Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | FIRST₹40.6 LAccepted-AOC SITE NO 29 30 1ST CROSS NAGAPPA REDDY LAYOUT KAGGADASAPURA CV RAMAN NAGAR PO BANGALORE 560 093 | BANGALORE | BANGALORE | KARNATAKA | 560093 | FIRST | Accepted-AOC BEING LOWEST | |
| 2 | SECOND₹41.4 LRejected-Finance 14 3RD CROSS ASHWATHNAGAR RMV 2ND STAGE SANJAY NAGAR POST HEBBAL BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | SECOND | Rejected-Finance BEING NOT LOWEST | |
| 3 | THIRD₹43.9 LRejected-Finance NO 49 MSN NILAYAM 3RD CROSS HILL VIEW GARDEN TUNAHALLI SUBRAMANYAPURA POST BANGALORE 560061 | BANGALORE | BANGALORE | KARNATAKA | 560061 | THIRD | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
27 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) MARATHAHALLI
GE AF MARATHAHALLI WIND TUNNEL ROAD, KEMPAPURA, YEMALUR POST, BANGALORE. PIN- 560037
ADDITION ALTERATION TO SALVAGE YARD AT ASTE AND CERTAIN SANCTIONED WORKS AT ASTEUNDER GE AF MARATHAHALLI
2023_MES_583428_1
8608/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) MARATHAHALLI
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE (AF) MARATHAHALLI
₹84,000
Yes
6 May 2023
28 Feb 2023
1 Apr 2023
28 Feb 2023
27 Mar 2023
14 Mar 2023
Amount
Demolition of brickwork or stone/ boulder masonry, built in cement mortar , incl all quions, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and directed.
Excavating over areas in hard / dese soil, n exc 1.5 m deep and getting out, complete all as specified and as directed.
M&L for PCC 1:4:8, type D-2 using 40mm graded crushed stone aggregate as in pillars and post concrete, foundation and mass filling complete all as specified and directed.
M&L for RCC M-25 Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, complete all as specified and directed.
M&L for RCC M-25 Beams, cantilevers, lintels, columns pillars, piers, posts, struts,chullah hoods, stair case, arches, domes, vaults,shell roofs, arch ribs, folded plates, slabs,balconies, canopies, deck slabs etc. or in similararticles upto 5th floorlevel, complete all as specified and directed.
M&L for TMT Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for appropriate concrete epoxy bonding agent applied on old concrete surfaces after removing old plaster and cover concrete of extg structure, cleaned and applied as per manufactures instruction, complete all as specified and directed. Make : FOSROC/ Dr. Fixit .
Formwork to sides, on flat surfaces of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, complete all as specified and directed.
Formwork to flat surfaces of soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick, complete all as specified and directed.
Material and labour for Pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width 1:3:6 Type C-1 (20 mm graded crushed stone aggregate ) and setting in mortar CM 1:6, complete.
Rendering 10mm thick in cement mortar in 1:4 on fare faces of brick work or concrete surfaces even and smoothe without using extra cement.
M & L for rendering 5mm thick cement plaster in cement mortar 1:3 on ceiling including finished even and smooth without using extra cement
M&L for preparation of new surface/undecorated surfaces surface of ceiling and applying three coats of white washing.
M&L for preparation of new surface/undecorated surfaces of walls and applying two coats of Oil bound distemper over a coat of priming on plastered and other surfaces with alkali resistant priming paint including one coat of Birla white putty etc. complete all as specified.
S&F powder coated anodised alluminium frame for sliding doors, window, ventilators, partitions with one or more rebates including joining cleat etc. (minimum thickness of powder coating 50 micron) and fixing/finished with metal paste on gaps of the surface in contact with stone masonry walls / brick walls complete all as specified and as directed by Engr-in-Charge.
S & Fix 5.5mm thick Sheet glass of ordinary quality and glazing with oil putty in square exc 0.5 sqm in each pane fixed to alluminium frame works with necessary rubber beadings etc. Complete all as specified and as directed
Rendering 15mm thick in cement mortar in 1:6 with WPC on fare face of brick work or concrete surfaces even and smoothe without using extra cement. (Note: Integral Water proofing compound will be measured and paid for separately).
M&L for preparation of new surface/undecorated surfaces of walls and applying two coats of Cement Base Paint of approved tint over and including a coat of priming on plastered and other surfaces with alkali resistant priming paint complete all as specified
Material and Labour for PCC (1:2:4) type B-0 using 12.5 mm graded crushed stone aggregate as in roof slab, etc. including necessary form work complete as directed.
Material and labour for Rendering 5 mm thick on fair concrete surfaces in CM (1:3) finished even and smooth without using extra cement mixed with 2% Integeral Water proofing compound by weight of cement complete all as specified and as directed by Engr-in-charge. (Note: Integral Water proofing compound will be measured and paid for separately).
Supply only integral water proofing compound.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises.
M & L for screed bed for bedding layer of mortar 15 mm thick for laying floor finishes in cement mortar 1:6 complete all as specified and directed. .
M&L of Non-skid Ceramic joint free tiles coloured shade size 600 x 600mm, 7 to 8 mm thick in (Squre / Rectangular) polished, area of each tiles not exceeding 0.18 sqm but not exceeding 0.38 sqm in floors etc. set and jointed in neat cement slurry of 3kg/sqm and pointed in white or coloured cement match complete all as specified and directed.
Material and labour for 40mm thick PCC 1:2:4 Type B-1, using 20 mm graded crushed stone aggregate as in sub floor complete all as specified and directed. .
Demolition of Cement Concrete (unreinforced) of any description and in any position not otherwise specifically provided for, complete all as specified and directed.
M&L for Granite (of any type) slabs/tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing over and including 20mm thick Screed bed or bedding layer for laying floor finishes in cement mortar 1:6 complete all as specified and directed.
M&L for 20mm thick Granite (of any type) tiles machine cut, in skirting/ dado laid over cement screed and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing over and including 10mm thick rendering on fair faces of brick work or concrete surfaces in cement mortar 1:3 complete all as specified and directed.
M&L 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including 20mm thick Screed bed or bedding layer for laying floor finishes in cement mortar1:6 including roughening of surface wherever required etc complete all as specified and directed.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations
S&F stainless steel staircase railing & balusters of 16 gauge(1.65 mm thick) of Grade 304 mirror finish including cutting holes into Granite, fixing, fabrication, polishing and making good the suraface all as per specifications given below and directed by EIC. Top Railing : 50 mm S/S tubes on railing. Blusters 40mm x 40mm hollow square @ 0.90 mtr height above GL and 0.75 mtr(75CM) spacing . 30mm x 50mm D Brackets on bottom of Balusters 3 Nos of support railing on balusters of 32 mm dia SS tube. S/S Doom of suitable size on first baluster or as required in any locations all as specified by the Engr-in-charge.
S&F stainless steel sheet moulding/bending as required of Grade 304 mirror finish including cutting holes into RCC/Granite, fixing, with steel dash fastners of required and approved size to take sufficient load of sheet etc. including fabrication, polishing and making good the surface complete all as per specified and as directed by Engr-in-Charge.
Dismantiling wrought iron or mild steel work of any description not otherwise provided for etc comoplete all as specified.
Material and Labour for PCC (1:2:4) type B0 using 12.5 mm graded stone aggregate as in coping, mud stops, benching, water tank platform etc.on roof, chajja weathering, slightly rounded or chamfered angles and throating etc. including necessary form work complete as directed.
Rendering 15mm thick in cement mortar in 1:4 on fare face of brick work or concrete surfaces even and smoothe without using extra cement.
Removing building materials etc. to a distance of 5 Km out side MoD/Unit land including loading, unloading and stacking at the destination etc. complete all as direction of Engineer-in-charge,
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, in soft/loose soil complete all as specified and directed.
M&L Cement concrete 1:3:6 Type C-2 (40 mm graded crushed stone aggregate) in foundation / wall or retaining walls, and thickness, size or shape including pilasters, buttresses columns pillars, boundary pillars complete all as specified and directed.
S&F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St-240 complete all as specified and directed.
M&L for Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Complete all as specified and directed.
S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specifed and directed by Engineer-in-charge.
M&L for painting steel & iron two coats of synthetic enamel paint over and including a priming coat of red oxide including preparation of surface all as specified and directed.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in hard/dence soil complete all as specified and directed.
Demolition of PCC in ground floors & paving exc 15cm thickness (below or above GL), complete all as specified and directed.
M & L for broken stone or boulders hard core of gauge n exc 63mm deposited spread and leveled in layers n.exc 15 cm thick each watered and rammed to true surface complete all as specified and directed.
M&L for 75 mm thick PCC 1:4:8 (40 mm graded crushed stone aggregate) type D2 as in sub- base of floor complete all as specified and directed.
M & L for 100mm thick PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in floors and pavings etc, finishing with spike rolling to surfaces or making impressions of expanded metal, whilst the concrete is green, complete all as directed by Engr-in-charge.
Forming 12 mm thick expansion joints in 100mm thick concrete filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound Grade ‘B’, complete all as specified and directed.
M&L 50 mm thick sand filling under floor or in foundation including watering & consolidation complete all as specified and directed.
M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and no pigment complete all as specified and directed.
M&L for 20 mm thick screed bed CM (1:4) or bedding layer of mortar for laying floor finishes all as specified and directed.
M&L Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, With grey cement with no pigment jointed and pointed in neat cement slurry in floors all as specified and directed.
Material and labour for precast cement concrete block masonry with solid blocks in PCC 1:3:6, type C1 using 20mm graded aggregate exceeding 10cm width and setting in CM 1:4, complete.
Rendering 15mm thick cement mortar in 1:4 on stone masonry surfaces or surface other than fair face of brick-work or on one side of lathing without using extra cement.
Providing, cement concrete 1:2:4 Type B-0 (12.5mm graded crushed stone aggregate) in roof kerbs or mud stops, rounded chamfered on edges including necessary form work complete all as specified and directed.
M&L for Walling of random rubble, uncoursed, well bonded, laid dry in retaining walls, abutments and similar work complete all as specified and directed.
Demolation and dismantling of reinforce cement concrete ( reinforcement cut as required to facilitate demolition) complete all as specified and directed.
Providing, precast cement concrete 1:2:4 Type B-1 (20 mm graged crushed stone aggregate) as in manholes cover slab, etc.(of any section indicated), with plain fair faces, including chamfers weatherings, throating etc. and setting in cement mortar 1:4 complete with joints to match complete all as specified
Removing excavated material to a distance exc. 1.50 km but n exc. 5 km and depositing where directed complete all as specified and directed.
Removing building materials etc.to a distance 5 km or under, beyond the lead included in the rates, including loading, unloading and stacking at the destination complete all as specified
Rendering 15mm thick cement mortar 1:6 on other than fare face of brick work or concrete surfaces and finishing the surface even & smooth without using extra cement
Taking down chowkhats or frame exc 1.5 Sqm but n.exc 4 Sqm each with shutters (W/out taking off shutters from the frames), door and window frames with shutters and refixing the same in other opening without damaging the door/windows etc complete all as specified and directed by Engineer-in-Charge. If there is any damage to the asset by the contractor, the same will be repaired and remake the same without any extra payment.
Supply and Fixing 10mm thick Toughened glass door, superior quality exc 1.5 sqm in each pane including, necessary fittings and fixures, mortice lock, beading screws, bearings, 600mm long and 25mm dia stainless steel handles - 2 Nos in each door etc including Air force embalams/writing work as per design given by Engr-in-charge and as required eitching, cutting for counter etc. Fitting and fixtures as required including fixing details shall be as per manufactures instructions complete all as specified and as directed by Engr-in-charge.
M&L for Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover,governing pivot made of brass, other parts made of mild steel heavy duty and fixed including takingdown existing one etc complete.
S&F of 12mm thick toughened glass exc 0.5 sqm of each pane of superior quality fixed to alluminium frame works with rubber beadings etc. Complete all as specified and as directed by Engr-in-Charge.
S&F Powder coated (minimum 50 micron) Anodised aluminium frame for doors,windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified
S & F Powder coated anodised alluminium window and ventilator shutters sliding type without sash bar, aluminium sections weighing 0.55 Kg/m including joining cleats glazing clips, rubber packing , anodised aluminium snap beading, screws etc. complete all as specified and as directed by Engr-in-Charge.
Provision of 5.5 mm thick tinted glass exc 0.5 sqm of each pane of superior quality fixed to alluminium frame works with rubber beadings etc. Complete all as specified and as directed by Engr-in-Charge.
M&L for Coloured Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, on vertical surfaces such as skirtings, dados and risers to steps etc.. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:4 etc complete
Providing, precast cement concrete 1:2:4 Type B-1(20 mm graged crushed stone aggregate) as in manholes cover slab, shelves, etc.(of any section indicated), with plain fair faces, including chamfers weatherings, throating etc. and setting in cement mortar 1:4 complete with joints to match complete all as specified
M&L Anodised aluminium snap grid frame work for false ceiling , including Hangers of 6mm dia G.I ( upto 1200mm length adjusting level fixed to roof slab by means of ceiling cleats made out of G.I flat 40x3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long complete all as specified .
M&L 12mm thick perforated particle board/tiles for insulation and accoustic purpose, 60x60 cm in size,fixed with screws to aluminium frame work or with staples on snap grid, complete all as specified.
Taking down carefully copper/aluminium point wiring of any type of batten or conduit (Light, Fan, Socket or power) complete removing material from site and making good the disturbed surfaces of walls, roofs etc including two coats of white/colour washing/distempering etc to match the existing complete all as directed by EIC.
Taking down fan, sealing cable end,dismantling blades and removing fan and blades to store and after false ceiling work hanging only ceiling fan (M.D supply) with extension rod as per site required and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and directed.
Taking down carefully unserviceable sub main wiring of any size and type including making good the disturbed surfaces of walls, ceilings etc including two coats of white /colour washing/ distempering etc to match the existing complete all as directed by EIC.
Taking down carefully unserviceable distribution boards/metal enclosures of any type and capacity including wooden board and making good the disturbed surfaces of walls, ceilings etc including two coats of white/colour washing/ distempering etc to match the existing complete all as directed by EIC.
M & L point wiring with 1.5 sqmm nominal cross sectional area, single core, 1100 Volts FRLS grade, stranded, PVC insulated, unsheathed copper conductor cable drawn through PVC concealed conduit of suitable size, complete with all PVC conduit accessories/ fittings, brass screws, washers etc, including metal flux boxes of suitable size and modular white plate with frame for mounting modular switches, sockets and regulators etc, including all cutting/chases etc in walls and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated copper conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed for the following:- (a) One light point /Fan point controlled by one switch.
Description all as per item No 77 above but One 5 Amps socket point on same board with other switches
Description all as per item No 77 One 5 Amps socket point on independent board.
Description all as per item No 77 but wiring complete with 2.5 Sqmm for 3 pin 15A socket multipurpose on independent board .
Description all as per item No 77 but wiring complete with 4 Sqmm for AC point
Material and Labour for ceiling rose 3 terminals complete all as specified & directed.
Supply & fixing modular switch 06 Amps 1 module complete all as specified & directed
S & F modular socket 06 Amps 2/3 pin combined 2 module complete all as specified & directed.
Supply & fixing modular switch 16 Amps 1 module complete all as specified & directed
S & F modular socket 15/16 Amps 2/3 pin combined 2 module complete all as specified & directed.
S & F in repair electronic fan regulator modular type, 2 module, 120W including complete all as specified and directed.
Supply and fixing 36W LED Fitting, 2 x 2 recess / Surface LED flat panel with high brightness LED for glare free homogenous illumination including LED driver complete all as specified.
Supply and fixing Decorative, surface mounting, dome shaped pendant in green & black finishes Upto 7.5 W A60 LED Filament Lamp Black complete all as specified and directed.
S&F in replacement single pole and neutral enclosure with two pin and earth plug and socket including 1Nos MCB 20Amps capacity complete all as specified and directed by Engr-in-charge.
S & F MCB SPN 32 Amps, 'C' series, 240 V complete incl making conections all as specified and directed.
S & F MCB SP 6-32 Amps, 'C' series, 240 V complete incl making conections all as specified and directed.
S & F MCB DB SPN 8 Way with 200 Amps rated busbar, Double door, 240 volts flush to wall including all cutting etc on wall and making good the disturbed surfaces to match the existing complete all as specified and directed.
M & L for sub main wiring complete with two runs of 4 Sqmm single core FRLS grade PVC insulated unsheathed cable 1100Volt grade multistranded copper conductor drawn through and including PVC conduit/ casing caping of suitable size and accessories in concealed/surface of wall, roofs etc with one run of PVC insulated copper conductor 4 Sqmm single core as earth continuity conductor connected with earth dolly and mains complete all as specified and directed.
Supply and fixing in repair of Earthing to panel with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to galvanised earth lead wire 4.0mm dia by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.3 of MES Schedule pt-I 2009, GI earth lead strip protected by GI pipe 40 mm dia light grade and connected to earth test point including excavation in any type of soil,returning filling, disposal of soil, providing charcoal dust and common salt upto top edge of earth plate, construction of PCC pit with RCC cover, funnel, watering pipe of 20mm dia GI light grade and provision of earth test point including testing on completion complete all as specified and directed.
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser for better indoor air quality with minimum 5 star rating EER 3.2 of capacity 1.5 TR including with stand and all accessories and necessary connection complete all as specified and directed by Engr-in-Charge. (Note :- The extra length of suitable size of AC gas copper pipe / cable for installation of AC as per site requirement is deemed in the quoted rate.)
Supply and installation of Voltage stablizer for automatic operation, single phase naturally air cooled indoor type wall mounted copper wound and dsigned for input variation between 170 Volts to 250 Volts with output Voltage Stablizer at 230 with of +- 2.5% and capacity of 5.0 KVA with digital voltmeter and suitable capacity plug top complete all as specified and as directed. Make: V-Gaurd /Volina/ AE.
M&L for mild steel stand duly painted suitable for fixing 3/2/1.5 TR ,AC out door unit fixing in wall / floor, including making bore required size for copper pipe & copper cable with sweating pipe required size and length upto ground level complete all as spcecified and directed.
Taking down Split AC 1.5/2 Ton capacity ( Indoor and Out door Unit) with stabilizer by removing all electrical connections and indoor to out door unit gas pipes ,nut bolts from roof top of P-34 bldg before starting False ceiling work and shifting to store for safecustody. After completion of False ceiling work, Refixing /installing Split AC 1.5/2 Ton with voltage stabilizer at the suitable place by connecting all electrical connections and copper piping with insulation (5/8th x 1/4th) with nut bolts as per site requirement, testing and commissioning , if any extra cable , gas pipes , gas filling require at the time of installation the quoted rate is deemed to be included , No nextra cost will be paid to contractor complete all as specified and directed By Engr- In - Charge.
S&F in repairs modular White cover plate with frame 3 module complete all as specified & directed
S&F in repairs modular metal flush box 3 module complete all as specified and directed.
S&F in repairs modular White cover plate with frame 6 module complete all as specified & directed
S&F in repairs modular metal flush box 6 module complete all as specified and directed.
Supply and fixing wall fan of single phase 230/240V of size 400 mm sweep and grouting with nut , bolts & Fastenar on the wall and make good the disturbed surface and electric connection with 1.5 Sqmm three core PVC insulated round flexible copper conductor and sheathed cable complete all as specified and directed .
M & L for sub main wiring complete with two runs of 2x2.5 sqmm FRLS grade PVC insulated unsheathed cable 1100Volt grade multistranded copper conductor drawn through and including PVC conduit and accessories in recessed / surface of wall, roofs etc with one run of PVC insulated copper conductor 1x2.5 Sqmm single core as earth continuity conductor connected with earth dolly and mains complete all as specified and directed.
Taking down cement plaster including raking out joints hacking for key scrubbing down with water etc including removal of debries outside MOD Land complete all as specified and directed.
M/s SL CONSTRUCTION
PRAGATHI BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .