VIJAY NEHRA
GE SATWARI
REPAIR MAINT OF SECURITY LIGHTS, STREET LIGHTS AND CONNECTED ITEMS AT Y STN, RIDGE, BWR, SAG UNDER GE SATWARI
2021_MES_427071_1
GEJM-01/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE SATWARI
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE SATWARI
₹60,000
Yes
27 Apr 2021
3 Mar 2021
31 Mar 2021
3 Mar 2021
29 Mar 2021
22 Mar 2021
Amount
Dismantling PCC 1:2:4 with making good surface complete all as specified and directed
Excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes,cables,pipe line,pole etc. not exceeding 10 Sqm on plan and not exceeding 1.5 mtr in depth and getting out, in any type of soil, complete all as specified and as directed by Engineer-In-Charge.
Removing excavated surplus soil to a distance not exceeding 50 m away and depositing where directed at a level not exceeding 1.5 m from the starting point complete all as specified and directed .
Returning filling in, trenches including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in any type of soil complete all as specified
Supply and spreading dry river sand in trenches for cushioning of cable 8 cm layer before laying the cable and 15cm thick layer after laying the cable. Note-Sand layer shall be paid for 18 cm only after well pressed.
Supplying and laying dry bricks in trenches over under ground electric cable for mechanical protection with width equal to length of bricks with well burnt sub class ‘B’ old size bricks laid flat complete.
Taking out old bricks from excavated trenches, full bricks to be kept in safe custody for reuse at site.Broken bricks shall be removed by contractor at no extra cost to low lying area.
Relaying full bricks retrieved from srl item no 7 above for cable protection all as specified and directed.
Taking out serviceable/unserviceable XLPE LT cable aluminum conductor of size 6 to 16 sqmm 2/4 core from excavated trench/pole/over ground etc and retreived material to store kept in safe custody for reuse at site or for taking credit of cable to be replaced with new one all as specified and directed. Excavation and return filling will be paid saperately.
Relaying of healthy cable of any size retrived from srl item no 9 above after repair, making proper jointing and making connection using thimbles/lugs of suitable size as required at site.
Taking out GI protection pipe from the pole /passsing through road/existing treanches for reuse at site or for taking credit of pipe to be replaced with new one all as directed
Relaying of GI pipe for cable protection intrenches/road/pole all as specified and directed.
S&F in replacement of XLPE insulated armoured heavy duty electric cable with aluminium conductor stranded of size 6 Sqmm 2 core. Make : KEI/Havells/Gloster
S&F in replacement of XLPE insulated armoured heavy duty electric cable with aluminium conductor stranded of size 10 Sqmm 2 core.Make : KEI/Havells/Gloster
S&F in replacement of XLPE insulated armoured heavy duty electric cable with aluminium conductor stranded of size 16 Sqmm 2 core. Make : KEI/Havells/Gloster
Material and labour heat shrinkable straight through joint suitable for LT cable of size 6 to 16 sqmm 2 core. Make BIRLA 3M, Reychem, M seal
S&F in replacement of GI pipe light grade 40mm bore for cable protection.Make-Jindal, TATA , Prakash surya
Material and labour in replacement of unserviceable street light bracket made out of GI pipe 1.2 mtr long 40mm dia medium grade bent to shape as directed including MS clamps made out of 25mmX3mm flat iron for fixing bracket suitable for PCC/ street poles including nuts and bolts of required size all as directed incl taking down of old unsv bkt.Make-Jindal, TATA , Prakash surya
Material and labour in replacement of unserviceable street light bracket made out of GI pipe 1.0 mtr long 25mm dia medium grade bent to shape as directed including MS clamps made out of 25mmX3mm flat iron for fixing bracket suitable for PCC/ street poles/wall including nuts and bolts, washers, fasteners as required at site all as directed incl taking down of old unsv bkt.Make-Jindal, TATA , Prakash surya
Supply and fix in replacement surge protection device of 10 KV rating compatible with industrial and outdoor fittings with rated power upto 150 w all as specified and directed. Jaquar/Crompton/Havells
Material and labour in replacement for LED Street light 25W LED, driver and LED compartment should be seperate forwattage above 25 watt, for easy maintenance driver compartment should be opened from top, Driver=potted and incapsurated. SPD 4 KV internl and 10 KV external with 440 volts compliance for 24 hrs, Lumen efficacy=120 lm/watt, IP 66, IK07, IR protection 1.5 KV, THD<10%, Power factor>0.95, CRI (RA)>70, LED chip should be high power >1 watt, LED driving wattage (1-3 watt), Secondary optics, PC lens pasted and vetted on MCMCB with aluminium pressure die-cast housing including electronic driver 25W LED 3000K, Make : Jaquar Cat Part No LSRTTOS025XW and equivalent in Phillips and OSRAM.
Material and labour in replacement for LED Street light 25W LED, driver and LED compartment should be seperate forwattage above 25 watt, for easy maintenance driver compartment should be opened from top, Driver=potted and incapsurated. SPD 4 KV internl and 10 KV external with 440 volts compliance for 24 hrs, Lumen efficacy=120 lm/watt, IP 66, IK07, IR protection 1.5 KV, THD<10%, Power factor>0.95, CRI (RA)>70, LED chip should be high power >1 watt, LED driving wattage (1-3 watt), Secondary optics, PC lens pasted and vetted on MCMCB with aluminium pressure die-cast housing including electronic driver 25W LED 6000K, Make : Jaquar Cat Part No LSRTTOS025XC and equivalent in Phillips and OSRAM.
Material and labour in replacement for LED Street light 30W LED, driver and LED compartment should be seperate forwattage above 25 watt, for easy maintenance driver compartment should be opened from top, Driver=potted and incapsurated. SPD 4 KV internl and 10 KV external with 440 volts compliance for 24 hrs, Lumen efficacy=120 lm/watt, IP 66, IK07, IR protection 1.5 KV, THD<10%, Power factor>0.95, CRI (RA)>70, LED chip should be high power >1 watt, LED driving wattage (1-3 watt), Secondary optics, PC lens pasted and vetted on MCMCB with aluminium pressure die-cast housing including electronic driver 30W LED 6000K, Make : Jaquar Cat Part No LSRTTOS030XC and equivalent in Phillips and OSRAM.
Material and labour in replacement for LED Street light 30W LED, driver and LED compartment should be seperate forwattage above 25 watt, for easy maintenance driver compartment should be opened from top, Driver=potted and incapsurated. SPD 4 KV internl and 10 KV external with 440 volts compliance for 24 hrs, Lumen efficacy=120 lm/watt, IP 66, IK07, IR protection 1.5 KV, THD<10%, Power factor>0.95, CRI (RA)>70, LED chip should be high power >1 watt, LED driving wattage (1-3 watt), Secondary optics, PC lens pasted and vetted on MCMCB with aluminium pressure die-cast housing including electronic driver 30W LED 3000K, Make : Jaquar Cat Part No LSRTTOS030XW and equivalent in Phillips and OSRAM.
Material and labour in replacement for LED Street light 45W LED, driver and LED compartment should be seperate forwattage above 25 watt, for easy maintenance driver compartment should be opened from top, Driver=potted and incapsurated. SPD 4 KV internl and 10 KV external with 440 volts compliance for 24 hrs, Lumen efficacy=120 lm/watt, IP 66, IK07, IR protection 1.5 KV, THD<10%, Power factor>0.95, CRI (RA)>70, LED chip should be high power >1 watt, LED driving wattage (1-3 watt), Secondary optics, PC lens pasted and vetted on MCMCB with aluminium pressure die-cast housing including electronic driver 45W LED 6000K, Make : Jaquar Cat Part No LSRTTOS045XC and equivalent in Phillips and OSRAM.
Material and labour in replacement for LED Street light 45W LED, driver and LED compartment should be seperate forwattage above 25 watt, for easy maintenance driver compartment should be opened from top, Driver=potted and incapsurated. SPD 4 KV internl and 10 KV external with 440 volts compliance for 24 hrs, Lumen efficacy=120 lm/watt, IP 66, IK07, IR protection 1.5 KV, THD<10%, Power factor>0.95, CRI (RA)>70, LED chip should be high power >1 watt, LED driving wattage (1-3 watt), Secondary optics, PC lens pasted and vetted on MCMCB with aluminium pressure die-cast housing including electronic driver 45W LED 3000K, Make : Jaquar Cat Part No LSRTTOS045XW and equivalent in Phillips and OSRAM.
Material and labour in replacement for LED Street light 60W LED, driver and LED compartment should be seperate forwattage above 25 watt, for easy maintenance driver compartment should be opened from top, Driver=potted and incapsurated. SPD 4 KV internl and 10 KV external with 440 volts compliance for 24 hrs, Lumen efficacy=120 lm/watt, IP 66, IK07, IR protection 1.5 KV, THD<10%, Power factor>0.95, CRI (RA)>70, LED chip should be high power >1 watt, LED driving wattage (1-3 watt), Secondary optics, PC lens pasted and vetted on MCMCB with aluminium pressure die-cast housing including electronic driver 60W LED 6000K, Make : Jaquar Cat Part No LSRTTOS060XC and equivalent in Phillips and OSRAM.
Material and labour in replacement for LED Street light 60W LED, driver and LED compartment should be seperate forwattage above 25 watt, for easy maintenance driver compartment should be opened from top, Driver=potted and incapsurated. SPD 4 KV internl and 10 KV external with 440 volts compliance for 24 hrs, Lumen efficacy=120 lm/watt, IP 66, IK07, IR protection 1.5 KV, THD<10%, Power factor>0.95, CRI (RA)>70, LED chip should be high power >1 watt, LED driving wattage (1-3 watt), Secondary optics, PC lens pasted and vetted on MCMCB with aluminium pressure die-cast housing including electronic driver 60W LED 3000K, Make : Jaquar Cat Part No LSRTTOS060XW and equivalent in Phillips and OSRAM.
Material and labour in replacement for LED Street light 72W LED, driver and LED compartment should be seperate forwattage above 25 watt, for easy maintenance driver compartment should be opened from top, Driver=potted and incapsurated. SPD 4 KV internl and 10 KV external with 440 volts compliance for 24 hrs, Lumen efficacy=120 lm/watt, IP 66, IK07, IR protection 1.5 KV, THD<10%, Power factor>0.95, CRI (RA)>70, LED chip should be high power >1 watt, LED driving wattage (1-3 watt), Secondary optics, PC lens pasted and vetted on MCMCB with aluminium pressure die-cast housing including electronic driver 72W LED 6000K, Make : Jaquar Cat Part No LSRTTOS072XC and equivalent in Phillips and OSRAM.
Material and labour in replacement for LED Street light 72W LED, driver and LED compartment should be seperate forwattage above 25 watt, for easy maintenance driver compartment should be opened from top, Driver=potted and incapsurated. SPD 4 KV internl and 10 KV external with 440 volts compliance for 24 hrs, Lumen efficacy=120 lm/watt, IP 66, IK07, IR protection 1.5 KV, THD<10%, Power factor>0.95, CRI (RA)>70, LED chip should be high power >1 watt, LED driving wattage (1-3 watt), Secondary optics, PC lens pasted and vetted on MCMCB with aluminium pressure die-cast housing including electronic driver 72W LED 3000K, Make : Jaquar Cat Part No LSRTTOS072XW and equivalent in Phillips and OSRAM.
Material and labour in replacement for LED Flood light 50W LED, driver and LED compartment should be seperate forwattage above 25 watt, for easy maintenance driver compartment should be opened from top, Driver=potted and incapsurated. SPD 4 KV internl and 10 KV external with 440 volts compliance for 24 hrs, Lumen efficacy=120 lm/watt, IP 66, IK07, IR protection 1.5 KV, THD<10%, Power factor>0.95, CRI (RA)>70, LED chip should be high power >1 watt, LED driving wattage (1-3 watt), Secondary optics, PC lens pasted and vetted on MCMCB with aluminium pressure die-cast housing including electronic driver 50W LED 6000K, Make : Jaquar Cat Part No LFLD04S050XC and equivalent in Phillips and OSRAM.
Material and labour in replacement for LED Flood light 50W LED, driver and LED compartment should be seperate forwattage above 25 watt, for easy maintenance driver compartment should be opened from top, Driver=potted and incapsurated. SPD 4 KV internl and 10 KV external with 440 volts compliance for 24 hrs, Lumen efficacy=120 lm/watt, IP 66, IK07, IR protection 1.5 KV, THD<10%, Power factor>0.95, CRI (RA)>70, LED chip should be high power >1 watt, LED driving wattage (1-3 watt), Secondary optics, PC lens pasted and vetted on MCMCB with aluminium pressure die-cast housing including electronic driver 50W LED 3000K, Make : Jaquar Cat Part No LFLD04S050XW and equivalent in Phillips and OSRAM.
Material and labour in replacement for LED Flood light 70W LED, driver and LED compartment should be seperate forwattage above 25 watt, for easy maintenance driver compartment should be opened from top, Driver=potted and incapsurated. SPD 4 KV internl and 10 KV external with 440 volts compliance for 24 hrs, Lumen efficacy=120 lm/watt, IP 66, IK07, IR protection 1.5 KV, THD<10%, Power factor>0.95, CRI (RA)>70, LED chip should be high power >1 watt, LED driving wattage (1-3 watt), Secondary optics, PC lens pasted and vetted on MCMCB with aluminium pressure die-cast housing including electronic driver 70W LED 6000K, Make : Jaquar Cat Part No LFLDSLM070XC and equivalent in Phillips and OSRAM.
Material and labour in replacement for LED Flood light 70W LED, driver and LED compartment should be seperate forwattage above 25 watt, for easy maintenance driver compartment should be opened from top, Driver=potted and incapsurated. SPD 4 KV internl and 10 KV external with 440 volts compliance for 24 hrs, Lumen efficacy=120 lm/watt, IP 66, IK07, IR protection 1.5 KV, THD<10%, Power factor>0.95, CRI (RA)>70, LED chip should be high power >1 watt, LED driving wattage (1-3 watt), Secondary optics, PC lens pasted and vetted on MCMCB with aluminium pressure die-cast housing including electronic driver 70W LED 3000K, Make : Jaquar Cat Part No LFLDSLM070XW and equivalent in Phillips and OSRAM.
Material and labour in replacement for LED Flood light 100W LED, driver and LED compartment should be seperate forwattage above 25 watt, for easy maintenance driver compartment should be opened from top, Driver=potted and incapsurated. SPD 4 KV internl and 10 KV external with 440 volts compliance for 24 hrs, Lumen efficacy=120 lm/watt, IP 66, IK07, IR protection 1.5 KV, THD<10%, Power factor>0.95, CRI (RA)>70, LED chip should be high power >1 watt, LED driving wattage (1-3 watt), Secondary optics, PC lens pasted and vetted on MCMCB with aluminium pressure die-cast housing including electronic driver 100W LED 6000K, Make : Jaquar Cat Part No LFLDSLM100XC and equivalent in Phillips and OSRAM.
Material and labour in replacement for LED Flood light 100W LED, driver and LED compartment should be seperate forwattage above 25 watt, for easy maintenance driver compartment should be opened from top, Driver=potted and incapsurated. SPD 4 KV internl and 10 KV external with 440 volts compliance for 24 hrs, Lumen efficacy=120 lm/watt, IP 66, IK07, IR protection 1.5 KV, THD<10%, Power factor>0.95, CRI (RA)>70, LED chip should be high power >1 watt, LED driving wattage (1-3 watt), Secondary optics, PC lens pasted and vetted on MCMCB with aluminium pressure die-cast housing including electronic driver 100W LED 3000K, Make : Jaquar Cat Part No LFLDSLM100XW and equivalent in Phillips and OSRAM.
Material and labour in replacement for LIARA Bollard light IP65 rated Inverted Pyramid Tripod type LED bollard with soft 360 degree light distribution die cast aluminium housing powder coated housing with frosted PC diffuser complete inluding fixing using metal sleeve anchor fastners and bolts of suitable size and quantity to be fixed in concrete complete all as specified.Make-CROMPTON Cat Part No LBLSN-10-CDL or equivalent in phillips/OSRAM.
Material and labour in replacement of GATE TOP LIGHT MONACO decorative LED 3000K 10W fixture, aluminium die casting, transperent glass diffuser, black colour IP-43 complete inluding fixing using metal sleeve anchor fastners and bolts of suitable size and quantity to be fixed in concrete all as specified.Make-PHILIPS/CROMPTON GREAVES/JAQUAR
Material and labour in replacement of POLE LIGHT MONACO decorative LED 3000K 20W fixture, aluminium die casting, transperent glass diffuser, black colour IP-43 complete inluding fixing using metal sleeve anchor fastners and bolts of suitable size and quantity to be fixed in PCC block of size 45x45x60cm all as specified. Note : Rate of PCC will be inclusive in the quoted rates and nothing extra will be admission on this account. Make : Jaquar Cat Part No 340.PE8.NGG or equivalent in Osram/Phillips
Material and labour in replacement of MAPLE decorative post top for 360* indirect light with IP 65 protection. Resistant to impact and corrosion,glare-free and better uniformity 40Watts LED 6000K complete inluding fixing using metal sleeve anchor fastners and bolts of suitable size and quantity to be fixed in concrete all as specified. Crompton Cat Part No LPT0-40-CDL-M or equivalent in Jaquar/Phillips
Supply and fix in replacement driver suitable for LED light of capacity 24 to 45 watt as per existing make.
Supply and fix in replacement driver suitable for LED light of capacity 50 to 70 watt as per existing make.
Supply and fix in replacement driver suitable for LED light of capacity 75 to 90 watt as per existing make.
Supply and fix in replacement driver suitable for LED light of capacity 95 to 120 watt as per existing make.
Supply & fixing in replacement of automatic street light switch using Nature Switch for automatic switching of street lights based on LUX level of natural light the sensor (nature switch) along with suitable power contactors and MCBs (Input-output) should be enclosed in pole/wall mountable enclosure made of rust proof, Electric shock proof, termite proof and FR grade SMC junction box (sintex make) conforming to IP 54.the contactor,MCBs and copper circuit wiring (min.16sqmm) should enough to take: three-phase load of 12KW;contactor Rating 80Amps; MCB(spn) Rating 80Amps.MAKE:-Nature switch :Kakatiya energy systems pvt.ltd. hyderabad/bajaj/healer. Contactor:- BCH/L&T/Schneider or equivalent (as per IEC-60947-4-1/IS-13947-4-1), MCBs(Input-output):Hager/schneider/L&T/BCH or equivalent (as per IEC-60898/IS-8828),Circuit wiring : Finolex/polycab/RR Kable or equivalent. Model no SWADEEP-02EC12KW3P.
Supply & fixing in replacement of automatic street light switch using Nature Switch for automatic switching of street lights based on LUX level of natural light the sensor (nature switch) along with suitable power contactors and MCBs (Input-output) should be enclosed in pole/wall mountable enclosure made of rust proof, Electric shock proof, termite proof and FR grade SMC junction box (sintex make) conforming to IP 54.the contactor,MCBs and copper circuit wiring (min.10sqmm) should enough to take: Single-phase load of 5KW;contactor Rating 40Amps; MCB(sp) Rating 40Amps.MAKE:-Nature switch :Kakatiya energy systems pvt.ltd. hyderabad/bajaj/healer. Contactor:- BCH/L&T/Schneider or equivalent (as per IEC-60947-4-1/IS-13947-4-1), MCBs(Input-output):Hager/schneider/L&T/BCH or equivalent (as per IEC-60898/IS-8828),Circuit wiring : Finolex/polycab/RR Kable or equivalent. Model no SWADEEP-02EC5KW1P.
Supply and fixing in replacement of multi core round PVC insulated copper conductor (flexible) industrial cables PVC sheathed cables, 1100 volts conforming to IS : 694 of size 1.5 Sqmm, single core two run from junction box /overhead conductor to street light inside/outside pole complete all as specified.
Supply and Fixing thermoplastics polystyrene/polycarbonate enclosure, shock proof, IP65( weather proof), rust proof, dust proof, water proof, internally embedded gasket with provision for all side cable entry through glands(IP-65) and/or grommets(IP-55). Size of enclosure: ( 130 x 120 x 77 ) mm With suitable connecters for /1Ph loop in loop out and branch out vibration proof connections and fixing on PCC/ steel poles with 25x3mm thick 02 Nos of clamp with nuts and bolts and washers and proper thimbling. Make: HENSEL Cat Part No KF0600B.
Supply, fixing, testing & commissioning of Security light for use on top of the watch cabin with distance piece. High intensity, long range, weather & dust proof security search light with highly polished stainless steel reflector-cum-body, toughened front glass fitted to the cast aluminum front ring kept in position by special head captive volts screwed down to the flange of the lower ring (with incorporated steel inserts at threaded portions) recessed on the flanged of the body, focusing arrangement, G.S. lamp holder with lamp locking arrangement and M.S. Cradle and passivated bolts. The search light fitting would be suitable for installing on the roof of the watch tower cabin with arrangement for both vertical & horizontal operational control from inside the cabin. The search light would be supplied with a distance piece of 1 mtr for enabling the operator to see close to the watch tower also. The search light would be supplied with 230V 400W HPSV Lamp & its control gear in cast aluminum housing. Make-Sigma Type No 21303 or equivalent in philips,Havells. Note :- Drilling of hole on RCC roof, and leak proof fixing arrangement by means of nut, bolts, washers rubber sheet/ etc will be inclusive in this item rate and no extra payment will be made to the contractor on this account
SATISH AND CO
ANANDIKA ELEC AND ENGG WORKS
BMMJ TRADERS AND ENGINEERS
LAL CONSTRUCTIONS
M/S GRD ENGINEERS
SUMEET TRADING CORPORATION
M/S RAJ ENGINEERS
M/S S K Electricals Regd
Jiwan Singh
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .