| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.5 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹50.6 L+₹4.0 L (8.66%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
19 Aug 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
COMMANDER WORKS ENGINEER, DINJAN
COMMANDER WORKS ENGINEER, DINJAN
PROVN OF 02 X GUARD POST AND ALLIED INFRA AT BHALUKUMARA AND PROVN OF GUARD POST WITH ATT TOILET AT ROWRIAH UNDER JORHAT MIL STN
2023_MES_609568_1
84190E8
Open Tender
Civil Works
Item Rate
240 days
GE JORHAT
AS PER TENDER
8 documents required · 8 mandatory
₹500
GE JORHAT
₹86,000
Yes
16 Oct 2023
18 Jul 2023
26 Aug 2023
18 Jul 2023
19 Aug 2023
2 Aug 2023
19 Jul 2023 - 31 Jul 2023
Amount
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or water supply pipes lines etc or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed.
Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed.
M & L for cement concrete in foundation, filling and mass concrete in M15(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
M & L for RCC M25 (Design Mix) using 20 mm nominal size graded crushed stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.
M & L for RCC M25 (Design Mix) using 20 mm nominal size graded crushed stone aggregate as in columns, pillars, piers, posts and struts complete all as specified and as directed.
M & L for RCC M25 (Design Mix) using 20 mm nominal size graded crushed stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5 m span complete all as specified and as directed.
M & L for RCC M25 (Design Mix) using 20 mm nominal size graded crushed stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
M & L for formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished flat surfaces of concrete complete all as specified and as directed.
M & L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for rough finished flat surfaces of concrete complete all as specified and as directed.
M & L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizontal or sloping) for rough finished flat surfaces of concrete complete all as specified and as directed.
M & L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exceeding 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exceeding 10 cm but not exceeding 20 cm wide for rough finished surfaces of concrete complete all as specified and as directed.
M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips and including welding has to be done with minimum 20 cm over lap for new and old of any height complete all as specified and as directed.
M & L for mild steel TMT bars any dia in stirrups, spaces and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed
M & L for mild steel TMT bars 6 mm to 8 mm dia, cut to length, bent to shape required, including hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips and including welding has to be done with minimum 20 cm over lap for new and old of any height. Complete all as specified and as directed.
M & L for brick work with sub class 'B' bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6 complete all as specified and as directed.
Supply only liquid water proofing compound.
S & F for steel work of grade-3 as per IS 10748 in tubular trusses including special shaped washer etc. complete using ERW or HRIW welded tubes conforming to IS 1161: 2014 (Yst 240 Grade) complete all as specified and directed.
M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated corrugated steel sheet, any pattern corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed.
M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated plain steel sheet as per IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in ridge/ valley/ gutter fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed.
M & L for 6 mm thick plain fibre cement flat sheets type B, any category as per IS 14862: 2000 (non-asbestos) building boards, fixed to timber/GI /Aluminium framework with screw complete all as specified as directed by the Engineer-in-Charge.
Providing and fixing inter locking metal grid (anodised aluminium snap grid for false ceiling) of size 605 mm x 605 mm in true horizontal level, hot dipped galvanized steel sections (galvanized @ 120 grams/sqm, both side inclusive) consisting of main “T” runner with suitably spaced joints to get required length and of size 24 mm X 38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm centre to centre and cross “T” of size 24 mm X 28 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “T” at 600 mm centre to centre to form a grid of 1200 mm x 600 mm and secondary cross “T” of length 600 mm and size 24 mm X 28 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200 mm X 600 mm panel to form grids of 600 mm X 600 mm and wall angle of size 24 mm X 24 mm X 0.4 mm. Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27 mm X 37 mm X 25 mm X 1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 mm X 30 mm X 0.8 mm spaced at 1200 mm centre to centre along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications and as directed by Engineer-in-charge.
M & L for preparation of newly plastered surface of wall and applying two coats of oil bound distemper complete all as specified and as directed
M & L for moorum/red bajri filling in floors or pavings, laid in layers not exceeding 15 cm thick, spread, levelled and rammed including watering complete all as specified and as directed.
M & L for cement concrete M7.5 (Nominal Mix) using 40 mm nominal size graded crushed stone aggregate 100 mm thick in sub base for laying tiles, pavings, floorings etc. all as specified and as directed.
M & L for machine cut Kota stone slab flooring 20 to 25 mm thick over cement screed bed of 15 mm thick in cement mortar 1:6, laid and jointed with grey cement slurry, mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
M & L for 20 to 25 mm thick machine cut Kota stone in risers of steps, skirting, dado and pillar laid on backing layer of 10 mm thick in cement mortar 1:3, laid and jointed, pointed with grey cement slurry, mixed with pigments to match the sheds including rubbing and polishing complete all as specified and directed.
Material and labour for plastering 15 mm thick on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:4 finished even and fair complete all as specified and as directed.
Material and labour for plastering 15 mm thick on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:6 finished even and fair complete all as specified and as directed.
M & L for preparation of newly plastered surface of wall and applying two coats cement base paint over one coat of primer complete all as specified and as directed.
M & L for cement concrete M15 (Nominal Mix) using 40 mm nominal size graded crushed stone aggregate in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs, slab staging for water tanks, filling of pressed steel door frame, fixing of hold fasts and the like including weathering, slightly rounded or chamfered angles and throating including necessary formworks complete all as specified and directed by Engineer-in-charge.
S & F 75 mm medium weight mild steel butt hinges made out of cold reduced low carbon steel or hot rolled carbon steel as per IS 1341: 1992 complete all as specified and as directed.
M & L for preparation of new or previously untreated wood or wooden surfaces, of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
M & L for preparing RCC roof surfaces with wire brush drying and cleaning to remove all foreign materials and washing with water to remove loose particle and providing 10 mm thick cement plaster in CM (1:4) using water proofing compound @ 3 % by weight of cement for filling depression if any to receive water proofing treatment and providing APP modified bituminous membrane water proofing membrane with polyester reinforcement and plain finish of 4 mm thick (not less than 5 kg/sqm ± 5% per sqm) consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/Sqm by the same membrane manufacture of density at 25OC, 0.87-0.89 kg/litre and viscosity 70-160 cps over the primer coat the layer of membrane shall be laid using Butane torch application method overlap while torching shall be 75 mm on length and 100 mm width side, all angles & sides should sealed with extra care to ensure full bondage all joints including for applying bituminous aluminium paint @ 0.125 Kg / sqm on finished APP surface complete all as specified and as directed by Engineer-In-charge (Note : WPC shall be measured and paid separately)
M & L for powder coated aluminium frame for doors, windows, ventilators (thickness of powder coating not less than 50 micron) with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed.
S & F hot rolled low tensile structural steel of grade E165 as per IS 15911: 2010 as in chimney bars (straight or camber); bearing bars; tongues or water bars for window frames; window guard bars, plain, let in and fixed independently in wooden frames, L or T section supports for shelves etc. and similar works complete all as specified and as directed.
M & L for powder coated aluminium window and ventilator shutters, side hung type without sash bars, aluminium section (thickness of powder coating not less than 50 micron) weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, powder coated aluminium snap beading, screws, powder coated aluminium fittings such as peg stays 150 mm long (1 no.). hinges type B-21 100 mm long (2 no.) suitable handle (1 no.) complete all as specified
Supply & fix sheet glass, ordinary quality, 5.5 mm thick and glazed with oil putty or fixed with beads in square exceeding 0.5 Sqm in each pane complete all as specified and directed.
S & F galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanised steel wire staples complete all as specified and as directed.
S & F pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.25 mm thickness, size 125 mm X 60 mm, Profile C, single rebate including hinges, mortar guards, lock strike plate, shock absorbers complete all as specified and as directed. Note- PCC filling of hollow section shall be measured and paid seperately.
S & F flush door shutters, 30 mm thick, solid core of block boards construction, MR grade, commercial type with stiles, rails and lipping of timber as given in Group 2A and Group 2B of Annex B of IS 2202 (Part 1): 1999, both sides face panels of plywood as per IS 710: 2010, internally lipped complete all as specified and as directed.
M & L for 30 mm thick, timber species of super group and durability class I as per IS 12896: 1990 and first grade as per IS 1003 (Part-1): 2003, factory made, glazed and skeleton shutters, open rebated and prepared to receive glass, wire gauze, etc. (without sash bar), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc., sizes of members of shutters as specified in SSR Part-I section 8 Clause 8.24 (a) complete all as specified and as directed by the Engineer-in-Charge.
S & F 150 mm size, mild steel barrel tower bolts with mild steel barrel and mild steel bolt, dia of bolt 10 mm, bolt finished bright, other parts finished stove enamelled black complete all as specified and as directed.
S & F mild steel, pressed oval type, 150 mm size, stove enamelled black finish complete all as specified and as directed.
S & F mild steel sliding door bolts, type I (plate type), size 300 mm, stove enamelled black finish to back plate, straps and staple, electroplated finish with nickel and chromium to hasp and bolt, bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified and as directed.
S & F mild steel door spring of rat tail type of size 300 mm, bright finish including roller and roller plate complete all as specified and as directed.
M & L 75 mm thick plain cement concrete M10(Nominal Mix) using 40 mm nominal size graded stone aggregates finished surface even and fair as in plinth protection all as specified and as directed.
Surface dressing not exceeding 15 cm deep in soft/ loose soil complete all as specified and as directed.
Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M35 grade conforming to IS 15658-2006 made by block making machine with strong vibratory compaction, of approved size, design & shape, glossy finish of approved colour, laid in required colour and pattern over 30 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. Note- Rate of Sand filling shall be measured and paid separately.
M & L for sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed.
M & L for cement concrete in surface channels and drains in M10(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
M & L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc. complete all as specified and as directed.
Supply and fix solid PVC door frames of size 50 mm x 47 mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube all as per specification & drawing complete all as specified and directed by Engineer in charge.
Providing and fixing 30 mm thick factory made solid panel PVC door shutter as per IS 15931: 2012 with 19 gauge thickness mild steel tube and tapering 20 mm in 45⁰ angle on both sides forming styles and on the inner side to form top and bottom rail and on both sides to form lock rail complete all as specified and as directed.
S & F 100 mm medium weight mild steel butt hinges made out of cold reduced low carbon steel or hot rolled carbon steel as per IS 1341: 1992 complete all as specified and as directed.
S & F cast aluminium alloy handle, cast type, 150 mm size, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed.
S & F aluminium barrel tower bolts with barrel and bolt of extruded sections of aluminium alloys, 150 mm long, anodized finish not be less than Grade AC 10 of IS 1868 : 1996 with transparent anodic film complete all as specified and as directed.
M & L for non skid, rectified, colour ceramic floor tiles (group B II), 400 mm X 400 mm X 8 mm thick in floors including 15 mm thick screed bed or bedding in cement mortar(1:6) set and jointed in neat cement slurry and pointed in epoxy mortar to match complete all as specified and as directed.
M & L for glazed, colour ceramic wall tiles (group B III), 450 mm X 350 mm X 8 mm thick on vertical surfaces including 10 mm thick backing coat in cement mortar (1:4), set and jointed in neat cement slurry and pointed in epoxy mortar to match all as specified and directed.
Supply only vitreous china wash basin, white, flat back, size 550 mm X 400 mm excluding taps, waste, chain and plug and porcelain stopper but including brackets
S & F 10 litres cap PVC, valve less, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets with 32mm dia PVC pipe 600 mm long complete all as specified and directed
S & F vitreous china squatting pan, 'Orissa" pattern, size 580 mm X 440 mm white with ‘P’ or ‘S' trap, front or back inlet and integral foot rests, any pattern and including fixing bolt, connector to flush pipe, lime concrete bedding and making connections to flush pipe, connector to branch pipe and anti syphonage pipes etc. including sealing the joints and making leak proof using sealant complete all as specified and as directed by Engineer-in-Charge.
M & L for PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and as directed.
S & F unplasticized PVC pipes as per IS 4985: 2000, of class 5, working pressure PN 10 (1 Mpa), plain or socket ended and nominal size 15 including all fittings and fixtures fixed to walls ceiling or in floors with elastomeric sealing ring joints complete all as specified and as directed.
S & F unplasticized PVC pipes as per IS 4985: 2000, of class 5, working pressure PN 10 (1 Mpa), plain or socket ended and nominal size 20 including all fittings and fixtures fixed to walls ceiling or in floors with elastomeric sealing ring joints complete all as specified and as directed.
S & F 15 mm gun metal, globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed to pipe complete
S & F 20 mm gun metal, globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed to pipe complete
S & F 15 mm nominal size, nonrising spindle type fancy concealed stop valves as per IS 8931: 1993 made of cast brass including Knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed.
S & F 15 mm nominal size, nonrising spindle type fancy bib taps as per IS 8931: 1993 made of cast brass including Knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed.
S & F 20 mm nominal size brass float valve, high pressure, with polythene float and flynut, screwed for iron pipe and fixed complete all as specified and as directed.
S & F 15 mm nominal size, nonrising spindle type fancy pillar taps as per IS 8931: 1993, cast copper alloy body with knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed.
S & F 15 mm nominal size, nonrising spindle type fancy stop valves as per IS 8931: 1993 made of cast brass including Knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed.
S & F rotational moulded polyethylene double layer water tanks (vertical cylindrical with close top) as per IS 12701: 1996 of 1000 litres capacity hoisted and fixed in position including provision of 20 mm /15 mm dia medium grade GI pipe for connecting inlet, outlet, over flow and washout pipes all as specified and as directed.
S & F PVC-U, type B as per IS 13592: 2013 single socketed soil waste pipes in any length with rubber ring joints, 110 mm dia, laid in trenches complete all as specified and directed by Engineer- in- charge.
S & F PVC (SWR) bends with inspection door (any angle), 110 mm dia conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge.
S & F PVC Tee(87.5⁰) single, 110 mm dia without inspection door conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge.
Supply and fix PVC (SWR) 'P' trap plain including jointing with adhesive, size 110 mm X 110 mm, water seal minimum 50 mm, complete all as specified and directed by Engineer in charge.
S & F PVC-U, type B as per IS 13592: 2013 single socketed soil waste pipes in any length with rubber ring joints, 75 mm dia, laid in trenches complete all as specified and directed by Engineer- in- charge.
S & F PVC bends without inspection door (any angle), 75 mm dia conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge.
S & F grating doom 125 mm dia with waste hole of PTMT (Minimum weight 40 gms) complete all as specified and as directed.
S & F vitreous china urinals, bowl (flat back) with flushing rim of size 465 mm X 265 mm X 355 mm with side fixing arrangements with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe)complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and union for discharge pipe complete all as specified and as directed.
S & F brass chromium plated tubular towel rail, 20 mm dia, D type, 60 cm long between flanges complete all as specified and as directed.
S & F brass chromium plated shower rose 125 mm size with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and as directed.
M & L for concealed point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the rate quoted by the bidder)
M & L for concealed point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed.(Note: Cost of cutting chase and making good shall be included in the rate quoted by the bidder)
M & L for concealed point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on the same board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the rate quoted by the bidder)
M & L for concealed point wiring for one 3 pin/ 5 pin 15 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 4 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 2.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the rate quoted by the bidder)
Supply and fix metal flush box 1 or 2 module complete all as specified and as directed.
Supply and fix metal flush box 3 module complete all as specified and as directed.
Supply and fix metal flush box 4 module complete all as specified and as directed.
Supply and fix metal flush box modular for 8 module complete all as specified and as directed.
S & F modular white cover plate with frame, 2 modules complete all as specified and as directed.
S & F modular white cover plate with frame, 3 modules complete all as specified and as directed.
S & F modular white cover plate with frame, 4 modules complete all as specified and as directed.
S & F modular white cover plate with frame, 8 modules complete all as specified and as directed.
S & F modular switch, 1 way, 6 A, 1 module complete all as specified and as directed.
S & F modular switch, 1 way, 16 A, 1 module complete all as specified and as directed.
S & F (3 pin and 2 pin) combined modular socket outlets (ISI Marked), 6A, 2 modules, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B complete all as specified and as directed.
S & F (3 pin and 3 pin) with common earthing pins, combined modular socket outlets, 6A & 16A, 2 modules, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B complete all as specified and as directed.
S & F ceiling roses, 6A, 240 V, surface type, intended to support mechanical loads by means of flexible cord, having provision for the connection of switch wiring, screw type terminal, made out of Polyamide or hornbean complete all as specified and as directed.
S & F double door MCB Distribution board of sheet metal enclosure, single pole and neutral, 8 way with 200 Amps rated bus bar, 240 volt, IP42 protection grade and fixed with PVC plug and screws and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
S & F circuit breakers (MCB), two pole with one protected pole (SPN), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current32 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.
S & F circuit breakers (MCB), single pole (SP), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 6A to 32 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
S & F LED tube light fitting 2 feet 10 watts including tube with high power LEDs as light source and electronic driver complete all as specified and as directed.
S & F LED street lights on buildings nominal power 25 Watt LED, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 2500, lumen efficacy of minimum 100 lumens per watt, built-in, isolated electronic LED driver (SMPS based constant current supply) with lower THD, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 80%, beam angle of 120⁰ clear, THD below or less than 15%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with epoxy powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hours of Make mentioned under Appendix "B" with and including fixing at any height on building using 1.5 metre medium grade galvanized iron pipe bracket made of 32 mm nominal bore and necessary nuts, bolts, clamps and concreting and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed.
M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 4.0 mm dia galvanised mild steel wire by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed by the Engineer-in-charge.
Cutting galvanised mild steel pipe of nominal bore 40 mm or 50 mm for alterations or additions (each cut measured) complete all as specified and as directed.
Supplying & laying in trenches 20 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Supplying & laying in trenches 25 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
S & F 25 mm gun metal, globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed to pipe complete
Supply & spreading in trenches sand cushioning to underground cable in trenches including spreading, levelling hand punning down complete all as specified and directed Note:- Depth of sand cushioning will be measured after punning down and levelling the sand properly.
M & L for laying of bricks locally available sub class 'B' bricks (old size) for cable protection cover laid flat and dry in trenches over the cable perpendicular to the direction of cable all as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 4 core, nominal cross sectional area of main conductor 10 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
Supplying and laying reinforced concrete pipes with collars, 150 mm internal diameter, class NP2, laid and jointed with stiff mixture of cement mortar (1:2) complete all as specified and as directed.
M & L for concrete bed to drain pipes of internal diameter 150 mm, in cement concrete M10(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate including packing under and haunching against the sides of pipes complete all as specified and as directed.
M & L for precast cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces fair faces, including chamfers, weatherings, throating etc. and setting in cement mortar (1:4) complete with joints to match complete all as specified and as directed
S & F exhaust fan 300mm sweep 900 rpm 240 V with all accessories complete all as specified and as directed (Make: Crompton Model No. Trans Air 12" - Reversible or equivalent model of Usha/Bajaj/Khaitan/Orient)
S & F ceiling fan, AC, 50 Hz, single phase, 230 V, 1200 mm sweep, minimum air delivery 210 m³ per minute, minimum service value 4 m³ per minute per watt, maximum power input 50 watt, 3 Nos metal blades protected with corrosion resistance paints, class I type with double insulation, insulation class A for temperature rise, with BLDC motor, ISI marked including capacitor to ensure power factor more than 0.9, five star rating as per Bureau of Energy Efficiency complete all as specified and directed by Engineer-in-charge.
M & L for construction of septic tank for 10 users as per drawing No. TD/SZ/504 sheet No. 1/1 including excavation in soft/ loose soil, removal of spoil to 50 metres, lean concrete in M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate, RCC in M25(Design Mix) using 20 mm nominal size graded crushed stone aggregate, brick work in cement mortar (1:4), internal plastering in 20 mm thick in cement mortar (1:3) in two coats of (12 mm + 8 mm) mixed with integral water proofing compound, external plastering in 15 mm thick in cement mortar (1:4) in two coats of (10 mm + 5 mm) mixed with integral water proofing compound upto 15 cm below ground level, flooring/ bedding in M15(Nominal Mix) using 20 mm nominal size graded crushed stone aggregate, precast concrete in M25(Design Mix) using 20 mm nominal size graded crushed stone aggregate, PVC vent pipe and cowl as PVC-U, type B as per IS 13592: 2013 and UPVC as per IS 14735: 1999, TMT bars as specified, cast iron soil waste pipe as per IS 1789: 2002 or IS (3989: 1984, cast iron, pattern 1 footstep as per of IS 5455: 1969 spaced 400 mm horizontally and 400 mm vertically complete all as specified and as directed.
M and L for Construction of Soakage well, excavation in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonary with top ring of M25 concrete including intercepting chamber, and screen chamber made of brickwork in CM 1:4, RCC cover slab in M-25 /SFRC cover, interconnecting pipes of RRC/DWC complete filled with brick bats of size 1.80 M dia X 3.00 M deep complete all as specified and directed
M & L for RCC M15 (Nominal Mix) using 12.5 mm nominal size graded crushed stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
Brickwork, with subclass ‘B’ bricks in one brick thick honey comb work, built in cement mortar of 1:4 complete all as directed
M & L for brick work with sub class 'B' bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and as directed.
Material and labour for plastering 15 mm thick on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:4 finished even and smooth without using extra cement mixing with WPC complete all as specified and as directed. Note- WPC shall be measured and paid separately.
M & L for loose filling with broken stone or boulder aggregates of gauge 80 to 150 mm in soakage pits, soakage wells, on open space complete all as specified and as directed.
M & L for cement concrete in foundation, filling and mass concrete in M10(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
S & F switch, 6A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed.
S & F switch socket combination with (3 pin and 2 pin) combined socket outlets, 6A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B and switch, 6 A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed.
S & F 3 pin socket outlets, 16A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B complete all as specified and as directed.
S & F LED street lights nominal power 35 Watt LED, LED of Make as given in Apps 'B', LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 3500, lumen efficacy of minimum 100 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 80%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with polyester powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hours as per catalogue No. LR02-391-XXX-57-XX of Wipro or equivalent of Make mentioned under Appendix "B" including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed.
S & F Bayonet plastic lamp holder, 2 A, 250 V, ordinary, backplate, non-switched, unenclosed, without T marking, B22d complete all as specified and as directed.
S & F LED Bulb/ lamp non-dimmable type 10 watts with high power LEDs as light source and electronic driver including taking down Unsv LED/CFL light any type, size etc. complete all as specified and as directed.
S & F circuit breakers (MCB), two pole with one protected pole (SPN), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 40 A-63A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.
S & F single door MCB Distribution board of sheet metal enclosure, single pole and neutral, 8 way with 200 Amps rated bus bar, 240 volt, IP42 protection grade and fixed with PVC plug and screws and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
Cutting chases in brick walls to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., not exceeding 10 cm girth and making good the same with cement concrete M15 (Nominal Mix) using 12.5 mm nominal size coarse aggregate or cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 complete all as specified and as directed.
Supplying & laying, repair, in trenches 25 mm nominal bore, light grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
S & F sheet metal enclosure with socket plug top and MCB single pole and neutral enclosure with two pin & earth plug and socket complete with MCB SP 20 Amps 240 volts complete all as specified and as directed.
S & F five star rating water heater (geyser), storage type, stainless steel, 25 litre capacity, 230 volts, AC, single phase complete all as specified and as directed.
MS J B CONSTRUCTION AND CO
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .