Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.2 LAccepted-AOC | L1 | Accepted-AOC L1 bidder lowest | |
| 2 | L2₹35.5 L+₹3.4 L (10.6%)Rejected-Finance A BLOCK 302 SHRIFAL RESIDENCY JANTANAGAR PARSHWANATH NAGAR GANDHI NAGAR GUJARAT 382424 UDYAM GJ 09 0033153 | AHMADABAD | GUJARAT | 382424 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹38.9 L+₹6.7 L (20.9%)Rejected-Finance | L3 | Rejected-Finance Other than L1 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
17 Jul 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (West) Jabalpur
Garrison Engineer (West) Jabalpur Supply Marg Post Box No. 54 Jabalpur Cantt-482001 (MP)
CLEANING AND REPAIR OF SEWAGE LINE, SEPTIC TANK, SOAK WELL AND ALLIED WORKS IN THE AREA OF AGE B/R-I UNDER GE (WEST) JABALPUR
2020_MES_353587_1
8234/E8
Open Tender
Civil Works
Item Rate
270 days
GE (West) Jabalpur
As per Tender documents
5 documents required · 5 mandatory
₹500
Yes
GE (West) Jabalpur
₹80,000
12 Sept 2020
17 Jun 2020
20 Jul 2020
17 Jun 2020
17 Jul 2020
1 Jul 2020
18 Jun 2020 - 29 Jun 2020
60 days
Amount
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth for foundation etc or for shafts, wells cesspits manholes pier holes etc not exceeding 10 Sqm on plan and not exceeding 1.5m depth in any type of soil etc complete all as specified and directed
Ditto all as per above items but depth exc 1.5m but not exc 3.0 m etc complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
Removal of excavated materials to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting points etc complete all as specified and directed
Returning, filing in, excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 25cm etc complete all as specified and directed
Demolition and breaking up drain pipe (salt glazed ware, AC or reinforced concrete ) set in cement mortar for 100 mm internal dia of pipe complete all as specified and directed.
Demolition and breaking up drain pipe (salt glazed ware, AC or reinforced concrete ) set in cement mortar for 150 mm internal dia of pipe complete all as specified and directed.
Demolition and breaking up drain pipe (salt glazed ware, AC or reinforced concrete ) set in cement mortar for 200 mm to 300 mm internal dia of pipe complete all as specified and directed.
M&L for cement concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid & tested for 100 mm bore of pipe with cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregate complete all as specified and directed.
M&L for cement concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid & tested for 150 mm bore of pipe with cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregate complete all as specified and directed.
M&L for cement concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid & tested for 200 mm bore of pipe with cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregate complete all as specified and directed.
M&L for SGSW drain pipes grade 'A' laid in trenches of 100 mm Internal diameter of pipe and jointed as specified complete as specified and directed.
M&L for SGSW drain pipes grade 'A' laid in trenches of 150 mm Internal diameter of pipe and jointed as specified complete as specified and directed.
M&L for SGSW drain pipes grade 'A' laid in trenches of 200 mm Internal diameter of pipe and jointed as specified complete as specified and directed.
Demolition of cement concrete un-reinforced in ground floor and paving including floor tiles n.exc 15cm thick (below or above ground level) complete all as specified and directed.
Demolition of brick or stone boulder masonary work built in cement & sand mortar including all quoin, arches, pillars etc & removing rubbish from site complete all as specified & directed.
M&L for Brick work using old size bricks with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in cement sand mortar in 1:6 complete all as specified and directed.
M&L for Brick work using old size bricks with sub class 'B' bricks in one brick thick honey comb walling built in cement sand mortar in 1:4 complete all as specified and directed.
Taking down cement plaster any description on brick or stone walls and including wall tiles with mortar etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:4 on external concrete wall surfaces finished even and smooth using extra cement with Water proofing compound. Note : Water Proofing compound shall be measured and paid seperately.
M&L for rendering on fair faces of brick work or concrete surface of wall 15mm thick in CM 1:6 and to be finished even and smooth without using extra cement complete all as specified and directed
Demolition of any type reinforced cement concrete in any position complete as specified & direted.
M&L for Precast cement concrete M20 using 20 mm graded crushed stone aggregate as in landings, cover slab (for manholes etc) and similar work including necessary form work and set in CM 1:6 complete all as specified and directed.
S&F TMT bar 6 to 8mm dia cut to length bent to shape required including cranking, bending spirally for hooping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete as specified & directed.
Supply only Integral water proofing compound
S&F in repair for PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors of 110 mm bore of pipe complete as specified and directed.
S&F in repair for PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors of 75 mm bore of pipe complete as specified and directed.
S&F in repair PVC (SWR) bends ISI marked any radius of 110 mm bore complete all as specified and directed.
S&F in repair PVC (SWR) bends ISI marked any radius of 75 mm bore complete all as specified and directed.
S&F in repair PVC (SWR) junction single, (double T) equal or un equal of 110 mm bore with access door of pipe complete all as specified and directed.
S&F in repair PVC (SWR) junction single, (single T) equal or un equal of 75 mm bore with access door of pipe complete all as specified and directed.
S&F in repair PVC (SWR) vent cowl ISI marked 110 mm bore complete all as specified and directed.
Cutting of grass, growth/vegetations, bushes or like and similar work and making the workable space for carrying out cleaning of sewage line/manholes in any location or condition all as specified and directed by Engineer-in-Charge
M&L for Cutting opening around floor trap(wall junction ) nahani trap and repairing joint leaking using cement slurry include replacing the damaged traps and making good the surface to match with adjoining area and ensure leak proof joint etc all as specified and directed by Engineer-in-Charge
M&L for repairs to existing leakage of pipe joints of CI,AC,and PVC pipes by cutting out leakage portion and refitting the same with cement or solvent and ensure leak proof joints /junctions of any bore of pipe etc all as specified and directed by Engineer-in-Charge
Cleaning of septic tank by removing septic tank cover , pumping out fluid, removing, sludge/sediments by mechanical means, transporting the fluid/sludge etc in covered containers by manually or mechanically and burying the same in pits where directed including necessary excavation refill and disposal of surplus soil etc complete, cleaning of septic tank with water placing the covers intact, removing bush/ vegetation near by septic tank to an extent of 3 mtrs around all as directed by engr-in-charge.
Up to 100 User Septic tank Capacity
More than 100 user and up to 400 User septic Tank Capacity
Cleaning of manholes by removing MH covers, removing of accumulated liquid, sludge/sediments by mechanical means, transporting the fluid/sludge etc in covered containers by mannually/mechanically and burying the same in pits a way from domestic premises, where directed including necessary excavation refill and disposal of surplus soil etc complete, cleaning with fresh water, placing the MH covers intact in position etc all as directed by Engr-in-charge.
Manhole depth not exe 1.0m
Manhole depth exe 1.0m not exe 2.0m
Manhole depth exe 2.0m
Cleaning of all blockages in sewer line of any type and dia of sewer lines, manholes of any section and any depth, in any situation by way of cleaning/desludging foreign materials manually/mechanically including desludging where required and as ordered by Engr-in-Charge and keeping sewer line functional from floor traps, water closet, soil waste/vent pipe, gully trap upto final drop /outlet into septic/central sewage system terminating in other joining zone/area or into sewage well complete all as specified and directed.
Note : Contractor should be deployed minimum Five Team with T&P and mechanical equipments shall be provided by contractor on each working day for 08 hours per day to clear the blockage of sewage line/manhole on day to day complaint basis by users. and Area are following:- (1) Surendra Enclave, Raghbi Ground, Mall road, Cobra Mess and interconneted areas (2) thammiya Manson ,DSOI,Swimming pool, GOC House, Station GYM, Kerily Enclave, Station cell, (3) HQ MB Area ,2TTR, Cobra canteen, Robbert Berrack.,Signal comany,Cobra canteen,MM line (4) Vikram Batra ,Vinay Rao Enclave, Adhikari Enclave (5) Mainkshaw, MES Colony, Sardar Mess, RTZ Zone Note:- (a) Contractor shall detail his supervisor to office of AGE B/R 1 daily by 9.00 AM who will report to concerned JE Civil or Engineer-in-Charge to receive all complaints of entire area under this contract. (b) Contractor shall provide service providers (sweepers) as per the complaints list given alongwith all requisite tools, equipments, including safely measures for attending complaint and ensure completion report by 5.00 PM same day. (c) Please note that all the complaints relating to sewage line shall be attended within same day (within 12 hour). In case of blockage in sewage line could not be detacted / completed on same day and concerned JE or Engineer-in-Charge is satisfied to the efforts applied but the same shall be attended and all blockage must be cleared by 24 hours (next day by 5.00 PM) without fails. (d) In case any complaint pertaining to clearing of blockage in sewage line is not removed / cleared within 24 hours (next day 5.00 PM). A penalty @ Rs. 200/- per complaint per day shall recovered from contractor payments. (e) Blockage cleared between two man holes irrespective of length in between shall be treated as one complaint.
M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in surface channels and drains complete etc all as specified and directed.
M&L for Precast cement concrete block soild blocks PCC 1:2:4 type B-1 using 20 mm aggregated masonry with exc 10 cm in width and setting in cement mortar 1:4 complete all as specified and directed.
M&L for Brick work using old bricks with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:4 complete all as specified and directed.
M&L for broken bricks of guage not exceeding 63mm for loose fillling in soakage pit, soakage wells complete all as specified and directed
M&L for Birck work with fly ash bricks of compressive strength not less than 75 Kg/sqcm, straight or curved on plan exc 6 metre mean radius built in cement mortar (1:6) complete all as specified and directed.
Supply, laying and jointing 150 mm nominal bore dia DWPC (HDPE double wall corrugated), socketed and sewage pipes having 6.0 M length, conforming to IS 16098 (Part-2) of SN-4 Stiffiness with and including necessary jointing materials etc complete all as specified and directed. Make : Supreme /Sintex or equivalent as approved by GE.
Supply, laying and jointing 200 mm nominal bore dia DWPC (HDPE double wall corrugated), socketed and sewage pipes having 6.0 M length, conforming to IS 16098 (Part-2) of SN-4 Stiffiness with and including necessary jointing materials etc complete all as specified and directed. Make : Supreme /Sintex or equivalent as approved by GE.
Supply, laying and jointing 300 mm nominal bore dia DWPC (HDPE double wall corrugated), socketed and sewage pipes having 6.0 M length, conforming to IS 16098 (Part-2) of SN-4 Stiffiness with and including necessary jointing materials etc complete all as specified and directed. Make : Supreme /Sintex or equivalent as approved by GE.
S&F in repair health faucet C. P. jet spray with P.V.C chord and connector of suitable length complete Make :-Jaguar Cat Part No ALD-CHR-573
S&F framed work such as grills, gratings, etc with ends of bars shouldered and/ or rivered, or forged into spikes, framed guard bars, barred iron doors, framed bausters, walk ways, railing, framewiork of water tanks and similar work con forming to Fe 290 Gde-E-165.
M&L for Fromwork to soffits of Suspended slab such as roof slab,floor slabs landing and similar work not exceeding 200 mm thickness as directed by Engr-in-Charge
M&L for RCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in slab supported on wall, beam and column in floors, roofs, landings, balconies, canopies and in shelves and similar work complete all as specified and directed.
M&L for Repairing sunken floor leakage by taking out existing nahani trap/floor traps carefully by digging out from its position and provision of new PVC (SWR) nahani trap n .exc 100mm dia and joining the same to existing waste pipe of any dia and ensure leak proof joints including making good the adjoining area to match with existing floor tiles etc with PVC NT/FT grating, complete all as specified and as directed .
M&L for PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed
M/S CENTRAL REFRIGERATION AND ELECTRICALS
SR ASSOCIATES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .