Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.3 LAdmitted-Finance | ₹9.3 L | L1 | Admitted-Finance |
| 2 | L2₹13.7 LAdmitted-Finance ECIL X ROADS HYDERABAD 500062 | MEDCHAL MALKAJGIRI | TELANGANA | 500062 | ₹13.7 L | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | NAVANEETHA ELECTRICALS L1 | SRI BALAJI ENTERPRISES L2 |
|---|---|---|---|---|---|
| 1.00SH:I (OCM of EMS) | |||||
| 1.01Providing operation and Comprehensive Maintenance of following Electro- mechanical services including monitoring, managing the operation of the Electro- mechanical services by deploying suitable sufficient personnel to fulfill the SLA parameters, etc. to maintain uninterrupted operation of EMS services as per given terms and conditions. The EMS is as per the size of services attached. | |||||
| 1.02Pump sets i/c Panel/board | |||||
| 1.03Compound-Lighting | |||||
| 1.04Common area lighting | |||||
| 1.05Minor components of E.I. | |||||
| 1.06NOTE:- | |||||
| 1.091) Contractor to take all steps to undertake preventive/special maintenance and testing to keep the system at optimum working condition. | |||||
| 1.102) Engineer-in-charge can rearrange timings of deployment as per site requirement and site conditions. | |||||
| 1.113) In case of Non-Compliances, recoveries shall be applicable as per the relevant terms & conditions. | |||||
Tender Value
₹5.7 L
EMD Value
₹11,353
Closing Date
27 Jan 2026, 3:00 pmClosed
EET
EET BSNL ECII Kellys Chennai
Operation and Comprehensive Maintenance of pumps, compound light and common area lighting including call basis maintenance of Electrical installation of BSNL Staff Quarters at CIT Nagar
2026_BSNL_262792_1
NIT No 79/EE-T/EC-II/CH/2025-26
Open Tender
Electrical Works
730 days
CIT Nagar Chennai
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
BSNL Chennai Telephones
₹11,353
5 Feb 2026
13 Jan 2026
28 Jan 2026
13 Jan 2026
27 Jan 2026
13 Jan 2026
13 Jan 2026 - 27 Jan 2026
SH:I (OCM of EMS)
Providing operation and Comprehensive Maintenance of following Electro- mechanical services including monitoring, managing the operation of the Electro- mechanical services by deploying suitable sufficient personnel to fulfill the SLA parameters, etc. to maintain uninterrupted operation of EMS services as per given terms and conditions. The EMS is as per the size of services attached.
Pump sets i/c Panel/board
Compound-Lighting
Common area lighting
Minor components of E.I.
1) Contractor to take all steps to undertake preventive/special maintenance and testing to keep the system at optimum working condition.
2) Engineer-in-charge can rearrange timings of deployment as per site requirement and site conditions.
3) In case of Non-Compliances, recoveries shall be applicable as per the relevant terms & conditions.
4) Wherever additional manpower required for carrying out the work of opeation and repair/ maintenance, the same shall be arranged by the firm at no extra cost.
5) Minor material for common areas such as 6A Switch/Socket/ 15A Switch/Socket/Starter/Starter holder/ Side Holder i/c fiber base//Fan Capacitor//Fan Canopy/ Angle holder/ Batten Holder/ Ceiling rose/ Bell push/Bell Buzzer/Gang Box 2/4 way/ Flourescent Tube Rod has to be arranged by contractor without any extra cost.
6) The minor materials for inside of Staff Quarters shall be same as 5) above except the Flourescent tube rods.
7) The Common areas shall include all areas except the inside of Staff Quarters.
For Staff Quarter Colony at CIT Nagar
Supplying & fixing of following material on need basis / call basis for repairing & attending breakdown maintenance work for repairing of electrical items like fluorescent fitting, ceiling fans, Main board, Sub Main board etc i/c dismantling, reconnection, testing, commissioning etc as required.
1) The required suitable manpower for carrying out the work of repair/replacement/breakdown maintenance shall be arranged by the firm at no extra cost.
(2) The defective material shall be the property of agency & firm should consider suitable price rebate for the same while quoting. The material under replacement shall be similar to existing defective material or as per product directory)
Step type Electronic Fan Regulator
Electronics choke for 36W FTL fitting
DP switch - 32 A
3 mm thick hylam sheet
Door Bell (Chime)
Single pole - 6A to 32 A
double pole MCB - upto 32A
Isolator 4P - 63A
20W LED Batten
9w LED Bulb - Pin type (B-22)
1 x 1.5 sqmm PVC insulated copper wire i/c making connections
1 x 4 sqmm PVC insulated copper wire i/c making connections
1 x 6 sqmm PVC insulated copper wire i/c end termination and making connections
1 x 10 sqmm PVC insulated copper wire i/c end termination and making connections
Supply of of 2x6 Sqmm Al aromured UG Cable
Supply of 4x25 Sqmm Al armoured UG Cable
Laying and fixing of one number PVC insulated and PVC Sheathed / XLPE power cable of 1.1 KV grade upto 35 Sq.mm size (clamped with 1mm thick saddle) on wall surface as required.
Laying of one number PVC insulated and PVC Sheathed / XLPE power cable of 1.1 KV grade upto 35 Sq.mm size direct in ground i/c excavation,refilling the trench and making good the surface as required.
Supplying and making end termination with brass compression gland and aluminium lugs for 4x16 Sq.mm(28 mm) size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required
Supplying and making end termination with brass compression gland and aluminium lugs for 4x25 Sq.mm(28 mm) size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required
32A Procelain fuse carrier with base
63A Procelain fuse carrier with base
Supply and fixing of 3 star rated 48"/1200mm ceiling fan, in the existing fan hook with necessary connections etc. as required.
Supply and fixing of 50W LED Street light fitting made up of pressure die cast housing with toughened glass and high power LED's with secondary optics and IP 66 protection with necessary connections in the existing pole etc.as required.
Overhauling and servicing of ceiling fan/exhaust fan including disconnection & dismantling, cleaning, replacing worn out parts like bearing, quarter pin, lock nuts, rubber bush, refixing, etc.as required.
Rewinding of ceiling fan including disconnection & dismantling, replacement of faulty bearings, oiling/greasing, etc.as required.
Rewinding of exhaust fan including disconnection & dismantling, replacement of faulty bearings, oiling/greasing, etc.as required.
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.67 MB
BOQ_304577.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid