Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹34.4 L+₹1.4 L (4.36%)Rejected-AOC 37 222 BUNDU KATRA AGRA UP | AGRA | UP | L2 | Rejected-AOC L2 | |
| 3 | L3₹38.9 L+₹6.0 L (18.2%)Rejected-AOC NO 9 BYRAVESHWARA INDUSTRIAL ESTATE ANDRAHALLI MAIN ROAD NEAR PEENYA 2ND STAGE BENGALURU 560 091 | BENGALURU URBAN | KARNATAKA | 560091 | L3 | Rejected-AOC L3 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
8 Dec 2022, 6:00 pmClosed
GE Bharatpur
Kanjoli line Bharatpur
Repair/maintenance of DG Set, pump sets, cleaning of O/H tanks, U/G sumps, open wells and repair to MES installations at RMS Dholpur
2022_MES_561958_1
8207/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE Bharatpur
as per tender document
6 documents required · 6 mandatory
₹500
GE Bharatpur
₹80,000
Yes
6 Jan 2023
7 Nov 2022
14 Dec 2022
7 Nov 2022
8 Dec 2022
25 Nov 2022
8 Nov 2022 - 19 Nov 2022
Amount
Excavation in trenches not exc 1.5 m in depth and not exc 1.5 m wide for taking out/laying LT UG cable, Stay wire and LT pole etc and getting out in hard/disintegrated layer complete all specified/directed
Removing excavated soil at a distance not exc 50 m and deposited where directed complete all as directed
Returning,filling in including spreading, leveling, watering and well ramming in layers not exc 25 cm complete all as directed
Supply & laying sub class B bricks, locally available common burnt bricks suitable for LT cable protection cover all as specified and as directed by Engineer-in-Charge
M &L for dry sand cushioning for protection of under ground cables (8CM before laying the cable and 15CM after laying the cable in trenches) complete all as specified and directed .
M&L for PCC (1:2:4) type B2 with using 40mm graded aggregate as in foundation and mass filling concrete for LT panel boards and in addition foundation to support of pipe line near pump house and india lake area and where ever directed including dismentling of old PCC as specified and directed by Engr-in-Charge .
Supply, laying and testing LT cable XLPE insulated,screened, PVC bedded, galvanised steel strip or wire armoured,electric power cable (heavy duty) with stranded aluminium conductor 1100V grade , 3 1/2 core of size 70 Sqmm, including taking out of old UNSV cable from trench/floor etc all as specified and as directed by Engineer-in-Charge.
Supply, laying and testing cable XLPE insulated, screened PVC bedded, galvanised steel stripped or wire armoured electric cable heavy duty with stranded aluminium conductor , 1100Volts grade of size 16 Sqmm 4 core including taking out of old unserviceable cable from trenches/ floor etc. all as specified and directed by Engineer in Charge.
Supply, laying, testing & commissioning LT XLPE insulated armoured (heavy duty) electric cable of single core 95 Sqmm with stranded copper conductor 1100 volts grade (ISI marked) & laid in trenches/pipes or fixed on pole from transformer to panel including taking out of old unserviceable cable from trenches /floor etc complete all as specified and directed
M&L for loose filling / hardcore packing of stone aggregates of guage n.exc 63mm boulders in switch yard for arresting fire and arc , upto thickness n.exc 15cm, all as specified and as directed by Engineer-in-Charge.
M&L stay wire complete length 7/4.0mm Grade 2 with securing and clamping on stay assembly all as specified and directed by Engineer in Charge
M&L stay assembly complete set of size 16mm rod with accessories as shown electrical plate no.1, incl loop type insulator stay clamp etc all as specified and directed by Engineer in Charge.
S&F Anti climbing devices, comprising 2.24mm dia galvanised steel 2 strand barbed wire with 2.00mm dia barbs wrapped spirally round poles, to a length of 0.5 to 1.0 mtr clamped and properly secured or as ordered all as specified and as directed by Engineer-in-Charge.
M&L for Danger Notice Plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters figures and conventional skull and bones in singnal red colour and fixed with MS clamps, bolts and nuts of approved size of 25x20cm all as specified and as directed by Engineer-in-Charge.
M&L for GI guard wire 4mm dia including making cradles etc over the bldg and road crossings/nalah crossings from Kesarbagh to Gundrai OH line etc all as specified and as directed by Engineer-in-Charge.
M&L for rewinding of 7.5/5 HP monoblock pumpset installed at Gundrai Sump including taking out from mounting , disconnecting all electrical and water connections , transportation to workshop and installing back after rewinding, replacing defective capacitor, impeller housing, bearing, GI fittings of 20mm dia all kind, lathe work if required, testing as per the standard Govt procedure after installation etc all as specified and as directed by Engineer-in-Charge.
M&L for cross arms 'C' shaped or angle type as per site requirement, bracings, supports, clamps and back plates etc fabricated from structural steel section incl nuts bolts and washers, welding, bending, cold or hot, drilling holes for bolts, in any shape and any length to fix on two pole structure or any single pole at any height and any location as per site reqiuirement complete all as specified and directed by Engineer in Charge
Taking down old ACSR conductor from the insulators fitted on LT poles of any size, UNSV channels/cross arms etc without damaging any assets existing near the well no 1 at Gundrai forest all as specified and as directed by Engineer-in-Charge
M&L for stringing ACSR conductor on poles 3 runs of wiesel and 3 runs of mink or as per site requirement with permissible sag as per IS rules etc all as specified and directed by Engineer in Charge.
M&L for painting with two coat of aluminium paint over one coat of metallic primer on Steel tubular pole and cross arms any size and height including preparation of metallic surface with sand papers complete all as specified and as directed by Engineer-in-Charge. Note: (i) Location - Gundrai to Kesarbagh area. (ii) During school hours Shutdown shall be given after getting approval from the Stn I/C officer and during holidays shutdown shall be given after consulting with Engineer-in-Charge. (iii) Continuous shutdown more than 4Hrs shall not be given in a single day because of water supply constraints. (iv) All kind of safety deivces, vehicles and ladders shall be arranged by the contractor at site and rates deemend to be included in quoted rate.
S&F glow sign board of 2 mm thick white polished transparent acrylic cover, unbreakable, heat resistive etc including M&L of steel fabrication of angles and supports of thickness not less than 2mm thick (thickness shall be variable upto 5mm as per site conditions) rectangular box type of size minimum 180cm x 90cm x 20cm thick, computerised letter of blue colour of size 30cm high and 3 to 5 cm width or small as per site requirement stick permanently with glue on backside, including all kind of securing, welding, assembling with proper alignment and height with fine look, including PCC work, excavation if required, LED tube light fittings 1x 20 Watt, including connecting wires and switch independent one way 5 Amp with well finish of weather proof paint suitable for exposing at all weathers including taking down of old UNSV complete all as specified and as directed by Engineer-in-Charge.
S&F glow sign board of 2mm thick white polished transparent acrylic cover, unbreakable, heat resistive etc including M&L of steel fabrication of angles and supports of thickness not less than 2mm thick (thickness shall be variable upto 5mm as per site conditions) rectangular box type of size minimum 400cm x 60cm x 20cm thick, computerised letter of blue colour of size 30cm high and 3 to 5cm width or small as per site requirement stick permanently with glue on backside, including all kind of securing, welding, assembling with proper allignment and height with fine look, PCC, cement work, excavation if required, LED tube light fittings 1x 20Watt, including connecting wires and switch independent one way 5Amp with well finish of weather proof suitable for exposing at all weathers including taking down of old UNSV complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement LED street light fittings with excellent thermal management of 90 Watt IP-65 with complete accessories on existing brackets fixed on MES installation bldgs at Gundrai and Kesarbagh palace including taking down the old UNSV one and connecting up the lights to the nearest point by using 1sqmm copper wire 2 run and replacing the brackets and clamps if required , drilling holes on stone masonry all as specified and as directed by Engineer-in-Charge. Make Havells, Cat part No LHETBXU7PN6J090 or equivalent catpart of Philips/Bajaj.
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete fittings such as switches, ceiling roses, pendents, regulators, sockets etc removing materials for taking credit and making good disturbed surfaces of wall, floor & ceiling etc complete all as specified and directed.
Taking down old U/S rusted main switch/DB of any size capacity and make complete all as specified and directed..
Taking down old U/S sub main wiring of any size & make complete all as specified and directed..
M&L point wiring complete with 1.5 Sqmm 02 x single core multistranded copper conductor of 1100 volts grade PVC pre insulated FRLS and unsheathed cable enclosed in and including PVC casing and caping double locked box type with all PVC accessories such as Tee, bend, collar, elbow, square junction box etc fixed on the surface of wall/ceiling by means of PVCsleevel/dash fastners with cadmium plated screws including suitable size of PVC boards for mounting fittings like switches, sockets, fan regulator etc including 1.5 Sqmm insulated but unsheathed copper earth continuity conductor to common earth and connedcted to earth dolly complete all as specified and directed for the following :-
(a) One light point controlled by one one way switch.
(b) One fan point controlled by one one way switch.
(c) One 3 pin 6 Amp socket point outlet on the same board with other switches
(d) One 3 pin 6 Amp socket point outlet on the independent board
All as per item No 27 above but with multi stranded copper conductor cable 2.5 Sqmm size for 3 pin 16 Amps socket point outlet on independent board including 2.5 Sqmm copper cable PVC insulated FRLS unsheathed copper continuous earth wire including connecting to common earth dolly complete all as specified and directed.
S&F socket outlet 2 in 1, 5pin, 6 Amps multi purpose flush type 230 volt complete all as specified and directed.T
S&F switch socket combination 2 in 1, 16 Amp flush type multi purpose 230 volt complete all as specified and directed.
S&F switch piano flush button single pole one way 6 Amps 230 volt grade complete all as specified and directed.
S&F ceiling rose surface bakelite 50 x 40 mm three terminal ISI marked including suitable size of PVC board complete all as specified and directed.
S&F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc as required complete all as specified and directed.
M&L submain wiring complete with 4 Sqmm single core multi standred PVC insulated and sheathed cable FRLS copper conductor two runs and one run of 4 Sqmm copper cable for earth continuity conductor in and including drawn through PVC casing capping PVC conduit/sleeves with all PVC accessories fixed on wall, floor/ceiling etc complete all as specified and directed..
M & L for distribution board factory made and tested made of sheet metal enclosure powder coated suitable for mounting the MCB 240 volt of the following DBs :-Makes -L & T / Legrand.
(a) 8 way SPN with200 Amp rated busbar 240 volts (double door type).
(b) 4 Way SPN with 200Amp rated busbar 240V (Double door type)
S&F MCB 240 volts 10 KA, rupturing capacity fixed in DB's of the undermentioned type and rating. Make : L&T/ Legrand.
(a) MCB SP 240 volts 10-40 Amps
(b) MCB SPN 240 volts, 40 Amps
S&F in repair tube light frame slim type with Photon Ultra LED glass crystal tube rod 20 Watt suitable for replacing 1200m length LED tube rod, prewired with complete accessories suitable for fixing on wall/ceiling complete ,both tube rod and fitting are seperate all as specified and as directed by Engineer-in-Charge. Make - Havells Cat Part No REGALBATTENT8UPTO1X22WSSBSWH or equivalent in Phillips/Bajaj/CG
M&L batten/angle holder insulated with back plate including suitable size of PVC round block complete all as specified and directed.
S&F in repair LED light fitting 1 x 10 W 230 volts bulk head energy saving luminaries with LED Bulbs etc complete with all accessories duly prewied and including connecting up with twin core twisted flexible copper conductor cable of suitable size 230 volts 50 Hz suitable for fixing on wall/surface mounted all as directed by Engineer-in- Charge. Make -Havells, CAT Part No RUGBYNEONFT10WLED86CSSYMTOPC or equivalent in Bajaj/Phillips.
M & L earthing complete with GI plate electrode 60cm x 60cm x 6 mm thick buried directly in ground earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5m below ground level, connecting to the GI earth strip 32x 6 mm by means of nuts, bolts, check nuts and washer etc of galvanised iron and earth lead protected by provision of GI pipe medium grade 40mm bore from earth elelctrode to test point incl provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone agagregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM sheet (weight not less than 4Kg/Sqm) and frame of angle iron 25 x 25 x 6mm with lugs 2 Nos and with 8mm dia MS bar handle made to shape, GI pipe medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling test point with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning in and removal of surplus soil to a distance not exceeding 50mtr, complete all as specified in electrical plate No 3 of SSR Part I and connection to earth test point including testing on complete all as specified and directed. Note :- The cost of 7.5m long galvanised iron earth strip of 32 x 6mm size and protection pipe of 40mm bore GI light grade is deemed to be included in quoted unit rate.
Material and labour for renewal of Chemical Earthing complete with copper earth plate electrode of size 900x600x3mm thick buried directly in ground (earth pit should not less than 4 mtr deep below normal ground level ) with top edge of the plate not less than 2.95 mtr deep below normal ground connected to and included copper earth strip 32mmx 6mm by means of copper bolts nuts check nuts and washer returning and filling the pits with excaviated vsoil mixing with charcoal 250 kg crystal salt 200 kg magnisiun sulphate of 100 kg and vegitable soil all around the plate up to 350 mm above from top edge of plate and balence portion filling with excaviated soil in layers not exc 25 mm thick 25 mm bore galvanised iron medium grade watering pipe up to top of plate 50mm bore galvanised iron light grade pipe for earth strip protection including all excavation earth work in any type of soil pcc 1;3;6 type c1 ....for chamber of internal size 300mmx 300mmx300mm with 120mm thick wall and 700mmx700mmx150mm thick bed concreat RCC 1:2:4 ,type b1 for precast chamber cover 50mm thick reinforced with welded steel wire fabric orxPM jali (weight not less than 4.00 kg/sqmm) ,funnel,with wire mesh complete all as specied and directed. Note (i) Quoted rate shall be deemed to include for earth strip with protection pipe up to 7.5 M length
Cutting anxious green growth / vegetation growth from root for cleaning out the area around OH tank / pump house No-1, 2 & 3 at Gundrai and kesharbagh sbustation, Kesarbagh sump house and at ground level by cutting up root, un- wanted plants / bushes and removal the same to a distance not less than 50 mtr directed complete all as specified and directed by engineer -in -charge,\. Note: (i) Rate deemed to be included Cutting T&P, transporting/disposal/dumping away from the site as per the laid down procedure of waste management system shall be considered with this item rate. (ii) Entire site shall not be given in one time. Area for cleaning shall be given to the contractor on requirement basis as per the site conditions and growth rate of bushes and grass etc. The area shall be divided into several parts and shall be directed to the contractor when cleaning is required at site.
Supply and Install outdoor type LT feeder pillar box cubical type enclosure size 800mm x 600mm x 300mm, self standing, duly powder coated, front openable Made outof MS sheet ,3.15 mm thick , factory made, with 4 x 400Amp aluminium bus bar for outgoing provided with 4 x branch connection by using nuts and bolts and lugs, including taking out of old existing panel /pole box comprising the following in incoming: (a) MCCB 4 pole TPN, 100Amps capacity, 36KA breaking capacity, 415V,adjustable thermal & fixed magnetic setting, Make Havells - 01No. (b) Busbar 4 pole 200 Amp - 1 set
Supply and fix on load change over switch 415 v in sheet metel enclouser 4 pole of capacity 160 amp all as specified and directed by engineer -in-charge
Supply and fix on load change over switch 415 v in sheet metel enclouser 4 pole of capacity 200 amp all as specified and directed by engineer -in-charge
Supply and fixing in replacement of sluice valves of cast iron body with forged brass spindle, class PN 1.6 and cast iron wheel head, both ends flanged, IS-1486 marked complete with neoprene rubber gasket joints, nuts, bolts (high tensile), and washers etc all as specified and directed (Make : Upadhyay/ Kejriwal iron and steel works/ Kirlosker/Bir/L&T) of following size:-
(a) 150mm bore flanged end.
(b) 100mm bore flanged end.
Supply and fixing in replacement of non return valve, flanged ends PN 1.0 ISI marked of 100mm bore (Make : Upadhyay/ Kejriwal Iron and steel work/ Kirloskar/ Bir/L&T) complete all as specified and directed.
Supply and fixing in replacement of non return valve, flanged ends PN 1.0 ISI marked of 80mm bore (Make : Upadhyay/ Kejriwal Iron and steel work/ Kirloskar/ Bir/L&T) complete all as specified and directed.
Supply and laying 3 layer PP-R pipes SDR 7.4 UV stablised and antimicrobial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings of all size as per ground requirement laid in trenches including all fitting complete all as specified and directed.Make: SFMC/ SUPREME or Equivalent Make for the following size of pipes :-
PP-R pipe 50 mm outer dia .
PP-R pipe 32 mm outer dia .
PP-R pipe 25 mm outer dia .
PP-R pipe 20 mm outer dia .
Supply and fixing in repair of GI water tubing IS-1239 marked, medium grade, in replacement including all necessary pipe fittings laid in trenches, on wall, under floor, under road on same or new route and making good the disturbed portion as existing and including taking down of old unserviciable pipe of the following sizes :- Note :-excavation earth work will be measured and paid saperatly.
(a) 15mm bore
(b) 20mm bore
(c) 25mm bore
(d) 40mm bore
S & F for MCCBs without damaging the LT panel board or any assets associated with the installation including taking out old Existing U/S MCCB from LT panels/ Feeder piller of following capacity complete all as specified and directed
(a) MCCB 4 pole TPN, 160Amps capacity, 36KA breaking capacity, 415V,adjustable thermal & fixed magnetic setting, Ics = Icu,
(b) MCCB 4 pole TPN, 200Amps capacity, 36KA breaking capacity, 415V,adjustable thermal & fixed magnetic setting, Ics = Icu,
(c) MCCB 4 pole TPN, 400 Amps capacity, 36KA breaking capacity, 415V,adjustable thermal & fixed magnetic setting, Ics = Icu,
(d) MCCB 3 pole TP, 63 Amps capacity, 16KA breaking capacity, 415V,adjustable thermal & fixed magnetic setting, Ics = Icu,
(e) MCCB 3 pole TP,100Amps capacity, 16KA breaking capacity, 415V,adjustable thermal & fixed magnetic setting, Ics = Icu,
Material and labour for Rotational moulded polyethylene water storage tanks 1000Ltr (cylindrical vertical with closed top) hoisted and fixed in position with float valve all as specified in SSR Part I, including taking out of existing complete all as specified and directed.
supply and fix Rubber mat of 1 meter x 2 meter x 10 mm all as specified and directed by engineer-in-charge
Supply and fix electric rubber hand gloves (two glooves for each person)11KV all as specified and as directed
Supply and fix AMF panel complete with power contactor 125 amp ---03 Nos. with coppr busbar of 200 Amp capacity ------04 Nos. and AMF relay complete indicating lamp, amp meter, volt meter and CT including sutiable battery accessories and with I/C MCCB 125 amp-02 nos all as specified and directed by engineer -in-charge
Supply, connect, fixing and testing of submersible cables copper conductor PVC insulated over all sheathed flat flexible, ISI marked - Conforming to IS 694,1100 volts grade complete including taking down old u/s submersible cable of following size.
(a) 10 sqmm 3 core
(b) 16 sqmm 3 core
Servicing of industrial RO Plant installed at academic complex including back washing, cleansing the filter medium, resetting all TDS upto the recommended level by PHED, checking all valves, servicing the turbo jet motor for raw water, checking and tighting all mounting brackets, nuts. Bolts etc. removing fungus by cleaning of raw water and filtered water storage tank complete all as specified and as directed by Engineer-in-Charge. Note: (i) Technician should be hired from reputed company of the RO plant. (ii) No extra allowance shall be be given to the technician. (iii) Coneyance must be ensured by the contractor only. No vehicle shall be provided for the conveyance of the technician by MES.
S&F for replacement of the following spare parts of RO plant of capacity 40 to 200LPH installed at academic complex complete all as specified and as directed.
(a) Primary sediment cartridge Filter
(b) Secondary sediment cartridge Filter
(c) RO membrane as per the existing make and model suitable for 200LPH capacity
(d) Rewinding of raw water motor and servicing of pumpassembly of capacity 2HP
(e) PCB control panel with LED display and mounting accessories and testing etc
S & F in repair for DOL Starter of capacity 5HP suitable for three phase 3HP motors complete with on off push buttons and over current relay complete all as specified and as directed.
M&L for rewinding 5HP motor of lifting pumpset by using super enamelled copper conductor wire solid in nature, grade 1 quality, incl dismantling/assembling and transporting etc. and refixing after repairing and replacing of UNSV parts such as housing/nuts bolts etc complete all as specified and as directed.
M&L for rewinding and repair of burnt out 0.5HP pump from the mounting of lower tank incl transporting to workshop, transporting back to its original location and mounting, refitting, testing etc complete all as spefified and directed by Engr-in-Charge. Note: rate including replacement of all kind of spare parts such as ball bearing, impeller housing, diffuser, valute casing and delivery assembly, suction assembly , all kind of lathe works deemed to be included in each job complete all as specified and directed.
supply and fix of ^lithium based Energy Efficient Integrated solar street light of 32 watt ^ in single FRP body with duly polyurethane coating(camouflage colour),encases with monocrystalline solar PV panel of 65-67 Wp ,lithium battery 11.1/12.8 v 33 AH with inbuilt BMS IP 65 high brightness W-LED (160/180 lm /watt) lamp with aluminium reflector for better light distrubtion CRI>70 colour temperature 5700-6500K . microcontroller basedcharge controller cum driver automatic diming function (frist four hour at full brightness and rest of the time at lower light level with PIR motion sensor dusk to dawn operation sutiable to working temperature -10 to 55 C .weight not more than 14-16 kg with adjustiable MS clamp sutiable for pole wall mounting etc complete as requirer protection-short circuit overload reverse polarity and battery protection firm should provide vital parameter test report from NABL accredited lab and should be made in india with CE and ROHS complaint complete all as specified and as directed.
Taking out submersible pump set of capacity 40HP/20HP 3 Phase 415 volt AC supply alongwith column pipes from the bore well by disconnecting electric connection, disconnecting the motor from pump dismantling the motor & over hauling the same by repairing/ replacing defective part as ordered & re-assembling including M&L for replacing worn- out nuts bolts washers complete, connecting /coupling the motor with pump & with column pipes & lowering the same after repairing, making the connecion complete all as directed by Engr-in-Charge. Note: Spares shall be measured & paid separately for dismantling of pump set partly or full shall be paid accordingly.
Supply only spare parts for above 40HP submersible pump at item No 63 above complete all as specified and as directed
(a) Hook bolt
(b) Motor Bush
(c) Seal
(d) Rubber Bush
(e) SS Bush
(f) Stud with nuts & bolts
(g)Neck Ring
(h) Impeller
(j) Top/Bottom bearing bush
(k) SS Rooter sleeves
(l) Thrust Plate
(m) SS shaft
(n) Bowl Bush
(o) Diffuser CI/Steel
M&L for rewinding the submersible Motor 40HP/20HP with super enamaled copper winding wire of suitable gauge & superior class of insulation including insulation paper sleeves thimbles etc & testing.
Cleaning of RCC overhead reservoir of 75,000 GLN capacity of 18 Mtr staging including draining out water. Removing, Mud, Slit/dust from Tank. Washing & rubbing with gunny bags & cleaning with fresh water & Bleaching powder including writing the date of cleaning etc by synthetic enamal paint all as directed by Engr-in-Charge. (a) All necessary ladder and scaffolding arrangement shall be made by the contractor. (b) All kind of safety equipments shall be arranged at site by the contractor. (c) In case of damage of any outlet pipeline/control valves during operation shall be borne by the contractor (d) Disturbed portion if any shall be made good as per existing by the contractor
Cleaning of Masonry /RCC under ground sump of 50000 GLN capacity, Located at Gundrai pump house No 1, including the following works: (i) draining out water with the help of monoblock pumpset (pumpset shall be managed by the contractor) (ii) Removing, Mud, Slit/dust from sump by manually & rubbing & cleaning with gunny bags etc (iii) washing with fresh water & Bleaching powder two times (iv) writing the date of cleaning etc by synthetic enamel paint (v) applying two coat of light blue colour synthetic enamel wall paint internally upto 84SQM on inside of floor and all walls all as directed by Engr-in-Charge.
Cleaning of Masonry /RCC under ground sump of 25000 LTR capacity loacted at Cadets hostel area including the following works: (i) draining out water with the help of monoblock pumpset (pumpset shall be managed by the contractor) (ii) Removing, Mud, Slit/dust from sump by manually & rubbing & cleaning with gunny bags etc (iii) washing with fresh water & Bleaching powder two times (iv) writing the date of cleaning etc by synthetic enamel paint (v) applying two coat of white wash.
Cleaning of Masonry /RCC under ground sump of 25000 GLN capacity loacted at Kesarbagh Sump House area including the following works: (i) draining out water with the help of monoblock pumpset (pumpset shall be managed by the contractor) (ii) Removing, Mud, Slit/dust from sump by manually & rubbing & cleaning with gunny bags etc (iii) washing with fresh water & Bleaching powder two times (iv) writing the date of cleaning etc by synthetic enamel paint (v) applying two coat of white wash.
Dismantling electric motor of centrifugal pump 3 phase for 440 volt 30 HP and rewinding of motor with super enameled copper wire of same guage & turn including material, varnishing, re-assembling, testing & commissioning /complete all as directed by Engr-in-Charge Note: Spares shall be measured & paid separately for dismantling of pump set partially or complete shall be paid accordingly.
Supply only spare parts for above Centrifugal Pump of 30 HP at item No 70 complete all as specified and as directed
(a) Ball bearing SKF/NBC (6309)
(b) Pump shaft with Key
(c) Coupling Key
(d) Gland Plate (Set of two)
(e) Suction/Discharge stud/Nuts/ Bolts
(f) Gland Bush (Gun metal)
(g) Coupling rubberised
(h) Foot valve 80mm GI or CI heavy grade as per existing
M&L for rewinding the Submersible pump Motor 5HP/7.5HP with super enamaled copper winding wire of suitable guage & class of insulation including insulation paper sleeves thimbles etc & testing complete all as specified and as directed
Supply & fixing MCCB 125Amp Four Pole (25KA) adjustable type in existing panel board complete all as specified and as directed
Servicing of DG set 82.5KVA and 63 KVA water/air cooled (Kirloskar) by unscrewing nuts, bolts and servicing of DG set with checking, draining and changing of Engine oil and Coolant, checking and changing of V-belts, greasing and oiling of all relevant parts and topping up, Cleaning the inner body of Fuel tank and Radiator etc by removing sludge etc and reassembling the DG set after repair and replacement of unserviceable parts of DG set including repair of control panel, opening of alternator, water pump, starter motor for cleaning, servicing and refixing. Checking and servicing of Battery and testing complete in all respect all as directed by Engr-in-charge. Note: Spares shall be measured & paid separately for dismantling of DG set partly or full shall be paid accordingly.
Supply only following spare parts for item above DG Set item No. 74 complete all as specified and as directed :-
(a) Air cleaner element
(b) Water hoses including clamps complete all as specified.
(c) Fuel filter element.
(d) Lubrication oil filter
(e) Fuel Pipe
(f) Piston & Rings
(g) Fan belt.
(h) Head Gasket
(j) RC Joint, Set of O Rings, Set of Joints
(k) Valve Pair, Valve seal and Valve guide
(l) Battery 150 AH (Type Flat Bed, Maintenance Free) Make :- Exide/ Amaron/ Luminous
(m) Oil Pipes including clamps complete all as specified
(n) coolant in one/two ltrs packing complete all as specified and directed by Engineer-in-Charge.
(o) Supply only distilled water in one/two ltrs packing.
Supply & filling oil of recommended grade (DF-4, 15 W 40) Make Servo.(in 5 Litres Can) Required 20 Litres all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair of the following spare parts of Fully Automatic Star Delta Starters:
(a) Contactor switch 25Amp capacity, with 380-415V coil, ML model of L&T or equivalent
(b) Contactor switch 40Amp capacity, with 380-415V coil, ML model of L&T or equivalent
(c) Contactor switch 70Amp capacity, with 380-415V coil, ML model of L&T or equivalent
(d) Start/Stop push button toggle switch
(e) Starter relay 415V, 40Amp or above upto existing capcity range
(f) Multi controller/single phase preventer & timer switch relay in single box capacity ranging from 7.5HP to 40HP make L&T, cat part No CS94824D000
(g) GI Foot valve 40mm heavy type
(h) Copper lugs of size 16 to 25sqmm
(j) Aluminium lugs of size 50 to 120sqmm
M&L for rewinding of monoblock pumpset installed at Cadets hostel area after dismantling all connections and transporting to workshop and replaceing spares, cutting burnt out winding and rewinding suitable copper super enamelled conductors on primary stator and re-installing at existing loaction all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement of old unsv Direct Online Starter of capacity 7.5HP suitable for monoblock pumpsets installed at cadets hostel area complete all as specified and as directed by Engineer-in-Charge. Make L&T, cat part No SS96211
S&F in repair for fully automatic star delta starter comprising of voltmeter 0-500 V and ammeter 0-100 Amps, single phase preventor, over load relay and timer housed in single MS sheet powder coated enclosure suitable for up to 40 HP and above 70 amp submersible motor pump including first filling of oil in oil chamber (If Required) and testing complete (Make : L&T, Cat Part no CS90908) or equivalent Cat Part of approved make.
S&F in repair fully automatic star delta starter comprising of voltmeter 0-500 V and ammeter 0-100 Amps, single phase preventor, over load relay and timer housed in single MS sheet powder coated enclosure suitable for up to 10 HP (Rating / Capacity of starter should be 1.5 times more than that of Submersible Motor pump) submersible motor pump including first filling of oil in oil chamber (If Required) and testing complete (Make :L&T, Cat Part No SS95983) or equivalent Cat Part of other approved make.
Labour only for servicing APFC panel board and checking all the contact terminals and capacitors, repairing the terminal wire circuits, tightening all kind of nuta and bolts, screws atc, cleaning inside the chamber, enclosure etc, checking the connection of CT coil from panel to main incoming source and repairing in case of any fault in connections all as specified and as directed by Engineer-in-Charge. Note: Replacement of Spares shall be measured and paid separately.
Supply and replacement and testing at site of the following accessories of APFC panel:
(a) Cylidrical series capacitors, KVAr rating 2, 440V, 3Ph, heavy duty, make L&T, Cta part No LTCOH or equivalent
(b) Cylindrical series capacitors, KVAr rating 5, 440V, 3Ph, heavy duty, make L&T, Cta part No LTCOH or equivalent
(c) Cylidrical series capacitors, KVAr rating 10, 440V, 3Ph, heavy duty, make L&T, Cta part No LTCOH or equivalent
(e) VAF + PF meter accuracy class 1.0. 0.5, input voltage measurement range 50 - 520 VAC (P-P), Aux supply 80-300 VAC/DC, CT secondary side 1A/5A, Flush mounting 96x96, CT/PT programmable, Para meters VLL, VLN, A, F, PF, On Hrs, RPM, Apeak etc with RS485, Cl-1, Make L&T, Cat Part No WL4110110000
S & F in replacement of DI (Ductile Iron) flanged end on both sides of 150 mm dia , K-9 complete with rubber gasket nuts, bolts and washers (Make : Jindal/ Electrosteel/ Tata) complete all as specified and as directed.
S&F DI fittings such as tail piece, Socket and flange end, DI reducer socket 150 x 100 or any other size, Equal tee of any size and type, reducer Tee of any size and type etc all as specified and as directed by Engineer-in-Charge
M & L for painting applying spray painting of two coat synthetic enamel paint of approved colour on motor and pumpset centrifugal type 30HP,monoblock pumpset,mounting channels of pumpset of any size and painting of MS sheet cover fabricated on open well No 1, 2 and 3 at Gundrai after preparation, painting of sluice valve / NRV /Air Release valve and without disturbing anyother parts of the complete set complete all as specified and as directed by Engineer-in-Charge.
M&L for providing angle iron support under the NRV at Well No 2 including, cutting, bending, fabrication, welding, and one coat anti corrosive primer and one coat synthetic enamel paint all as specified and as directed by Engineer-in-Charge.
M&L for painting with two coat of anticorrosive paint over one coat of primer on GI/CI pipeline of any size at Kesarbagh sump house, pump house No 1, 2 and 3 at Gundrai, bore well pump house at India lake, delivery pipe of UG sump monoblock pumpsets located in 6 x hostels etc after preparation of surface with sand paper complete without damaging other parts all as specified and as directed by Engineer-in-Charge.
M&L for replacing gland packing by dismantling Gland plate and stud, cleaning inside the packing house etc for suitable size of 150mm sluice valve, leakage testing and obtaining OK result from Engineer-in-Charge all as specified and as directed.
M&L for greasing on motor and pumpset nipples , replacing burnt gland packing of any size and of centrifugal/monoblock pumspset of any size and capacity including leakage and damiging testing and obtaining OK result all as specified and as directed by Engineer-in-Charge.
M & L for Nuprine rubber / Leather gasket minimum thickness 8mm suitable for tightening the GI flange or any othe joints of 100mm dia with nuts and bolts complete all as specified and directed.
Demolition of old PCC foundation any type and size including removal of anchor bolt and removing debris from site at safe place as eco friendly manner all as specified and as directed by Engineer-in-Charge
M&L for PCC 1:3:6 type C-1 (using 20 mm graded stone aggergate) for pumpset platform and other misc pedestal supports, complete including form work etc all as specified and directed by Engineer in Charge
S&F in repair display board of Pumpsets, DG sets, Motors, Open well, Bore well, starter panels, monoblock pumpsets, chlorination plants etc of size 60cm x 30cm x 2 mm thick made of two laye acrylic sheet including relevent letter of size 7cm height and 1.5cm thick of white colour on blue layer sandwitched between two acrylic layers, including fixing, revetin or screwing on the wall all as specified and as directed by Engineer in Charge.
M & L for Calcium based high strength granular Chlorination chemical water disinfectant, a white free flowing granular material which is free of Foreign materials, concentration of Chlorine content should be between 60 to 70 percentage stability complete all as specified and directed.
Development of tube well with compressed air and after with 25% extra capacity pump by pumping muddy water with the help of suitable pneumatic boring compressor at Gundrai and Kesarbagh whereever complete all as specified and directed.
supply ,install and testing 5 HP submerssible motor at gundrai bore well as specified and complete set including taking down old u/s subersible motor make;-kirloshker/KSB/CG complete all as specified and directed.
M & L for dismantling existing broken valve pit complete with corroded MS sheet cover including removal of all material and construction of valve pit chamber, brick masonry all as specified in drg No TD/2004/26 sheet 1/3 to 3/3 for sluice valve including plastering, PCC in foundation excavation and earth work, MS sheet cover (3mm thick) with locking arrangement, painted with two coats of anticorrosive paint over one coat of primer of following sizes:-
(a) 1000mmx 950mm x 1000mm
(b) 1200 mmx 1200mmx 1000mm
Supplying, installation, testing and commissioning of submersible pump set of 5HP Capicity ,coupled with submersible motor with sutiable delivery , head more than 60mtr discharge 1000LPM including mounting accessories ,GI clamp , channels ,rubber gasket hanging rope made up of SWR or nylon water proof rope of sutiable dia etc and fabrication if any at gundrai bore well all as specified and directed by engineer-in-charge. Make- Kirloshkar/KSB/CG
M&L for cleaning of underground sump near academic block and sump is covered by MC chanel 74x40 mm for 1 mtr height 4 nos from base and embaded in PCC, top base made out of 65x65x6mm angle iron with flat wire mess of 20mm dia including necessary connection of pipe from main pipe line to sump and including all kind of fitting and top of the sump should be covered by fiber sheet from top and all 4 side of sutiable guage and including necessary repair of leakage of sump including lower/lifting arrangement of angle iron and pcc work to support angle iron and all plastering work of sump and foot path around 5x1 mtr as directed by engineer-in-charge
PD GUPTA AND COMPANY
Vijay Electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .