Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.4 CrAccepted-AOC MAIN ROAD PRAGATI VIHAR RISHIKESH DEHRADUN 249201 | DEHRADUN | UTTARAKHAND | 249201 | ₹5.4 Cr | L1 | Accepted-AOC L1 bidder |
| 2 | L2₹6.0 Cr+₹62.6 L (11.6%)Rejected-AOC 23 1 MANDIR LINE MW SINGTAM NAGAR PANCHAYAT SINGTAM EAST SIKKIM 737134 | EAST DISTRICT | SIKKIM | 737134 | ₹6.0 Cr+₹62.6 L (11.6%) | L2 | Rejected-AOC L2 bidder |
| 3 | L3₹6.9 Cr+₹1.5 Cr (28.0%)Rejected-AOC | ₹6.9 Cr+₹1.5 Cr (28.0%) | L3 | Rejected-AOC L3 bidder |
| 4 | L4₹7.1 Cr+₹1.7 Cr (31.3%)Rejected-AOC | ₹7.1 Cr+₹1.7 Cr (31.3%) | L4 | Rejected-AOC L4 bidder |
| 5 | L5₹7.1 Cr+₹1.7 Cr (31.9%)Rejected-AOC 419 NEW SONAL SERVICE IND ESTATE LINK ROAD MALAD W MUMBAI 400064 | MUMBAI SUBURBAN | MAHARASHTRA | 400064 | ₹7.1 Cr+₹1.7 Cr (31.9%) | L5 | Rejected-AOC L5 bidder |
Tender Value
₹7.2 Cr
EMD Value
₹14.5 L
Closing Date
8 May 2023, 5:00 pmClosed
General Manager (Civil Contracts-IV), NHPC Limited
NHPC Ltd., NHPC Office Complex, 2nd Floor, Jyoti Sadan, Sector-33, Faridabad -121003, Haryana, India
Package C3 Civil Works of Power House Complex including Valve House, Surge Shaft and Tail Pool for Renovation and Modernization of Loktak Power Station
2023_NHPC_747925_1
NH/CCW/CCIV/CO-253/PR10222/334
Open Tender
Civil Works
Works
638 days
Loktak Power Station Manipur
As per Tender Document
7 documents required · 7 mandatory
₹1,500
NHPC Limited
₹14.5 L
Yes
9 Jan 2025
3 Apr 2023
11 May 2023
3 Apr 2023
8 May 2023
17 Apr 2023
Amount
Power House, Valve House, Tailpool & switchyard
Power House Complex (including Surge shaft, Valve House & Tail Pool)
Surface Excavation
Common Excavation
Embankment construction and backfill
Backfill
Drilling, Grouting and Pressure relief holes
Provision of 45mm dia pressure relief holes/drainage holes
Drilling of 45mm dia holes
Supply & Instalation of PVC pipe 36 mm dia.
Concrete
Reinforced Cement Concrete M25/A20 for Fire fighting Tank and Equipment foundation - for new foundation & repair of old foundations in Valve House, Power House, Switchyard, Transformer area and Penstock saddles including formwork, etc.
Second Stage Concrete M30/A20 including formwork,etc.
Plastering with Cement Mortar(1:4) 25mm thick- for Cable trech & drains repair
Cement variation in concrete
Reinforced/Plain cement Concrete Cutouts and Epoxy Grout
Making cut-out in RCC/PCC member with Diamond Core Drilling/ Core Cutting System- Core diameter-152mm: Providing and making cut-outs in RCC/PCC members (Walls, Beams, Slabs etc) with diamond core drilling/core cutting system by performing stitch coring along the periphery of designated cut-out. The cores shall be drilled adjacent to each other on periphery of cut-out so as to ensure straight and neat cut lines. The edges/arches formed between the cores shall be chipped off with electrical hammer making it clean. The item includes cost of all required tools and tackles, consumables, diamond inserts etc. complete. Mode of measurement : Number of cores cut along periphery shall be measured for billing, cost of core shall be paid in 'mm' of depth of core cut.
Applying of two components epoxy grout for filling the cracks/ voids (less than 6mm) including providing necessary equipments for injection grouting, making grooves, drilling holes & fixing the injection nozzles, sealing the grooves with epoxy mortar and setting up the equipments for grouting, etc. complete in all respects as per technical specification
a) Surface preparation & making grooves
b) Providing & fixing nozzles into the grooves
c) Sealing grooves with epoxy mortar excluding the cost of supply of epoxy binder and aggregate/filler
d) Injecting of two components epoxy grout excluding the cost of supply of epoxy grout
Supply of two-components epoxy resin bonding system (resin & hardener) conforming to ASTM C881 Type-IV, Class-C as per technical specification for use as epoxy grout and epoxy binder.
Supply of aggregate/ filler for use with epoxy binder for making epoxy mortar as per technical specification
Plain Concrete (M25A40) including formwork, etc.
(Refer DSR VOL-II, Item Code No. 22.23) Providing and applyying INTEGRAL CRYSTALLINE SLURRY of Hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, Water Tanks, Roof Slabs, Podiums, Reservoir, Sewage & Water Treatment plant, Tunnels/ Subway and Bridge Deck, etc., prepared by mixing in the ratio of 5 : 2 (5 parts INTEGRAL CRYSTALLINE SLURRY : 2 parts WATER) for VERTICAL SURFACES and 3 : 1 (3 parts INTEGRAL CRYSTALLINE SLURRY : 1 part WATER) for HORIZONTAL SURFACES and applying the same from NEGATIVE (INTERNAL) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e. by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 BAR HYDROSTATIC PRESSURE on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.5mm. The work shall be carried out all complete as per specification and direction of the Engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.
For Vertical surface two coats @0.70 kg per sqm. per coat
For Horizontal surface one coat @1.10 kg per sqm.
Reinforcing Steel
Deformed reinforcement bars Grade Fe 500
Concrete repair using cementious mortar as per EN1504-3-R4
Power House Complex (including Surge shaft, Valve House & Tail Pool)
Dewatering of construction sites including supply, installation and removal of pumping equipment from site.
Surface Excavation
Removal of temporary embankment fill
Embankment construction and backfill
Concrete
Repair & Protection in exposed condition with high performance cementitious repair mortar [Based on EN 1504-3-R4]
Surface preparation of old concrete by cleaning methods like compressed air/ high pressure water blast/ sand blast, chipping, wire brush or other means for laying of repair mortar as per technical specification including all stages and scaffolding etc. (Complete finished item with all leads and lifts).
Providing and applying high performance cementitious mortar on exposed/ eroded concrete surface as per technical specification. Generally the thickness of the layer shall be kept 12.5mm. (Complete finished item with all leads and lifts). (Repair of Draft Tube & PRV Piers, Gate grooves, Counterfort in Tail Pool, Valve House and slab & beams in power house building, etc.)
Plain Concrete (M25A20) for repair works including formwork, etc.
Slope Protection
Laying of geomembrane including cost of supply, storage and transportation upto site as per specification.
Sand bags for diversion and repair works
Laying of geotextile including cost of supply, storage and transportation upto site as per specification.
Ithai Barrage
Concrete
Repair & Protection in exposed condition with high performance cementitious repair mortar [Based on EN 1504-3-R4]
Surface preparation of old concrete by cleaning methods like compressed air/ high pressure water blast/ sand blast, chipping, wire brush or other means for laying of repair mortar as per technical specification including all stages and scaffolding etc. (Complete finished item with all leads and lifts).
Providing and applying high performance cementitious mortar on exposed/ eroded concrete surface as per technical specification. Generally the thickness of the layer shall be kept 12.5mm. (Complete finished item with all leads and lifts). (Repair of Piers, Abutments/Sidewalls, Bridge including depressions,etc.)
Power channel, Emergency Gate & Zero shaft gate
Restoration of Tiddim Bridge
Concrete
Repair & Protection in exposed condition with high performance cementitious repair mortar [Based on EN 1504-3-R4]
Surface preparation of old concrete by cleaning methods like compressed air/ high pressure water blast/ sand blast, chipping, wire brush or other means for laying of repair mortar as per technical specification including all stages and scaffolding etc. (Complete finished item with all leads and lifts).
Providing and applying high performance cementitious mortar on exposed/ eroded concrete surface as per technical specification. Generally the thickness of the layer shall be kept 12.5mm. (Complete finished item with all leads and lifts). (Repair of Bridge including piers, abutments and slab etc.)
Strengthening of Zero Gate Shaft structure
Concrete
Repair & Protection in exposed condition with high performance cementitious repair mortar [Based on EN 1504-3-R4]
Surface preparation of old concrete by cleaning methods like compressed air/ high pressure water blast/ sand blast, chipping, wire brush or other means for laying of repair mortar as per technical specification including all stages and scaffolding etc. (Complete finished item with all leads and lifts).
Providing and applying high performance cementitious mortar on exposed/ eroded concrete surface as per technical specification. Generally the thickness of the layer shall be kept 12.5mm. (Complete finished item with all leads and lifts). (Repair mortar in Piers, walls, Gate grooves, etc.)
S.N.MARKETING
ALPHA PACIFIC SYSTEMS PVT. LTD.
STARCON INFRA PROJECT INDIA PRIVATE LIMITED
Dynasoure Concrete Treatement Pvt.Ltd.
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .