Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹14.0 CrAccepted-AOC | ₹14.0 Cr Quoted ₹14.2 Cr | 1 | Accepted-AOC L1 |
| 2 | 2₹18.0 CrRejected-Finance | ₹18.0 Cr | 2 | Rejected-Finance L2 |
| 3 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
Refer Docs
EMD Value
₹45 L
Closing Date
14 Mar 2022, 2:00 pmClosed
Chief Executive Officer
Karnal Smart City Limited
Construction of Hockey Stadium at Kailash under Smart City Mission
2022_HRY_207625_1
KSCL/CEO/2021-22/789
Open Tender
Civil Works
270 days
Karnal
Please refer Tender documents.
2 documents required · 2 mandatory
₹50,000
₹45 L
CEO Office Karnal
8 Jun 2022
10 Feb 2022
14 Mar 2022
10 Feb 2022
14 Mar 2022
10 Feb 2022
17 Feb 2022
Amount
Civil Works Supply and fixing of Hockey Goal Post Aluminium of FIH approved drawings and design including all fitting and net
Supplying of FIH approved global category synthetic hockey turf from FIH preferred producer/supplier and laid by FIH certified field builder and jointing and fixing the same 15 mm thick rubberized under layer as per the FIH requirements and the pasting of synthetic grass as per the global category FIH competition including all marking on the surface as per FIH rules and standard etc. Complete as per instruction of engineer-in -charge.
RUIDP 2017 19.4.3Providing, lowering, laying, aligning, fixing in position at and jointing at all level/ depths ISI marked HDPE pipes of PE-100 grade & PN-6 for potable water as per IS 4984 (amended upto date) in trenches complete with all accessories like Bend, Tee, Reducer, Stub end, End cap etc including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer. 110 mm dia
Chattisghar PHE SOR 2020 ,9.9Providing and Supplying Blue MDPE pipes conforming to ISO 4427:1996 manufactured from virgin resin PE 80 Food grade compounded Raw Material having Blue Colour only with quality assurance certificate from quality agencies like WRC/CIPET (India)/ DVGM /KIWA /SPGN etc. for usage in Drinking Water System The cost shall include testing of all materials, Inspection charges, transportation up to site, transit insurance, loading, unloading, stacking etc. complete.
Electrical Parking Lighting cum Road Lighting Panel & Practice Field : Fabrication, supplying and installation of outdoor type cubical panel board of suitable size made out of GI sheet 2 mm thick (14 SWG) and powder coated thereafter, duly compartmentalised having door locking arrangement for protection from rain, dust, duly fixed on GI angle iron frame work of size 50 mm x 50 mm x 6 mm (NS) and having following accessories mounted inside the panel including connection, inter connection with aluminium thimbles, earthing with two nos. earth studs, duly powder coated complete etc. as required, Civil Foundation cost for the panel shall be inclusive. Cable gland plates shall be provided on bottom. 2 Nos. earthing terminals shall be provided. Panels shall be suitable for 415V, 3-phase, 4-wire, 50Hz supply system, lifting hooks shall also be provided in case of large panels with surge arrestor. Incomer :100A FP MCCB - 1NOS Outgoing : 40A TPN MCCB - 5 NOS ; Indication lamps (RYB) with control MCB - 03 Sets with Timer and Contactor Danger notice plate Make : As listed in UHBVNL
Mainfield Lighting : Fabrication, supplying and installation of outdoor type cubical panel board of suitable size made out of GI sheet 2 mm thick (14 SWG) and powder coated thereafter, duly compartmentalised having door locking arrangement for protection from rain, dust, duly fixed on GI angle iron frame work of size 50 mm x 50 mm x 6 mm (NS) and having following accessories mounted inside the panel including connection, inter connection with aluminium thimbles, earthing with two nos. earth studs, duly powder coated complete etc. as required, Civil Foundation cost for the panel shall be inclusive. Cable gland plates shall be provided on bottom. 2 Nos. earthing terminals shall be provided. Panels shall be suitable for 415V, 3-phase, 4-wire, 50Hz supply system, lifting hooks shall also be provided in case of large panels with surge arrestor. Incomer :200A FP MCCB - 1NOS Outgoing : 63A TPN MCCB - 5 NOS ; Indication lamps (RYB) with control MCB - 03 Sets with Timer and Contactor Danger notice plate Make : As listed in UHBVNL
Supply of following size XLPE insulated, 1100V grade armoured alluminium cable as per specification confirming to IS:7098 (Part - I) 4C x 10sqmm Al Ar cable
Supply of following size XLPE insulated, 1100V grade armoured alluminium cable as per specification confirming to IS:7098 (Part - I)4C x 6sqmm Al Ar cable
SITC of 40W LED Batten having Extruded aluminium housing fitted with Engg. Plastic end caps. With Opal diffuser.LED should be populated on FR4 PCB in which LED’s should be mounted & connection should be in series parallel.LED Used shall be SMD type and fixture should have minimum efficacy at System level (Not Chip Level)>=110lumens/watt, Minimum system Lumens 4400 lm ±10%. Life of fixture 50000hrs@L70% Lumen maintenance, CCT up to 6500K ±500K, CRI>=80, PF>=0.9,THD<10%, and Operating Temperature Range-10 deg C to +50deg C, IP20. Built in Surge Protection of 4KV and an operating Voltage Range of 140 to 300V AC,50Hz.The driver should be constant current driver.The fixture should comply with the parameters as per IS10322 and IEC60598, EMC / EMI compliance. Bajaj Cat. Ref.BCLAB SP 44L LED CW PC SD or Equivalent.
SITC of recessed mounted LED 600x600mm fitting made of CRCA) sheet steel housing comprising of LED’s connected in series parallel,Opal diffuser fixed in separate white powder coated ,Opal diffuser frame is held in with housing by screws for easy maintenance. Fixture should have minimum efficacy at System level (Not Chip Level) >=100lumens/watt, ,Minimum system Lumens 3600 lm ±10%Life of fixture 50000hrs@L70 Lumen maintenance, CCT up to 5700K±300K, CRI minimum 80, PF ≥0.95, THD <10% and an operating Voltage Range of 140 to 277V AC. Minimum Internal Surge Protection 2.5 kV. The fixture should comply with the other parameters as per IS10322 and specifications. Bajaj Cat. Ref BZRSLL 36W LED WH i
Supply of LED recessed Downlighter with a nominal system lumen output of 1200 lumens ±10% and a minimum system efficacy of 100 lm/W. The luminaire should have a color temperature of 5700K and CRI>80. The luminaire shall meet IP20 rating with THD<10% and PF > 0.95. Built-in Surge protection of 2 kV,Maintenance of lumen output 50000 hrs.The luminaire housing should made of pressure die cast aluminium with a high efficiency diffuser.Bajaj Cat. Ref BZSLOS nxt 12L LED WH SD
Supply of 40W LED industrial Weatherproof Batten having Extruded aluminium housing fitted with end caps. Luminaire should be Completely prewired with accessories up to terminal block and fixture should have minimum efficacy at System level (Not Chip Level)>=120lumens/watt, Minimum system Lumens 4800 lm ±10%. Life of fixture 50000hrs@L70% Lumen maintenance, CCT up to 6500K ±500K, CRI>=80, PF>=0.9,THD<10%, and Operating Temperature Range-10 deg C to +50deg C, IP65,IK07. Built in Surge Protection of 4KV and an operating Voltage Range of 140 to 300V AC,50Hz.The driver should be constant current driver. The fixture should comply with the parameters as per IS10322 and IEC60598, EMC / EMI compliance. Bajaj Cat. Ref.BI PC 40W XE TYPE or Equivalent.
SITC of 300mm swepp Light duty exhaust fan with metal blades etc complete
SITC of energy efficient fan, 1200 mm sweep, aluminium body, consuming 28 W, BEE 5 star rated, ceiling fan with Brush Less Direct Current(BLDC)motor, class of insulation: B, 3 no's blades, 30 cm long down rod, 2 no's canopies, suitable for 230V, 50 HZ, single phase AC supply, earthing etc., including all standard accessories etc., complete.
SITC of 25A Metal clad sockets for 2TR Air conditioner
2TR Split AC
Stadium Mast Lighting System D/S/I/T/C of 34Mtr Stadium Mast with fixed head frame suitable for mounting upto 18 nos. LED Flood Light Fixtures Complete with all accessories.
D/S/I/T/C of foundation bolts manufactured from special steel along with nuts, washers, anchor plate and common template.
D/S/I/T/C of Manrider System for Stadium Mast with fixed head frameComplete with all accessories. ( Common for All Four mast)
Foundation casting for 34Mtr High mast with all tools and tackles, shuttering and masonary work as per specification.
S/I/T/C of Bajaj make 1000W LED Flood Light Fixture.
S/I/T/C of single dome LED AOL.
S/I/T/Commissioning of outdoor type, metal enclosed, double door, pedestal mounted, Vermin Proof, fixed type Distribution Box made outof 2mm thick CRCA Sheet having IP55 protection with canopy, suitable for use on 415V, 3Phase, 4wire, 50 HZ and complete with powder coated with color shade as per relevant IS, of suitable size for accomodating the following component, Including providing 3mm thk detachable glandplate for incoming and outgoing cables entry, fixed to structure through clamp, complete with painting, interconnections, earthing, etc. as per tender technical specification (HMLDB):
Supply of Aluminium conductor, XLPE insulated, PVC outer sheathed, armoured cable of 1.1KV grade as per IS 7098 (1) of following sizes : 4Cx6 sq.mm (From HMLDB to CAJB)
Supply & laying of Copper conductor, PVC insulated, flexible cable as per IS 694 of following sizes: 3Cx2.5 sq.mm
Provision of GI pipe earthing for High mast with 2.5 M long 40 mm dia GI Pipe including connection to High mast earth terminal with 25 x 3 mm GI flats with all materials and labour. (2nos per mast required)
Supply & fixing of 50X6mm GI Strip from earth electrode including connection with GI nut, bolt, spring washer, excation, refilling etc as required.
Hockey Ground Practice Light D/S/I/T/C of 17Mtr Stadium Mast with fixed head frame suitable for mounting upto 8 nos. LED Flood Light Fixtures Complete with all accessories.Suitable Cage ladder provided for Maintenance purpose.
D/S/I/T/C of foundation bolts manufactured from special steel along with nuts, washers, anchor plate and common template.
Foundation casting for 17Mtr High mast with all tools and tackles, shuttering and masonary work as per specification.
S/I/T/C of Bajaj make 1000W LED Flood Light Fixture.
S/I/T/C of single dome LED AOL.
S/I/T/Commissioning of outdoor type, metal enclosed, double door, pedestal mounted, Vermin Proof, fixed type Distribution Box made outof 2mm thick CRCA Sheet having IP55 protection with canopy, suitable for use on 415V, 3Phase, 4wire, 50 HZ and complete with powder coated with color shade as per relevant IS, of suitable size for accomodating the following component, Including providing 3mm thk detachable glandplate for incoming and outgoing cables entry, fixed to structure through clamp, complete with painting, interconnections, earthing, etc. as per tender technical specification (HMLDB):
Supply of Aluminium conductor, XLPE insulated, PVC outer sheathed, armoured cable of 1.1KV grade as per IS 7098 (1) of following sizes : 4Cx6 sq.mm (From HMLDB to CAJB)
Supply & laying of Copper conductor, PVC insulated, flexible cable as per IS 694 of following sizes: 3Cx2.5 sq.mm
Provision of GI pipe earthing for High mast with 2.5 M long 40 mm dia GI Pipe including connection to High mast earth terminal with 25 x 3 mm GI flats with all materials and labour. (2nos per mast required)
Supply & fixing of 50X6mm GI Strip from earth electrode including connection with GI nut, bolt, spring washer, excation, refilling etc as required.
Road & Parking Area Supply testing and commissioning of Smart Feeder Panels Controllers (3 phase) Indication lamps & digital metering Incoming : 63A TPN MCCB, 415 V, 50 Hz. : 1 Nos Outgoings : a) 25 A, TPN MCB , 50 Hz : 4 Nos.
Supply of 120W Streetlight having Epoxy powder coated pressure die-cast aluminium housing, Weatherproof gaskets should be provided for LEDs and control gear compartments. Luminaire should be suitable for Side entry mounting for 55 to 60mm OD pipe bracket..The LED driver acces should be from top for easy maintenance.LEDs should be provided with non-yellowing modular secondary lens optics.LED Used shall be SMD type and fixture should have minimum efficacy at System level (Not Chip Level)>=120lumens/watt, Minimum system Lumens 14400 lm ±10%. Life of fixture 50000hrs@L70% Lumen maintenance, CCT up to 5665K ±355K, CRI>=70, PF>=0.9,THD<10%, and Operating Temperature Range-5 deg C to +50deg C, IP66. Built in Surge Protection of 4KV & external surge protection of 10kVand an operating Voltage Range of 140 to 270V AC,50Hz.Luminaire Weight should not exceed 3.7kg.The driver used is specially designed to have built-in surge voltage, open/short circuit protections. The fixture should comply with the parameters as per IS10322 and IEC60598, EMC / EMI compliance.
Gallery Lighting Supply of 55W highbay luminaire having Pressure die-cast aluminum housing and LED driver compartment with LED fixed on die-cast aluminum heat sink for proper thermal management.Secondary lens should be provided on each LED. Luminaire should be prewired with accessories up to terminal block.Eye-bolt should be provided for suspension mounting.LED Used shall be SMD type and fixture should have minimum efficacy at System level (Not Chip Level)>=110lumens/watt, Minimum system Lumens 6050 lm ±10%. Life of fixture 50000hrs@L70% Lumen maintenance, CCT up to 5700K ±355K, CRI>=80, PF>=0.90,THD<10%, Impact resistence IK rating of IK06 and Operating Temperature Range-5 deg C to +45deg C, IP65. Built in Surge Protection of 4KV and an operating Voltage Range of 140 to 270V AC,50Hz.Luminaire Weight should not exceed 3kg.LED Driver should be of Constant current driver to have built-in surge, open & short circuit protection..The fixture should comply with the parameters as per IS10322 and IEC60598, EMC / EMI compliance. Bajaj Cat. Ref.TENTO nxt B 60L WH MB/NB SD or Equivalent.
Cables Supply of following size XLPE insulated, 1100V grade armoured alluminium cable as per specification confirming to IS:7098 (Part - I) 4C x 16sqmm Al Ar cable
Supply of following size XLPE insulated, 1100V grade armoured alluminium cable as per specification confirming to IS:7098 (Part - I) 3.5C x 400sqmm Al Ar cable
Supply of following size XLPE insulated, 1100V grade armoured alluminium cable as per specification confirming to IS:7098 (Part - I) 3.5C x 70sqmm Al Ar cable
Supply of following size XLPE insulated, 1100V grade armoured alluminium cable as per specification confirming to IS:7098 (Part - I) 3.5C x 50sqmm Al Ar cable
Supply of following size XLPE insulated, 1100V grade armoured alluminium cable as per specification confirming to IS:7098 (Part - I) 3.5C x 25sqmm Al Ar cable
Supply of following size XLPE insulated, 1100V grade armoured alluminium cable as per specification confirming to IS:7098 (Part - I) 4C x 16 sqmm Al Ar cable
Supply of following size Copper flexible cable: 3Cx2.5Sqmm
O&M O&M of Hockey stadium where Removal of dust / dried leaves/ Debris and upkeep of the playing arena with proper operation of sprinkler system etc on daily Baises,Removal of any organic growth on and around the pitch Daily baises,Removal of inorganic material from on and around the pitch and the surrounding area; including glass,bottles, food wrappers, and general rubbish items on daily baises,Removal of contamination such as bird and animal droppings ensuring the area is neutralized on daily baises,Pressure Machine Vacuum Cleaning on half yearly,Chemical Washing for algae/fungal issues yearly,Inspect and test all sprinkler systems ensuring performance is correct quarterly baises,Any repair, renovation work, painting of sports equipment, Fencing etc as per Actuals on quarterly baises,Inspect all drainage infrastructure areas around the pitch clearing as necessary on half yearly baises & Thorough major inspection and machine grooming by senior grounds persons and/or professional surface grooming company on yearly baises. 2 GROUND MEN &1 ELECTRICIAN should avilable at Site any time required or as directed by engineer in charge.
Bidder Name
Amount
GROWEVER INFRA PRIVATE LIMITED(GSTN-NA)
AM INFRASTRCTURE PROJECTS PVT. LTD.(GSTN-NA)
AM INFRASTRCTURE PROJECTS PVT. LTD.
GROWEVER INFRA PRIVATE LIMITED
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid