| 1 | L1₹12.8 LAccepted-AOC AT BAGHUABOL CHHAK PO HATATOTA TALCHER ANGUL ODISHA PIN 759100 | ANUGUL | ODISHA | 759100 | ₹12.8 L Quoted ₹10.9 L | L1 | Accepted-AOC technocommercially eligible L1 BIDDER |
| 2 | L2₹13.7 L+₹2.8 L (25.9%)Rejected-Finance AT PO GURUJANG PS TALCHER ANGUL ODISHA PIN 759100 | GURUJANG | ANGUL | ODISHA | 759100 | ₹13.7 L+₹2.8 L (25.9%) | L2 | Rejected-Finance NOT CONSIDERED FOR NOT BEING L1 |
| 3 | Rejected-Technical AT GURUDWARA NEAR UCO BANK PO SOUTH BLANDA TALCHER DIST ANGUL | TALCHER | ANGUL | ODISHA | 759116 | - | - | Rejected-Technical Two nos partial work completion certificate submitted by the bidder which is not acceptable as per clause no. 8.a of NIT. For the work exp. submitted against sl no.1 the total acceptable values is less than the minimum required value for single work. |
Tender Value
₹20.5 L
EMD Value
₹25,600
Closing Date
11 Feb 2025, 5:00 pmClosed
Staff Officer(EnM), Jagannath Area, MCL
Jay Prakash, Staff Officer(EnM), Jagannath Area, MCL PH 06760-269717, 06670-269751(Extn)2023 Fax 06760-269527 E-mail so-enm-jaga.mcl(at)coalindia.in
Day to Day repairing, maintenance and testing of 33 kV Power Transformers , Station Transformer, CT n PT along with 33 kV Primary Breaker n control panel and 6.6kV outgoing feeders for a period of 1 year of Bhubaneswari OCP, Bhubaneswari Area
2025_MCL_327146_1
GM(JA)/EnM/e-Tender/ 24-25/E-725/90 DTD. 28/01/2025
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
TALCHER
As per NIT
5 documents required · 5 mandatory
₹25,600
28 May 2025
29 Jan 2025
13 Feb 2025
30 Jan 2025
11 Feb 2025
30 Jan 2025
30 Jan 2025 - 4 Feb 2025
Amount
Scope of the work:- i) Switchyard Maintenance: Regular checks, cleaning, and adjustments for switchyard equipment . ii) Power Transformer Maintenance: Comprehensive maintenance for power transformers. iii) 33kV VCB and CR Panel Maintenance: Inspections, lubrication, and replacement of faulty components. 6.6kV VCB Maintenance: Similar to the 33kV VCB maintenance. iv) Battery Bank Maintenance: Ensuring battery health and backup capacity. v) NGR maintenance: Ensuring NGR health and proper earthing.
For 33 kV Power Transformer, Station Transformer, CT & PT
Bushing Stud
Rubber Bush
Bushing Gaskets
Neoprene type Oil gasket/ Cork sheet, Size:- 2ft X 3ft X 10mm
WTI / OTI meter
Oil cooled out door 33 kV Current Transformer of ratio 200 /1,3 core Burden 30 VA
Single phase, oil filled, outdoor type VT with terminal connector suitable for Al. tube/conductor with marshalling box etc., 33 kV/√3 / 110 V/√3 - 110 V/√3
Water proof ABS terminal box (size- 200 x 200 x 100 mm) with provision for control cable through in & out.
Brass Nuts, Bolts, Washer etc
Nuts, Bolts, Washer etc
Buchholz Relay
PRD (Pressure Relief Device)
Silica Gel
33KV Isolator male contact 2.5mm
MOG (Magnetic Oil level Gauge)
Repairing, Maintenenance, Providing & Fixing cost
Cleaning and maintenance of transformer body with oil drainge, oil filling and replacement with fixing of Bushing studs, rubber bushes, Bushing Gaskets and oil Gaskets of Top cover plate etc as required along with fitment of supplied items.
Transformer oil filteration including labour cost & oil filteration machine charges.
Fixing of oil cooled out door 33 kV Current Transformer & Potential Transformers over the structures of substation with necessary terminal connection along with dismantling of defunct CT & PT.
Supplying and erection of single piece nonlinear resistor type lightning arrestor suitable for 3 wire, 33 KV overhead lines with rated voltage 30 KV (rms) with a nominal discharge current rating of 10 KA (station class) and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required.
Wiring of control circuit unit with 2.5 sqmm PVC insulated copper condoctor (With all necessary items of required grade such as terminal block, Copper links, ferulle, etc.)
For 33 kV CR panel and 6.6 KV outgoing feeder panel, 1250 Amp VCB
Coil Support
Tripping / Operating coil(110-132V DC)
Closing Coil (110-132V DC)
Auxilary contactor,2NO+2NC
Fuse base and carrier upto 40 Amp
HT HRC Fuse
KWH meter
Power factor meter
KVAR meter
KW meter
Space Heater with Thermostate
Motor 230-250V dc-ac
Digital Ammeter/Voltmeter
Indication Lamp
Breaker Control Switch(T-N-C)
Push botton
Earth Leakage Relay 1-8 Amp,0.15-.3sec
Core balance current Transformer
Support Insulator
Cable gland cone brass
CT, 1000/5/5 A,12 KV,STC 26.2KA
PT 6.6 KV/110V,100VA/Ph,3Ph PT
GOAB Interlocking box
6 amps. to 32 amps. ratings , SP MCB, “C” curve,10 KA breaking capacity
Differntial & REF Relay for 10MVA, 33KV/6.6KV Transformer
Epoxy resin cast 11kV Busbar Spout 3 phase
Transformer, 240/24V AC,50VA
Labour Cost for repairing & maintenance of 33 kV/6.6KV Primary Breaker & Control Panel,6.6kV Incomer, feeder and NGR
Dismantling,cleaning.maintenance of 33 kV VCB & checking of its moving & fixed contacts,incoming and outgoing Bus Bar connection with overhauling of its spares for smooth operation etc as required.
Minor repairing work of 33kV VCB, Testing of control Circuit and protective devices along with replacement of defunct spares for smooth working of VCB.
Dismantling,cleaning.maintenance of 6.6 kV VCB & checking of its moving & fixed contacts,incoming and outgoing Bus Bar connection with overhauling of its spares for smooth operation etc as required.
Testing, cleaning of Control circuit of NGR panel along with replacement of defunct spares for smooth working of NGR
Total impact of GST for the purpose of CTC
M/S BHARAT ENGINEERING (BID ID -1125944)
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .