Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.1 LAccepted-AOC | L1 | Accepted-AOC Accepted being lowest on 29 May 2021. Alloted new CA No. GE FRD-15/2021-22 | |
| 2 | L2₹27.2 L+₹4.2 L (18.0%)Rejected-Finance | L2 | Rejected-Finance Rejected |
Tender Value
₹22 L
EMD Value
₹44,000
Closing Date
7 May 2021, 10:00 amClosed
GE Faridkot
Garrison Engineer, Faridkot-151203 Punjab 01639-264982
Balance work for Special repairs to Bldg No. P-639 (C and D) of G Med Regt and certain Revenue Works under AGE B/R (M) at Faridkot Mil Stn
2021_MES_425069_2
GE FRD-77/2020-21
Open Tender
Civil Works
Item Rate
180 days
Faridkot Mil Stn
Class E Category a i
8 documents required · 8 mandatory
₹500
GE Faridkot
₹44,000
Yes
3 Jun 2021
9 Apr 2021
10 May 2021
9 Apr 2021
7 May 2021
23 Apr 2021
Amount
Taking down wooden/steel chowkhats or frames with shutters (without taking off shutters from the frames) not exceeding 1.50 Sqm each including cutting holes of appropriate size in brick walls/ concrete surfaces for insertion of PCC block of hold fasts complete all as specified & directed by Engineer-in- charge.
Taking down shutters of any description wooden/aluminium exc 1 sqm and n. exc 2 sqm each and refixing in the same opening after easing, adjusting and replacement of minor nails etc complete all as specified and directed by Engineer in Charge.
M&L for pressed steel frames(1.25mm thick) for door of size 105mm x 60mm with one or more rebates including necessary fixing arrangement such as lugs, hinges, lock strike plate etc complete all as specified and directed by Engineer-in-Charge. Note : Hinges will be measured & paid separately under relevant item of BOQ.
M&L for framed work such as grills,gratings, cooler stand, ladders etc.. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; shouldered with steel windows / ventilators frame; railings; framework of water tanks and similar work conforming to (Fe.290.Gde-E-165) complete all as specified and directed by Engineer-in-Charge.
S&F 35mm thick, factory made plain framed panelled (any number of panels) shutters of 2nd class hard wood with lock rail and panel inserts of 9mm thick BWP commercial ply or 12mm thick veneered particle board flat pressed three layered conforming to IS-3097 exterior grade-I type- I duly ISI marked general purpose commercial veneered on both side bonded with (BWR) type phenol formaldeyde synthetic resin-adhesive, the size of rails and styles as per IS-1003 Part-I, Kiln seasoned and chemically pressure treated complete all as specified & directed by Engineer-in-Charge. Note :- The species of timber shall be Hollock/Bonsum
S&F 35mm thick, glazed and skeleton shutter of 2nd class hard wood open rebated and prepared to receive glass, gauge etc, without sash bars, edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass, etc. Sizes of members as specified in SSR Part-I, Section 8.24 (a) and fitted to chowkhats complete all as specified and directed by Engineer-in-Charge. Note :- The species of timber shall be Hollock/Bonsom.
S&F pressed steel rectangular frames for built in cupboard doors, made out of mild steel sheet 1.25mm thick with girth of frame 185mm including necessary MS rawl plugs and fixing 75mm long butt hinges medium weight cold rolled mild steel etc including two coats of synthetic enamel paint over a shop coat of zinc chromate primer complete all as specified and directed by Engineer-in-Charge.
S&F pressed steel door shutters including stiffeners made out of mild steel sheet 1.25mm thick cut to size, holes punched and welded seams including bending or turning up all around, mitered angle, one No. Of locking arrangement etc and applying two coats of synthetic enamel paint over a shop coat of zinc chromate primer all as per Godrej pattern complete all as specified and directed by Engineer-in-Charge. Note : (i) Measurement of door shutter shallbe taken as exact size of cup board opening (excluding frame and folded / turned up portion). (ii) Stiffeners of 150mm girth and height equal to height of shutter made to shape as directed by Engineer-in-Charge shall be provided to each leaf. Cost of these stiffeners shall be deemed to be included in the unit rate quoted for door shutters and no extra measurement / payment shall be made for the same)
M & L 18mm thick block board, grade 2 quality, interior grade,decorative type with decorative face veneer on one face,fixed with screws to timber frame work with 6mm thick teak wood lipping fixed with nails as in cup board shutters, shelves complete all as specified & directed by Engineer-in- charge.
S&F 40mm dia, cupboard knobs fixed with nut, screw and washer of brass, polished complete all as specified and directed by Engineer in Charge.
S & F 150mm long Aluminum hasp & staple, safety type, with mild steel hinge pin including bolt to hinge plate fixed with screws complete all as specified and directed by Engineer-in-charge.
S&F box type mild steel ventilator with glazing bars dovetailed or welded and with one shop coat of zinc chromate primer complete all as specified and directed by Engineer-in-Charge.
S&F 3mm thick sheet glass ordinary quality and glazing with oil putty or with wooden beads(supplied along with shutters) in square n.exc 0.5 sqm in each pane complete all as specified and directed by Engineer in Charge.
S&F Galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanised wire staples complete all as specified and directed by Engr-inCharge.
S&F 3mm thick Figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane complete all as specified and directed by Engineer in Charge.
S&F solid PVC door frame WOOD GRAIN PRINTED of size 50x47mm made out of 5mm plain coloured PVC sheet reinforced with MS square tube in opening as per schedule complete all as specified & directed by Engineer-in-Charge.
S&F Factory made solid PVC door shutter 30mm thick (style) WOOD GRAIN PRINTED consisting of frame made out of MS tube for top and bottom rail MS frame shall be covered with heat moulded plain / coloured PVC "C"channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for styles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of plain colour PVC sheet to be fitted in the MS frame welded/ sealed to the style & rail with suitable PVC sheet beading and jointed together with solvent cement complete all as specified and directed by Engineer-in-Charge.
S&F 150mm long dia aluminium anodized handles cast type, fixed with steel screws complete as specified & directed by Engineer-in-charg
S&F 150mm long dia aluminium anodized tower bolts extruded section, fixed with steel screws complete as specified & directed by Engineer-in-charg
S&F 200mm long dia aluminium anodized tower bolts extruded section, fixed with steel screws complete as specified & directed by Engineer-in-charg
S&F 250 mm long aluminum alloy, anodised, sliding door bolt with hasp, staple (bolt type) not less than 12 mm dia and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminum alloy complete all as specified & directed by Engineer-in- charge.
S&F 300mm long mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified & directed by Engineer-in-charge.
S&F 140 mm long cover plate floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring complete all as specified and directed by Engineer-in-Charge.
Supply & fix Mild Steel medium weight colled rolled (ISI marked) butt hinges 100 mm long complete all as specified & directed by Engineer-in-Charge.
M&L for preparation of new primed steel surfaces of any description over 10cm in width or girth not otherwise described and applying two coat of synthetic enamel paint complete all as specified and directed by Engineer in Charge.
M&L for preparation of new wooden or wood based surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink wood primer complete all as specified and directed by Engineer-in-Charge.
S&F in repair Mild steel powder coated colour decorative type drapery curtain rod 20mm dia approved pattern & design, including brackets and pair of decorated end knobs, stop roller and fixed with powder coated mild steel flat iron brackets in the steel screws & PVC rawl plugs / grips etc complete all as specified & directed by Engineer-in- charge.
Demolition of cement concrete (unreinforced) of any description in ground floor & paving (not exceeding 15cm below/above ground level) and removing from site complete all as specified and directed by Engineer-in-Charge.
Dismantling floor, hearth or wall tilling including cement mortar bedding (but not backing) and rubbish of the premises complete all as specified and directed.
M&L for Roughening surfaces of old concrete roof/floor for removing old bitumen coat/any other type of treatment etc.by picking, sweeping clean and washing down with water to remove dirt/dust, etc. complete all as specified and directed by Engineer-in-Charge.
M&L Vitrified ceramic tiles 10mm thick (Square/rectangular) light shade polislhed area of each tiles not exceeding 0.36 Sqm in floors set and jointed in neat cement slurry and pointed in coloured cement to match, 15mm thick screed bed or bedding layer CM 1:4 for laying finishes complete all as specified and directed by Engineer-in-Charge.
All as per item No 31 above but as in vertical surfaces such as skirting, dados & risers to steps etc
S & F non skid ceramic coloured tiles 7 to 8 mm thick (Square/rectangular) area of each tiles exceeding 0.11sqm but n.exc 0.18 sqm, as in floors, etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed in cement mortar (1:4) complete all as specified and directed by Engineer in Charge.
S & F non skid ceramic coloured tiles 7 to 8 mm thick (Square/rectangular) area of each tiles exceeding 0.11sqm but n.exc 0.18 sqm, as in floors, etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed in cement mortar (1:6) complete all as specified and directed by Engineer in Charge.
S&F coloured Glazed ceramic tiles (light colour as approved) in vertical surface such as skirting/dados 450x 350x 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement with pigment ot match over and including rendering of 15mm thick rendering in cement mortar 1:4 on brick or concrete surface complete all as specified and directed by Engineer in Charge.
Machine cut kota stone slab in flooring, skirting/risers 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing incl 15mm thick screed bed or bedding layer CM 1:4 for laying finishes complete all as specified and directed by Engineer in Charge.
M & L for kota stone slab 20-25mm thick in skirting laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete and directed by Engineer in Charge.
Machine cut kota stone slab as in floors/treads of size of 18 -20 mm thick, set and jointed in cement slurry over & including screed bed of 20 mm thick in cement mortar (1:6) and pointed in cement mixed with pigment to match the shade of slab including rubbing, cutting and mirror polishing and rounding to edges of treads complete all as specified and directed by Engineer in Charge.
M&L Granite (of any type) 20mm thick machine cut, on cooking platform and like in cement mortar 1:4 including pointed with white cement 1:2 using marble dust with admixure of pigment to match the shade of granite stone including cutting & polishing complete all as specified and directed by Engineer in Charge.
M&L green marble of any colour size 16-18mm thick machine cut, bedded joint and pointed with grey cement slurry and incl screed bed of 20mm thick in cement mortar (1:6) incl rubbing, cutting, nosing and rounding of edge of sides complete all as specified and directed by Engineer in Charge.
M & L for 50mm thick plain cement concrete (1:3:6) type C-2 using 20mm graded stone aggregate as in plinth protection etc finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M & L for 75mm thick plain cement concrete (1:3:6) type C-2 using 40mm graded stone aggregate as in plinth protection etc finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
Taking down cement plaster on brick or stone wall etc. including raking out of joints, hacking for keys and scrubbing down with water etc and removal of debris upto a distance upto 50m complete all as specified and directed by Engineer-in-Charge.
M&L for taking down of cement plaster and rendering 15 mm thick in cement mortar 1:6 on fair faces of brick or concrete surface finished even and fair without using extra cement complete all as specified and directed by Engineer in Charge.
M&L for taking down of cement plaster and rendering 15 mm thick in cement mortar 1:4 on fair faces of brick or concrete surface finished even and fair without using extra cement complete all as specified and directed by Engineer in Charge.
M&L for taking down of cement plaster and rendering 10 mm thick cement plaster on ceiling surfaces in cement mortar (1:3) on fair faces of brick or concrete surfaces without using extra cement complete all as specified & directed by Engineer-in-Charge.
Providing & applying rising damp-proof coating system with single component ready to use damp-proof coating Roff Hydamp: 1. Surface Preparation : Thoroughly brush and clean all laitance, loose particles such as dirt, grease, mortar droppings, release agents, efflorescence, brid droppings, etc. All large voids or hollow portions must be removed and re-plastered. Non-moving cracks having width upto 5mm must be filled with Polymer based crack filler. 2. APPLICATION : Apply the first coat of Roff Hydamp with a paintbrush directly on the prepared surfaces. Allow to dry for a minimum 2-3 hrs. Apply one part of Roff Hydamp and 2 parts of OPC cement and make the putty, apply putty on the entire surface area. Allow it to dry for at least 3-4 hours. Apply the final coat of Roff Hydamp on the entire surface. Make : Dr Fixit Note : Complete application will be carried out by authorised distributor & Applicator : Dr Fixit Project division
M & L preparation of newly plastered or unplastered surfaces of wall by mechanical method i.e. Electric grinder and applying two coats of distemper oil emulsion white/ tinted with a wall care putty finished surface over one coat of primer by mechanical roller / hand roller complete all as specified and directed by Engineer in Charge.
M & L for complete removal of existing treatment of old decorated surfaces of ceiling by brooming down and scrapping down smoke soot, moulds, moss and efflorescence salt and treating oil and greasy spots and applying two coats of distemper oil emulsion white/ tinted with a wall care putty finished surface over one coat of primer complete all as specified and directed by Engineer in Charge.
M&L Preparation of new surfaces plastered or unplastered and applying three coat of white wash on wall complete all as specified and directed by Engr -in - charge.
M&L Preparation of new surfaces plastered or unplastered and applying three coat of white wash on ceiling complete all as specified and directed by Engr -in - charge.
M & L preparation of newly plastered or unplastered surfaces of ceiling and applying two coats of distemper oil emulsion white/ tinted with a wall care putty finished surface over one coat of primer complete all as specified and directed by Engineer in Charge.
M&L for complete removal of existing treatment of old decorated surfaces of ceiling by brooming down and scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying three coats of white wash complete all as specified and directed by Engr -in - charge.
M&L preparation of newly plastered or unplastered surfaces of wall and applying two coat of cement base paint over one coat of primer complete all as specified and directed by Engr -in - charge.
M & L for complete removal of existing treatment such as white wash, colour wash, synthetic enamel paint etc of old decorated surfaces of wall by brooming down and scrapping down smoke soot, moulds, moss and efflorescence salt and treating oil and greasy spots and applying two coats of cement base paint over one coat of primer complete all as specified and directed by Engineer in Charge. Note : Curing of surface will be carried out as per Para 15.15.3 of SSR Part-I.
Demolition of brick work built in cement mortar or cement lime mortar including all quoins,arches & pillars etc of any description and in any position complete all as specified and directed by Engineer-in-Charge.
Labour only for Brick work with fly ash bricks sub class 'B' bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed by Engineer-in-Charge.
M&L for washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 furrowing the under with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement Plaster 1:1/2:2 (1 Cement : 1/2 Coarse sand : 2 Stone chipping 10mm nominal size) in panels with grooves all round as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings complete all as specified and directed by Engineer-in-Charge.
M&L for forming grooves of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using removal of wooden battens, nailed to the under layer repair to the edges of panels and finishing the grooves complete all as specified and directed by Engineer-in-Charge.
Taking up or down existing galvanised steel water tubing (GI pipe) 15 mm bore including fitting/connection from wall/ceiling/floor etc. complete all as specified and as directed by Engineer-in-charge.
Taking up or down existing galvanised steel water tubing (GI pipe) 20 mm bore including fitting/connection from wall/ceiling/floor etc. complete all as specified and as directed by Engineer-in-charge.
S&F mild steel water tubes of size 15mm bore (medium grade) galvanised with all fittings and fixed concealed in walls and ceiling or laid in floors complete all as specified & directed by Engineer-in-charge.
All as per item No 62 here-in-before but except mild steel tubes complete all as specified and directed by Engineer in Charge
S&F mild steel water tubes of size 20mm bore (medium grade) galvanised with all fittings and fixed concealed in walls and ceiling or laid in floors complete all as specified & directed by Engineer-in-charge.
All as per item No 64 here-in-before but except mild steel tubes complete all as specified and directed by Engineer in Charge
S & F Gun metal globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed 20 mm dia of pipe complete all as specified and directed by Engineer in Charge.
S&F 20 mm stop valves/angle valve, cast copper alloy,screwed down high pressure,with crutch or butterfly handle scresed both ends for iron pipe or for unions and fixed complete all as specified and directed by Engineer in Charge.
S&F in repair 15 mm fancy type chromium plated Angle valve/stop valve, screwed down high pressure,with crutch or butterfly handle scresed both ends for iron pipe or for unions and fixed complete all as specified and directed by Engineer in Charge.
S&F anlge valves CP screwed both ends for 15mm bore of iron pipe or for union and fixed complete all as specified and directed and directed by Engineer in Charge.
S&F 15 mm fancy type chromium plated stop valves/angle valve, screwed down high pressure,with crutch or butterfly handle scresed both ends for iron pipe or for unions and fixed complete all as specified and directed by Engineer in Charge.
S&F 15mm bib taps, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed by Engineer in Charge.
S&F in repair 15mm bib taps, long body, chromium plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed by Engineer in Charge.
S&F in repair bib taps, fancy type CP, screwed for 15mm bore of iron pipe or for brass ferrule and fixed complete all as specified and directed by Engineer in Charge.
S&F in repair 15mm brass CP wall/basin/sink mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed by Engineer in Charge.
S&F 15mm brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed by Engineer in Charge.
S&F in repair vitreous china wash down water closet pan (pedestel pattern/EWC/longpan) white in colour including connection pipe to union of flushing cistern, inlet and overflow pipes,connecting only to flushing cistern anti-syphonage pipe with PVC flush pipe of 32mm dia and plastic seat cover with mild steel chromoum plated hinging and 'P' or 'S' trap device complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair PVC low level flushing cistern white 10 litre capacity, valveless syphonic action type with float, handle including flush pipe of polythene of low or high density of PVC 32mm dia, 60cm long and bracket etc and 15mm bore PVC connection complete all as specified and directed by Engineer-in-Charge.
Supply & fixing vitreous china bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe, including providing and fixing plugs, bedding urinal against wall in cement mortar (1:2), securing urinal to plugs with and including 60mm long brass screws, 32 mm dia full threaded PTMT waste coupling and 32mm dia waste pipe and pointing around urinal back in cement mortar, including Urinal spreader of PTMT suitable for fixing with 15 mm dia pipe and including Push tap high pressure of PTMT screwed for iron pipe 15mm bore (Minimum weight 47gms) complete all as specified & directed by Engineer-in-charge.
Supply and fixing vitreous China squatting pan Orissa pattern, size 580 x 440mm white / coloured with integral foot rest including flush pipe and connection to 100 mm dia "P" trap and to flushing pipe, anti syphonage pipe with WC including necessary lime concrete including 10 ltr PVC valveless syphonic action type, flushing cistern low level, white with inlet ball valve, float and handle including brackets etc complete.all as specified and directed.
S&F in repair wash hand basin flat back 550X400mm vitreous chine (white) with cantilever brackets embedded in concrete block including the following and fixed in repairs complete all as specified and directed (a)Brass chromium plated waste coupling 32 mm bore size (b) Waste pipe PVC 32 mm bore (c) Angle iron/cost iron brackets (d) CP Fancy type pillar cock 15mm.
S&F PVC Connections 15 mm size with PTMT nuts of length 450 mm long complete all as specified & directed by Engineer-in-charge.
S&F 1mm thick stainless steel sink with draining board, plugs, washers, waste pipe, union, waste coupling & cantilever brackets embedded in cement and sand mortar in wall, overall size of sink 915mm x 460mm with bowl size 410mmx330mmx160mm including taking down vitreous china sink complete all as specified. Make: NIRALI or equivalent ISI mark complete all as specified and directed by Engineer-in-Charge..
S&F stainless steel plate rack 1.25mm thick of size 900 x 775 x 250mm including angle iron brackets, taking down of 12 mm thick particle board shelf and removal from site complete all as specified and directed by Engineer in Charge.
S&F sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed by Engineer in Charge.
S&F Shelf of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 300gms) complete all as specified and directed by Engineer in Charge.
S&F of corner glass Shelf of size 30cm with CP railing complete all as specified and directed by Engineer in Charge.
S&F PTMT cabinet with mirror of size 450x300mm complete all as specified & directed by Engineer-in-Charge. Make : Prayag Cat No. 555 /polytuf / Pearl/ Shakti as approved by GE
S&F in repair brass chromium plated shower rose 125mm size with or without swivel joints including fixing to steel pipe of 15mm bore complete all as specified and directed by Engineer in Charge.
S&F Towel rail, 450mm long of PTMT fixed with and including chromium plated brass screws and wooden and plastic cleats ( minimum weight 170gms ) complete all as specified & directed by Engineer-in-Charge.
S&F Towel Ring of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 90gms) complete all as specified & directed by Engineer-in-Charge.
S&F brass CP Toilet paper holder complete all as specified & directed by Engineer-in-Charge.
S&F cast iron or mild steel peg set 175mm to 250mm with hooks fixed to wall complete all as specified and directed.
Dismantling CI/PVC 75mm/100mm /110mm bore pipes including fittings jointed in cement mortar and taking out from below or above GL or laid in floos or fixed to walls complete all as specified & directed by Engineer-in- charge.
S&F 110 mm bore PVC (SWR) pipe single socketed in any length with rubber ring joints, jointed with solvant and fixed to walls Cutting holes in brick wall built in cement mortar for inserting holdfasts, depth of embedded portion not exceeding half brick (measured from the face of jamb into the wall) and making good dismantled portion in cement mortor (1:3) or cement concrete (1:2:4) type B-I complete all as specified and directed by Engineer-in- charge.
S&F 110mm bore PVC(SWR) bends (any radius), diminishing pieces or tapers ( larger bore measured) laid in trenches or fixed in floors/walls complete all as specified and directed by Engineer-in-charge .
S&F 110mm PVC (SWR) branch piece, double (double Y) equal or unequal complete all as specified and directed by Engineer-in-charge .
S&F 75 mm bore PVC (SWR) pipe single socketed in any length with rubber ring joints, jointed with solvant and fixed to walls Cutting holes in brick wall built in cement mortar for inserting holdfasts, depth of embedded portion not exceeding half brick (measured from the face of jamb into the wall) and making good dismantled portion in cement mortor (1:3) or cement concrete (1:2:4) type B-I complete all as specified and directed by Engineer-in- charge.
S&F 75mm bore PVC(SWR) bends (any radius), diminishing pieces or tapers ( larger bore measured) laid in trenches or fixed in floors/walls complete all as specified and directed by Engineer-in-charge .
S&F 100mm bore cast iron sand cast soil, waste and spun pipe in any length with or without ears laid in trenches or in floors/walls with cement joints and provision of required number flat iron clamps of required size complete all as specified and directed by Engineer-in-charge.
S&F 75mm bore cast iron sand cast soil, waste and spun pipe in any length with or without ears laid in trenches or in floors/walls with cement joints and provision of required number flat iron clamps of required size complete all as specified and directed by Engineer-in-charge.
S&F 100mm bore cast iron bends (any radius), diminishing pieces or tapers ( larger bore measured) with access door,with(ordinary or inverted) spigot with parallel branches with single (Y) laid in trenches or fixed to walls complete all as specified and directed by Engineer-in-charge .
S&F 75mm bore cast iron bends (any radius), diminishing pieces or tapers ( larger bore measured) with access door,with(ordinary or inverted) spigot with parallel branches with single (Y) laid in trenches or fixed to walls complete all as specified and directed by Engineer-in-charge .
M&L in repairs CI Floor trap long neck 75 mm dia, with stainless steel grating including jointing to waste pipe fixed in cement concrete type B1, 1:2:4 complete all as specified and directed by Engineer in Charge.
S&F 75mm dia PVC (SWR) floor traps with CI/ stainless steel grating including jointing to waste pipe etc. complete all as specified and directed by Engineer-in-Charge.
S&F 75mm dia PVC (SWR) branch piece, double (double Y) equal or unequal complete all as specified and directed by Engineer-in-Charge.
S&F PVC (SWR) 'P' trap of 110/110mm bore complete all as specified and directed by Engineer-in-Charge.
S&F Grating doom 100 mm dia of PTMT (minimum weight 25gms) complete all as specified and directed by Engineer-in-Charge.
S&F Cast iron branch pieces, 100mm dia, single (equal or unequal), ordinary of inverted (spigot or socket type) or with parallel branches complete all as specified and directed by Engineer-in-Charge.
S&F 100mm bore cast iron branch pieces single equal ordinary spigot laid in trenches or fixed in floors/walls complete all as specified and directed by Engineer-in- charge.
S&F 75mm bore cast iron branch pieces single equal ordinary spigot laid in trenches or fixed in floors/walls complete all as specified and directed by Engineer-in- charge.
S&F cast iron vent cowl 75mm dia suitable for 75 mm bore pipe complete all as specified and directed by Engineer in Charge.
S&F PVC (SWR) gully trap 150/110 mm, setting and jointing with solvent cement with outlet pipes and PCC 1:2:4 type B1 filling around trap and 25 mm thick cover slab complete all as specified and directed by Engineer-in- Charge.
Dismantling water tank of capacity 1000 ltrs and removing to store complete all as specified and directed by Engineer in Charge.
Dismantling water tank of capacity 500 ltrs and removing to store complete all as specified and directed by Engineer in Charge.
S&F rotational moulded polyethylene water storage tank (cylindrical vertical triple layered white colour with closed top) hoisted and fixed in position of capacity 1000 litres including PTMT ball valve high pressure with polythene float and fly nut suitable for 20 mm bore GI pipe, 25mm bore GI washout pipe 15 cm long fitted with check nut, 20mm bore over flow pipe 1.50 metre long fitted with brass anti-mosquito nest coupling at the end of over flow pipe & 15mm bore GI air vent pipe 1.30 metre long fitted with tee at the end of air vent pipe (all GI pipes shall be medium grade) complete all as specified and directed by Engineer-in-Charge.
S&F rotational moulded polyethylene water storage tank (cylindrical vertical triple layered white colour with closed top) hoisted and fixed in position of capacity 500 litres including PTMT ball valve high pressure with polythene float and fly nut suitable for 20 mm bore GI pipe, 25mm bore GI washout pipe 15 cm long fitted with check nut, 20mm bore over flow pipe 1.50 metre long fitted with brass anti-mosquito nest coupling at the end of over flow pipe & 15mm bore GI air vent pipe 1.30 metre long fitted with tee at the end of air vent pipe (all GI pipes shall be medium grade) complete all as specified and directed by Engineer-in-Charge.
M&L for Water proofing treatment to RCC sunken slab (not exceeding 45cm depth of sunken) as specified below and as directed by Engineer-in-Charge:-(a) Applying 15 mm thick plaster in CM 1:3 with WPC on raised verticle surface. (b) Cleaning the surface with wire brush/coir brush, removing lose material like dust particles, dirt etc.(c) Creating fillet covering of 50mmx50 mm with polymer modified mortar on the junction of slab and walls. (d) Apply first coat of two component modified polymer coating on the horizontal and verticle surface. (e) Provision of glass fiber mesh of 2 x 2 mm immediately on above coating.(f) Apply second coat of two component modified polymer coating after 72 hrs. (g) Laying Cement concrete 1:4:8 over the coating as per requirment. (h) Joining the saintary pipes with the water proofing tape having bridging ability of more than 1.5 mm. (j) Filling the gap between the wall opening and saintary pipe with non shrink cementatious grout complete as specified Manufacturer.(k) The treatment to be carried out by authorised applicator of Water Proofing Manufacture. Make:- Dr. Fixit/Fosroc/BASF/STP Limited. Note: (i) The treatment shall be carried out by approved authorised applicator as per the manufacturers instructions and as directed by the Engineer in charge. (ii) The Plan area of floor shall be considered for payment and provn of PCC in filling. (iii) WPC will be measured separately under relevant item of BOQ.
Demolition of cement concrete (un-reinforced) in roof any thickness including plastering and leaping (whether full thickness removed or only part thereof) complete all as specified and directed by Engineer-in-Charge.
M&L rendering 10mm thick in cement plaster on roof in cement mortar 1:3 with WPC finished even and smooth without using extra cement complete all as specified and directed by Engineer in Charge. (WPC shall be measured and paid separately)
M&L for applying evenly a tack coat of industrial bitumen 85/25 @ 1.20 Kg/Sqm including preparation of roof surfaces complete all as specified and directed.
M&L Polythene film 300 micron thick laid on roof over a coat of bitumen primer, @ 0.30 to 0.50 Kg per sqm conforming to IS specification with lap joints 100mm complete all as specified and directed.
M&L lime concrete 80mm thick 1:2:5 (Lime : Surkhi : Brick balast 40mm) terracing on roof (excluding bitumen tack coat) complete all as specified and directed by Enigneer-in-Charge.
M&L for 40mm thick brick tiles laid on mud mortar & joints grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement on mud phuska complete all as specified and directed by Engineer-in-Charge.
Supply only Liquid water proofing compound complete all as specified and directed by Engineer in Charge.
Excavation in trenches not exc. 1.5 meter wide and not exc. 1.5 meter in depth in foul condition for foundation etc and getting out in soft/loose soil complete all as specified and directed by Engineer in Charge. Note : Necessary dewatering of water shall be included in the unit rate of item
Returning, filling in including spreading leveling watering and well ramming in layers not exc 25cm in soft /loose soil complete all as specified and directed by Engineer in Charge.
Removing excavated material or surplus soil not exc 50 meter and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed by Engineer in Charge.
Demolition and breaking up drain pipe (Salt glazed stoneware, AC or Reinforced concrete) 150 mm dia set in cement mortar including demolition of haunching concrete complete all as specified & directed by Engineer in Charge.
M & L for salt glazed stoneware drain pipe 150 mm dia grade 'A' laid in trenches making joints and testing complete all as specified and directed by Engineer in Charge.
S&F Reinforced concrete pipes class NP-2 laid, jointed and tested complete with collar of size 150mm (internal dia) all as specified and directed by Engineer in Charge.
M&L for Concrete bed to drain pipes using PCC 1:3:6 type C-2 40mm graded stone aggregate including packing under haunching against the sides of pipe after laid & tested for 150mm bore of pipes complete all as specified and direced by Engineer in Charge.
S & F Factory made SFRC (Steel fiber Reinforcement Concrete ) Manhole cover (without frame) medium duty 900mmx450mm x70mm thickness including 2mm thick flat iron frame all round complete all as specified and directed by Engineer in Charge.
M&L for broken brick hard core of gauge not exceeding 63mm deposited, spread and leveled in layers not exc 15cm thick, watered and rolled/rammed to a true surfaces complete all as specified and directed by Engineer-in-Charge
M&L for sand filling under floors or in foundation including watering and consolidation complete all as specified and directed by Engineer-in-Charge.
M&L for Coloured Machine pressed precast concrete interlocking paver blocks any shape and size conforming to IS 15658-2006 of 60mm thickness M-35 Grade, with grey cement and no pigment complete all as specified and directed by Engineer-in-Charge. Note : Paver block shall be approved by GE in writing before incorporation in work.
M&L for Coloured Machine pressed precast concrete interlocking paver blocks any shape and size conforming to IS 15658-2006 of 80mm thickness M-40 Grade, with grey cement and no pigment complete all as specified and directed by Engineer-in-Charge. Note : Paver block shall be approved by GE in writing before incorporation in work.
M & L for (factory casted, rubber moulded) pre-cast cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in kerb stone of any size or any thickness with plain fair faces, smooth finish, including chamfering, weathering, throating etc set in cement mortar 1:4, including necessary form work and excavation & earth work for embedding kerb stone at a depth as directed & temping around kerb stone and removal of surplus soil to a distance n.exc 50 metre & depositing where directed complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new concrete surfaces of any description, over 10 cm width or girth and applying two coats of plastic emulsion paint over a coat of cement primer complete all as specified and directed by Engineer-in-Charge.
M&L painting to plastered/concrete surface with two coats of road marking paint white, black or golden yellow including priming coat complete all as specified and directed by Engineer-in-Charge.
M&L PCC 1:3:6 type C2 (using 40mm graded aggregate) in foundation, filling and mass concrete complete all as specified and directed by Engineer-in-Charge.
M&L Brick work with fly ash with old size sub-class 'B' bricks, straight or curved on plan to any radius in half brick thick wall built in CM (1:4) complete all as specified and directed by Engineer-in-Charge.
M&L Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM 1:4 complete all as specified and directed by Engineer-in-Charge.
M&L PCC (1:2:4) type B-1 using 20mm graded stone aggregates as in copping etc and similar work including all necessary form work and fair finish to exposed surfaces without using extra cement complete all as specified and directed.
M&L flush pointing to brick or brick tiles in cement mortar 1:4 laid flat in paving etc complete all as specified and directed.
M&L extra for forming forming fair fineshed drain or channel exceeding 15cm in width or girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc complete all as specified and directed by Engineer in Charge.
M&L PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregates as in benching for manholes, bands, coping, bed plates including slightly rounded or chamfered angles including necessary formwork complete all as specified and directed by Engineer in Charge
S&F MS TMT Bars of 5 mm dia and over up to 10 mm dia in stirrups, spacers and binders,cut to length bent to shape required including cranking, binding spirally for hooping for columns hooking ends and biniding with and including MS wire annealed not less than 0.9 mm dia or securining with clip complete all as specified and directed by Engineer in Charge
S&F MS TMT Bars of 6mm to 8mm dia,cut to length,bent to shape required including cranking, binding spirally for hooping for columns hooking ends and biniding with and including MS wire (annealed) not less than 0.9 mm dia or securining with clip complete all as specified and directed by Engineer in Charge
S&F MS TMT Bars of 10 mm dia and over cut to length bent to shape required including cranking, binding spirally for hooping for columns hooking ends and biniding with and including MS wire annealed not less than 0.9 mm dia or securining with clip complete all as specified and directed by Engineer in Charge
Surface excavation not exceeding 30 cm deep and averaging 15cm deep in soft/ loose soil and getting out including cutting of grass roots, bushes if any and filling of lower portion with soil obtained from cutting or dressing complete all as specified and directed by Engineer-in-Charge.
Surface dressing in soft / loose soil n.exc 15 cm deep complete all as specified and directed by Engineer in Charge.
M&L for 75mm thick cement concerete type D-2, 1:4:8 using 40 mm graded stone aggregates as in subbase of floors complete all as specified and directed by Engineer in Charge.
M & L for cement concrete (1:2:4) type B1 using 20mm graded stone aggregate as in kerbs or benching etc including necessary form work complete all as specified and directed by Engineer in Charge.
Excavation in post holes (or similar holes) each n. exc 0.5 cum getting out in soft/loose soil returning filling in and ramming earth or broken rubble mixed with earth around in layer not exc 25cm watering and removing surplus soil to a distance not exc 50mtr and making good surface all as specified`and directed by Engineer in Charge.
S&F of Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified & directed by Engineer-in-charge.
S&F mild steel tubes of size 80mm bore (medium grade) galvanised with all fittings and fixed complete to walls and ceiling or laid in floors/on walls complete all as specified & directed by Engineer-in-charge
S & F steel work in tubular pole or pole including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS - 1161-1998 duly ISI marked, having min YST-240 Grade, complete all as specified & directed by Engineer-in-Charge. Make:- Tata/ Jindal/ Sail
M&L for cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation, filling /mass concrete finished even and fair without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for reinforced cement concrete type A-1, 1:1.5:3 using 20 mm graded crushed stone aggregate as in foundation including rafts, footings, foundation beams, plinth beams, base of columns etc complete all as specified and directed by Engineer in Charge.
M&L for reinforced cement concrete type A-1, 1:1.5:3 using 20 mm graded crushed stone aggregate as in columns, pillars, piers, posts and struts complete all as specified and directed by Engineer in Charge.
M&L Form work to sides of concrete foundations, footings, bases of columns, raft and raft beams,sides and soffits (if any) of foundation and plinth beams,and similar work; vertical or to batter for rought finished surfaces of concrete complete all as specified and directed by Engineer-in-Charge.
M&L for use and waste of form work to side and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc, also splays between floors and beams,etc for rough finished surfaces of concrete complete all as specified and directed by Engineer-in-Charge.
M & L for 25mm thick plain cement concrete (1:2:4) type B-0 using 12.5mm graded stone aggregate as in flooring complete all as specified and directed by Engineer-in-Charge.
M & L for 25mm thick cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate finished rough to receive glazed tiles complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 15 mm thick in cement mortar 1:6 on fair faces of brick or concrete surface (internal plaster) finished even and fair without using extra cement complete all as specified and directed by Engineer in Charge.
M&L for rendering 15 mm thick in cement mortar 1:4 on fair faces of brick or concrete surface (internal plaster) finished even and fair without using extra cement complete all as specified and directed by Engineer in Charge.
M&L for rendering 15 mm thick in cement mortar 1:4, on any faces of brick walls or concrete surfaces(external plaster) with WPC as per manufacturer instructions, finished even and smooth without using extra cement complete all as specified and directed by Engineer in Charge. Note :WPC shall be meausred and paid separately)
M&L for rendering 10 mm thick in cement mortar 1:4 on fair faces of brick or concrete surface (internal plaster) finished even and fair without using extra cement complete all as specified and directed by Engineer in Charge.
M&L for 10 mm thick cement plaster on ceiling surfaces in cement mortar (1:3) on fair faces of brick or concrete surfaces without using extra cement complete all as specified & directed by Engineer-in-Charge.
M&L Preparation of new surfaces plastered or unplastered and applying three coat of white wash on wall complete all as specified and directed by Engr -in - charge.
Cutting openings, through brick walls bulit in cement mortar for door, window and other openings or enlarging existing openings. converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc. to store and rubbish not exc. 50m complete all as specified and directed by Engr -in - charge.
M&L for Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required for 150mm dia complete all as specified and directed by Engr -in - charge.
S&F Solid PVC Wall Lining consisting of 5mm thick wood grain printed PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing complete all as specified and directed by Engineer-in-Charge.
S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing complete all as specified and directed by Engineer-in-Charge.
S&F Anodised aluminium powder coated frame for doors, windows with one or more rebates including joining cleat for fixing etc. including powder coating (minimum thickness of powder coating shall be 50 micron as per the specification) complete all as specified and directed by Engineer-in-Charge.
S&F powder coated coloured aluminium door shutters aluminium sections weighing 0.55 Kg/RM including necessary jointing cleats, glazing clips, rubber packing, powder coated aluminium snap beading, screws, powder coated aluminium fitting thickness of powder coating not less than 50 micron complete all as specified and directed by Engineer-in-Charge.
S&F Brass mortice lock, vertical type, size 100 mm, 4 levers complete all as specified and directed by Engineer-in-Charge.
M&L Broken glass coping on top of walls in CM 1:3 complete all as specified and directed by Engineer-in-Charge.
Cement conrete type B2, 1:2:4 (40mm graded aggregate) in foundations, filing and mass concrete complete all as specified and directed by Engineer-in-Charge.
M&L PCC 1:2:4 type B0 (12.5mm graded aggregate) as in foundation, filling and mass concrete etc complete all as specified and directed by Engineer-in-Charge.
Providing cement concrete type B0 1:2:4 (12.5mm graded aggregate) in lintels upto 1.5m clear spa, cills, steps, seismic and other similar bands, plinth courses, staing course, lacing courses, parapets and railing upto 60cm in height, copings etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for reinforced cement concrete M-25 (nominal mix) using 20mm graded stone aggregate as in beams, lintels upto 1.5 metre clear span, cills, steps, seismic and other similar bands, beams, parapets upto 60cm height and the like including weathering, slightly rounded or chamfered angles and throatings etc. complete all as specified and as directed by the Engineer-in-Charge.
Taking down carefully copper/aluminium point wiring (light, fan, socket, bell or power) complete including fittings such as switches, ceiling roses, pendent holders, light fittings any type, sockets, regulators etc and making good disturbed surfaces of walls and floors etc to match with the existing surfaces complete all as specified and directed by Engineer-in-Charge
Taking down carefully old distribution boards with MCB's single phase by unscrewing from boards complete all as specified and directed by Engineer-in-Charge.
Point wiring complete with 1100 volts grade FRLS insulated unsheathed cable of copper conductor cable multi stranded of size 1.5 Sqmm single core including PVC rigid concealed conduit medium grade of suitable size (not less than 20mm dia) with all accessories such as bend reducers /MS hooks, MS junction boxes 2mm thick galvanized steel pressed sunken terminal boxes of suitable sizes for mounting of switches sockets, fan regulators etc covered with 2.8mm thick plastic laminate (Hylam/Anchor) top cover including continuous earth wire of size 1.5 Sqmm PVC stranded copper conductor unsheathed, insulated stranded (Green colour) connected to common earth point dolly for One light point/call bell point/fan point to be controlled by one number one way PT switch complete all as specified and directed by Engineer in Charge.
All as per Srl item No. 186 here-in-before but Switch socket combination (multi purpose) 5 Pin 5 Amps 230 volts point to be controlled by one switch and wiring with 1.5Sqmm PVC unsheathed copper conductor cable 1.5 Sqmm PVC insulated earth wire on independent board.
All as per Srl item No. 186 here-in-before but on same board.
All as per Srl item No. 186 here-in-before Switch socket combination (multi purpose) 6 Pin 15 Amps 230 volts point to be controlled by one switch and wiring with 2.5Sqmm PVC unsheathed copper conductor cable 2.5 Sqmm PVC insulated earth wire on Same board/independent board.complete all as specified and directed by Engineer in Charge.
All as per item No 186 here in before but one light point controlled by two way swtiches complete all as specified and directed by Engineer in Charge.
S&F in replacement of switch Piano type single pole one way 5 Amp, 230 VAC supply complete all as specified and directed by Engineer in Charge.
S&F in replacement switch piano type single pole two way 5 Amp,230 VAC supply complete all as specified and directed by Engineer in Charge.
Supply and fixing in replacement bell push flush type 5 Amp complete all as specified and directed by Engineer in Charge.
S&F in replacement of socket two in one, 3 Pin 5 Amps 230 VAC supply, complete all as specified and directed by Engineer in Charge.
S&F in replacement of switch piano flush type single pole one way 15 Amps, 230 volts on laminated sheet top cover complete all as specified and directed by Engineer-in-Charge.(Note:-Sheet top cover included in point wiring)
S&F in replacement of socket piano flush type 6 pin 16 Amps, 230 volts complete all as specified & directed by Engineer-in- charge.
S&F in replacement bell ding dong AC 230V single phase complete all as specified and directed by Engineer in Charge.
S&F in replacement of ceiling rose three terminals with bakalite 20mm back plate complete all as specified and directed by Engineer-in-Charge.
S&F in replacement 5 speed electonic regulator suitable for ceiling fan 1200mm/ 1400mm sweep,socket size,electronic type 230 Watt complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of PVC Lamp holder suitable for and including batten fittings ,LED Lamp 9 watts with bakalite 20mm back plate etc complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of complete set of tube light fitting, 1x18 watt LED (4 feet long) 230 volt, decorative ultra slim linear LED lighting fixture with environment friendly, energy efficient ready to use pack etc with all acessories such as LED adopter, decorative bipin holder, LED tube internally prewired and including connecting up with twin core twisted flexible copper conductor cable of suitable size including taking down old unserviceable light fittings any size complete all as specified and directed by Engineer in Charge. Make: Bajaj cat No.BCLSB 18W LED or Havells/Phillips
S&F compact & decorative energy efficient LED mirror light fitting with antiglare diffuser and decorative end caps suitable for 1x 12 watt fitting including LED lamp 12 watt including taking down old unserviceable light fittings any size complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of 1X10 watt LED retrofit type bulk head fitting luminaries die cast aluminium alloy body heat resistant prismatic glass cover with specially designed gasket, lamp holder etc complete with all accessories and including connecting up with twin core twisted flexible copper coductor cable with suitable size of 230 volt,50 HZ including taking down old unserviceable light fittings any size complete all as specified and directed by Engineer-in-Charge. Make :Bajaj cat part no. BIBWP 10W LED or equivalent cat part of Philips / Havells
Taking down ceiling fan / exhaust fan and fixing in its original position after complete repair complete all as specified and directed by Engineer in Charge.
S&F in replacement of MCB DB double door of sheet metal TPN 4 way with 415 Volts complete with and including MCCB 63 Amps with fixed thermal magnetic setting with breaking capacity not less than 16 KA complete all as specified & directed by Engineer-in-Charge.
S&F in replacement of MCB distribution board double door of sheet metal single pole and neutral 12 way with 200 amps rated bus bar 240 volts complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of MCB ,SPN 240 volt 32 Amp including taking down old unserviceable MCB any size complete all as specified and directed by Engineer-in-Charge. Make-Havells/Siemens/Legrand /Indo Asian.
S&F in replacement of MCB single Pole 240 Volts 6 to 32 Amp including taking down old unserviceable MCB any size complete all as specified and directed by Engineer in Charge. Make-Havells/Siemens/Legrand /Indo Asian.
Taking down old unserviceable sub main wiring of any size from wall and coduit etc complete all as specified and directed by Engineer-in-Charge..
S&F sub main wiring with two runs of single core PVC FRLS sheathed insulated copper cable of 6 sqmm size, multi stranded 1100 volts grade with PVC insulated FRLS copper wire 6sqmm for continous earth wire drawin into existing concealed conduit complete all as specified and directed by Engineer-in-Charge. Note ;- Two runs of 6 Sqmm copper cable and one run of 6 sqmm copper wire earth continuty conductor in existing conduit with accessories shall be measured as one length)
Supplying laying and fixing in replacement of XLPE insulated stranded and PVC sheathed heavy duty armoured electric cable with standard aluminium conductor 1100 volts grade confirming to IS-1554 cross sectional area 16 Sqmm 4 core including thimbles/lugs complete with and including passing through pipes or laid under floor or through walls etc including taking down old defective cable any size all as specified and directed. (Note : Excavation, earthwork, Sand Cushioning, Cable covers, Pipe for cable protection to be measured and paid for separately)
Supply and laying burnt bricks sub class 'B' old size for cable protection laid length wise perpendicular to the axis of cable complete all as specified and directed by Engineer in Charge.
M & L for sand cushioning with river washed and screened dry fine sand to under ground cable 23cm thick, 15 cm below the cable and 8 cm after laying the cable complete all as specified and directed by Engineer-in-Charge. NOTE;- Thickness after punning shall be considered for payment.
S&F Steel tubes 40mm bore light grade galvanised for cable protection fixed to poles/laid under floor/under road crossing with all fittings complete all as specified and directed by Engineer in Charge.complete all as specified and directed by Engineer-in-Charge.
S&F Steel tubes 25mm bore light grade galvanised for cable protection fixed to poles/laid under floor/under road crossing with all fittings complete all as specified and directed by Engineer in Charge.complete all as specified and directed by Engineer-in-Charge.
S&f Gun Metal globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed 25mm dia of pipe complete all as specified and directed .
M&L for MS clamp fabricated from MS flat of size 40mmx3mm including nuts, bolts, washers, bending cold or hot drilling holes for bolts in any shape or size for holding GI pipe with pole and wall complete all as specified and directed by Engineer in Charge.
M & L Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to and including 4mm dia (8 SWG) GI earth wire from earth plate to main switch board including necessary GI bolts, nuts, check nuts, washers, thimble etc to the extend 7.5 mtr as earth lead by means of GI bolts & nuts etc, connecting to LT panel wlith provision of charcoal and salt all as per electrical plate No 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade) for watering and including funnel, wire mesh, RCC cover & frame, PCC (1:3:6) type C2 using 20mm graded crushed stone aggregate) as in earthing pit including necessary excavation and earth work, returning , filling, ramming and remove of soil to a distance not exc 50 mtr, make good to match with existing surface and testing on completion complete all as specified and directed by Engineer in Charge. Note : The unit rate including earthing lead & protection pipe upto 7.5 meter from top to earth plate.
S & F exhaust fan 300mm sweep, 380 RPM trans air (4 blade) 70 Watt, with louver shutter suitable for operation on 220/230 volts, single phase , AC and complete all as specified & directed by Engr-in-charge. Make : Crompton, Khaitan, Usha, Bajaj, Havells Note :- A Sum of Rs. 17,525.00 will be deducted on account of credit for dismantling/ demolished/ taking down material. Please refer detail on srl page No. 35 & 36 (Schedule of credit) of Tender Documents.
M/s Surjit Singh and bros
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .