Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.5 LAccepted-AOC RZ H 5 NANDA BLOCK MAHAVIR ENCLAVE PART 1 PAL AM SOUTH WEST DELHI DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | L1 | Accepted-AOC AWARDED | |
| 2 | L2₹37.9 L+₹3.3 L (9.68%)Rejected-Finance | L2 | Rejected-Finance Rejected | |
| 3 | L3₹39.3 L+₹4.7 L (13.6%)Rejected-Finance | L3 | Rejected-Finance Rejected | |
| 4 | L4₹44.1 L+₹9.5 L (27.4%)Rejected-Finance | L4 | Rejected-Finance Rejected | |
| 5 | L5₹44.8 L+₹10.3 L (29.7%)Rejected-Finance RZ 55 1ST FLOOR MOHAN NAGAR PANKHA ROAD NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L5 | Rejected-Finance Rejected |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
30 May 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Subroto Park
GE (AF) Subroto Park c o 56 APO
EXECUTION OF CERTAIN SANCTIONED WORKS UNDER THE AREA OF AGE B/R-I, AGE B/RII AGE E/MI OF GE AF SUBROTO PARK
2023_MES_592324_1
GE/SP/ TOKEN-19/2023-24
Open Tender
Civil Works
Item Rate
180 days
Subroto Park Delhi Cantt
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE (AF) Subroto Park
₹90,000
Yes
30 Jun 2023
29 Apr 2023
6 Jun 2023
29 Apr 2023
30 May 2023
13 May 2023
Amount
M & L for complete removal of existing roof treatment (Mud puska, Cement Tiles or Old APP Roof treatment etc) including bedding layer in cement mortar/Mud and disposed from MoD land complete all as specified and directed by Engineer-in-charge.
M&L PCC 1:2:4 type B1 using 20mm graded aggregate mixed with 3.00% liquid water proofing compound of weight of cement laid 25 mm thickness as in padding over roof slabs for providing proper slope to the concrete padding, surface finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-charge. Note : Liquid WPC shall be measured and paid separately.
M&L 15 mm thick screed bed or bedding layer of cement mortar 1:4 with 3.00% liquid water proofing compound of weight of cement complete all as specified and directed by Engineer-in-Charge. Note : Liquid WPC shall be measured and paid separately.
Supply only Liquid water proofing compound complete all as specified and as directed.
M&L priming surface and applying normal treatment (for moderate conditions) using glass fibre bitumen felt,grade 2 as per specifed complete all as specified and directed by Engineer-in-charge.
M&L for five layer prefabricated atactic polypropylene polymer (APP) modified 3 mm thick membrane ( weight not less 3 kg/sqm) reinforced with 160 gms polester non-woven fabric with scratched tool before finishing roof surface. When the concrete surface is still green, 10 mm thick 1:4 cement plaster shall be laid the roof surface shall be throughly wire brushed washed dried up and cleaned of all foreign matter and dust prior to the application of primer on the dried surface one coat of approved bituminous primer, having density in the range of 0.87 to 0.89 / kg at 25 dgree and viscositing of 70 to 160 CPS manufactured by the same manufacturer @ 0.40 litres/sqm shall be applied. APP membrane shall be laid on primed surface tourch application mehtod after allowing 24 hours of primer to dry. Laying of APP membrane shall be commneced at the lowest level and worked upto the crest.APP membrane will normally be laid in length at right angle to the direction of slope. The overlaps shall be of minimum 100 mm on longitudinal direction and 150mm on the transverse direction. All overlaps shall be bonded with bitumen primer and levelled by the heating the overlaps with brutane tourch. This treatment shall be done by the approved authorised applicator. Guarantee of treatment shal be for 10 years. Thereafter APP membrane shall be painting with two coat of water proofing paint with aluminium finish. (ii) Independent testing of membrane for the approval technical parameters specified hereinafter shall be carried out the approved laboratories like National test house any other Govt approved laboratory having facilities for the testing of membrane.
M&L for 2 coat of water proof aluminium paint incl preparation of newly or previously untreated surfaces of any description, over 10cm width or girth, not otherwise described complete all as specified and directed by Engineer-in-charge
Dismantling water tank and removing to store exeeding 500 but n.exc 1000 ltrs complete all as specifed and directed.
S&F for rotational moulded polyethylene water storage tanks triple layers (white colour) of 1000 ltrs capacity (cylindrical vertical with closed threaded top) hoisted and fixed in position including 20mm dia HD polythene float (ball) and epoxy coated aluminium rod (fly nut) screwed for iron pipe or brass ferrule complete all as specifed and directed.
Dismantling water tanks capacity exc 250 ltrs and n. exc. 500 ltrs & removing to store complete all as specified and as directed by the Engineer-in-Charge.
S&F for rotational moulded polyethylene water storage tanks triple layers (white colour) of 500 ltrs capacity (cylindrical vertical with closed threaded top) hoisted and fixed in position including 20mm dia HD polythene float (ball) and epoxy coated aluminium rod (fly nut) screwed for iron pipe or brass ferrule complete all as specifed and directed.
S&F in repair Gun-metal, globe or gate valves, bore dia of pipe 20mmwith iron wheel head, screwed both ends for iron pipe and fixed
M&L for complete removing existing treatment old/new surface of wall and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance 1st quality exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces including change of existing colour if required complete all as specified and as directed by Engineer-in-Charge. Note:- (a) Work will executed upto 1st floor. (b) The rate is inclusive for scaffolding or reqd nessesary arrangement for multistory bldg painting.
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L for glazed ceramic coloured tiles of size 350 x 250 x 7mm/450 x 350 x 7mm thick over and ncluding 10 mm thick rendering in cement mortar 1:4 as in backing coat for tiles on vertical surfaces,set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specifed and directed.
Taking down cement plaster on brick or stone wall etc incl raking out joints hacking for key scrubbing down with water complete all as specifed and directed.
M&L for 15 mm thick rendering in cement mortar 1:4 or fair faces of brick or cement concrete surfaces finished even and smooth without using extra cement complete all as specifed and directed.
M&L for 5 mm thick rendering in cement mortar 1:3 on fair faces of ceiling or cement concrete surfaces finished even and smooth without using extra cement complete all as specifed and directed.
M&L for preparation of old decorated steel surfaces any description,over 10cm in width or girth, not otherwise describedand applying one coat of synthetic enamel paint over 10 cm in width or girth complete all as per specified and directed.
Dismantling plain corrugated/plain steel sheeting any gauage thick ness including Nainital and similar pattern complete all as specifed and directed.
S&F for 2mm thick fibre glass reinforced translucent corrugated sheeting with two corrugated side lap complete all as specifed and directed.
Surface excavation n. exc. 30 cm deep averaging 15 cm & getting out in soft/loose soil as per instuction by Engr-in-Charge.
M&L for 75mm thk cement concrete 1:4:8 type D2 (using 40 mm graded stone aggregate) as in sub base for floors finishes.
M&L for sand filling under floors or in foundations including watering and consolidation all as specified and directed.
M & L for rubber moulded glossy finished Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade with grey cement and pigment laid and bedded on sand cushioning complete all as specified and directed.
M&L for rubber moulded glossy finished Chequered cement concrete tiles with white cement and pigment 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry incl 15mm thick Screed bed or bedding layer of cement mortar 1:4 for for laying tiles all as specified and directed.
Excavating in trenches n.exc 1.5m wide and n.exc 1.5m in depth for fdn etc in any type of soil. complete all as specified and directed.
M&L cement concrete type C2 1:3:6 (using 40mm gde stone agg) as in sub base of drains etc. complete all as specified and directed.
Removing of excavated soil/mtrl n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point.
Returning filling in including spereeding, levelling, watering and wall ramming in layers n. exc 25cm thick.
M&L for brick work with sub class ‘B’ bricks old size straight or curved on plan exceeding 6m mean radius built in cement mortar 1:4 all as specified.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, mounds, mitred/stopped end etc.
M&L for PCC 1:2:4 type B-1 using 20 mm graded aggregate as in bed blocks, bed blocks of hold fasts, coping, PCC cill etc.
M&L for Cast iron work grade FG 150, unmachined, in brackets, gully traps, gratings, railing, frames, manhole covers and similar articles including dismantling of old CI cover complete all as specified.
S&F of Stainless Steel 304 series board of size 4'x3' written both side . Board Frame made of SS 304 series 16 gauge 25mm wide and one pipe to be fixed in center . The board shall be sheathed both side with 4mm thick ACP Sheet with reflective tape of blue color high intensity plastic (HIP) 3M on both side , letter shall be written in white color the size is as required, approved by Engr-in-Charge including 02 nos vertical SS post 304 series 50mm dia of pipe, height of 8.5 ft and top mouth closed with SS cap complete all as specified and directed .
S&F for Anodised aluminium frame (minimum 50 micron powder coating) for doors, windows, ventilators or in partitions with one or more rebates with without sash bar including jointing, cleat glazing clips aluminum mongry etc fixing of sheet glass and particle board complete all as specified.
S&F 5.5mm thick plain glass ordinary quality and glazing, suare exc 0.50 sqm in each pane as in doors etc
S& F 9mm thick prelaminated particle board, interior grade, prelaminated on both sides with decorative choice lamination all as specified
S&F for powder coated aluminium doors shutters,( thickness of powder coating not less than 50 micron) alumonium section weighing 0.75 kg/m incl necessary joining cleats, glazing clips, rubber neoprene packing , handels 2 Nos in each door , hinges, anodised aluminium snap beading screws etc. complete all aspecified and directed by engr-In-Charge.
S&F Aluminium (extruded section) body door closer hydraulically regulated, designation No.3, universal type, suitable for door shutter of 851 to 1000mm in width all as specified
S&F for Brass Mortice lock, vertical/sliding type, size 100mm, 4 Levers complete
M&L for providing and applying 5mm thick on average POP (plaster of peris) punning on wall/ceiling over plastered surface/concrete surface to prepare the surface even and smooth, complete all as specified and directed by Engr in Charge.
M&L for preparation of old plastered or unplastered surfaces on walls and applying two coat of approved shade of plastic emulsion paint over a coat of primer complete all as specified and directed by Enger-in-Charge
M&L for POP false ceiling (Shriram/Birla make) with ISI grade GI framing of cross section 1"X1.5" cross, main 2"x0.5 and angle 1"x1" section with first quality ss chicken mesh of 0.71 mm dia with size of mesh 20x20mm fixed with tinned tacks of wire staples including all hardware i.e. screws, hangers etc with all hangings accessories cut out to made for lighting, fixture and AC griils and including preparation of surface and applying two coats of distemper oil emulsion on walls/ceiling over a coat of primer incl 3mm thick wall care putty on walls etc complete and dismentling all and removing building materials etc included in the rates, loading, unloading and stacking at the destination complete all as specified and directed by Engineer-in-Charge.
M&L Virified Ceramic light shade tiles 9 to 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match flooring( in any pattern) and jointed with neat cement slurry over 15 mm thick cement screed in CM 1:6 and pointed with coloured cement matching with surfaces of tiles as in floor with skirting dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises.complete all as specified and as directed by Engr-In-Charge.
All as above item No-45 but as on vertical surface of wall such as skirting/dado incl 10mm thick cement plaster (1:4) as in backing coat of tiles complete all as specified and directed.
Material and labour for false ceilings using GI snap grid system with roll-formed out of hot dip galvanised steel caping (powder coated) main runner 38 x 24 mm , cross Tee 29 x 24 mm and wall angle 24 x 24 mm members suspended with 4mm dia GI wire, carry maximum load up to 8.10 Kg/Sqm with 4mm thick designer ceiling board , pre painted Gypsum Board 12mm thick in ceiling fixed with screw as per manufacturers instructions size 595 x 595mmx 4mm thick any texture (Lake and Hill, oceaniccascade or Electra) as approved by GE all as per , Everest Ceiling grid system 'Regular T-2430' or its equivalent make of "'Ramco, Charminar/Armstrong'' at any height including dismantling complete all as specified and as directed by Engr-In-Charge.
M&L for brick work with subclass 'B' bricks, straight or curved on plan exc 6 M mean radius built in CM 1:6 complete all as specified and directed by Engr In Charge.
M&L for rendering CM (1:6) 10 mm thick on other than fair faces of brick work or concrete surfaces etc including finished even and smooth without using extra cement up to four storey height bldg complete all as specified and directed by Engr In Charge.
S & F for framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; cooler stand, framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and directed by Engr In Charge.
S&F pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/clading to wall, fixed with self tapping screws as specification complete all as specified and directed by Engr In Charge.
M&L plain cement concrete 1::4:8 type D-2 mm graded crushed stone aggregate) as in foundation filling and mas concrete.
M&L for Non - skid Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not xceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in cement mortar (1:4) over type D2,1:4:8 as in sub base complete all as specified and directed by Engr In Charge.
S&F precast machine pressed PCC interlocking paver block of 80 mm thickness, M-40 grade of any shape and size confirming to IS -15658-2006 with grey cement and pigment as approved and 100mm thick plain cement concrete, type D-2, 1:4:8, (using 40mm graded stone aggregate) as in sub base flooring, surface finished even and rough to receive floor topping including sand cusion and dismentling complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new plastered surfaces of walls, and applying two coats of distemper oil emulsion over a coat of primer incl 3mm thick elastomeric wall care putty on walls complete and specified and as directed by engr-in -charge.
M&L for preparation of new previously untreated wall surfaces and applying two coats of exterior Apex/weather coat over 3mm thick wall care putty up to four storey height building complete and all as specified and directed by engr-in-charge.
S&F for 15mm bore steel water tubing medium grade , galvanized ISI marked with all fittings fixed to wall & ceiling or laid in floors complete all as specified and directed by Engineer-in-charge.
All as per item no 57 above but 20mm bore
S&F for PVC SWR bends 110 mm complete all as specified and directed by Engr In Charge.
S&F PVC SWR bends 75 mm complete all as specified and directed by Engr In Charge.
S&F for PVC (SWR) pipes 110 mm single socketed, in any length with solvent cement joints fixed to walls/laid in floors incl stack clamps of stainless steel with bolts & nuts etc complete all as specified and directed by Engr In Charge.
All as per item no 61 above But 75 mm dia..
S & F in repairs for 125mm dia Steelness steel grating doom with waste hole for waste pipe ( minimum weight 40 gram) complete all as specified and directed by Engr In Charge.
S&F in repair gun metal globe balve ot gate valve with mild steel iron wheel head, screwed both ends for iron pipe & fifed for 20 mm bore complete all as specified and directed by Engr In Charge.
S/F in repairs 15 mm Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed fancy type, chromium plated with long shank and cup (concealed type)all as per specified and directed by Engr-in-Charge.
S & F in repairs 15mm CP bib tap fancy type copper alloy with crutch or butterfly handle , screwed down, screwed for iron pipe etc complete all as specified and directed by Engr In Charge.
S & F in repair 15mm dia brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed
M & L in repairs for 15 mm dia Fancy type Chromium plated Angle valves, cast copper alloy screwed down high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed by Engr In Charge.
S&F in repairs CP tubular Towel rail , 20 mm dia, D Type 600mm long between flanges brass chromium plated with screws and cleats, (Minimum weight 190 gms) complete all as specified and directed by Engr In Charge.
S&F 15mm dia PVC Connection 450 mm long with nuts complete all as specified and directed by Engr In Charge.
S&F in repairs vitreous china wash hand basin of size 550mm x 400mm white, flat back including angle iron brackets with two coats of synthetic enamel paints including PVC waste pipe of 32mm dia of suitable length, PVC connection of 15mm dia & 450mm long with PTMT nuts, and 32mm dia brass waste fitting with padestal complete all as specified and directed by Engr In Charge.
M & L for 75 mm thick PCC 1:3:6 type C2 as in Plinth Protection using 40 mm stone aggregate including making joints & filling with sand bitumen mastic as per complete all as specified and directed by Engr In Charge.
M &l for removing building materials etc. (other than spoil payable under items 03028 to 03031 in Section-3—Earthwork) to a distance of 15km, beyond the lead included in the rates, including loading, unloading and stacking at the destination complete all as specified and directed by Engineer-in-Charge.
M&L for providing PCC 1:2:4tyoe B-1 (using 20 mm graded stone agg)as in manhole covers set in cement motor 1:6 all as specified and directed including necessary form works and moulds all as specified.
S & F Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) including providing and fixing plugs, bedding urinal aginst wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screw, pointing around urinal back in cement, fixing brackets, waste pipe with coupling, gratting and Union for discharge pipe.
M&L Rendering 15mm thick in CM 1:6 on other than fair faces of brick work or concrete surfaces of walls, finished even and smooth ( without using extra cement) including taking down cement or cement lime plaster any description on any walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified
M&L for preparation of new plastered surfaces of walls, and applying two coats of distemper oil emulsion over a coat of primer incl 3mm thick elastomeric wall care putty on walls complete all as spd.
M&L for prepration of old plastered or unplastered surfaces of walls and applying two coat of approved shade of oil emulsion distemper, including repairing of pot holes and cracks with putty,complete all as specified and directed by Engr-in-Charge.
Taking down earthing strip insulatopr removing materials to store for keeping in safe costudy or for taking credit (credit for above items should be made as per conditioned separately) and making good distrubed surface of walls, floors etc complete all as specified and direced by Engineer-In-Charge.
S & F replacement of earthing strip insulator for electric installation of size 25mm x 3mm with flame retardance breaking current capacity is 5ka complete all as specified and directed by Engineer-In- Charge.
M & L in replacement of Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 2mm dia galvanised iron or steel wire complete all as specified and direced by Engineer-In-Charge.
Supply and fix double pole and neutral enclosure 240 volt 20 Amps with a two pin and earth plug and socket complete with one single pole MCB complete all as specified and directed by Engineer-In- Charge.
M & L for in replacement submain wiring with two run of 4.0 sqmm single core PVC insulated but unsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts grade IS:694 marked and one run of 4.0 sqmm PVC insulated but unsheathed FRLS cable for earth continuty conductordrawn through and under suitable size of rigid non metallic PVC conduit , medium grade, ISI marked ( not less than 20 mm dia) complete with all acessories and fittings all laid/fixed concealed in wall/ceiling or surface in wall and surface conduit on ceiling, and also include the specified runs of specified size earth continuity conductor of similar type cable complete all as specified - 2 Runs of 4.0 Sqmm single core and one run of 4.0 sqmm single core cable.( Note : considered for AC point)
Supply & laying and testing cable XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 Sqmm 3.5 core and including PVC conduit size of suitable size according to cable including conduit fittings and accessories conealed in wall / ceiling or surface conduit wiring on ceiling/ wall terminated in flush metal box complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement of fixed thermal and fixed magnetic settings, 4 pole MCCB 100 Amps, 50 hz, 415 Volts with rupturing capacity 36 KA complete all as specified and directed by Engr-in-charge.
Supply & fixing in replacement of MCB distribution board with Bus Bar 200 A neutral link, earth bar made out of CRA mild steel surface mounting TPN 8 way 230 Volt double door type regal gray horizontal type complete all as specified and directed by Engr-in-charge.
Supply and fixing 415V 10KA 'C' curve, TPN 40 to 100 Amp miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning.
S&F MCB SP 5 to 32 Amps 10 KA, 240 volt, 'C' series all as specified and directed by Engr-in-charge.
Supply and fixing MS cable tray Mild steel of size 3MM thickness, rectabgular with polished finishing and Galvanised coating. All accessories including coupiers mounting accessories are required of same finish as per site requirement complete all as specified and directed.
M&L for in replacement submain wiring with two run of 4 sqmm single core PVC insulated but unsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts IS 694 marked and one run of 4.0 sqmm PVC insulated but unsheathed FRLS cable for earth continuty conductor drawn through and under suitable size of rigid non metallic PVC conduit, medium grade, ISI marked (not less than 20mm dia) complete with all accessories and fittings all laid/ fixed concealed in wall / ceilling or surface in wall and surface conduit on ceiling and also include the specified runs of specified size earth continuity conductor of similar type cable complete all as specified and directed 2 Runs of 4.0 Sqmm single core and one run of 4.0 sqmm single core cable
M&L for point wiring with single core of FRLS PVC insulated unsheathed ISI marked 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm drawing through in and including PVC conduit size of not less than 20mm including conduit fittings and acessories concealed in wall / ceiling or surface conduit wiring on ceiling /wall terminated in flush metal box alongwith outer cover plate for mounting modular switch, socket and electronic regulator along with provn of earth wire of PVC insulated, unseathed, 1100 V grade cable multi stranded FRLS ISI marked copper conductor of size 1.5 Sq mm cable for Independent bd one 3 pin 15 Amps socket outlet including S/C 1.5 Sq mm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FR LS cable for continuous earth wire connected to gang box of required size for one light/fan/bell point controlled by one switch.
All as per item No 93 above but 2.5 Sq mm cable for Independent bd one 3 pin 15 Amps socket outlet including S/C 2.5 Sq mm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FR LS cable for continuous earth wire required size all as specified and directed by Engineer-in-Charge.
All as per item No 93 above but for one 3 pin 5 amps socket outlet on indipendent board with other switchs.
S&F switch piano, flush type single pole, one way, 5 Amps, 240 volts all as specified and directed at site.
S&F socket 16 Amps, 2 in 1, flush type all as specified and directed at site.
Supply and fix double pole and neutral enclosure, 240 volt 20 Amps with a two pin and earth plug and socket complete with one single pole MCB complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement MCB distribution board, earth bar made out of CRCA mild steel sheet surface mounting SPN 2 way 230 volts double door type regal gray horizontal type complete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid seperately.
Supply and fixing in replacement MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCA mild steel sheet surface mounting SPN 4 way 230 volts double door type regal gray horizontal type complete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid seperately.
S&F MCB SP 6 to 32 Amps 10 KA, 240 volt 'C' Series all as specified and directed by engineer-in-charge.
S&F MCB SPN 32 Amps 10 KA, 240 volt 50 Hz 'C' Series all as specified and directed by engineer-in-charge.
M & L Design, development, supply commissioning & testing EHCC certified ground tubular effective Tripot type chemical earthing system ( CPRI tested for 15 KA current capacity for LT line) highly anticorrosive long life electrode with and including adequate protective coating to withstand severe wear conditions in the earth pit of the standard size comprising of 25mm x 3mtr long copper rod as primary conductor and hollow pure Copper tube of dia 50mm x 3mtrs long as secondary conductor to install with suitable connection terminal coforming of IS 3043: 1987 specification, highly conductive packing material to be filled in earth pits for providing uniform, low resistivity anticorrosive, hygroscopic medium around the earth system for improving the efficiency of current dissipation 02 Bags / 60 Kgs minimum or sufficient quantities required as per site complete including FRP earthing pit clause suitable cover, material and labour including testing after completipon and result should be less than one Ohm complete all as specified and as directed by Engineer-in Charge.
M&L for Earth continuity copper conductor or main earthing lead of size 20x3mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to pole or any other indicated situation for loop earthing etc complete all as specified and directed by Engineer-in-charge.
Boring holes 2 m deep and additional under-reaming as per site requirement upto 5 mtr and above depth in soil for under-reamed piles and getting out and disposal of spoil to a distance of n exc.50 m all as specified and directed by Engineer-in-Charge.
S& F in replacement of earthing strip insulator, for electric installlationg of size 25 mm x 3mm with flame retardance, breaking current capacity is 5ka complete all as specified and directed by Engineer-in-Charge.
Taking down carefully copper/aluiminium point wiring light, fan, light fitting socket or power complete such as switches, ceiling roses, pendents, regulators sockets etc removing material to store for keeping in safe custody or for taking credit for above items should be made as per conditioned seperately) and making good disturned surface of walls, floors etc complete all as specified and directed.
M&L for point wiring with S/C of FRLS PVC insulated unsheathed IS-694 marked 1100 V grade cable multi stranded copper conductor of size 1.5 Sqmm drawing through in and including PVC conduit size of not less than 20mm including conduit fittings and accessores concelared in wall/ ceiling or surface conduit terminated in sheet metal box along with provn of earth wire of PVC insulated unseathed 1100V grade cable multi stranded FRLS IS-694 marked copper conductor of size 1.5 sqmm all as specified and directed by Engr In charge.
M&L for sub main wiring with two single core FRLS insulated, stranded, unsheathed cable copper conductor of size 04 Sqmm drawing through & including Non metallic PVC conduit concealed in wall including earth continuity conductor of size 04 Sqmm PVC insulated unsheathed stranded copper conductor in wall including earth dolly to be drawn in concealed PVC conduit including connecting to maijnh board complete.
All as per item 109 above but for one C/fan/Exhaust fan point controlled by one switch one way.
All as per item 109 above but 3 pin 5 Amps socket outlet on indipendent board with other switch.
All as per item 109 above but 3 pin 5 Amps socket same board with other switch.
S&F modular switch 1 way 6A, modules suitable for 240 volt AC complete all as specified and directed by Engr-in-charge.
S&F modular switch 1 way 6A, 2/3 pin combined 2 modules, suitable for 240 volt AC complete all as specified and directed by Engr-in-charge.
Supply and fix white cover plate with frame 3 module complete all as specified and directed.
Supply and fix Metal flush box 3 module complete all as specified and directed.
S&F modular white cover plate with frame 6 modular complete all as specified and directed.
S&F flush mounting box 6 modular complete all as specified and directed.
Supply and fixing in replacement ceiling roses, surface bakelite 65x50mm , 3 terminals 3 phases PVC/ Polycarbonate isolated body all as specified and directed.
Supply and fixing wall mounted LED batten extruded aluminium heat shrink provided for efficient heat dissipation and integrated electronic driver ,20 watt LED fitting, 4000K , 230 Volts, diffused optics ,etc complete with all accessories , connecting up with twin core twisted flexible copper conductor cable from ceiling rose to fitting, and testing complete all as specified and directed by the Engineer- In- Charge.
Supply and fixing wall mounted LED batten extruded aluminium heat shrink provided for efficient heat dissipation and integrated electronic driver ,10 watt LED fitting, 4000K , 230 Volts, diffused optics ,etc complete with all accessories , connecting up with twin core twisted flexible copper conductor cable from ceiling rose to fitting, and testing complete all as specified and directed by the Engineer- In- Charge.
S&F Exhaust fan 200mm sweep 230 Volt, 1400 RPM including necessary fixing arrangement for proper fixing in wall as per site requirement complete all as specified and directed.
Supply and fixing ceiling roses, surface bakelite 65x50mm ,3 terminals 3 phase, PVC/Polycarbonate, isolated body all as specified and directed at site.
S&F wall mounting fan 450 mm sweep 230 Volt, rated motor speed not more than 1400 RPM, pull cord type 3 step regulator, pull cord type oscillation and mechanism for upwad and downword adjustment including necessary fixing arrangement for proper fixing in wall as per site requirement complete all as specified.
M & L for in replacement submain wiring with two run of 6.0 sqmm single core PVC insulated but unsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts grade IS:694 marked and one run of 6.0 sqmm PVC insulated but unsheathed FRLS cable for earth continuty conductordrawn through and under suitable size of rigid non metallic PVC conduit , medium grade, ISI marked ( not less than 20 mm dia) complete with all acessories and fittings all laid/fixed concealed in wall/ceiling or surface in wall and surface conduit on ceiling, and also include the specified runs of specified size earth continuity conductor of similar type cable complete all as specified - 2 Runs of 6.0 Sqmm single core and one run of 6.0 sqmm single core cable all as specified and directed by engineer-in-charge.
M & L for in replacement submain wiring with two run of 4.0 sqmm single core PVC insulated but unsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts grade IS:694 marked and one run of 4.0 sqmm PVC insulated but unsheathed FRLS cable for earth continuty conductordrawn through and under suitable size of rigid non metallic PVC conduit , medium grade, ISI marked ( not less than 20 mm dia) complete with all acessories and fittings all laid/fixed concealed in wall/ceiling or surface in wall and surface conduit on ceiling, and also include the specified runs of specified size earth continuity conductor of similar type cable complete all as specified - 2 Runs of 4 Sqmm single core and one run of 4 sqmm single core cable all as specified and directed by engineer-in-charge.
S&F MCB SP 6 to 32 Amps 10 KA, 240 volt 'C' Series all as specified and directed by engineer-in-charge.
Supply and fixing SPN 40 to 63 amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning all as specified and directed by engineer-in-charge.
Supply and fixing MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCA mild steel sheet surface mounting SPN 8 way 230 volts double door type regal gray horizontal type complete all as specified and as directed by Engineer-in-Charge. (Note :- MCB shall be measured and paid seperately.)
Supply and fixing MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCA mild steel sheet surface mounting SPN 12 way 230 volts double door type regal gray horizontal type complete all as specified and as directed by Engineer-in-Charge. (Note :- MCB shall be measured and paid seperately.)
GIR RAJ BUILDERS
J D ENTERPRISES
Mahesh Enterprises
Ashish Sehgal and Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .