Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹22.5 LAccepted-AOC 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | DELHI CANTT | NEW DELHI | DELHI | 110010 | 1 | Accepted-AOC Accepted being L1 | |
| 2 | 2₹24.2 L+₹13,921.95 (0.58%)Rejected-AOC WZ 1000 B NANGAL RAYA PANKHA ROAD NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | 2 | Rejected-AOC Rejected being not L1 | |
| 3 | 3₹26.6 L+₹2.5 L (10.6%)Rejected-AOC | 3 | Rejected-AOC Rejected being not L1 | |
| 4 | 4₹28.0 L+₹4.0 L (16.4%)Rejected-AOC NO 9 BYRAVESHWARA INDUSTRIAL ESTATE ANDRAHALLI MAIN ROAD NEAR PEENYA 2ND STAGE BENGALURU 560 091 | BENGALURU URBAN | KARNATAKA | 560091 | 4 | Rejected-AOC Rejected being not L1 | |
| 5 | 5₹29.9 L+₹5.8 L (24.2%)Rejected-AOC | 5 | Rejected-AOC Rejected being not L1 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
13 Jul 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE UTILITY ELEC SUPPLY
GE UTILITY ELEC SUPPLY DELHI CANTT
REPAIR AND MAINTENANCE OF LT HT ELECTRICAL BREAKDOWN INCL FAULT DETECTION LOCALIZATION AND RECTIFICATION IN UNDERGROUND NETWORK AT CARRIAPA VIHAR 105 TA 1 WEC EETSU, DAS BARAR SQUARE RR COLONY PERIRA ENCLAVE EETSU POLO GROUND TODAPUR KHANDHA
2024_MES_661519_1
GE ELEC/D-16/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE UTILITY ELEC SUPPLY
ALL AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE UTILITY ELEC SUPPLY
₹90,000
Yes
21 Sept 2024
22 Jun 2024
15 Jul 2024
22 Jun 2024
13 Jul 2024
6 Jul 2024
Amount
Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft/loose soil for laying/taking up/ taking down of cables and getting out and levelling of bottom suface to required level complete all as specified and directed by the Engg- in- Charge.
Returning filling in, Including spreading, levelling, Watering and well ramming soil in layers not exceeding 25 cm thick complete all as specified and directed by the Engg- in- Charge.
Removing excavated material (ie soil) from site to a distance n. exc 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point all as complete all as specified and directed by the Engg- in- Charge.
M&L for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables etc complete all as specified and directed by the Engg- in-Charge. Note : Measurement shall be taken after punning down.
S&F sub class B bricks having minimum compressive strength 75 Kg/ Sqcm laid in trenches for cable protection etc complete all as specified and directed by the Engg- in- Charge.
All as per srl item No 05 above but using old bricks complete all as specified and directed by the Engg- in- Charge.
Supplying and laying un-reinforced precast concrete cable cover, class HV, type 1, flat size 300mmx 180mm x 40mm complete all as specified and directed by the Engg- in- Charge.
All as per srl item No 07 here-in-before but using old un-reinforced precast concrete cable cover complete all as specified and directed by the Engg- in- Charge.
Supply, laying, jointing, testing and commissioning in replacment LT underground cables 1100 volts grade, PVC insulated XLPE and PVC sheathed, heavy duty armoured, with multistranded aluminium conductors, IS-1554 marked, laid in trenches, poles etec complete all as specified and directed by the Engg- in- Charge of the following sizes:- Note:- Excavation, earth work ,cable protection , sand fillings , cable joint shall be measured and paid separately.
16 Sqmm 4 core
25 Sqmm 4 core
35 Sq mm 3.5 core.
50 Sq mm 3.5 core.
70 Sqmm 3.5 core
95 Sqmm 3.5 core
120 Sqmm 3.5 core
185 Sqmm 3.5 core
240 Sqmm 3.5 core
300 Sqmm 3.5 core
400 Sqmm 3.5 core
Supplying, laying, jointing, testing and connecting in replacement XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, 11 KV grade, IS 7098 marked, suitable for HT 11 KV(E) system, laid in trenches or fixed to pole etc, complete all as specified and directed by the Engg- in- Charge of following sizes Note :- Excavation, earth work ,cable protection , sand fillings , cable joint shall be measured and paid separately.
95 sqmm 3 core.
120 sqmm 3 core.
185 sqmm 3 core
240 sqmm 3 core
300 sqmm 3 core
Testing the cables with high voltage DC testing machine and locating the fault in the cables by fault locating machine to pin point exact position of fault, disconnecting faulty 11 KV HT cables of different sizes from both ends, removal of Fault, Re-connections and testing of cables after removal of fault complete all as specified and directed by the Engg- in- Charge. Note: (a) 11 KV HT cable & joints shall be measured and paid for seperately under respective items of schedule. (b) Retrieved old serviceable cable cover/bricks will be laid in trenches for cable protection. If extra PCC cover/bricks and sand required at site shall be measured and paid separately under respective items of BOQs. (c) Excavation and earth work will be measured and paid for seperately under respective items of schedule.
All as per item Ser No 11.00 above but 1100 Volt LT cables complete all as specified and directed by the Engg- in- Charge.
Taking out faulty underground 1100 Volt LT cable of different sizes by excavation and removing bricks of any size and relaying in the same trenches or re routing after rectification of fault or replacing faulty portion of cable with new cable and removing of surplus soil and using new bricks as required complete all as specified and directed by the Engg- in- Charge. Note: (a) 1100 Volt LT cable & joints shall be measured and paid for seperately under respective items of schedule. (b) Retrieved old serviceable bricks will be laid in trenches for cable protection. If extra bricks and sand required at site shall be measured and paid separately under respective items of BOQs. (c) Excavation and earth work will be measured and paid for seperately under respective items of schedule.
All as per item Ser No 13.00 above but 11000 Volt HT cables complete all as specified and directed by the Engg- in- Charge.
M&L for disconnecting faulty /burnt end or portion of cable by removing the cable from loop including necessary excavation & earth work , suitable size of thimble LT tap, relaying and reconnecting the cable by removing faulty/burnt portion of cable and preparing fresh terminals for 25 Sqmm 3.5/4 core to 240 Sqmm 3.5 core of LT cable to LT Panel/pole/main switch complete all as specified and directed by the Engg- in- Charge.
Supply, fixing, jointing and testing of LT Straight through joint heat shrinkable type with jointing kit suitable for cable PVC/XLPE insulated armoured heavy duty aluminium conductor 1100 Volts grade complete all as specified and directed by the Engg- in- Charge for the following sizes :-
16-50 Sqmm x 3.5 core/ 4 core
70-150 Sqmm x 3.5 core
185 -300 Sqmm x 3.5 core
Supply, fixing, jointing & testing of Cable jointing kit for 11 KV (Earthed) grade cable for Indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable complete all as specified and directed by the Engg- in- Charge of following size:-
95 Sqmm,3 core.
120 Sqmm to 185 Sqmm, 3 core.
240 Sqmm to 300 Sqmm 3 core
Supply, fixing, jointing & testing Cable jointing kit for 11 KV (Earthed) grade cable for Outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable complete all as specified and directed by the Engg- in- Charge of following size :-
95 Sqmm 3 core.
120 Sqmm to 185 Sqmm, 3 core.
240 Sqmm to 300 Sqmm, 3 core.
Supply, fixing, jointing and testing of Cable jointing kit for 11 KV (Earthed) grade cable for Straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable complete all as specified and directed by the Engg- in- Charge of following size:-
95 Sqmm 3 core.
120 Sqmm to 185 Sqmm, 3 core.
240 Sqmm to 300 Sqmm 3 core
Boring of hole under road/pavement/hard standing or any other situation by mannual means and including GI pipe 100 mm bore (medium grade) and making good both ends complete all as specified and directed by the Engg- in- Charge.
Supply and lay GI pipe light grade in replacement as cable protection laid on trench/floor, fixed on pole/wall etc of following sizes complete all as specified and directed by the Engg- in- Charge of following sizes:-
100 mm dia
80 mm dia
50 mm dia
40 mm dia
M&L in replacement for Retro Reflective installation sign board of size 12 Feet x 4 Feet using 3 mm ACP sheet duly riveted/fixed on fabricated stainless steel 304 grade finished hollow section of size 25mmx50mm with supporting SS strips in base at a height of 7.5 meter above ground level on stainless steel 304 grade pipe of size 80mm embedded 90 CM in PCC 1:2:4 type B 1 block of size 45cmx45cmx90cm including necessary excavation and earth work. The board shall be machine printed and the front of the ACP shall be overall sheathed with blue colour base adhesive tape. The writing matter shall be in English language on both side using reflective adhesive Painter tapes complete all as specified and directed by the Engg- in- Charge. The size and letters and matter to be printed shall be finalized by Engr-in-Charge.
M&L for spreading of stone aggregate of nominal size not more than 25mm under 4/6 pole HT structure /surrounding area of outdoor RMU manually without damaging any equipments, cable or parts , spreading & levelling of finished gravel uniformly in layers n. exc. 15 cm thick watered and rammed to true surface complete all as specified and directed by the Engg- in- Charge.
S&F in replacement of 60 Watt LED street light fittings with IP66 protection, aluminium pressure die-cast housing, toughned glass in the front incl making connections complete all as specified and directed by the Engg-in-Charge.
S&F in replacement KIOSK box wheather proof including made out of one piece mounted SMC base and door pole mounted hinged door size 333x233x120mm out side and 300x200x105mm inside dimensions comprising of aluminium bus bar 4 strips for 3 phase and neutral 63 Amps including embossing/painting of danger notice of size not less than 10cm x 7.5cm with letters, figures and conventional skull and bones in signal red colour on front face of KIOSK box body complete all as specified and directed.Incluiding MS clamp of size 25x3 mm with suitable size nut,bolts & washer complete all as specified and directed by the Engg-in-Charge.
S&F in replacement bracket for street light fitting complete with 2.2 mtr long 50mm dia GI pipe medium grade and including necessary mild steel clamp, nuts, bolts and washers and painting on steel surfaces with two coats of aluminium paint complete all as specified and directed by the Engg-in-Charge.
M&L for re-painting of LT Steel tubular poles of any sizes with apply of 2 coats of aluminium paint including rubbing with wire brush/sand paper & writing pole Nos in appropriate size of letters including making yellow and black strips upto height of 1.5 mtr above from ground level complete all as specified and directed by the Engg-in-Charge.
Supplying and fixing in replacement LED flood light fitting with IP66 protection, aluminium pressure die-cast housing, toughned glass in the front incl making connections complete all as specified and directed by Engr-in-charge of the following wattage :-
Supply and laying in replacement in sub station 3.3 KV to 11 KV insulating mat of size 5mtr x 1 mtr x 2.5 mm thick specification as per IS-15652 2006 complete all as specified and directed by the Engg-in-Charge.
Earthing in replacement complete with galvanized steel earth plate electrode of size 60cmx60cmx6 mm thick, buried directly in ground (earth pit not less than 2.10 m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level, connected to galvanized iron strip 32x6mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel as shown in electrical plate No 3 of SSR Part I, connected to earth test point and the equipment on the other nuts and washers of galvanised ironside complete all as specified, including testing and commissioning complete all as directed. Note :- (a) The unit rates quoted against this item shall be deemed to include the cost of excavation and earth work in any type of soil, common salt & charcoal dust in alternate layers, PCC 1:3:6 as in pit, precast RCC 1:2:4 type B-1 with necessary reinforcement as in cover & frame for pit, funnel, watering pipe 20 mm bore GI pipe light grade, protection pipe 40 mm bore GI pipe medium grade etc. (b) The quoted rates shall also deemed to include the cost of earth test point and earth strip/GI lead wire and protection pipe upto 7.5 meter beyond the earth plates electrode.
Supply, installing, testing and commissioning in replacement of factory made and tested HT Panel board, size: 1200 mmx1200mmx900mm, cubical compartmentalized, out door type double door, suitable for 11000 Volts, 3 phase, 50 HZ AC supply system having bus bar chamber with insulated aluminium bus bars of size ,50 mm x 10 mm, 3 Nos installed on SMC insulators suitable for 11000 Volts. The panel shall be dust and vermin proof. IP-65 class protection and shall be made of 3.15 mm CRCA MS sheet, and 50x 50 x 6mm thick MS angle iron frame work, powder coated front and rear opening type, with apron for cable entry closing locking . The fixing of double doors shall be on MS hinges with anti-theft provision (the door can’t be removed from enclosure without cutting enclosure). including excavation, earth work and platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45 cm above the nearest road level complete all as specified and directed by Engr-in-charge.
M&L for construction of brick masonry platform for Transformer of size 3.0m x 3.0m and total height 1.40 m (0.40 M below ground level and 1.0M above ground level including excavation and earth work ) with brick construction in wall and steps, using TMT bars 10mm thick to the distance of 0.15 mtr on the platform from both sides, PCC 1:3:6 type C-2 in foundation, brick work in CM 1:4, 15mm thick rendering in CM 1:4 on fair face of walls and steps, 100mm thick PCC 1:2:4 type B-2 (using 40mm graded crushed stone aggregate) in floor and paving, 40mm thick PCC on steps, and MS channels of size 3 mtr (02 Nos) beneath the TMT bar on the platform for better support with painting to foundation and steps complete all as specified and directed by Engr-in-charge.
Disconnecting electrically (and mechanically, ) outdoor transformers upto 500 KVA capacity, lowering down from 4/6 pole structure carefully and Re-installation of transformer on plinth , connecting electrically and mechanically, testing and commissioning complete all as specified and directed.( rate is deemed to be inclusive of , T&P hydra and man power ) complete all as specified and directed.
S&F mild steel chequered plates Fe410-W (Gde-E-250) quality on cable duct pit sizes as required on site 6mm to 10 MM thick including taking out of old unserviceable RCC duct cover complete all as specified and directed by the Engg-in-Charge
Note : contractor should procure and provide 50 % of the material as listed above within 15 days of the placing of work order and shall be verified by the Engr-in-charge
mayur enterprises (BID ID -3057765)
Rajindera Enterprises (BID ID -3057491)
Vijay Electricals (BID ID -3059639)
ALLIED CONSTRUCTION (BID ID -3059620)
MV Engineers And Contractors (BID ID -3059536)
Ridhi engineers and builders (BID ID -3059932)
Commercial Traders (BID ID -3059881)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .