Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.4 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹32.7 L+₹6.3 L (23.9%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹36.8 L+₹10.4 L (39.3%)Admitted-Finance | L3 | Admitted-Finance | |
| 4 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | SHRI BALAJI ENTERPRISES L3 | Shri Pankaj Roy L1 | Rising Construction Co-Operative Society Ltd L2 |
|---|---|---|---|---|---|---|
| 1.00Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. | ||||||
| 1.10 | All kinds of soil. | 25.24 | cum | 400 ₹10,096 | 200 ₹5,048 Lowest | 250 ₹6,310 |
| 2.00Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level : | ||||||
| 2.10 | 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) | 5.47 | cum | 18,500 ₹1,01,195 | 12,000 ₹65,640 Lowest | 15,600 ₹85,332 |
| 2.20 | 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) | 15.68 | cum | 16,500 ₹2,58,720 | 11,000 ₹1,72,480 Lowest | 14,000 ₹2,19,520 |
| 2.30 | 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 40 mm nominal size derived from natural sources) | 14.64 | cum | 19,500 ₹2,85,480 | 13,000 ₹1,90,320 Lowest | 16,500 ₹2,41,560 |
| 3.00Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement - All work upto plinth level : | ||||||
| 3.10 | 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) | 9.43 | cum | 21,000 ₹1,98,030 | 15,000 ₹1,41,450 Lowest | 18,200 ₹1,71,626 |
| 4.00Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : | ||||||
| 4.10 | 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). | 3.42 | cum | 21,000 ₹71,820 | 18,000 ₹61,560 Lowest | 20,000 ₹68,400 |
Tender Value
₹40.2 L
EMD Value
₹80,358
Closing Date
21 Oct 2025, 3:00 pmClosed
Executive Engineer
Executive Engineer (PRI) South Andaman Division-I No. J/4, Old Councilor Bungalow, Junglighat, Sri Vijaya Puram, South Andaman
Construction of Temporary Fish Market at Govind Nagar Ward No.06 under Gram Panchayat Govind Nagar Swaraj Dweep.
2025_RDPRI_20166_1
EE/PRI/SAD-I/MG/25-26/106
Open Tender
Civil Works - Buildings
Works
365 days
Govind Nagar, Swaraj Dweep
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Executive Engineer, GPPS
₹80,358
25 Oct 2025
9 Oct 2025
22 Oct 2025
10 Oct 2025
21 Oct 2025
10 Oct 2025
Amount
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
All kinds of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level :
1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 40 mm nominal size derived from natural sources)
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement - All work upto plinth level :
1:1.5:3 (1 cement : 1.5 coarse sand (zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :
1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Centering and shuttering including strutting, propping etc. and removal of form for :
Foundations, footings, bases of columns, etc. for mass concrete
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Columns, Pillars, Piers, Abutments, Posts and Struts
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and fixing up to floor five level precast cement concrete hollow block, including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering, shuttering complete.
1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.
40 mm thick with 20 mm nominal size stone aggregate
12 mm cement plaster of mix :
1:4 (1 cement: 4 fine sand)
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Providing CC Surface drain with 1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 40 mm nominal size) finished with cement mortor 1:4 (1 cement :4 sand) including floating coat of neat cement inside the drain and its top and exposed side including earth work in excavation an disposal of surplus earth etc.
23cm x 23cm
Structural steel work in single section, fixed with or without connecting plate,including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
Electric resistance or induction butt welded tubes
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer- in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing in position eaves or facia board with 12 mm thick non asbestos plain sheet of HILUX Board and 30 cm wide including nailing etc complete as per the direction of Engineer - in - charge.
Finishing walls with Acrylic Smooth exterior paint of required shade :
New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.
Fixed to openings /wooden frames with rawl plugs screws etc.
12 mm cement plaster finished with a floating coat of neat cement of mix :
1:4 (1 cement: 4 fine sand)
Wiring for Light Point /Fan Point/exhaust fan point/call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
Group -C
Wiring for Light / Power Plug with 2 x 4 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 no 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following size of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 x 1.5 sq.mm + 1x 1.5 sq.mm earth wire
1 x 6 sq.mm + 2 x 6 sq.mm earth wire
Supplying and fixing following piano type switch/ socket on the existing switch box / cover including connections etc.as required.
5/6 amps switch
3 pin 5/6 amp socket outlet
Supplying and Fixing two module stepped type electronic gan regulator on the existing on the existing modular plates switsh box including connection but excluding modeular plate etc.as required.
Supplying and Fixing PVC box of size 180 mm x 100 mm x 60 mm deep (nominal size) on surface or inrecess with suitable size of phenolic laminated sheet cover in front i/c providing and fixing 6 pin 15/16 amps socket outletand 15/16 amps piano type switch connection painting etc. as required.
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 240V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
12 Way , Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts,"C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc.as required.
Single pole
Supplying and fixing following rating, Double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc.as required.
Earthing with G.I. earth pipe 4.5 metre long,40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required.
Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I Pipe from earth electrode including connection with copper thimble excavation and re- filling as required.
Providing and fixing 25 mm X 5 mm copper wire on surface or in recess for connections etc. as required.
Supplying and installation of ceiling fan (1200 mm sweep),i/c wiring the down rods of standard length (upto 30cm) with 1.5sq.mm FRLS PVC insulated, copper conductor, single core cable etc. as required .Make: Crompton or equivalent to ISI standard.
Supplying and Installation of Wall fan (400 mm sweep), including making good the damage, connection, testing commissioning etc. as required. Make Orient, Crompton or equivalent to ISI standard.
Supplying and installation of 20 w LED tube light fitting/ fluorescent tube fitting/ compact fluorescent fitting of all type complete with all accessories and tube etc.directly on ceiling/ wall,i/c connection with 1.5sq mm FRLS PVC insulated copper conductor single core cable and earthing etc. as required .Make: Havells CAT No. LHEXBXPNIN1W020 or equivalent to ISI standard.
Supplying and Installation of 30W LED Street Light fittings of all sizes and shapes, including fabrication of metallic pole for road way light fitting upto 1.0 meters made out of 32 mm dia. G.I. pipe etc. including fixing on the wall, painting connections etc. as required. complete with all accessories including connection etc. as required. Make:- Bajaj or Equivalent to ISI standard.
Providing and fixing wooden Board of size 10" X 12" for fixing of energy meter etc. as required.
Rising Construction Co-Operative Society Ltd (BID ID -59685)
SHRI BALAJI ENTERPRISES (BID ID -59731)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .