Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹52.92Admitted-Finance 24 12A 12A LAXMI NARAYAN AGGARWAL MARG SETHI CLINIC SHAKTI NAGAR NEW DELHI NORTH DELHI DELHI 110007 | NORTH DELHI | DELHI | 110007 | ₹52.92 | L1 | Admitted-Finance |
| 2 | L2₹60.54+₹7.62 (14.4%)Admitted-Finance 211A SECTOR 16 HSIIDC INDUSTRIAL AREA STERIMED MEDICAL DEVICES PVT LTD BAHADURGARH BAHADURGARH JHAJJAR HARYANA 124507 | JHAJJAR | HARYANA | 124507 | ₹60.54+₹7.62 (14.4%) | L2 | Admitted-Finance |
| 3 | L3₹70.56+₹17.64 (33.3%)Admitted-Finance | ₹70.56+₹17.64 (33.3%) | L3 | Admitted-Finance |
| 4 | Rejected-Technical NO 27A NEAR STATE BANK OF INDIA HOSUR ROAD ELECTRONICS CITY PHASE I BANGALORE KARNATAKA 560100 | BENGALURU URBAN | KARNATAKA | 560100 | - | - | Rejected-Technical Non responsive |
| 5 | Rejected-Technical II FLOOR MODULE 29 BLOCK II SIDCO ELECTRONIC COMPLEX THIRU VI KA INDUSTRIAL ESTATE GUINDY CHENNAI TAMIL NADU 600032 | CHENNAI | TAMIL NADU | 600032 | - | - | Rejected-Technical Non responsive |
| Sl No | Description | Qty | Unit | STERIMED MEDICAL DEVICES PVT. LTD L2 | VITROMED HEALTHCARE L3 | Ribbel International Ltd L1 |
|---|---|---|---|---|---|---|
| 1.00 | Sterile Catheter, Single Use, for Urinary Drainage (Foley Balloon Catheter), 2 Way, Size16 FG
• Made of Silicone elastomer bonded with Latex
• Should have hard plastic valve
• Smooth distal end with smooth eyes for atraumatic intubation
• Symmetrical foley balloon
• Balloon capacity 30 ± 1 ml
• Should conform to IS 11497
• Color coding marking to identify size
• Length, wall thickness and balloon capacity should be mentioned as per IS 11497.
• Specification for B,C,D,E,F,G should be mentioned as per IS11497 for particular size | 14,13,110 | Each piece | 16.39 ₹18.36 | 19 ₹21.28 | 15.75 ₹17.64 Lowest |
| 2.00 | Sterile Catheter, Single Use, for Urinary Drainage (Foley Balloon Catheter), 2 Way, Size18 FG
• Made of Silicone elastomer bonded with Latex
• Should have hard plastic valve
• Smooth distal end with smooth eyes for atraumatic intubation
• Symmetrical foley balloon
• Balloon capacity 30 ± 1 ml
• Should conform to IS 11497
• Color coding marking to identify size
• Length, wall thickness and balloon capacity should be mentioned as per IS 11497.
• Specification for B,C,D,E,F,G should be mentioned as per IS11497 for particular size | 5,01,016 | Each piece | 16.39 ₹18.36 | 20 ₹22.4 | 15.75 ₹17.64 Lowest |
| 3.00 | Double J Stent, Sterile, Both Ends Open - size 4F, length 16 cm
• Radio opaque
• Should be of inert material, non- irritant to tissue | 3,222 | Each piece | - | - | - |
| 4.00 | Double J Stent, Sterile, Both Ends Open, size 5F, length 20 cm
• Radio opaque
• Should be of inert material, non- irritant to tissue | 3,222 | Each piece | - | - | - |
| 5.00 | Double J Stent, Sterile, One End Closed - size 4F, length 16 cm
• Radio opaque
• Should be of inert material, non- irritant to tissue | 2,982 | Each piece | - | - | - |
| 6.00 | Double J Stent, Sterile, One End Closed, size 5F, length 20 cm
• Radio opaque
• Should be of inert material, non- irritant to tissue | 3,042 | Each piece | - | - | - |
| 7.00 | K Wire, length 375 mm; 1mm
Length of wire should be mentioned with specification.
As per IS 8261 | 10,346 | Each piece | - | - | - |
| 8.00 | K Wire, length 375 mm;1.6mm
• Length of wire should be mentioned with specification.
• As per IS 8261 | 14,152 | Each piece | - | - | - |
| 9.00 | K Wire, length 375 mm; size 1.8mm
• Length of wire should be mentioned with specification.
As per IS 8261 | 16,176 | Each piece | - | - | - |
| 10.00 | Bone cement with antibiotics,fast and slow setting | 15,142 | 40 GM PACK | - | - | - |
Tender Value
₹5 Cr
EMD Value
₹5 L
Closing Date
6 Sept 2021, 6:00 pmClosed
MD, RMSCL
RMSCL, Swasthya Bhawan, Tilak Marg, Jaipur 302005
-BID FOR RATE CONTRACT CUM SUPPLY AND EMPANELMENT OF SURGICALS (DRUG ITEMS) (Rate Contract for the period ending on 30.09.2023)
2021_RMSCL_235749_1
F.02(104)RMSCLProc. Surgical(Drug) NIB-15 2021 432
Open Tender
Supply of Materials/Hiring of Goods
Item Wise
60 days
All DDW of Rajasthan
Please refer Tender documents.
4 documents required · 4 mandatory
₹2,000
MD, RMSCL
₹5 L
Yes
Meeting Hall, RMSCL
2 Nov 2021
4 Aug 2021
7 Sept 2021
20 Aug 2021
6 Sept 2021
25 Aug 2021
10 Aug 2021
Sterile Catheter, Single Use, for Urinary Drainage (Foley Balloon Catheter), 2 Way, Size16 FG • Made of Silicone elastomer bonded with Latex • Should have hard plastic valve • Smooth distal end with smooth eyes for atraumatic intubation • Symmetrical foley balloon • Balloon capacity 30 ± 1 ml • Should conform to IS 11497 • Color coding marking to identify size • Length, wall thickness and balloon capacity should be mentioned as per IS 11497. • Specification for B,C,D,E,F,G should be mentioned as per IS11497 for particular size
Sterile Catheter, Single Use, for Urinary Drainage (Foley Balloon Catheter), 2 Way, Size18 FG • Made of Silicone elastomer bonded with Latex • Should have hard plastic valve • Smooth distal end with smooth eyes for atraumatic intubation • Symmetrical foley balloon • Balloon capacity 30 ± 1 ml • Should conform to IS 11497 • Color coding marking to identify size • Length, wall thickness and balloon capacity should be mentioned as per IS 11497. • Specification for B,C,D,E,F,G should be mentioned as per IS11497 for particular size
Double J Stent, Sterile, Both Ends Open - size 4F, length 16 cm • Radio opaque • Should be of inert material, non- irritant to tissue
Double J Stent, Sterile, Both Ends Open, size 5F, length 20 cm • Radio opaque • Should be of inert material, non- irritant to tissue
Double J Stent, Sterile, One End Closed - size 4F, length 16 cm • Radio opaque • Should be of inert material, non- irritant to tissue
Double J Stent, Sterile, One End Closed, size 5F, length 20 cm • Radio opaque • Should be of inert material, non- irritant to tissue
K Wire, length 375 mm; 1mm Length of wire should be mentioned with specification. As per IS 8261
K Wire, length 375 mm;1.6mm • Length of wire should be mentioned with specification. • As per IS 8261
K Wire, length 375 mm; size 1.8mm • Length of wire should be mentioned with specification. As per IS 8261
Bone cement with antibiotics,fast and slow setting
Sterile Catheter, single Use, for Urinary Drainage(Foley Balloon Catheter), 2 way, Size 14 • Made of Silicone elastomer bonded with Latex • Should have hard plastic valve • Smooth distal end with smooth eyes for a traumatic intubation • Symmetrical Foley Balloon • Balloon Capacity 30+-1 ml • Should conform to IS 11497 • Color coding marking to identify size • Length, wall thickness and ballon capacity should be mentioned as per IS 11497 • Specification for B,C,D,E,F,G should be mentioned as per IS 11497
• Nelaton catherer size14FG Distal end is close and proximal end has female colour code connector • Soft, Kink resistant medical grade PVC tube • Length:40 cm • Individually packed in poly and sterile
Vascular Catheter with metal Guide No. 16, Double Lumen Size 30 cm (Longline IV.)
Vascular Catheter with metal Guide No. 16 Double Lumen Size 45 cm (Longline IV.)
Vascular Catheter with metal Guide No. 18 Double Lumen Size 45 cm (Longline IV.)
Vascular Catheter with metal Guide No. 20 Double Lumen Size 45 cm (Longline IV.)
Vascular Catheter with metal Guide No. 22 Double Lumen Size 45 cm (Longline IV.)
Sterile Disposable (Single Use Teflon/PTFE I.V Cannula with integrated 3 way stop cock Size 26G • Should be packed in transparent single blister pack • Should confirm to IS 10555 standard • (Neonatal IV Cannula Size 26)
STERIMED MEDICAL DEVICES PVT. LTD
VITROMED HEALTHCARE
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.52 MB
Tenderdoc15.pdf
Tender Documents • 2.54 MB
BOQ_420568.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .