| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.4 LAccepted-AOC 15 CP COLONY MORAR GWALIOR MP 474 006 | GWALIOR | GWALIOR | MADHYA PRADESH | 474006 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹13.5 L+₹2.2 L (19.9%)Rejected-Finance | L2 | Rejected-Finance Not being lowest tender | |
| 3 | L3₹15.8 L+₹4.6 L (41.0%)Rejected-Finance | L3 | Rejected-Finance Not being lowest tender | |
| 4 | L4₹16.9 L+₹5.7 L (50.6%)Rejected-Finance | L4 | Rejected-Finance Not being lowest tender | |
| 5 | L5₹17.7 L+₹6.4 L (57.2%)Rejected-Finance | L5 | Rejected-Finance Not being lowest tender |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
27 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF ADM AREA
GE AF ADM AREA GWALIOR-474020
REPAIR/MAINT OF OVERHEAD LINES AT CHETAK COMPLEX AND SMQ AREA AT AF STN GWALIOR
2023_MES_625632_1
8366/E8
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
GE AF ADM AREA GWALIOR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE AF ADM AREA
₹40,000
Yes
24 Jan 2024
30 Oct 2023
5 Dec 2023
30 Oct 2023
27 Nov 2023
13 Nov 2023
Amount
Dismantling & taking down of existing worn out / unserviceable aluminium conductor steel reinforced (ACSR) of any type /size & in any position from existing LT/HT Poles/Lines all as specified & directed.
Re-fixing and stringing of old ACSR conductors and earth wires including cradles, of any size & type and in any position, as in LT/HT overhead lines, on existing poles, including opening of connections and binding wires, restringing and tightening of conductors/earth wire in position, removing sag, binding to insulators with new aluminium wire, making and connecting new jumper connections etc. including PG Clamps and testing complete all as specified and directed. Note: The quoted rates shall be deemed to include the following provisions also :- (i) Setting/adjusting etc. in position of cradles. (ii) Old serviceable spacers of ACSR conductor shall be reused and fixed as directed by Engineer-in-Charge. (iii) Any complaint of broken ACSR conductor shall be attended by the contractor within two hrs, in case of failure the penalty of Rs.1000 per hours shall be recovered from the contractor.
Supply and fixing of aluminium conductor steel reinforced (ACSR) of any size/type on LT poles/lines including PG Clamps, stringing, tightening, binding to insulators with aluminium wire making and connecting jumpers, connections of existing cables etc. including commissioning and testing complete all as specified & directed by Engineer-in-Charge. Note:-Old serviceable spacers obtained from taking down of ACSR conductor under item No.1.00 shall be reused and fixed as directed by Engineer-in-Charge.
Dismantling & taking down of existing worn out / unserviceable GI wire of any description/size & in any position from existing LT/HT Lines including cradle guard wires all as specified & directed.
Material and labour for supplying, stringing and fixing GI continuous GI earth wire of size 4 mm / 3.15mm dia on LT/HT poles as in cradle guards / earth wires etc. including binding complete all as specified & directed.
Dismantling & taking out of old existing unserviceable steel & iron items from poles such as cross arms, bracing, supports, clamps and back plate fabricated from structural steel sections including nuts & bolts, washers of any description and in any position from LT over head line poles/ street light poles complete all as specified & directed by Engineer -in-Charge.
Fixing Only old fabricated mild steel structure such as cross arms, bracing, supports, clamps and back plate including nuts, bolts & washers on LT over head line poles/ street light poles complete all as specified & directed by Engineer -in-Charge.
Supply, fabrication and fixing for mild steel structure such as cross arms, bracing, supports, clamps and back plate fabricated from structural steel sections including nuts & bolts, washers of any description on LT over head line poles/ street light poles complete all as specified & directed by Engineer -in- Charge.
Dismantling and taking down existing serviceable/unserviceable/ de-shaped/worn out LT/HT steel tubular / PCC pole of any shape, size & height including demolition of existing PCC foundation complete all as specified and directed.
Supply and erecting steel tubular swaged pole (410 SP-31) 9 mtr long, complete with cast iron base plate, pole cap / finial taper plug, bolts, nuts and washers, welded reduced section and longitudinal weld throughout entire length of pole complete all as specified and dircetd.
M&L for PCC (1:3:6 ) type C-2 ( using 40 mm graded stone aggregates ) as in sub base foundation etc. complete all as specified and directed.
M&L for PCC (1:2:4 ) type B-1 with20 mm graded stone aggregates for coping of poles with all necessary form work complete all as specified and directed.
M&L for PCC (1:4:8 ) type D-2 with 40 mm graded stone aggregates for foundation of pole of complete all as specified and directed.
M&L for stay assembly comprising of 16 mm dia, 1.80 meter long galvanized stay rod, having 7/3.15mm GI stay wire stranded and 230mm x 230mm x 6mm thick stay plate, complete all as shown on electrical plate No 1 of SSR, Part-I with and including all necessary fittings/ accessories like loop type insulator, stay clamps, necessary excavation and earth work in any type of soil and PCC works in (1:3:6) type C-2 (using 40mm graded stone aggregate) including taking down and dismantling old unserviceable stay assembly etc. complete all as specified and directed by Engineer-in-Charge.
M&L for stay assembly comprising of 20 mm dia, 1.80 meter long galvanized stay rod, having 7/3.15 mm GI stay wire stranded and 230mm x 230mm x 6mm thick stay plate, complete all as shown on electrical plate No 1 of SSR, Part-I with and including all necessary fittings/ accessories like loop type insulator, stay clamps, necessary excavation and earth work in any type of soil and PCC works in (1:3:6) type C-2 (using 40mm graded stone aggregate) including taking down and dismantling old unserviceable stay assembly etc. complete all as specified and directed by Engineer-in-Charge.
Dismantling & taking out of old existing unserviceable insulators of any description and in any position from LT/HT poles all as specified & directed.
Fixing Only old Insulators of any shape, size in any position including nuts, bolts, washers and all connected accessories as specified and directed.
Supply and fixing pin type porcelain, vitreous, white, brown or green insulators, including one galvanized mild steel spindle two galvanized iron washers and one galvanized iron nut, 100mm height and 65mm dia suitable for working pressure up to and including 1100 volts grade complete all as specified for LT lines fixed on poles. Make Jayshree/ Modern /Jaipuria brothers/Mysore porcelain /WS insulator.
All as item No 18.00 here-in-before but 150 mm hight, 150 mm dia for 11000 volts grade.
Supplying & Fixing Shackle type 100mm height and 115 mm dia insulator, porcelain, vitreous, white, brown or green including galvanized mild steel strap 31mm X 5mm, insulator bolts 14mm dia with suitable washers and nut, suitable for working pressure up to & including 1100 volts, complete all as specified and directed by Engineer-in-Charge fixed on LT poles. Make:- Jayshree/Modern /Jaipuria brothers/ Mysore porcelain/ WS insulator.
M & L Disc type insulator, porcelain, vitreous 145 mm high and 255 mm dia ball and socket type, white, brown or green single disc assembly for tention with tention clamps for conductors, working pressure 11000 volts.
Dismantling & Taking down Old Anty climbing devices and Supply and Fixing Anti climbing devices, comprising 2.24mm dia galvanized steel 2-strand barbed wire with 2.00mm dia barbs wrapped spirally round poles, to a length of 0.5 to 1.0 meter clamped and properly secured or as ordered clamps will be measured separately all as specified directed.
Dismantling and taking down existing unserviceable lightening arrestor of any capacity and any description and Supply, fixing, commissioning & testing of transmission class lightening arrestor 11 KV of Discharge capacity 65 KA NDC confirming to EC-99 -41/1990 including brackets, clamps, bolts, nuts and washers complete all as specified and directed by Engineer-in-Charge. Make:-Oblum/ Jaipuria Brothers/Elpro.
Disconnecting and taking down from poles existing street light fittings, bracket, nut-bolt and connected items of any type or any watt and size.
S&F ENDURA PULSE LED Street Light MADE UP of pressure die cast housing with toughened glass and individual high power LEDs with secondary optics, IP 66 protection and impact resistance of IK07. 60 W including GI light grade pipe bracket of suitable shape 1.5 mtr long and connecting cable 1.5 sqmm 3 core copper conductor and PVC conduit pipe 15 mm bore heavy duty ISI marked duly clamped with pole at 2 places complete all as specified and directed Make:-HAVELLS Cat part No LHETBXU7PA6J060 or equivalent in Bajaj,C&S, and CG.
Disconnecting, taking out and removing old existing unserviceable/repairable underground, LT cable of any description and in any position complete including taking down protection pipe, bricks covers etc. all as specified and directed by the Engineer-in-Charge for the following sizes.
(a) 16 Sqmm to 25 Sqmm any core
(b) 35 Sqmm to 70 Sqmm 3½ core
(c) 185 Sqmm to 300 sqmm 3½ core
Note for item No 26.01 to 26.03 : Excavation /earth work shall be measured and paid separately under relevant items of Schedule/BOQ.
Laying only, jointing, commissioning and testing XLPE / P.V.C insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade of any type and any make laid in trenches/ducts, floors, fixed to walls/ Poles etc. complete all as specified and directed by the Engineer-in-charge for the following sizes :-.
(a) 16 Sqmm to 25 Sqmm any core
(b) 35 Sqmm to 70 Sqmm 3½ core
(c) 185 Sqmm to 300 Sqmm 3½ core Note for Item NO 27.01 to 27.03: Old useable cable obtained from 26.00 shall be used under this item.
Supply, laying, jointing and testing XLPE / PVC insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade of any description and any make laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed by the Engineer-in-charge for the following sizes :-
(a) 10 Sqmm 2 Core
(b) 16 Sqmm 2 Core
(c) 25 Sqmm 4 core
(d) 35 Sqmm 3½ core
(e) 50 Sqmm 3½ core
(f) 240 Sqmm 3½ core
(g) 300 Sqmm 3½ core
Excavation in trenches in soft & loose soil not exceeding 1.5 meter deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes etc. all as specified and directed by Engineer-in-Charge including removing cable protection PCC covers/ bricks & stacking serviceable covers / bricks for reuse and disposal of unserviceable covers within 50 m all as directed. Note : Excavation shall be made carefully in order to avoid damage of existing cables and protection covers.
Returning, filling in including spreading, leveling, watering and well ramming in layers of 25 cm thick after the cables etc. are laid, jointed & tested complete all as specified and directed by Engineer-in-Charge.
Removal of surplus excavated spoil not exceeding 50 Mtr distance and depositing where directed by Engineer-in-Charge at a level not exceeding 1.5 m above the starting point complete all as specified.
Material & labour for sand filling with clean dry find sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed by Engineer-in-Charge.
Supplying & Laying Sub Class `B’ bricks old size with axis of the bricks perpendicular to the axis of the cable as in cable protection all as specified and directed by Engineer-in-Charge.
Laying only old retrieved serviceable bricks/ cable covers for cable protection with axis of the bricks/ cable cover perpendicular to the axis of the cable of any description as obtained from dismantling of the cable complete all as specified and directed by the Engineer-in-Charge.
Disconnecting, dismantling and taking down existing unserviceable spacers of any size/ ways in any position from the LT electric overhead lines of any height and supplying and fixing new PVC insulated spacers suitable for separating existing LT OH lines complete all as specified and directed.
Clearing 2 mtr all around LT line by cutting tree branches of any numbers and any girth on any numbers of conductors/earth wire complete all as specified and directed by Engr-in-charge.
Disconnecting LT cable of size from 16 Sqmm 4 core to 35 Sqmm 3.5 core from existing panel taking out loop of cable not more than 2.5 M length, cut the worn out portion of cable including replacement the lugs, nut-bolt and washers of suitable size and reconnect the existing system and including LT joints of cable size 16 sqmm 4 core to 35 sq mm 3.5 core and all specified and direceted.
Disconnecting LT cable of size from 50 Sqmm 3.5 core to 120 Sqmm 3.5 core from existing panel taking out loop of cable not more than 2.5 M length, cut the worn out portion of cable including replacement the lugs, nut-bolt and washers of suitable size and reconnect the existing system and including LT joints of cable size 50 sqmm 3.5 core to 120 sq mm 3.5 core and all specified and direceted.
Disconnecting LT cable of size from 150 Sqmm 3.5 core to 300 Sqmm 3.5 core from existing panel taking out loop of cable not more than 2.5 M length, cut the worn out portion of cable including replacement the lugs, nut-bolt and washer of suitable size and reconnect the existing system and including LT joints of cable size 150 sqmm 3.5 core to 300 sq mm 3.5 core and all specified and direceted.
Supplying, laying & jointing GI tubing, 80 mm bore, light grade as in sleeving etc. laid in trenches / ducts / horizontal bore hole complete all as specified and directed by Engineer-in-Charge.
Supplying, laying & jointing GI tubing, 50 mm bore, light grade as in sleeving etc. laid in trenches / ducts / horizontal bore hole complete all as specified and directed by Engineer-in-Charge.
M&L for surface excavation over the areas around the poles/feeder piller boxes/ sub stations not exceeding 15cm depth including cleaning the bushes and vegetation and leveling incl removal of surplus soil in hard/ dense soil. Note:- All necessary T&P and safety equipments required for the job will be provided by the contractor.
Removing/scraping the existing pre-painted aluminium paint preparing surface for applying new paint with two coats of approved quality aluminium paint on 11 mtrs long existing HT pole above coping all as directed and required along with existing accessories such as clamps, channels, angles etc. including numbering of poles with white paint on black back ground as per the directions and three Nos of reflector strips of 15 CM width over the pole surface on height of 1.50 mtr from GL in Red, Yellow, Green colours as approved all to the entire satisfaction of Engr-in-Charge.
All as specified in Sl item No 43.00 here-in-before but for 9 mtrs long LT poles.
Removing/scraping the existing pre-painted aluminium paint preparing surface for applying new paint with two coats of approved quality aluminium paint on 2 Pole structure all as directed and required along with existing accessories such as clamps, channels, angles, bracing etc. including numbering of poles with white paint on black back ground as per the directions and three Nos of reflector strips of 15 CM width over the pole surface on height as directed in Red, Yellow, Green colours as approved all to the entire satisfaction of Engr-in-Charge.
Removing/scraping the existing pre-painted aluminium paint preparing surface for applying new paint with two coats of approved quality aluminium paint on 4 Pole structure all as directed and required along with existing accessories such as clamps, channels, angles, bracing etc. including numbering of poles with white paint on black back ground as per the directions and three Nos of reflector strips of 15 CM width over the pole surface on height as directed in Red, Yellow, Green colours as approved all to the entire satisfaction of Engr-in-Charge.
Disconnecting GOD of capacity 11KV, dismantling of GOD for complete repair & overhauling and checking the serviceability of spares and operating mechanism and replacement of defective/worn out spare parts for making the GOD functional including reassembling of operating mechanism, oiling & greasing of moving parts, fine setting of mechanism, making the GOD perfect operational in manual mode complete all as specified and directed. Make : Pactil/Jaipuria Brothers/Atlas Note :- New spare parts replaced for GOD shall be measured and paid for separately under respective items of Sch 'A' as “supply only” but fixing element of same shall be deemed to be included under this item.
Supply only the following new parts suitable for GOD of 11KV repaired under Schedule `A' item No 47 above. NOTE: - (i) The new parts shall be suitable to match with the existing GOD. (ii) Fixing element of these items like nut, bolts, washers etc. is deemed to be included under the rates quoted by the contractor for respective Schedule `A'/BOQ item No 47.00 here-in-before.
(a) 11KV post type insulator
(b) Male contact/moving contact blade.
(c) Female contact/fix contact Jaw
(d) MS Jumper carrier
(e) Tinned copper flexible jumper
(f) Back connector plate
(g) Fix top contact / L contact
(h) Fix bottom contact
Supply, fixing, commissioning and testing of outdoor, gang operated switch, tilting type, 11KV of current rating upto 200 Amps, triple pole, each pole consisting of galvanized steel base, HT insulators as per IS, non ferrous knife and spray, loaded contacts, arcing horns of adequate section to break magnetizing current of the transformers, horizontal GI pipe of adequate length for phase separation, adequate length of GI pipes for operation from ground level and operating handle with locking arrangement complete in both OFF & ON positions. All ferrous parts hot dripped galvanized and non ferrous heavily tinned to with stand weather and suitable for vertical mounting complete all as specified and as directed by Engineer-in-Charge. Make: - Pactil/Jaipuria Brothers /Atlas.
Taking down unserviceable Drop out fuse set outdoor type ratio 200 Amps of 11 KV and supply and fix drop out fuse set 11 KV, 200 Amps mounted on insulators and steel frame complete all as specified and directed.
Supply & erect in position steel tubular pole complete with MS base plate finial taper plug, cap bolt, nut screws etc all as specified regarding swaged pole of type 410 SP-55 11 mtrs long incl painting with one coat of red oxide paint and there after two coats of aluminium paint and black bitumen paint on hidden surface in foundation of structure of approved make/quality.
M&L for earthing complete with galvanised steel earth plate electrode of size (600 x 600 x 6.3) mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level duly connected to galvanised earth lead strip 25 x 4 mm mm dia by means of bolts, nuts chek nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 connected to earth test point all as specified including necessary earth work, gun metal test point block, PCC work, in order to ensure satisfactory earth resistance result to the entire satisfaction of Engr-in-Charge.
S&F MCCB 630 Amps 4 Pole, 36 KA, 415 V, 50 Hz with thermal setting between 70% to 100% adjustable type and connecting up in the existing panel location including taking out existing unserviceable MCCB complete all as specified and as directed by Engineer-in-Charge.
S&F MCCB 400 Amps 4 Pole, 36 KA, 415 V, 50 Hz with thermal setting between 70% to 100% adjustable type and connecting up in the existing panel location including taking out existing unserviceable MCCB complete all as specified and as directed by Engineer-in-Charge.
S&F MCCB 250 Amps 4 Pole, 36 KA, 415 V, 50 Hz with thermal setting between 70% to 100% adjustable type and connecting up in the existing panel location including taking out existing unserviceable MCCB complete all as specified and as directed by Engineer-in-Charge.
S&F MCCB 200 Amps 4 Pole, 36 KA, 415 V, 50 Hz with thermal setting between 70% to 100% adjustable type and connecting up in the existing panel location including taking out existing unserviceable MCCB complete all as specified and as directed by Engineer-in-Charge.
S&F MCCB 100 Amps 4 Pole, 36 KA, 415 V, 50 Hz with thermal setting between 70% to 100% adjustable type and connecting up in the existing panel location including taking out existing unserviceable MCCB complete all as specified and as directed by Engineer-in-Charge.
Taking down old unservisable and S &F fluorescent board 8' x 2' made out of 24 gauge GI sheet and front with acrylic sheet total enclosed with computerised letter writtings of size not less than 100 mm as diirecetd by Engineer in charge and inside with 4' long 02 Nos of 18 Watt LED tube light fitting complete with time control switch, MCB and battery back up with timer and synchronised motor board including writting, with complete service connection of 2.50 Sqmm 3 Core copper sheathed cable 10 metre long including protection pipe service connection from the pole by means of 40 mm dia light grade pipe to the board including excavation, returning filling and removing out surplus soil, Complete all as specified and directed.
Demolition/Dismantling of existing PCC platform of Transformer Sub Station of any capacity and M& L for PCC 1:3:6 type C1 using 20 mm graded stone aggregate, repairing the cable duct after disconnecting the LT/HT cable from transformer to LT panel and relaying the same after repair of duct and laying the existing GI plate for covering of cable tary complete all as specified dircetd by Engr-in-Charge.
Kumar Sales Corporation
Mukesh Enterprises
UNIVERSAL AGENCY
Om Electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .