12 conditions · 4 needing a document upload
The following documents should be attached with the tender ( Annexure-V (A) certificate is to be given by attorney/authorized signatory/each member of Partnership firm/Joint Venture (JV) / Hindu Undivided Family (HUF) / Limited Liability Partnership (LLP) etc. & Scanned copy POA/Partnership deed is to be uploaded Duly filled up by the bidder
Scanned copy of valid GST (Goods & Service Tax)Registration Certificate.
Partnership deeds, power of Attorney etc. (if any) : The tender shall clearly specify whether the tender is submitted on his own or on behalf of a partnership concern. If the tender is submitted on behalf of partnership concern he should submit the certified copy of the partnership deed along with the tender authorisation to sign the documents on behalf of the partnership firm. If these documents are not enclosed along with the tender document, the tender will be treated as hearing lease submitted by the individual signing the tender documents. The Railway will not consider any power of Attorney granted by the tender or any changes in the composition of the firm made subsequent to the execution of the contract. It may however recognize such power of Attorney and change after obtaining proper legal advice, the cost of which will be chargeable to the contract.(Scanned copy POA/Partnership deed is to be uploaded Duly filled up by the bidder. As per clause no. 14(e) of GCC'22, the following documents to be uploaded in terms of Company registered under Companies Act2013: (i) The copies of MOA (Memorandum of Association) / AOA (Articles of Association) of the company (ii) A copy of Certificate of Incorporation (iii) A copy of Authorization/Power of Attorney issued by the Company (backed by the resolution of Board of Directors) in favour of the individual to sign the tender on behalf of the company and create liability against the company. (iv) All other documents in terms Para 10 of the Tender Form (Second Sheet) above.
Scanned copy of valid Trade license or Propitorship Certificate.
List of the Works completed in the last three financial years giving description of work. Organization for whom executed, approximate value of contract at the time of award, date of award and date of scheduled completion of work. Date of actual start, actual completion and date of payment and final value of contract should also be given. (Supportive documents/ certificates from the organization with whom worked/are working should be enclosed) (Please attach scanned copy of Annexure-I duly filled up).
List of works in hand indicating Supportive documents/certificates from the organization with whom worked/are working should be enclosed) description of work, contract value, approximate value of balance work yet to be done and date of award. (Supportive documents/certificates form the organization with whom worked/are working should be enclosed).(Please attach scanned copy of Annexure-IV duly filled up)
Railway Officers Associated with tenderer:RAILWAY OFFICERS ASSOCIATED WITH TENDERER 1. ExRailway Officer as tenderer: Should tenderer be a retired Gazetted Officer working before his retirement on any of the Railways owned and administered by the President of India, or should the tenderer being partnership firm have as one of its partners a retired Gazetted Officer as aforesaid, or should the tenderer being an incorporated company have any such retired Officer as one of its Directors, or should the tenderer have in his employment any retired Gazetted Officer as aforesaid, full information of such person shall be submitted along with his tender in the format given in annexure-VI to this chapter of this tender document. (Authority: ACS No.3 to GCC July,2014vide Boards letter No.2014/CEI/CT/O/9/RET dt.22.01.2015)(please attach scanned copy of Annexure-VI duly filled up by the firm).
Option for receiving payment through Letter of Credit . (Please attach scannedcopy of ANNEXURE 1 LC & ANNEXURE 2 LC duly filled up by the firm if optedfor)
The following documents should be attached with the tender: (i)Scanned copy of Pan Card. (ii)Scanned Copy of EFTMANDATE FORM Duly filled up by the bidder(iii)Tender Document (duly digitally signed by the bidder)
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
The Contractor/(firm) must go through the entire tender document along with all attachment for any kind of guidance regarding execution of the job & payment there after. In case any thing is left out or not clear then they should consult the General Condition of Contract & standard Specification as attached (uploaded ).The bidders are also advised to preserve a copy of entire tender document/ (Set) for their convenience.
Electrical (General) work in connection with "Provision of Yard & Pit Line Illumination at Azimganj Yard".
EL-HWH-25-21-3648
EL-HWH-25-21-3648
Open
Works - General
180 Days
Howrah, West Bengal
₹0
₹91,900
22 Jul 2026
29 Jun 2026
8 Jul 2026
71 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 45,93,714 | ||
| — | — | — | Above/ 683340.00 Below/P | ||
| Supply of High Mast Tower of 20 Mtr. height in two sections suitable for a wind speed of 180 km/Hr. ( 50 m/s ) made from Steel Plates and continuously tapered of polygonal cross section with minimum bottom diameter 450 mm or higher. The entire mast should be hot dipped galvanised after fabrication internally and externally in accordance with BS 729. All steel used in the construction of mast complies with BS EN 10 025 of appropriate grade and welding is in accordance with BS 5135 and comprising with lighting finial & earthing terminal, Top pulley assembly, double drum winch, Head frame & lantern carriage, stainless steel wire rope having 7/19 construction ( The central core is also SS ) with a grade of AISI 316 of breaking strength 2350 kgs, winch driving power tools (motor), multi core flexible round and sheathed copper power trailing cable (2 nos.) with cable junction box (2 nos.) including aviation obstruction warning light, timer for automatic switching operation of luminaires and all other accessories. ( Make - Utkarsh / B.P. Projects / Crompton / Bajaj / Surya ) | — | 4.00 | — | — | |
| — | — | — | Above/ 50836.00 Below/P | ||
| Design and construction of RCC foundation depending upon the height, wind speed and terrains including erection, testing and commissioning of above High Mast Tower including foundation accessories alongwith Earthing with 2 nos. of 50mm dia, 3 Mtrs. long heavy gauge GI pipe ( Make - TATA / Jindal / Bansal ) with construction of earth pit and necessary earth connection from pit to tower by two separate 40mm x 6mm GI flat with GI nuts & bolts. ( For details not covered in this specifications, Indian Standard Code of Practice for earthing IS : 3043 - 1987, Reaffirmed - 1996 should be followed ) | — | 4.00 | — | — | |
| — | — | — | Above/ 67360.00 Below/P | ||
| Supply of Outdoor pillar box type control panel board made of 14 SWG ( 2mm ) MS sheet duly powder coated comprising with the following : a) MCCB with Thermal - Magnetic Release of breaking capacity 36 kA at 415V AC, 50Hz ( Ics = 100% Icu ) suitable for release range 25-32A, 4 Pole - 1 no. b) Astronomical Timer Switch - 2 nos. c) Power Contactor, 3 Pole, 18A, 415V, 50 Hz - 2 nos. d) LED indication lamp for 3-Phases for incoming feeders and "ON, OFF, TRIP " indication for all incoming and outgoing feeders - 10 nos. complete with fabrication, internal wiring by single core copper conductor cable and all other accessories for above panel ( Make - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider / C&S ) | — | 4.00 | — | — | |
| — | — | — | Above/ 3356.00 Below/P | ||
| Fixing, connection, testing and commissioning of above panel including all incoming and outgoing cables glanding, cable socketing and connection and construction of concrete foundation or suitable wall hanging arrangement as per site condition with all associated accessories | — | 4.00 | — | — | |
| — | — | — | Above/ 106600.00 Below/P | ||
| Supply of GI ( minimum coating thickness 65 microns ) conical / octagonal ( minimum sheet thickness - 3mm ) Pole of overall length 3 M with single / double arm bracket, top cover, base plate including hinged door-inbuilt Junction box complete with copper bar, insulator, Hylam sheet for cable termination and fuse kit-kat / MCB ( Make - Utkarsh / B.P. Projects / Crompton / Bajaj / Surya ) | — | 20.00 | — | — | |
| — | — | — | Above/ 62320.00 Below/P | ||
| RCC foundation, erection and commissioning of above GI pole with construction of cement concrete muffing ( Cement : Stone : Sand = 1 : 2 : 4 ) with foundation accessories including earthing of pole with 1 no. of 50 mm dia, 3 M long GI pipe ( Make - TATA / Jindal / Bansal ) with necessary earth connection from pipe to pole by GI Strip / GI wire | — | 20.00 | — | — | |
| — | — | — | Above/ 13246.00 Below/P | ||
| Wiring of light point by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for phase and neutral through pole from inbuilt pole Junction Box's porcelain fuse kit-kat / MCB to light fitting along with 1 no. single core HRFR / FRLS grade, PVC insulated copper conductor cable of size 1.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ). ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 74.00 | — | — | |
| — | — | — | Above/ 81400.00 Below/P | ||
| Designing of mounting layout, supply, installation, connection and commissioning of Street light 90 Watt LED (Type of LED - Surface Mounting Device ) luminaire, pressure die cast housing with Ingress Protection - IP66 or higher ( LED chip make - Nichia, Osram, Seoul, Philips, Lumileds, Everlight, Avago, Cree, Lednium, APT Electronics & BridgeLux ), complete with all accessories, LED luminaire system Efficacy minimum - 130 Lumens per Watt @ 350mA drive current, Impact resistance IK-05 or higher, Colour Temperature - 5700K, Driver Surge Protection minimum 4KV, Life span of LED chip Greater than 50000 burning hours, The Luminaire & Driver both should be of same make / brand and individually BIS approved with 60 months warranty including fixing, connection and commissioning of outdoor Flood light / Street light fitting on High Mast Tower / Pole / Structure with suitable arrangement. ( Make : Philips (Signify) / Havells / Bajaj / Panasonic / Crompton / Jaquar / Lighting Technologies / Halonix ) | — | 74.00 | — | — | |
| — | — | — | Above/ 183616.00 Below/P | ||
| Designing of mounting layout, supply, installation, connection and commissioning of Flood light 300 Watt LED (Type of LED - Surface Mounting Device ) luminaire, pressure die cast aluminium housing with Ingress Protection - IP66 or higher ( LED chip make - Nichia, Osram, Seoul, Philips, Lumileds, Everlight, Avago, Cree, Lednium, APT Electronics & BridgeLux ), complete with all accessories, LED luminaire system Efficacy minimum - 130 Lumens per Watt @ 350mA drive current, Impact resistance IK-05 or higher, Colour Temperature - 5700K, Driver Surge Protection minimum 4KV, Life span of LED chip Greater than 50000 burning hours, The Luminaire & Driver both should be of same make / brand and individually BIS approved with 60 months warranty including fixing of outdoor LED Flood light / Street Light fitting on High Mast Tower/Pole/Structure with suitable arrangement. ( Make : Philips (Signify) / Havells / Bajaj / Panasonic / Crompton / Jaquar / Lighting Technologies / Halonix ) | — | 64.00 | — | — | |
| — | — | — | Above/ 406509.00 Below/P | ||
| Supply of corrosion resistant, surface mounting, Industrial 20W-40W LED luminaire with PC housing and cover suitable for wet location with Ingress Protection - IP65 or higher complete with 20-40 Watt LED ( Type of LED - Surface Mounting Device ) with industrial grade constant current Driver ( Efficiency - Greater than 85% ) with short circuit protection, ( Make / brand of LED chip - NICHIA, OSRAM, SEOUL, PHILIPS, LUMILEDS, AVAGO, CREE - as per RDSO's functional requirement specification ), LED luminaire Efficacy - greater than 100 Lumens per Watt @ 350mA drive current, Life span of LED chip - Greater than 50000 burning hours including all other accessories. ( Make : Philips (Signify) / Havells / Bajaj / Panasonic / Crompton / Jaquar / Lighting Technologies / Halonix ) | — | 179.00 | — | — | |
| — | — | — | Above/ 13246.00 Below/P | ||
| Fixing, connection and commissioning of LED luminaire fittings with suitable arrangement. | — | 179.00 | — | — | |
| — | — | — | Above/ 348500.00 Below/P | ||
| Supply of Pit Light luminaire of 18-22 Watt LED ( Type of LED - Surface Mounting Device ), pressure die cast housing with Ingress Protection - IP67 or higher ( LED make-Nichia, Osram, Seoul, Philips, Lumileds, Avago, Cree ) complete with all accessories. LED luminaire Efficacy - Minimum 130 Lumens per Watt, Impact Resistance : IK-10 or higher, Color temperature : 5700K, Driver Surge Protection minimum 4KV, Life span of LED chip - Greater than 50000 burnings hours with 60 months warranty suitable for operation on 1Ph, 48V AC, 50 Hz supply system as per site condition. ( Make : Philips (Signify) / Havells / Bajaj / Halonix / Panasonic / Lighting Technologies / Magik / Jaquar / Crompton ) | — | 82.00 | — | — | |
| — | — | — | Above/ 16400.00 Below/P | ||
| Fixing, connection, testing and commissioning of above Pit Light luminaire along with 2 nos. Fastner FRP Board and connection with water proof (IP 67 or higher) cable gland, termination and necessary copper cable etc. | — | 82.00 | — | — | |
| — | — | — | Above/ 400000.00 Below/P | ||
| Wiring of Light point by 4 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 4.0 sq.mm, 1100V grade for three phases and one neutral in GI conduit of 25mm dia along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 2.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ). ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 800.00 | — | — | |
| — | — | — | Above/ 94400.00 Below/P | ||
| Conceal wiring on concrete pit wall through PVC pipe of suitable diameter for submain by two nos single core, HRFR/FRLS grade, PVC insulated, copper conductor cable of size 4.0 sq.mm., 1100V grade for phase and neutral along with one single core, HRFR/FRLS grade, PVC insulated, copper conductor cable size 2.5 sq.mm., 1100V grade for Earth Continuty conductor including supply of cable, GI concelled box with modular cover plate, PVC pipe and all other associated work alongwith make good of wall surface as its original condition. ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 400.00 | — | — | |
| — | — | — | Above/ 99200.00 Below/P | ||
| Wiring of Light / Fan / Call Bell / Glow Sign point by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for phase and neutral in GI conduit of suitable dia along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ). ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 800.00 | — | — | |
| — | — | — | Above/ 232000.00 Below/P | ||
| Wiring of Light / Fan / Call Bell / Glow Sign point by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 2.5 sq.mm, 1100V grade for phase and neutral in GI conduit of suitable dia along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ). ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 1600.00 | — | — | |
| — | — | — | Above/ 56000.00 Below/P | ||
| Drawing of cable on wall / structure with suitable size and shape GI clamps including supply of suitable size GI Clamp and GI nut- bolts and commissioning of cable ( Cable will be supplied by Railway ) | — | 1400.00 | — | — | |
| — | — | — | Above/ 105300.00 Below/P | ||
| Trenching and laying of cable underground by pucca floor / concrete cutting with covering of cable through suitabe dia HDPE pipe including supply of HDPE pipe (PE-100 grade, PN-10 or higher) along with refilling the trench and make good of surface as its original condition ( Cable will be supplied by Railway ) | — | 450.00 | — | — | |
| — | — | — | Above/ 152000.00 Below/P | ||
| Trenching and laying of cable under ground by soil cutting through suitable dia HDPE pipe including supply of HDPE pipe (PE-100 grade, PN-10 or higher) alongwith refiling of trench by excavated soil and make good of surface as its original condition. ( Cable will be supplied by Railway ) | — | 1000.00 | — | — | |
| — | — | — | Above/ 13600.00 Below/P | ||
| Trenching and laying of cable underground by pucca floor / concrete cutting and commissioning of cable alongwith make good of floor surface as its original condition after laying of cable ( Cable will be supplied by Railway ) | — | 160.00 | — | — | |
| — | — | — | Above/ 56240.00 Below/P | ||
| Trenching and laying of cable underground by pucca floor / concrete cutting and commissioning of cable through 80mm dia GI pipe including supply of GI pipe alongwith make good of floor surface as its original condition after laying of cable ( Cable will be supplied by Railway ) | — | 80.00 | — | — | |
| — | — | — | Above/ 16480.00 Below/P | ||
| Trenching, laying under road / track through 50 mm dia GI pipe ( medium gauge ) including supply of GI pipe and commi- ssioning of cable including back filling of trench with excavated soil after laying of cable ( Cable will be supplied by Railway ) | — | 80.00 | — | — | |
| — | — | — | Above/ 8650.00 Below/P | ||
| Drawing of cable through one no. 2" dia, 3.0 Mtrs. long GI pipe ( Make - Tata / Jindal / Bansal ) for protection of cable on pole with proper GI clamps and GI nuts & bolts including supply of GI pipe ( Cable will be supplied by Railway ) | — | 10.00 | — | — | |
| — | — | — | Above/ 110240.00 Below/P | ||
| Supply of Thermoplastic Polycarbonate Busbar Chamber of dimen- sion 450mm x 300mm x 210mm consisting with 4 nos. tinned copper busbar of each bar of capacity 100 Amp, 4 way, suitable for 415V, 50Hz supply system and 4 nos. Cable glands with Ingress protection : IP65 or higher as per IEC-60529 ( weather proof), rust, dust, moisture and shock proof, anti corrosive, halogen free acid resistant, light weight, impact resistant IK 08/09 as per IEC- 60068-2-72, fire returdant, insulated, UV stabilised as per EN ISO 4892, should withstand glow wire test at 960 degree C as per IS 11000-2-1,IEC-60695-2-10 and fire rated UL94V-0 complete with hinged door with locking arrangement including fixing, connection and commissioning of above Junction Box on pole/structure with mounting clamp. ( Make : Hensel / Sintex / OBO Bettermann / RMC / Grasp / ABB / Legrand / Spelsberg / EPP Composites ) | — | 8.00 | — | — | |
| — | — | — | Above/ 127184.00 Below/P | ||
| Supply of TPN MCB DB ( Heavy duty, Outdoor type, UV ray protected, self fire- extinguishing and resistant to abnormal heat and fire up to 650 degree C GWT, shock resistance IK08 or above and IP65 degree of protection grade transparent DB box, similar to ABB Mistral65 - 20 Modules or equivalent ), 3Ph, 50Hz, 415V, 4 way per phase, 415V, 50Hz, complete with total 12 nos. SP MCB of current rating from 6A to 32A, 10 kA, 240 Volt, 50Hz per phase as per requirement of load and one no. FP RCBO 63A, 300mA, 10 kA, 415V, 50Hz, Suitable for AC + Pulsating DC (Type A) + Harmonics ( Make of MCB & RCBO - LK (L&T) / Siemens / ABB / Hager Legrand / Schneider ) ( Make of TPN DB - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider / Spelsberg / Hensel / Eaton ) | — | 8.00 | — | — | |
| — | — | — | Above/ 1096.00 Below/P | ||
| Fixing, connection, testing and commissioning of above TPN MCB DB including all incoming and outgoing cables glanding, cable connection with cable termination and suitable wall hanging arrangement as per site condition with all associated accessories. | — | 8.00 | — | — | |
| — | — | — | Above/ 26300.00 Below/P | ||
| Supply of MCB DP, 40A, 1Ph, 240V, 50 Hz, 10kA with polycar- bonate distribution box enclosure (IP-65) with polycarbonate trans- parent openable window including fixing, connection, testing and commissioning. ( Make of MCB - L&T / Siemens / ABB / Hager / Legrand / Schneider and Enclosure Board - Grasp / OBO Bettermann / ABB / Schneider ) | — | 20.00 | — | — | |
| — | — | — | Above/ 67024.00 Below/P | ||
| Supply of Indoor type 5 KVA, AN-dry type, resin casted, copper wound distribution transformer with primary voltage 415V AC, 3 phase, 50 Hz, secondary voltage 84V AC [P-P], 48V AC[P-N] 3-phase 50Hz, connection vector group Dyn-11 equipped with incoming MCBs, indication lamp, voltmeter, ammeter alongwith all other accessories with metal enclosure made of 14 SWG (2mm) powder coated MS sheet with minimum length of each leg will be 600 mm or above from ground level and as per IS:1180 copper wound with proper cable end copper lugs connection as per CEE' latest specification as per site condition. | — | 4.00 | — | — | |
| — | — | — | Above/ 6876.00 Below/P | ||
| Installation, commissioning, testing and connection of 5 KVA indoor type distribution transformer including concrete foundation. | — | 4.00 | — | — | |
| — | — | — | Above/ 139574.00 Below/P | ||
| Supply of LT cubicle type outdoor wall / floor mounted Distribution Panel Board made of 14 SWG ( 2mm ) MS sheet duly powder coated comprising with the following : a) MCCB with Microprocessor Release of breaking capacity 36kA at 415V, AC 50Hz ( Ics = 100% Icu ) with following features :- 1) Adjustable Over Load, 2) Adjustable Short Circuit, 3) Inbuilt ground fault protection, 4) Inbuilt Instantaneous protection, 5) Adjustable neutral overload protection, 6) Provision of Thermal Memory, 7) Microprocessor protection-based MCCB must have facility of individual 'LSIG' fault indication suitable for Release Range ( 63-160 ) Amp, 4 Pole - 1 no. b) Power Contactor, 4 Pole, 100A, 415V, 50Hz - 2 nos. c) Astronomical Timer Switch, 2 module - 2 nos. d) Tinned Copper Busbar ( 4 Bar ) each of capacity 200 Amps., 415V, 50 Hz - 1 set e) Static Multifunction panel mounting LED Energy Meter suitable for operation on 3Ph, 415V, 50Hz supply, Cl 1 with provision of RS485 having display parameters - V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh, Runhours, On hours, Phase angle, Interrupts, THD, Events ( High-Low ), Neutral Current, K Factor - 1 no. f) CT of suitable ratio for MFM - 3 nos. g) LED indication lamp for Phases and "ON & OFF" indication for operating status of breakers - 12 nos. complete with all other accessories, internal wiring by single core FRLS grade copper conductor cable of suitable size and 1100V grade along with fabrication work, cable glanding, socketing etc. ( Make - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider / C&S ) ( Make for Meter & Energy Meter - ABB / Schneider / Secure / Legrand / LK (L&T) / Genus / Conzerv / Elmeasure / Stelmec / HPL / Socomec / Anchor / C&S ) | — | 2.00 | — | — | |
| — | — | — | Above/ 6812.00 Below/P | ||
| Fixing, connection, testing and commissioning of above panel including all incoming and outgoing cables glanding, cable socketing and connection and construction of concrete foundation or suitable wall hanging arrangement as per site condition with all associated accessories | — | 2.00 | — | — | |
| — | — | — | Above/ 127325.00 Below/P | ||
| Supply of Battery Charger Unit suitable for charging of battery complete with silicon rectifier unit, naturally air cooled suitable for outdoor use including (a) Dry type main Transformer of rating 35 KVA ( Insulation Class - F ) (b) Incoming RCBO of rating 63A, 4 Pole, 300mA, 415V, 10kA (c) Outgoing DC MCCB of rating 200A, 2 Pole (d) Ammeters for input 3 phase AC current measurement and output DC current measurement (e) Voltmeters for input 3 phase AC voltage measurements and output DC voltage measurements (f) MFM with 3/4 line display and 3 nos. of CTs of suitable ratio at incoming side (g) Selector switches, LED indication lamps, HRC fuses for input and output supply and all necessary protective device like overload relay, Earthing Leakage Relay etc. of suitable capacity at an AC input : 415V, 3Ph, 50Hz and DC output : 110V - 140V, 200A including installation, connection and commissioning alongwith all incoming and outgoing cables glanding, cable socketing and connection and construction of concrete foundation as per site condition with all associated accessories. | — | 1.00 | — | — | |
| — | — | — | Above/ 9948.00 Below/P | ||
| Earthing with 2 nos.of 50 mm diametre, 3.0 metres long heavy gauge GI pipe ( Make - Tata / Jindal / Bansal ) including construction of earth pit and necessary earth connection from pit by suitable Galvanized Iron ( GI ) strip. ( For details not covered in this specifications, Indian Standard Code of Practice for earthing IS : 3043 - 1987, Reaffirmed - 1996 should be followed ) | — | 4.00 | — | — | |
| — | — | — | Above/ 700736.00 Below/P | ||
| Goods & Services Tax ( at present @ 18% ) | — | 1.00 | Lumpsum 700736.00 | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TenderBooklet.pdf
ATTACHMENT
GCC_April-2022.pdf
ATTACHMENT
Annexure-VA.pdf
ATTACHMENT
TenderFormandAnnexuresnew.pdf
ATTACHMENT
HTLTstandardspecification.pdf
ATTACHMENT
Advancecorrectionslips.pdf
ATTACHMENT
3648Clause.pdf
ATTACHMENT
Annexure-A3648.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .