| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.6 LAccepted-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L1 | Accepted-AOC L1 Rate Satisfactory | |
| 2 | L2₹18.9 L+₹1.9 L (11.3%)Rejected-Finance FLAT NO 401 TULSANI HEIGHTS 4TH FLOOR GREEN PARK SOCIETY AKURDI GURUDWARA TO WALHEKAR WADI ROAD CHINCHWAD PUNE 411033 | PUNE | MAHARASHTRA | 411033 | L2 | Rejected-Finance Greater Than L1 | |
| 3 | L3₹23.5 L+₹6.5 L (38.5%)Rejected-Finance MAYURESH BHARAT CHS PLOT NO 170 181 B 09 SECTOR 21 NERUL NAVI MUMBAI 400706 | THANE | MAHARASHTRA | 400706 | L3 | Rejected-Finance Greater Than L1 |
| Sl No | Description | Qty | Unit | Shree Ayyappa Engineering L1 | ECOBUILD L3 | SHAILENDRA B TULSANI L2 |
|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr deep and getting out in soft loose soil all as specified and directed by Engineer -in-Charge.
Note for item No 1 to 86 : BOQ items specified should be done by the contractor as and when required on call at any time by I/C JE E/M / Engineer-in-Charge, failing which contractor should be penalise by Rs 200 per hours for complete delayd time. | 22.5 | CUM | 300 ₹6,750 | 280 ₹6,300 | 270 ₹6,075 Lowest |
| 2.00 | Excavation by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soft/ disintegrated and disposal of surplus excavated soft/ disintegrated as directed by Engineer -in-Charge , within a lead of 50 m all as specified and directed by Engineer -in-Charge . | 11.7 | CUM | 400 ₹4,680 | 775 ₹9,067.5 | 350 ₹4,095 Lowest |
| 3.00 | Returining, filling in including spreading, levelling watering and well ramming in layer not exce 25 cm, all as specified and directed by Engineer -in-Charge | 30.68 | CUM | 100 ₹3,068.38 | 75 ₹2,301.28 | 60 ₹1,841.03 Lowest |
| 4.00 | Removing excavated soil to a distance not exce 50 mtr and deposited where directed by Engineer -in-Charge at a level not exceding 1.5 mtr abvoe the starting point all as specified and directed by Engineer -in-Charge . | 3.52 | CUM | 200 ₹703.24 | 200 ₹703.24 | 80 ₹281.3 Lowest |
| 5.00 | Taking down unserviceable GI pipe line of following size from the trenches by removing of GI fitting of following sizes
(a) 15 mm dia | 60 | RM | 15 ₹900 Lowest | 22 ₹1,320 | 15 ₹900 Lowest |
| 6.00 | All as per item No 5 here-in-before (b) 20 mm dia | 50 | RM | 15 ₹750 Lowest | 24 ₹1,200 | 20 ₹1,000 |
| 7.00 | All as per item No 5 here-in-before (c) 25 mm dia | 40 | RM | 15 ₹600 Lowest | 35 ₹1,400 | 25 ₹1,000 |
| 8.00 | All as per item No 5 here-in-before (d) 40 mm dia | 25 | RM | 15 ₹375 Lowest | 48 ₹1,200 | 30 ₹750 |
| 9.00 | All as per item No 5 here-in-before (e) 50 mm dia | 15 | RM | 20 ₹300 Lowest | 45 ₹675 | 30 ₹450 |
| 10.00 | S & F GI tubing medium grade with all new connections and fittings such as tees, bends, elbows, short pieces, connector back nuts, diminishing pieces, caps, plugs unions etc Laid in trenches for following size of pipes complete all as specified and as directed by Engineer -in-Charge
(a) 15 mm dia | 60 | RM | 200 ₹12,000 Lowest | 250 ₹15,000 | 206 ₹12,360 |
Tender Value
₹24 L
EMD Value
₹48,000
Closing Date
7 Aug 2025, 6:00 pmClosed
Gaurav Tiwari, IDSE
GE (I) (NAVY), INS SHIVAJI - POST, LONAVLA -410402
REP MAINT OF CORRODED RAISING MAIN DISTRIBUTION CI GI PIPE LINE AND PUMP MOTORS PANEL AND CONNECTED ACCESSORIES AT PRATAP NAGAR AREA, SMQ AREA BOSON STORE AREA WATER SUPPLY SCADA AND NSB AREA AT INS SHIVAJI LONAVLA
2025_MES_719394_1
GE/LONAVLA/8341/E8
Open Tender
Civil Works
Item Rate
180 days
GE (I) (NAVY) LONAVLA
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE (I) (NAVY) LONAVLA
₹48,000
Yes
8 Nov 2025
9 Jul 2025
9 Aug 2025
9 Jul 2025
7 Aug 2025
24 Jul 2025
9 Jul 2025 - 23 Jul 2025
Amount
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr deep and getting out in soft loose soil all as specified and directed by Engineer -in-Charge. Note for item No 1 to 86 : BOQ items specified should be done by the contractor as and when required on call at any time by I/C JE E/M / Engineer-in-Charge, failing which contractor should be penalise by Rs 200 per hours for complete delayd time.
Excavation by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soft/ disintegrated and disposal of surplus excavated soft/ disintegrated as directed by Engineer -in-Charge , within a lead of 50 m all as specified and directed by Engineer -in-Charge .
Returining, filling in including spreading, levelling watering and well ramming in layer not exce 25 cm, all as specified and directed by Engineer -in-Charge
Removing excavated soil to a distance not exce 50 mtr and deposited where directed by Engineer -in-Charge at a level not exceding 1.5 mtr abvoe the starting point all as specified and directed by Engineer -in-Charge .
Taking down unserviceable GI pipe line of following size from the trenches by removing of GI fitting of following sizes (a) 15 mm dia
All as per item No 5 here-in-before (b) 20 mm dia
All as per item No 5 here-in-before (c) 25 mm dia
All as per item No 5 here-in-before (d) 40 mm dia
All as per item No 5 here-in-before (e) 50 mm dia
S & F GI tubing medium grade with all new connections and fittings such as tees, bends, elbows, short pieces, connector back nuts, diminishing pieces, caps, plugs unions etc Laid in trenches for following size of pipes complete all as specified and as directed by Engineer -in-Charge (a) 15 mm dia
All as per item No 10 here-in-before (b) 20 mm dia
All as per item No 10 here-in-before (c) 25 mm dia
All as per item No 10 here-in-before (d) 40 mm dia
All as per item No 10 here-in-before (e) 50 mm dia
Supply and fix in replacement Gun metal Globe or Gate valve with iron wheel head, screwed both ends for GI pipe and fixed with required necessary GI fittings complete of size (a) 20 mm dia
All as per item No 15 here-in-before (b) 25 mm dia
All as per item No 15 here-in-before (c) 40 mm dia
All as per item No 15 here-in-before (d) 50 mm dia
All as per item No 15 here-in-before (e) 15 mm dia
M & L for disconnecting carefully and dismantling the pump set from motor unit and opening complete pump set, cleaning replacing of unserviceable parts such as gun metal bushes, rubber packing, MS Nut, Bolts, rubber coupling (spider), Air valve and worn out parts etc and reassembling, re-installing commissioning and testing for satisfactory running complete all as specified and as directed by Engineer -in-Charge for following capacity of pumps :- Note :- Spare parts replaced shall be measured and paid separately as "Supply only" Centrifugal pump set of 60 HP capacity.
All as per item No 20 here-in-before but Centrifugal pump set of 50 HP capacity.
All as per item No 20 here-in-before but Centrifugal pump set of 30 HP capacity.
All as per item No 20 here-in-before but Centrifugal pump set of 25 HP capacity.
All as per item No 20 here-in-before but Submersible pump set of 10 HP capacity
All as per item No 20 here-in-before but Submersible pump set of 5 HP capacity
M & L for overhauling of motor unit, 3 phase, 415 volts by dismantling and opening completely, cleaning internal parts thoroughly, replacing unserviceable minor parts like nut bolts, washers, terminal plate, cable lugs, greasing including insulating materials, varnishing, heating, reassembling reinstalling and testing complete all as specified and as directed by Engineer -in-Charge for the following capacity of motor :- Note:- Unit rate quoted shall be deemed to include for minor unserviceable parts as mentioned/ required for repairs. All other major spares as specified hereinafter will be measured and paid separately as "Supply only". Centrifugal pump set of 60 HP capacity.
All as per item No 26 here-in-before but Centrifugal pump set of 50 HP capacity.
All as per item No 26 here-in-before but Centrifugal pump set of 30 HP capacity.
All as per item No 26 here-in-before but Centrifugal pump set of 25 HP capacity.
All as per item No 26 here-in-before but Centrifugal Mono block pump set of 15 HP capacity.
All as per item No 26 here-in-before but Submersible pump set of 10 HP capacity
All as per item No 26 here-in-before but Submersible pump set of 5 HP capacity
M & L for rewinding electric motor by dismantling from cable connection pump set and foundation, dismantling complete motor removing all parts thoroughly removing burnt copper wire with new one and rewinding motor 3 phase 415 with same gauge, same No of turns of super enamel copper wire including E class insulating material, varnishing, heating etc re-installing and testing etc complete all as directed by Engineer -in-Charge for the following capacity:- Note :- Unit rate quoted shall be deemed to include for minor unserviceable parts as mentioned/ required for repairs. All other major spares as specified hereinafter will be measured and paid separately as "Supply only". Centrifugal pump set induction motor of 60 HP capacity.
All as per item No 33 here-in-before but Centrifugal pump set induction motor of 50 HP capacity.
All as per item No 33 here-in-before but Centrifugal pump set induction motor of 30 HP capacity.
All as per item No 33 here-in-before but Centrifugal pump set induction motor of 25 HP capacity.
All as per item No 33 here-in-before but Centrifugal Mono pump set induction motor of 15 HP capacity.
All as per item No 33 here-in-before but Submersible pump set induction motor of 10 HP capacity
All as per item No 33 here-in-before but Submersible pump setinduction motor of 5 HP capacity
Supply only brass impeller set suitable for following capacity centrifugal pump set . For 60 HP Capacity
All as per item No 40 here-in-before but For 60 HP Capacity
All as per item No 40 here-in-before For 30 HP Capacity
All as per item No 40 here-in-before For 25 HP Capacity
Supply only pump shaft suitable for centrifugal/ monoblock pump set for following capacity of motors For 50 HP to 30 HP Capacity
All as per item No 44 here-in-before For 25 HP to 10 HP Capacity
Supply only ball bearing suitable for centrifugal pump set of following capacity of pump set. For 60 HP Capacity
All as per item No 46 here-in-before For 30 HP Capacity
All as per item No 46 here-in-before For 25 HP Capacity
Supply only bush for main shaft drive suitable for pump set of following capacity . Centrifugal pump set of 60 HP capacity.
All as per item No 49 here-in-before but Centrifugal pump set of 30 HP capacity.
All as per item No 49 here-in-before but Centrifugal pump set of 25 HP capacity.
All as per item No 49 here-in-before but Centrifugal pump set of 5 HP capacity.
S&F in replacement MCCB TP 400 Amp capacity, 36 KA including disconnecting incoming cable, replacement of worn out lugs, crimping with new lugs including exacavation requried for open loop of cable complete all as specified and as directed by Engineer -in-Charge . Make:-Legrand DPx3 630
All as per item No 53 here-in-before but capacity 200A Make:-Legrand,Merlin Gerin
S&F in replacement fully automatic star delta starter type ML-6 - FASD including timer, over load relay, single phase preventor, required wiring etc complete all as specified and as directed by Engineer -in-Charge . Make:L-K
S&F in foot valve of size 80 mm dia complete, Ball type (Brass) all as specified and as directed by Engineer -in-Charge .
S&F in replacement of Non return butterfly valve of size 150mm dia complete all as specified and as directed by Engineer -in-Charge .
S&F in replacement of Non return sluice valve type of size 100 mm dia complete all as specified and as directed by Engineer -in-Charge .
All as per item No 58 here-in-before but of size 80 mm
S&F in replacement of butterfly valve of size 150mm dia complete all as specified and as directed by Engineer -in-Charge .
Supply laying and testing cable XLPE insulated screened beded,galvanized steel trip or wire armoured, electric power cables (heavy duty) 1100 Volt grade wiyh stranded aluminium conductor of size 300 sq mm 3.5 core. Including taking down old unserviceable cable any size by dismantling of all electrical connection etc all as diercted by Engineer-in-Charge.
Excavation in trenches not exc. 1.5m wide and not exc 1.5m in depth and getting out in soft/loose soil for laying of cable trenches all as specified and directed by Engineer -in-Charge .
All as per item No.22 Herein before but in hard dense soil
Returning filling in, including spreading, levelling, watering and well ramming in layer not exc 25cm for cable all as specified by Engineer -in-Charge .
Removal of surplus soil (excavated soil) to distance not exceeding 50m and depositing where directed by Engineer -in-Charge at a level not exc 1.5m above the starting point for cable and all specified by Engineer -in-Charge .
M&L for providing dry river sand / crush stone dust for cushioning to UG cable including punning down of sand in layers all as specified. Note :- Cushioning will be measured and paid after punning down.
Supply and laying factory cast, unreinforced precast concrete cable cover factory made embossed the mark “LT CABLE” class LV type1 flat size 250x150x40 mm laid in trenches as specified and as directed by Engineer -in-Charge .
S&F in replacement, contactor Type, ML-6, AC3-110A Amps complete all as specified and as directed by Engineer -in-Charge .
All as per item No 68 here-in-before but of size ML-3, AC3-40 A Amps
All as per item No 68 here-in-before but of size ML-2, AC3-32 A Amps
All as per item No 68 here-in-before but of size ML-1.5, AC3-25 A Amps
All as per item No 68 here-in-before but of size MNX 70 AC3-70 A Amps
All as per item No 68 here-in-before but of size MNX 50 AC3-50 A Amps
S & F in replacement star delta timer, operation voltage 230-415 Volt, 50 Hz complete all as specified and as directed by Engineer -in-Charge .
S & F in replacement Single Phase Preventor operation voltage 230-415 Volt, 50 Hz complete all as specified and as directed by Engineer -in-Charge .
S& F in replacement push button (red,green)for motor complete all as specified and as directed by Engineer -in-Charge .
All as per item No 76 here-in-before but of color yellow
S&F in replacement 3 Phase digital/analogue Volt meter, 0 to 500 Volt, complete all as specified and as directed by Engineer -in-Charge .
S&F in replacement 3 phase digital/analogue Ammeter meter, 0 to 150 Amps with CT coil of ratio 5/50 complete all as specified and as directed by Engineer -in-Charge .
Cutting of road /hard standing for laying /dismantling of pipe line and making good surfaces matching with the existing surface after laying of pipe line.up to 30 cm by means of concrete after leveling of road.
S&F Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. cut to ordinary lengths i.e. within 20mm of the length indicated ( Fe-410-W(Gde-E-250) quality-A.
Area clearance/levelling/excavation /digging at MES installations at any width and length by using JCB complete all as directed by Engineer -in-Charge by Engineer-in-Charge. Note 1. The cost of POL includedin quotated rates . 2. After Start and finsh of the work ,Hrs slips shall be provided by the contrcator 3. LOG Sheet shall be maintained.
Supply and fix in repair and replacement of actuator which consists of motor,gear box assembly and electrical and electronic contacts of size 200mm dia.Motorized Butterfly valve (20 Kg/N to 30 Kg/N) complete all as specified and as directed by Engineer -in-Charge . Make Cat No. UNIVERSAL (U-200/16/220VAC) or equivalent in ROTORK, EMERSON
M & L for proper reinstallation of dismantled three nos solar cum electric water heaters of capacities 200 ltrs each at shivalik block terrace which includes the 50 x 50 x 6 mm angle base for placement of water heaters, angle iron support with proper welding, electrical connections ,electric heating element of existing size & capacity and thermostat with suitable wiring, connected water inlet and out let PVC/GI lines of the water heater and also including the testing the solar cum electric water heater after installation for required heating temperatures..etc.all as directed by Engineer -in-Charge and specified by the Engr-in - Charge.
SHAILENDRA B TULSANI (BID ID -3378894)
ECOBUILD (BID ID -3378718)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .