DIRECTOR, CSIR-IMMT, BHUBANESWAR
CSIR-IMMT, BHUBANESWAR
Creation of a secondary entry point behind Admin block for entry and exit of workers, suppliers and provision of parking (Civil and Electrical) at CSIR-IMMT, Bhubaneswar
2025_CSIR_223918_1
21/2024-25/ESD(C)/IMMT/BBSR
Open Tender
Civil Works
Item Rate
90 days
CSIR-IMMT, BHUBANESWAR
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,000
DIRECTOR, CSIR-IMMT, BHUBANESWAR
₹1.2 L
24 Jan 2025
14 Jan 2025
22 Jan 2025
14 Jan 2025
21 Jan 2025
14 Jan 2025
Amount
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed at CSIR-IMMT dumping yard. All kinds of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form:Columns, Pillars, Piers, Abutments, Posts and Struts
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all completeThermo-Mechanically Treated bars
Brick work with non modular fly ash bricks conforming to IS:12894, class designation 7.5 average compressive strength in foundation and plinth in: :Cement mortar 1:6 (1 cement : 6 coarse sand)
Half brick masonry with non modular fly ash bricks of class designation 7.5 conformingio IS :12894, in in foundation and plinth in : cement mortar 1:4 (1 cement:4 coarse sand )
Half brick masonry with non modular fly ash bricks of class designation 7.5, conformingio IS :12894, in super structure above plinth and upto floor V level. Cement mortar 1 : 4 (1 cement : 4 coarse sand)
Brick work with non modular fly ash bricks conforming to IS:12894, class designation 7.5 average compressive strength in super structure above plinth level up to floor V level in :Cement mortar 1:6 (1 cement : 6 Coarse sand)
Providing and fixing 16 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab Lakha red Area of slab over 0.50 sqm
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete Fixed to openings /wooden frames with rawl plugs screws etc
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes
Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand).Dark shade pigment using ordinary cement (Gicco Make)
Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigment etc.all complete as per the direction of Engineer-in-charge
Providing and fixing 0.50 mm TCT ,high strength (550MPa yeild stress minimum) anti corrosive steel sheet AZ-150 with resin coat on both surfaces to 150 grams per sqm of coating (total both sides).The sheets will have lenghth up to 12.00 mtrs or as desired by EIC.The The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
12 mm cement plaster of mix :1:6 (1 cement : 6 coarse sand)
15 mm cement plaster on rough side of single or half brick wall of mix1:6 (1 cement : 6 coarse sand)
Distempering with 1st quality acrylic distemper (ready mixed) of approved manufacturer, of required shade and colour complete, as per manufacturer's specification.Two or more coats on new work (Asian , UNO)
Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) (Apex Asian)
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm)
Supplying and filling in plinth with local sand under floors including, watering, ramming consolidating and dressing complete.
Providing and fixing of star lock for alluminum window of approved make
Providing and fixing of SS roller for alluminum window of approved make
Providing mechanical means (JCB) for levelling of undulating and cleanning of wild bush,including all the expenditures like diesel,manpower etc.as per direction of EIC.
Providing and laying design mix cement concrete of M-10 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria,, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, curing,including making provision for contraction/expansion, construction & longitudinal joints (10 mm wide x 25 mm deep) by groove cutting machine complete all as per direction of Engineer-in-charge .Cement concrete manufactured in automatic batching plant (RMC plant) i/c transportation to site in transit mixer .Cement Consumption in M-10 is @250Kg/Cum
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq mm (Finolex/ Poly-Cab/RR / KEI make) ISI marked FRLS PVC insulated single core copper conductor cable in surface/ recessed PVC conduit medium class (Kinjal/ AKG /Polycab make) with modular type 5A switch, modular base & cover plate on suitable size modular type metal box (Legrand myrius /schneider clipsal/anchor woods) make incorporated with Neutral & Earth link & earthing the point with 1.5 sq mm FRLS PVC insulated single core copper conductor cable etc as required. Group – C
Supply and fixing 5/6 amps.modular type (1 module)switch on the existing modular plate & switch box including connections etc. as required. (Legrand myrius /schneider clipsal/anchor woods) make
Supply and fixing15/16 amps.modular type (1 module) switch on the existing modular plate & switch box including connections etc. as required. (Legrand myrius /schneider clipsal/anchor woods) make
Supply and fixing 5/6 amps.modular type socket (2 module) on the existing modular plate & switch box including connections etc. as required. (Legrand myrius /schneider clipsal/anchor woods) make
Supply and fixing 5 pin, 15/16 amps.modular (2 module) type socket on the existing modular plate & switch box including connections etc. as required. (Legrand myrius /schneider clipsal/anchor woods) make
Supplying and fixing Modular stepped type electronic fan regulator, 2 module, 120W in the existing modular switch box including connection etc as required. Legrand myrius /schneider clipsal/anchor woods make
Supply and fixing of 6 module, modular base & cover plate & modular type metal box (GI) on surface or in recess etc. as required. (Legrand myrius /schneider clipsal/anchor woods) make
Supplying and fixing of 5amp ceiling rose on the existing junction box/wooden block including connections etc. as required.
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required.
Supplying and drawing 3 x 1.5 sq mm of FRLS PVC (Finolex/ Poly-Cab/RR / KEI make) insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit/ Trunking as required.
Supplying and drawing 3 x 4 sq mm of FRLS PVC (Finolex/ Poly-Cab/RR / KEI make) insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit/ Trunking as required.
Supplying and fixing of 20 mm dia PVC conduit in surface/recessed PVC conduit medium (AKG/Kinjal/Polycab) including cutting the wall & making good the same in case of recessed conduit etc. as required.
Supplying and fixing of 25 mm dia PVC conduit in surface/recessed PVC conduit medium (AKG/Kinjal/Polycab) including cutting the wall & making good the same in case of recessed conduit etc. as required.
Supplying and fixing of single pole 6 to 32 amps rating, 240 volts MCB (C series) of Legrand/Hager/Siemens/ C &S make in the existing MCB DB complete with connections, testing and commsissioning etc. as requried.
Supplying and fixing 63amp, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. Legrand/Hager/Siemens/ C &S make
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC)Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. Suitable for operation on Electronic regulator unit for speed control. (Havells / Crompton energion riviera or similar model as approved by dept)
Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of street light fitting including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required.
Supplying and fixing of 8 way, single pole and neutral, sheet steel,double door MCB distribution board, 240 volts, on surface/recess, complete with terminal blocks, duly prewired with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar, hinged gland plate, interconnections,. including painting, earthing etc. as rquired. Legrand/Hager/Siemens/ C &S make
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supply & laying 25mm x 5 mm GI strip at 0.5 mtr below ground as strip earth electrode including connection with GI nut, bolt, spring washer etc. as required.
Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required.
Supplying and making end termination with brass compression gland and aluminium lugs for 4 core x 10sq mm size of PVC insulated armoured and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV grade as required.
Supplying and making end termination with brass compression gland and aluminium lugs for 4 core x 25 sq mm size of PVC insulated armoured and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV grade as required.
Supplying and laying of 63 mm dia (OD-63 mm & ID-51 mm nominal) size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
Supplying and laying of one number PVC / XLPE insulated armoured and PVC sheathed AL. conductor power cable of 1.1 KV grade POLYCAB / Finolex/ KEI make armoured cable as approved by dept. Engg. of 4 core x 10 sq mm size in the open duct / existing trench /pipe etc. as required.
Supplying and laying of one number PVC / XLPE insulated armoured and PVC sheathed AL. conductor power cable of 1.1 KV grade POLYCAB / Finolex/ KEI make armoured cable as approved by dept. Engg. of 4 core x 25 sq mm size in the open duct / existing trench /pipe etc. as required.
Street Light Octagonal Pole with Foundation Type Base Plate & Foundation Bolts (Dimensions for pole as Top Diameter 70 mm, Bottom Diameter 155 mm, Section Length- 9000 mm,Thickness-3 mm, Foundation Type Base Plate (250X250X16 mm), Foundation Bolts (M24 X 700/750 MM-4Nos) with Round shape Lantern ring for provision of mounting of 4 nos of Flood Lights including cement concrete foundation complete as required as per foundation drawing approved by engineer in charge. The Octagonal Poles shall be in single section. There shall not be any circumferential weld joint. The octagonal Poles shall have door of approximate 500 mm length at the elevation of 500 mm from the Base plate. The door shall be vandal resistance and shall be weather proof to ensure safety of inside connections. Bakelite sheet with four nos 6A SP MCB, C-series and 32 amp four pole stud type connector inside the pole at door opening for cable connection.The door shall be flush with the exterior surface and shall have suitable locking arrangement. The pole shall be adequately strengthened at the location of the door to compensate for the loss in section.
S/I/T/C of outdoor type Street Light Timer Box (outdoor type, double door, 600mm * 500mm * 300mm size , made out of metallic sheet steel with powder coating ) alongwith Digital type programmable Time switch(2 C/O) , Two no 40 AMP (AC3) 3P power contactor (MNX40), FP 63amp MCB C-series -1 no as incomer, 32amp FP MCB C-series - 2 nos as outgoing. Auto/manual toggle switch, one no LED ON Indicator, Neutral bar & complete wiring etc as per drawing approved by engineer in charge to be mounted on a metalic structure made out of required size MS angle & frame / Civil pedastal work etc complete as required. (MCB of Legrand/Hager/Siemens/ C &S make. Timer & Contactor of L & T/ GEC/ Seimens/ C & S make)
Supplying and laying of 3C x 1.5 sqmm PVC insulated and PVC covered (Finolex/ Poly-Cab/RR / KEI make) copper cable in the existing octagonal pole for connection of flood light etc as required.
Supply, installation, testing and commissioning of 200 watt LED flood light, minimum 135 lumen / watt (Philips / Lighting Technology/ Passolite as approved by Engineer in charge) with all accessories on existing tubular pole etc. as required.
Supplying & installation, testing and commissioning of prewired baten fitting/LED channel (box type) suitable for two numbers LED tube light of (Philips / Lighting Technology/ Passolite as approved by Engineer in charge) with all accessories and 2 nos 2000 lumen led tube etc. directly on wall including connections with 1.5 sq mm PVC insulated, copper conductor, single core cable etc.as required.
Supply, installation, testing and commissioning of prewired street light LED fitting of 65watt, minimum 100lumen/watt (Philips / Lighting Technology/ Passolite as approved by Engineer in charge ) with all accessories etc. including connections with 1.5 sq mm PVC insulated, copper conductor etc. as required.
Supply, installation, testing and commissioning of prewired street light LED fitting of 200watt, minimum 140lumen/watt (Philips BRP 505 LED 280 / Lighting Technology/ Passolite as approved by Engineer in charge ) with all accessories etc. including connections with 1.5 sq mm PVC insulated, copper conductor etc. as required.
Supplying & installation, testing and commissioning of prewired recessed mounting downlighter square fitting, 2ft x 2 ft of 30watt, minimum 100lumen/watt , (Philips / Lighting Technology / Passolite as approved by Engineer in charge) with all accessories etc. including connections with 1.5 sq mm PVC insulated, copper conductor etc.as required.
Sarthak Das (BID ID -810868)
BIMAL CHANDRA PADHI (BID ID -810791)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .