Superintending Engineer (D-2) Trans Gomti, LESA, L
Superintending Engineer (D-2) Trans Gomti, LESA, Lucknow
Execution of work of releasing conncection, load increasing/shifting/ construction of line etc to various consumers of Sub-Division-Gomtinagar Vistar in Deposit scheme under jurisdiction of EE, EUDD, Chinhat, LESA, Lucknow.
2022_MVVNL_720978_1
27/EUDC-II/2022-23
Open Tender
Electrical Works
Fixed-rate
30 days
EE EUDD-Chinhat, LESA
As Per Tender Document
2 documents required · 2 mandatory
₹3,540
EE, EUTD II, Lesa, Lucknow
₹27,500
18 Aug 2022
11 Aug 2022
17 Aug 2022
11 Aug 2022
16 Aug 2022
11 Aug 2022
Amount
Dragging, loading, carriage and unloading of following store materials with proper stacking from ESC Daliganj to JE dumps store and from JE dump store to work site with in municipal area.
33/11 KV Power T/F 5 MVA
33/11 KV VCB 800 Amp. 750 MVA
33 KV Lightening Arrestor
33 KV XLPE cable 3x300 sq mm
33 KV C.T 200/100/1A
33 KV control panel Single T/F
11 KV I/C VCB 600/300/5A
11 KV O/G VCB 200/100/5A
11 KV VCB B/C 350 MVA
11 KV XLPE cable 3x300 sqmm
11 KV XLPE cable 3x185 sqmm
11 KV O/Door C/J kit 3x300 sqmm
33 KV O/Door C/J kit 3x300 sqmm
11 KV O/Door C/J kit 3x185 sqmm
11 KV I/Door C/J kit 3x185 sqmm
33 KV S/TH C/J kit 3x300 sqmm
11 KV S/TH C/J kit 3x300 sqmm
TOP Channel
T-OFF Channel
Panther Conductor
11 KV Pilfer Metering Cubical 200/5
11 KV O/D CT PT Metering Unit 200/5
33 KV line Isolator 400 A
Rail 105 lb 9 mtr. Long
M.S. Channel 125x65x6 mm
M.S. Angle 65x65x6 mm
ST Pole 9 M long
MS Round of 32 mm dia
STP 11 m long
Construction of Power T/F plinth suitable for 33/11 KV 5 MVA power T/F of size 4x3x1.3 having 0.4 mtr height above ground level. The work includes excavation of foundation base concreting in cc ratio 1.6 M as 12 1st class brick work in ratio 1.4 with coarse and foundation cc in ratio 1:4:8 using M.S bar of 12 mm dia for reinforcement the work includes laying of 2 no. rail pieces 4 mtr long as per drawing/practice the plinth shall be finished in all respect. (only rail piece and M.S angle provided by the department)
Construction of masonry type plinth of 33 KV VCB of size 1.6x1.6x1 M brick, sand, cement and stone grit including grouting of 4 Nos. foundation volts for erection of 33 KV VCB.
Isolator Structure-Fabrication of Isolator structure minimum 3.5 mtr overall height and 2.5 mtr above ground level as per RESSPO drawing, with help of MS channel 125x65 mm two piecess of MS channel joined to each other by M.S. flat 50x6 mm, diagonally at the interval of 0.5 mtr. and top & bottom of the structure. Grouting of Isolator sructure in CC ( cement, coarse sand and stone grit of 20 mm gauge) including supply of necessary T&P and painting os structure complete. (only M.S. channel and angle provided by the deptt)
Lightning Arrestor/CT structure/PT structure:- Fabrication of lightning arrestor/CT structure/PT structure as per RESSPO drawing with the help of 2 Nos. MS channel 125x65 mm minimum 3.5 mtr. Long grouting 1 mtr deep from ground level in cc in ratio 1:4:8 coplete in all respect.
Fabrication of structures, grouting, plinthing and painting of structures for following equipment.
cable stand
Neutral L Bracket
Mounting of accessories/epuipment on fabricated structure complete work with making proper alignment and tightening the work includes fabrication work if required for proper operation of equipment
33 KV VCB
33 KV lightning Arrestors
Bus/line Isolator
Dragging of following panels( control and feeder pannel) from unloading place upto control room and placement, erection, and grouting commissioning of the same as per RESSPO Norms
Feeder control panel/T/F control pannel
11 KV I/C pannel
11 KV Feeder pannel/BC
Safe dragging of 33KV 5 MVA T/F and its accessories like radiator, conservator tank, exposure event from unloading place up T/F plinth its placement on plinth and with proper alignment approximate 25 mtr. Distance with the help of crane sleepers and man prower etc.
Erection and commissioning of 10 MVA T/F mounting of radiator conservator tank exposure vent etc. filling of T/F oil in radiator conservator tank with complete work as per RESSPO Norms.
Stringing, sagging, jumpering of bus bar grantry with ACSR panther conductor 3 Phase 3wire.
Jumpering complete line bay & T/F bay with ACSR panther Cond. And required clamp with nut & Bolts from 33 KV existing bus bar & 33 KV cable to T/F (with copper L piece) complete work (1 no. line bay &2 no. T/F bay)
Laying of double circuit 11 KV 3x300 sqmm XLPE cable normal soil in between control room and 10 MVA T/F plinth by digging of trench of size 900 mm deep and 500 mm wide including boxing with first class brick and covered with stone slab of size 450x600x50 mm insuring that inter axial spacing between two cable should be 0.2 M to 0.4 as per ISS
Hoisting, jumpering, clamping of 11 KV 3x300 sqmm XLPE cable on cable stand/panel with proper taping with the help of empire tape. PVC tape and conectors.
Construction of cable trench of size 150 mm wide 300 mm deep with brick work along with provision trench cover M.S. Strip at the interval of 0.30 M and M.S. angle at both the edge of the trench.
Construction of cable trench of size 300 mm wide 300 mm deep with brick work along with provision trench cover M.S. Strip at the interval of 0.30 M and M.S. angle at both the edge of the trench.
Construction and fixing of trench cover 0.5 M wide 0.75 mm thick with cement, coarse sand & stone grit in ratio 1:2:4 for covering of cable trench 150 mm wide with provision of M.S angle and MS bar as per RESSPO Norms
Construction and fixing of trench cover 0.5 M wide 0.75 mm thick with cement, coarse sand & stone grit in ratio 1:2:4 for covering of cable trench 300 mm wide with provision of M.S angle and MS bar as per RESSPO Norms
Laying of copper control cable of following sizes its proper dressing, ferruling and connection with system.
4x2.5 sqmm
6x2.5 sqmm
Fixing of cable Tray for support of control cable at 33 KV VCB, CT and in control room.
Earthing of Substation equipment and 10 MVA T/F body and neutral by way of boring and lowering of G.I pipe 1.5" dia up to water level and minimum 20 M deep from the ground level connection in between GI pipe and T/F with GI strip of size 50x6 mm
High pressure testing of cables
Laying of 11 KV XLPE cable
D/C cable laying in normal soil by digging of trench 1050 mm deep, 750 mm wide including supply of required material as fine sand 1st class bricks, stone slab. Inter axial spacing between the two cable should be in between 0.25 m to 0.40m thw two cable should be seprated by a partition of single bricks (All the material required for laying will be supplied by the contractor except 11 KV XLPE cable)
S/C cable laying in normal soil by digging of trench 900 mm deep, 500 mm wide including supply of required material as fine sand, 1st class bricks, stone slab. (All the material required laying will be supplied by the contractor except 11 KV XLPE Cable.
Hoisting of 11 KV XLPE cable on double pole with MS pipe of size 5/6" dia 3 M long including its jumpering complete with clams, nuts and bolts (all material arranged by contractor)
Fabrication & eraection of 11 KV cable exposure type double pole with the provission of cable with fixing of necesory clamps and other acessories like danger board, number plant, barbed wire, 2 no. channels 100x50 mm(160 mm each) 1 no. MS channel 100x50mm (3200 mm lenth ) for supporting the hoisting of cable & poles. its jumpering by single core PVC aluminium cable with proper size Al lug after making three phase bus bar with help of 11 KV pin, pin insulator and PVC cable. (all material arranged by contractor except steel, pole, PVC aluminium cable & insulator) as per RESSPO norms.
Sand filling in control room in cable trench after laying of 11 KV cable
A. A. ENGINEERING CO.
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .