painted in synthetic enamel paint of two coat in silver colour complete all as specified and directed by the Engr-in-Charge.
S&F in repairs of 0.71mm thick aluminium sheet cover, alloy 31000 H4 in ridges, Hips vally gutter including suitable size of revits/nut bolts complete bending, shaping, drilling, cutting notching and all as specified and directed by EIC.
SHREE JAGDISH FURNITURE CO.
SB CONSTRUCTION
Laxmi Sales
M/s Qureshi Construction Co
Bright Construction Co
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .