| 1 | L1₹8.94Accepted-AOC | L1 | Accepted-AOC OK | |
| 2 | L1₹8.9 LRejected-Finance | L1 | Rejected-Finance OK | |
| 3 | L2₹8.9 LRejected-Finance | L2 | Rejected-Finance OK | |
| 4 | L3₹8.9 LRejected-Finance AT KAIJANGA PO SISILO BALAKATI DIST KHURDA | KHORDHA | ODISHA | 751001 | L3 | Rejected-Finance OK | |
| 5 | L4₹9.7 LRejected-Finance | L4 | Rejected-Finance OK |
Tender Value
₹10.5 L
EMD Value
₹11,000
Closing Date
28 Feb 2019, 5:00 pmClosed
EE LI DIVISION, CUTTACK
OFFICE OF THE EXECUTIVE ENGINEER LI DIVISION, CUTTACK
INSTALATION OF NEW BENUKHANDA-III SHALLOW TUBE WELL LIFT IRRIGATION PROJECTS UNDER JALANIDHI-II SCHEME in differnt block in Jagatsinghpur District.
2019_OLIC_54038_1
24/18-19
Open Tender
Civil Works - Lift Irrigation Schemes
Item Rate
365 days
JAGASINGHPUR BLOCK
Please refer Tender documents.
2 documents required · 2 mandatory
₹6,000
Yes
₹11,000
Yes
4 Mar 2022
23 Feb 2019
1 Mar 2019
23 Feb 2019
28 Feb 2019
23 Feb 2019
23 Feb 2019 - 28 Feb 2019
Amount
Schedule-B
Empty pannel board of size (110cmx45cmx25cm)made out of 20 gage CR sheet with stand made of MS angle of 20mm size with 4 nos of legs of 30cm size painting in Navy Blue colour with inscription of OLIC
XLPE Insulated( Heavy duty) armoured electric cable of size 3 core x 6.0 sq.mm with aluminium conductor for use in three phase system in working Voltage upto 1100 Volts at 50 Hz. Confirming to IS 7098 Part 1-1988 & as per the particulars mentioned .
Motor Base plate made with MS channels
100 mm dia GI socket
ISI marked High Density Polyethylene(HDPE) pipes for water supply as per IS-4984/ 1995 (Reaffirmed 2002) with amendment No. 1,2, 3,4 & 5 of material Grade PE 80, pressure rating PN 6.0 & nominal dia of 63 mm with CIPET testing.
200 mm dia T.W. Cap
8 sq mm PVC Coated steel wire rope
50 mm dia G.I. Bend confirming to IS No. 1239 (Pt-II/1992)
50 mm dia Stainless Steel threaded Nipple of 15 cm long confirming to IS No. 1239 (Pt-II/1992)
FTH G.I.Nut Bolts
Installation of submerssible pump set inside the borewell, fitting the HDPE pipe, tying the pump set with wire rope, connecting the supply line & submerssible cable with starter, fixing the panel board, completing all the electrical installations as per direction of the Engineer-in-charge.
Cost of 5HP energy efficiency bronze impeller star rated Submersible Pump set 3 phase having discharge 258 LPM at 30 mtrs. Head with flat cable.
Panel foundation with Ist class K.B. Brick massonary in C.M. (1:6) of size (75 cm x 45 cm x 60 cm) including base concrete of 7.5 cm depth in cm(1:2:4), sand filling, plastering in C.M. (1:6), curring etc. complete as per the direction of the site engineer in charge.
50 mm dia G.I. Socket confirming to IS No. 1239 (Pt-II/1992)
Pipe Earthing with No.8 GI wire using required quantity of common slat, charcoal, G.I. nuts and bolts including digging the earth pit of size 1.2mx1.2m x 3m & digging the wire trench and refilling after completion of earthing including supply of all materials
Cost of Control panel with DOL starter sheet steel enclosure suitable for operation of squirrel cage induction motor upto 5 HP having full load current of 10 Amp at 415 v + 6% - 15%, 3 phase, 50 Hz, AC supply with over load relay range 5.5-8.0 Amps to 7.0-10.0 Amps and no volt coil suitable for operation at voltage range 350-440 V. The Control panel should provide with dependable protection against overload , single phasing and short circuit .
Schedule-C
Construction of 3 phase 11 KV line as per REC standard confirming to IE Rules 1956 with 300 kg 9 M long PSC Pole with 55 Sqmm AAAC , 11 KV "V" Cross arm, with required No.of 11 KV T & C Disc. Insulators in tension point & 11 KV Pin insulators, Couping & Padding of Poles. Danger Board at each Pole, Anti Climbing Devices, Stay Set at Bending point & double stay at end point with 18 mm G.I.H.T.Stay, concreting of Stay with Anchor plate, guarding at Road crossings etc. including cost of all materials, labour transportation,inspection & commissioning etc. complete.
Construction and erection of 11 /0.4 KV , 25 KVA Double Pole mounted Substation Star rated confirming to RE Rules 1956, mounted on 2.44 Mtr. Long structure, supported in 300 kg 9 mtr long PSC pole,transformer hard channel & top channel made of 2.8 M long 100 X 50 X 6 mm M.S.Channel, Transformer belting on 2.80 M long 50 X 50 X 5 mm M.S.Angle, (all REC SPN Std.F-3) with all accessories like 3 pole 11 KV HG Fuse(F-5)& A.B.Switches(F-9) both mounted on 2.8 M long 75 X 40 X 6 mm M.S.Channel and supported by 1.0 M long 50 X 50 X 5 mm M.S.Angle, with 3 No. 11 KV Lightening Arrestors & Distribution box for 25 KVA S/S, G.I.pipe earthing with 25X5mm G.I.Flats including cost of 25 KVA 11/0.4 K.V.Transformer , 35 Sqmm 3 1/2 Core PVC Cable - 40 mtr couping & padding of Poles, Danger board at each Pole, Anti climbing Devices & all other necessary fittings i.e required size Nuts & Bolts, Brackets, Cable, Cable Sockets etc. including cost of all materials, labour , transportation complete with liasioning for testing inspection & commissioning.
Consturction of 3 Phase L.T.line as per REC standard confirming to RE rule 1956 with 200Kg BM long PSC pole support in 0.40M span with 3x35mm² +1x25 mm ² LT x LPE AB cable with coil earthing device, LT dead end clam, Suspension clamp with I hook , stay accessories such as wire insulator , clamp etc. nut bolts, alonwith concreting of poles and stay as per direction of Engineer in Charge.
Electrical installation including labour charges for control chamber wiring , fitting of all electical materials with the help of back light board including all required petty purchase materials fitting and fixing of danger board , energy meter, laying of TD cable including power supply and comissioning , etc.
CHITTA RANJAN NAYAK
M/S DILIP KUMAR SAHOO
M/S. MAMATA KANDI
TRIPURA BEHERA
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .