Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹56,307
Closing Date
7 Jan 2025, 3:00 pmClosed
EE(E)HN
T.E building Hari Nagar, New Delhi.
Repairing of package/ductable AC units at various RSU/TE Buildings under EE (Elect.) HN, MTNL New Delhi.
2024_MTNL_841935_1
EE(E-W)/MTNL/2024-25/28
Open Tender
Miscellaneous Works
Item Rate
365 days
New Delhi
As per Web NIT
9 documents required · 9 mandatory
₹590
Yes
MTNL Delhi
₹56,307
Yes
16 Jan 2025
30 Dec 2024
8 Jan 2025
30 Dec 2024
7 Jan 2025
30 Dec 2024
Dismantling of old ductable/Package AC units (4 TR/ 5 TR/5.5TR/7.5TR/ 8.5TR/ 8.75TR/11TR) with the help of chain pully block & heavy labour etc as required.
Lifting & shifting of A.C Units with the help of heavy labour & chain pully block from ground floor to the floor where the A C plant room is situated complete as reqd.
Shifting of dismantled AC Unit along with all accessories to another site under jurisdiction of EE(E) HN with the help of heavy labour and chainpully, transportation etc. as reqd.
Providing and making drain arrngement for AC units with following pipes i/c Tee, Union, Socket & elbow etc as required. a) 25 mm dia medium class PVC pipe
b) 38 mm dia medium class PVC pipe
Supply & fixing of site fabricated rectangular type G.I. sheet metal ducting i/c air mixing, air distribution system, complete thickness gauge i/c nut bolts & gasket etc. as required. a) 24 gauge G.I. Sheet
b) 22 gauge G.I. Sheet
c) Canvass connection with fire ressistance coth complete as reqd.
Pdg. & installing following size copper pipe including cutting bending, jointing, brazing etc as reqd. for hot and liquid refrigerant line complete as reqd. a) 6/8"
Providing and fixing of 6mm thick cross linked polyethylene insulation for drain / copper piping in order to protect it from air borne impurities complete as reqd. as per site location.
Supplying and fixing of PVC insulated PVC sheathed/XLPE insulated copper conductor cables of 1.1KV grade of following sizes on the existing M.S. trays/walls with saddles, screws etc and end terminations of cables with glands etc. as required. a) 4 x 6 Sq.mm copper armoured cable
b) 4 x 10 Sq.mm copper armoured cable
c) 3 x 1.5 Sq.mm copper conductor flexible cable
d) 4 x 2.5 Sq.mm copper conductor flexible cable
e) 18C x 2.5 Sq.mm copper armoured cable
f) 3C x 2.5 Sqmm Copper flexible cable
Pressure testing with nitrogen, pressure standing for at least 8 hr.,vaccumzing & commissioning with refrigerant of following AC Unit complete as reqd. a) 11TR/10TR/8.5TR (nominal capacity) type AC Unit
b)7.5TR/ 5.5TR/4.0TR (nominal capacity) AC Unit
c) 2 TR/1.5TR AC Unit
d) R-22 gas charging/ gas top up
e) R-407 gas charging/gas top up
f) R-410A/R-32 gas charging/gas top up
Replacement of new coil (Condenser coil) of following a.c. Units including dismantling the faulty coil and making proper size copper pipe connection brazing at joints etc. as required. Old coil will be the property of contractor. (a) 1.5TR to 2.0 TR A.C Unit
(b) 2.5 TR to 3.0 TR A.C. Unit
(c) 4.0 TR A.C Unit
(d) 5.0 TR to 5.5 TR A.C. Unit
(e)7.0TR to 7.5 TR A.C Unit
(f) 8.5 TR to 9.0 TR A.C. Unit
g) 11.0 TR A.C. Unit
Replacement of new coil (Evaporator coil) of following a.c. Units including dismantling the faulty coil and making proper size copper pipe connection brazing at joints etc. as required. Old coil will be the property of contractor. (a) 1.5 TR to 2.0 TR A.C Unit
(b) 2.5 TR to 3.0 TR A.C. Unit
(c) 4.0 TR A.C Unit
(d) 5.0 TR/ 5.5 TR A.C. Unit
(e) 7.0 TR to 7.5 TR A.C. Unit
(f) 8.5 TR to 9.0 TR A.C. Unit
(g) 11.0 TR A.C. Unit
Replacement of faulti mechanical item of package/ductable AC Unit & other works complete as reqd. a) Angle valve/pin valve for ref. circuit. (old material shall be the property of contractor)
b) Drier filter for AC Unit
c) Puller block bearing blower shoft size 1 inch
d) 2.5 TR refurbished compressor suitable for Carrier/BSL/LG/Voltas/ Hitachi make twin ckt 5.0TR AC Unit (Make : Carrier/Kirloskar/ Copeland)
e) 3.75TR /5.5TR refurbished compressor suitable for Carrier/BSL/LG/ Voltas/ Hitachi Make 7.5TR/ 11.0TR AC Unit (Make : Carrier/Kirloskar/ Copeland)
f) V-belt for package AC units
g) Contactors for compressor/blower (upto 25amps) for package AC units including electrical connections
h) VSP D1 ( Minilec ) 415 V relay of compressor/blower for package / Ductable AC units
i) LP Switch/HP Switch for package/ductable AC units
j) Package AC unit controller card/PCB
k) Digital ampere meter for Package AC/Ductable AC units
l) Remote for Ductable AC units ( 4.00 Tr to 11.0 TR)
Rewinding of old defective blower motor of 7.5TR AC Unit
Replacement of rewound condenser fan motor for AC Unit
Replacement of condenser motor capacity of 8MFD
Replacement of condenser fan for 7.5TR/5.0TR Unit
Replacement of blower fan of 7.5TR/5.0TR Unit
Pdg. & fixing of electrical/mechanical switchgears complete as reqd. a) 63amp TPN MCB
b) 100amp TP MCCB of 25KA Breaking capacity (Make-M/s L&T/GE/Legrand/ C&S/ABB)
Chemical servicing of ductable/packages with the help of water & chemical of outdoor a.c. Unit.
Fabricating & installing of following tray made out with following M.S. Slotted angle & squire pipe or slotted sheet material i/c nut bolt, screw, etc. as reqd. a) 150mm wide M S slotted trey
b) 225 mm wide M S slotted trey
Minor civil works such as making opening in brick wall/RCC walls/slabs for AC units for refrigerant piping, ducting, cabling as per site requirement, making good the same for sealing the opening after associate work complete as required.
Supplying, Laying & fixing of 8 SWG GI earthing wire on the existing surface/recess for loop earthing with main power cable complete as required.
Supplying and fixing of synthetic fibre media washable filters with frame ( Efficiency 90% down to 20 microns ) for 5.0 TR to 11.0 TR )
Less credit for dismantled material and dismantled material shall be the property of contractor.
M/s Super Maintenace and Services (BID ID -3148430)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .