Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.9 LAccepted-AOC SCHOOL LINE NEAR MINNIEBAY JUNCTION SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L1 | Accepted-AOC Accept | |
| 2 | L2₹50.0 L+₹2.1 L (4.47%)Rejected-Finance 290 NEW PLOT JAWAHAR NAGAR JAMMU JAMMU JAMMU KASHMIR 180005 | JAMMU | JAMMU AND KASHMIR | 180005 | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹50.6 L+₹2.7 L (5.72%)Rejected-Finance DAIRY FARM JUNCTION VIJAY BAUGH ROAD SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744103 | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹51.1 L+₹3.3 L (6.88%)Rejected-Finance | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹51.7 L+₹3.9 L (8.12%)Rejected-Finance DOCTORS COLONY ROAD NAYAGAON SHADIPUR POST PORT BLAIR 744 106 A N ISLANDS | PORT BLAIR | SOUTH ANDAMANS | A N ISLANDS | 744106 | L5 | Rejected-Finance Not being L1 |
| Sl No | Description | Qty | Unit | M/s Pooja Enterprises L4 | A. R. ELECTRICALS L1 | Sree Tirumala Enterprises L3 | Kathir Marketing Services L7 | T.THIYAGARAJAN L8 | PTech Engineers L5 | Blue chip consultancy Service L6 | Allied Trading Company L2 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in soft / loose soil not exceeding 1.5 mtr wide and n exc 1.5 mtr depth and getting out incl forming of bottom for laying cable all as specified and directed by Engr-in-Charge. | 431.5 | Cum | 500 ₹2,15,750 | 390 ₹1,68,285 Lowest | 415 ₹1,79,072.5 | 450 ₹1,94,175 | 450 ₹1,94,175 | 428 ₹1,84,682 | 425 ₹1,83,387.5 | 400 ₹1,72,600 |
| 2.00 | Returning filling using excavated soil including spreading leveling, watering and well ramming in layers n exc 25 cms all as specified and directed by Engr-in-Charge. | 388.35 | Cum | 220 ₹85,437 | 180 ₹69,903 Lowest | 190 ₹73,786.5 | 220 ₹85,437 | 250 ₹97,087.5 | 198 ₹76,893.3 | 199 ₹77,281.65 | 189 ₹73,398.15 |
| 3.00 | Removal of surplus excavated material n.exc 50 mtrs and depositing where directed at a level n.exc 1.5 mtrs above the starting point all as specified and directed by Engr-in-Charge . | 43.15 | Cum | 300 ₹12,945 | 260 ₹11,219 | 275 ₹11,866.25 | 250 ₹10,787.5 Lowest | 250 ₹10,787.5 Lowest | 296 ₹12,772.4 | 288 ₹12,427.2 | 270 ₹11,650.5 |
| 4.00 | Supply and fix in replacement on load change over switch 415 V, 4 pole, 160 A as per existing make and model suitable equivalent make as per list of make at PS complete all as specified and directed. | 2 | Each | 22,500 ₹45,000 | 21,000 ₹42,000 Lowest | 21,500 ₹43,000 | 24,000 ₹48,000 | 25,000 ₹50,000 | 22,000 ₹44,000 | 21,200 ₹42,400 | 21,900 ₹43,800 |
| 5.00 | Supply & fix in replacement on load change over switch with SS enclosure 415 V, 4 pole, 125 A as per existing make and model or suitable equivalent make as per list of make at PS complete all as specified and directed. | 5 | Each | 17,000 ₹85,000 | 16,500 ₹82,500 Lowest | 16,800 ₹84,000 | 18,560 ₹92,800 | 22,000 ₹1,10,000 | 17,500 ₹87,500 | 19,600 ₹98,000 | 16,510 ₹82,550 |
| 6.00 | Supply & fix in replacement MCCB, 415 volts, 4 pole adjustable thermal setting type 25 KA, 63A as per existing make and model suitable or equivalent make as per list of make at PS complete all as specified and directed. | 6 | Each | 8,500 ₹51,000 | 8,000 ₹48,000 Lowest | 8,250 ₹49,500 | 9,000 ₹54,000 | 9,000 ₹54,000 | 8,500 ₹51,000 | 8,450 ₹50,700 | 8,005 ₹48,030 |
| 7.00 | Supply & fix in replacement MCCB, 415 volts, 3 pole adjustable thermal setting type 25 KA, 63A as per existing make and model suitable or equivalent make as per list of make at PS complete all as specified and directed. | 4 | Each | 7,500 ₹30,000 | 7,200 ₹28,800 | 7,100 ₹28,400 Lowest | 8,100 ₹32,400 | 7,500 ₹30,000 | 7,500 ₹30,000 | 7,460 ₹29,840 | 7,205 ₹28,820 |
| 8.00 | Supply & fix in replacement MCCB, 415 volts, 4 pole adjustable thermal setting type 25 KA, 100A as per existing make and model or suitable equivalent make as per list of make at PS complete all as specified and directed. | 8 | Each | 8,600 ₹68,800 | 8,500 ₹68,000 | 8,400 ₹67,200 Lowest | 8,900 ₹71,200 | 8,500 ₹68,000 | 8,500 ₹68,000 | 8,659 ₹69,272 | 8,540 ₹68,320 |
| 9.00 | Supply & fix in replacement MCCB, 415 volts, 3 pole adjustable thermal setting type 25 KA, 100A as per existing make and model or suitable equivalent make as per list of make at PS complete all as specified and directed. | 4 | Each | 7,550 ₹30,200 | 7,500 ₹30,000 Lowest | 7,750 ₹31,000 | 8,800 ₹35,200 | 9,000 ₹36,000 | 8,000 ₹32,000 | 7,680 ₹30,720 | 7,502 ₹30,008 |
| 10.00 | Supply and fix in replacement MCCB, 415 volts, 4 pole 25 KA, 125A as per existing make and model suitable or equivalent make as per list of make at PS complete all as specified and directed. | 2 | Each | 10,000 ₹20,000 | 9,800 ₹19,600 Lowest | 9,950 ₹19,900 | 10,800 ₹21,600 | 11,000 ₹22,000 | 10,000 ₹20,000 | 9,999 ₹19,998 | 9,805 ₹19,610 |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
17 Jul 2025, 6:00 pmClosed
GE, Minniebay, Sri Vijaya Puram
GE, Minniebay, Junglighat (PO), Sri Vijaya Puram -744103
8616/E8-REPAIR / REPLACEMENT OF STREET LIGHT, HIGH MAST LIGHTS, LT PANELS, CABLES, TIMER PANELS, LT CABLES, MCCBS, LT DISTRIBUTION SYSTEM, LT PANELS, MCCBS, LT UG CABLE, CHANGEOVER SWITCHES AND CONNECTED WORKS AT VAYU VIHAR BROOKSHABAD, NTS TEYLERABA
2025_MES_716806_1
8616/E8
Open Tender
Civil Works
Item Rate
270 days
GE, Minniebay, Sri Vijaya Puram
Please refer Tender documents.
13 documents required · 13 mandatory
₹500
Yes
GE, Minniebay
₹92,000
Yes
23 Aug 2025
26 Jun 2025
19 Jul 2025
26 Jun 2025
17 Jul 2025
10 Jul 2025
Amount
Excavation in soft / loose soil not exceeding 1.5 mtr wide and n exc 1.5 mtr depth and getting out incl forming of bottom for laying cable all as specified and directed by Engr-in-Charge.
Returning filling using excavated soil including spreading leveling, watering and well ramming in layers n exc 25 cms all as specified and directed by Engr-in-Charge.
Removal of surplus excavated material n.exc 50 mtrs and depositing where directed at a level n.exc 1.5 mtrs above the starting point all as specified and directed by Engr-in-Charge .
Supply and fix in replacement on load change over switch 415 V, 4 pole, 160 A as per existing make and model suitable equivalent make as per list of make at PS complete all as specified and directed.
Supply & fix in replacement on load change over switch with SS enclosure 415 V, 4 pole, 125 A as per existing make and model or suitable equivalent make as per list of make at PS complete all as specified and directed.
Supply & fix in replacement MCCB, 415 volts, 4 pole adjustable thermal setting type 25 KA, 63A as per existing make and model suitable or equivalent make as per list of make at PS complete all as specified and directed.
Supply & fix in replacement MCCB, 415 volts, 3 pole adjustable thermal setting type 25 KA, 63A as per existing make and model suitable or equivalent make as per list of make at PS complete all as specified and directed.
Supply & fix in replacement MCCB, 415 volts, 4 pole adjustable thermal setting type 25 KA, 100A as per existing make and model or suitable equivalent make as per list of make at PS complete all as specified and directed.
Supply & fix in replacement MCCB, 415 volts, 3 pole adjustable thermal setting type 25 KA, 100A as per existing make and model or suitable equivalent make as per list of make at PS complete all as specified and directed.
Supply and fix in replacement MCCB, 415 volts, 4 pole 25 KA, 125A as per existing make and model suitable or equivalent make as per list of make at PS complete all as specified and directed.
Supply & fix in replacement MCCB, 415 volts, 4 pole adjustable thermal setting type 35 KA, 125A as per existing make and model or suitable equivalent make as per list of make at PS complete all as specified and directed.
Supply & fix in replacement MCCB, 415 volts, 3 pole adjustable thermal setting type 35 KA, 125A as per existing make and model or suitable equivalent make as per list of make at PS complete all as specified and directed.
Supply & Fix in replacement MCCB, 415 volts, 4 pole adjustable thermal setting type 35 KA, 250A as per existing make and model or suitable equivalent make as per list of make at PS complete all as specified and directed.
Supply & Fix in replacement MCB SP 5 to 32 Amps, 440V, 10KA 'C' Curve as per existing make and model or suitable equivalent make as per list of make at PS complete all as specified and directed.
Supply & Fix in replacement MCB SP 40 to 63 Amps, 440V, 10KA 'C' Curve as per existing make and model or suitable equivalent make as per list of make at PS complete all as specified and directed.
M&L for fixing in replacement straight through jointing kits heat shrinkable type LT UG XLPE cable heavy duty armoured sheathed and making the disturbed surface after relaying the cable and making joints suitalbe for aluminium conductor of 16 to 25 Sqmm 3.5 core complete all as specified and directed. Note : Taking up cable, excavation, returning filling and removal of surplus soil upto 1 cum meter shall be included in the qouted rate. More than 1 cum shall be measured and paid separately under relevant items of this schedule.
16 to 25 Sqmm 3.5 Core
35 to 70 Sqmm 3.5 Core
95 to 150 Sqmm 3.5 Core
185 to 240 Sqmm 3.5 Core
Supplying and laying in replacement of GI tubing medium grade for cable protection in trenches/duct/fixing to pole/wall or in such similar position of following size all as specified and directed:-
80 mm dia
50 mm dia
Taking up old unserviceable LT UG cables from trench/poles/wall etc of following size all as specified and directed:-
25 Sqmm 3.5 core
35 Sqmm 3.5 core
50 Sqmm 3.5 core
95 Sqmm 3.5 core
185 Sqmm 3.5 core
300 Sqmm 3.5 core
Supply and laying LT UG cable XLPE insulated armoured and PVC sheathed 1100 volts grade with aluminium conductor stranded of following sizes all as specified and directed by Engineer-in-charge:- Note : Earth works excavation, returning filling, removal of surplus soil shall be measured and paid under relevant of this items.
25 Sqmm 3.5 core
35 Sqmm 3.5 core
50 Sqmm 3.5 core
95 Sqmm 3.5 core
185 Sqmm 3.5 core
300 Sqmm 3.5 core
M&L for re-laying and re ruiting of existing LT UG cable XLPE insulated armoured and PVC sheathed 1100 volts grade with aluminium conductor stranded of following sizes and connections testing in new or old position after complete all as specified and directed by Engr-in-Charge of the following as under:- Note : Earth works excavation, returning filling, removal of surplus soil, shall be measured and paid separately under relevant of this Items.
50 Sqmm 3.5 core
95 Sqmm 3.5 core
240 Sqmm 3.5 core
300 Sqmm 3.5 core
Supply & laying in replacement DWC (Double Wall Corrugated) HDPE pipe ISI marked of outer dia of 50 mm and inner dia 38 mm polethylene including couplers, bends, cap etc., with smooth internal and profiled external surface for non pressure under ground cable complete all as secified and directed by Engr-in-Charge.
Supply & laying in replacement DWC (Double Wall Corrugated) HDPE pipe ISI marked of outer dia of 63 mm and inner dia 50 mm polethylene including couplers, bends, cap etc., with smooth internal and profiled external surface for non pressure under ground cable complete all as secified and directed by Engr-in-Charge.
Supply & laying in replacement DWC (Double Wall Corrugated) HDPE pipe ISI marked of outer dia of 77 mm and inner dia 63 mm polethylene including couplers, bends, cap etc., with smooth internal and profiled external surface for non pressure under ground cable complete all as secified and directed by Engr-in-Charge.
Material and labour for earthing complete with Glavnised iron plate 60x60 cm x 6 mm thick electrode buried directly in ground (earth pit no less than 2.25 Mtrs deep below ground level) with top edge of the plate not less than 1.5 Mtrs below normal ground level connected to glavnasied earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers all as shown in electrical plate no. 5 connected to earth test point and provn of GI pipe 20 mm dia medium grade for watering, GI pipe 40 mm dia light grade for earth strip protection all as specified and including excavation, earth work provn of earth pit, pit cover, CI funnel, wire mesh etc complete and testing on completion. all as secified and directed by Engr-in-Charge.
Supply & Fix in replacement aluminium cables lugs for cables of size upto 16 Sqmm including necessary crimping with crimping tool complete all as specified and directed
Supply & Fix in replacement aluminium cables lugs for cables of size upto 25 Sqmm including necessary crimping with crimping tool complete all as specified and directed
Supply & Fix in replacement aluminium cables lugs for cables of size upto 35 Sqmm including necessary crimping with crimping tool complete all as specified and directed
Supply & Fix in replacement aluminium cables lugs for cables of size upto 50 Sqmm including necessary crimping with crimping tool complete all as specified and directed
Supply & Fix in replacement aluminium cables lugs for cables of size upto 70 Sqmm including necessary crimping with crimping tool complete all as specified and directed
M & L for repair of LT Panel board outdoor type repair/replace damaged door hinges set of three nos front and back side and legs 40x40x6mm MS angle and necessary cutting, welding & drilling hole etc.works required at site complete all as specified and directed by Engineer-in-charge.
M&L for providing cement concrete Type D2 1:4:8 using 40mm graded stone aggregate in foundation filling and mass concrete for foundation for pole etc all as specified and directed.
M&L for providing cement concrete Type C1 1:3:6 using 20mm graded stone aggregate in foundation filling and mass concrete for coping of pole etc all as specified and directed.
S&F pole cap made out of MS including one coats of aluminium paint over two coat of red oxide primer suitable for 8.5 / 9.0/ 11.0 mar long tubular pole including threaded hole 3 Nose and suitable size of nut and bolts complete all as specified and directed.
M & L for painting steel tubular poles 9/11 Mtr long including cross arms etc. with one coat of aluminium paint including preparation of surfaces and writing feeder name and pole number on the pole complete all as specified and directed by Engr-in-Charge
M & L for painting RCC poles 9/11 Mtr long including cross arms etc. with one coat of white paint including preparation of surfaces and writing feeder name and pole number on the pole complete all as specified and directed by Engr-in-Charge
M & L for painting to feeder pillar box / LT panel & duct cover etc, including angle iron frame with two coats of grey or colour as approved by GE / Engr in -Charge as per site suitability synthetic enamel paint including door welding with hinges complete as specified and directed
Supply & Fix in replacement LED driver 25 to 40 Watt for street light/flood light/high bay light all as specified and directed.
Supply & Fix in replacement LED driver 45 to 75 Watt for street light/flood light/high bay light all as specified and directed.
Supply & Fix in replacement LED driver 100 to 150 Watt for street light/flood light/high bay light all as specified and directed.
Supply & Fix in replacement Surge protection device (SPDs) for street light/flood light fixing in before place driver in street light surger protection rating up to 2 KV all as specified and directed.
S&F in replacement GI bracket for fixing street/ security light fitting made out of GI pipe medium grade 25 mm dia 1.50 Mtr long bent to required angle/ shape complete with MS flat iron clamp of size 25x5 mm, nut, bolt, washer of suitable size as per site requirement etc and fixed in pole/wall including two coats of aluminium paint over a coat of red oxide primer to MS clamps, nut, bolts etc complete all as specified and directed.
M&L for RCC pole reshiefting for street light of any type/size all as specified and directed by Engr-in-Charge Note : Excavation/earth work etc shall be measured and paid for separately under relevant item of this Schedule.
S&F in replacement of FRP boxes with 4 connectors heavy duty, and clamps made out of GI nuts, bolts , busbar chamber existing size including provn of Aluminium Busbar SPN 30 Amps capacity fixed on porcelain insulator, 01 No MCB SP 6 Amps Capacity complete all as specified and directed.
S & F Astronomical timer switch for security light, to be fixed on existing LT panel, range 6W to 12W confirming to IS/IEC 60947-1 provided with protection degree IP 54, Extrended with brand coil, with FRLS internal wiring, inbuild short circuit protection,Class H insulation of complete all as specified and as directed by Engineer-in-charge. (Make - Havells)
S&F in replacement of Street light fitting warm white LED type, 72 Watts 240 Volts high luminous , energy efficiency not less than 100 lm/Watt , including SPD fitting before placing the street light and accessories complete mounted on light grade GI pipe bracket 1.0 mtr long bent to shape, mounted on wall,connection complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of Street light fitting warm white LED type, 90 Watts 240 Volts high luminous , energy efficiency not less than 100 lm / Watt , including SPD fitting before placing the street light and accessories complete mounted on light grade GI pipe bracket 1.0 mtr long bent to shape, mounted on wall,connection complete all as specified and directed.
S&F in replacement of bright Flood light fitting warm white LED type, 150 Watts 240 Volts lumen efficiency not less than 100 lm/Watt , PDC housing with IP 65 flood light opties , efficient housing output LED sleek and robust design for better aesthetics , highly efficient reliable and sturdy, mounted on wall,connection complete all as specified and directed by Egineer-in-Charge.
S&F in replacement energy efficient post top light fitting on wall/gate 360 degree indirect light with IP 65 protection high quality integrated LEDs assuring soothing warm white light all night long LED 40 W black case aluminuim, including all necessary wiring , clamps, nut and bolts mounting accessories etc all as specified and directed.
S&F in replacement energy efficient warm white bollard light with IP-65 fitting on ground, wall etc high quality integrated LEDs assuring soothing warm white light all night long LED 10 W black case aluminuim including all necessary wiring , clamps, nut and bolts mounting accessories etc all as specified and as directed by Engr-in-Charge. . Make- Philips
S&F in replacement of high bay light 150 W 220V 50 Hz innovatirely designed hear sink for superior thermal management high efficiency round highbay in PDC housing, luminaire upto 130Lm/W ,IP-66 complete all as specified and directed
S & F in replacement of outdoor type water proof LED Tricolour (Orange+ White+Green) in single strip for decorative illumination 18 mtr long IP 65 , waterproof,dustproof, weather resistance (UV,water temprature) including power adopter ,drivers. The materials used for fixing on poles fastners, clips,clamp, Adhesive double sided tape etc all as specified and as directed by Engineer in Charge
Attending day to day external security lights,Perimeter lights,Solar lights,Bollard lights,flood lights,High Mast lights,dispersal lights, Sankalp smark LED decorative lights complaints (street lights/High Mast light fitted on poles / buildgs at height upto 20M from ground level), Repair / replacement of unserviceable accessories like LED drivers, PCB,SPD etc nuts, bolts, clamps etc incl sundays and holidays incl all required tools, ladders and other incidential operation requirements for execution of maint work all complete as specifed and directed. Note : (i) All the fittings of LED /solar street lights/High Mast light/flood light etc will be cleaned. The rate for which shall be deemed to be included in the qouted rate. (ii) Cost of spares and accessories will be measured and paid separately under relevent item of this schedule (iii) Cost for taking down and re-fixing new spare parts shall be included in the unit rate qouted. (iv) Necessary T&P shall be included in the qouted rate for repair / replacement of unserviceable LED lights ,High mast light, Driver, brackets, SPD and copper conductor upto 20 mtr height street lights fitted on pole / wall. (v) Street light complaints to be carried out as per complaint basis incl sunday and holiday.
M&L for disconnecting LT supply and taking out defective LT draw out EDO type ACB 440 V 800Amp / 630Amp and servicing cleaning the fixed and moving all parts, removing dust particles by using high speed blower applying grease/jelly to moving mechanism and moving parts, tightening nut bolts of all the components of ACB complete and putting on full load testing all as specified and as directed by Engr-in-Charge.
S&F in replacement of Draw out terminals for Air circuit breakers EDO type suitable for 800/630 Amp as per existing make and model complete all as directed at site by Engr-in-Charge.
Earthing complete with GI earth electrode of size 60cmx60cmx6mm buried directly in ground vertically at a depth not less than 2.25 meter below normal ground level with top edge of earth plate at a depth not less than 1.5 meter below normal ground surrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers cleaned connected to and including GI earth strip 32 x 6mm size up to 7.5 mtr by means of bolts, nuts, check nuts and washers made of galvanised iron and protected light grade 50mm dia 5 mtr long GI pipe connected to main control board and GI pipe light grade 20mm bore for watering and including funnel wire mesh, RCC pit cover 50mm thick with 10mm dia reinforcement 100mm c/c and PCC chamber pit with pcc 1:2:4 Type C2 (including excavation and earth work disposal of surplus soil to a distance not exceeding 50 meter) and testing after completion all as specified and shown on plate No 3 of SSR Part -I 2009.
M & L for repair of LT Panel board outdoor type repair/replace damaged door hinges set of three nos front and back side and legs 40x40x6mm MS angle and necessary cutting, welding drilling hole,pcc repairs,cables slevees with colour code,repairs old us wiring etc works required at site complete all as specified and directed by Engr-in-Charge .
S&F in replacement of Digital Voltmeter (0-500) including connections and testing for proper functioning complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Digital Ammeter including connections and testing for proper functioning complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Indicating Lamp R, Y, B (LED) Type including connections and testing for proper functioning complete all as specified and directed by Engineer-in-charge.
S&F in replacement of CTs of required rating including connections and testing for proper functioning complete all as specified and directed by Engr-in-Charge.
Material & Labour for spray painting to feeder pillar box / LT panel & duct cover etc, including angle iron frame with two coats of synthetic enamel paint grey or colour as approved by GE / Engr in -Charge as per site suitability synthetic enamel paint including door welding with hinges complete as specified and directed by Engr-in-Charge .
M&L for PCC 1:2:4 type B-2 using 20mm grade stone aggregate as in coping of poles including necessary form work and fair finishing to exposed surface without using extra cement complete all as specified.
Attending breakdown for LT Panels/ LT Cables/MCCB/Changeover Switch to check and locate / detect fault related to breakdown complete all as directed by Engineer-in-charge. Note:- (a) Spares will be measured and paid separately under relavant items. (b) The break down complaint should be attended within 2 hours with the intimation of Engr-in-charge or concern JE E/M by telephonically / verbally. (c) Not attended of complaint within tow hours will lead to recovery from subsequent payment in the following manner :- (i) Not attending within 2 to 4 Hours - Rs. 1000.00 (ii) Not attending within 4 to 6 Hours- Rs. 1500.00 plus the expenditure incurred for rectification of the same by any other means.
Allied Trading Company (BID ID -3355605)
Sree Tirumala Enterprises (BID ID -3360091)
M/s Pooja Enterprises (BID ID -3356813)
PTech Engineers (BID ID -3361370)
Blue chip consultancy Service (BID ID -3360518)
Kathir Marketing Services (BID ID -3360291)
T.THIYAGARAJAN (BID ID -3360715)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .