Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.4 LAccepted-AOC AT PATEL NAGAR PO PHUSRO BAZA DIST BOKARO | PHUSRO BAZA | BOKARO | L1 | Accepted-AOC L1 bidder is techno commercially qualified. | |
| 2 | Rejected-Technical | - | Rejected-Technical Bid not opened as per NIT terms. | |
| 3 | Rejected-Technical AT DHORI G M COLONY DIST BOKARO JHARKHAND | BOKARO | BOKARO | JHARKHAND | - | Rejected-Technical Bid not opened as per NIT terms. |
Tender Value
Refer Docs
EMD Value
₹7,400
Closing Date
28 Oct 2022, 9:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Staff Officer (EnM)
Office of the General Manager, Dhori Area
Repair and maintenance with diversion of 440V overhead line at Kalyani colony with replacement of under sized and damaged pole with RCC or PCC pole with insulator etc under SDOCM, Dhori area.
2022_CCL_259226_2
GM(D)/SO(EnM)/DA/2022-23/107
Open Tender
Electrical and Maintenance Works
Item Wise
15 days
Dhori Area
Please refer Tender documents.
2 documents required · 2 mandatory
₹7,400
1 Dec 2022
13 Oct 2022
29 Oct 2022
14 Oct 2022
28 Oct 2022
14 Oct 2022
14 Oct 2022 - 22 Oct 2022
Amount
Supply and providing of 200 Kg 9 mtr. Long solid rectangular PCC pole.
Erection of RCC/PCC pole of following length brick ballast and ramming the foundation, finshing with 150 mm thick cement concrete (1:3:6) layer and top with including excavation and refilling etc as required. (200 kg. 9mtr)
Erection ACSR conductor of 7/3.35 mm dia meter to 7/3.35 mm dia meter including binding etc. as required sagging of Dog conductor
Supplying of channel iron 75 mm x 40 mm x 6 mm (7.14 kg per mtr) cross arm for 4 wire O/H line complete with clamps, bolts nuts and washer etc including drilling of holes for insulator pins, etc (as per drawing) and painting with primer and finished paints as required.
Supply and erection of stay set complete (Galvanized) with 19/20 mm dia x 1.8 m long stay rod, anchor plate of size 45cm x 45 cm x 7.5 mm thimble stay clamp, turn buckle (20mm x 60 cm) 7/4.00 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc as required.
Supply and erection of glavanised 'D' iron clamps complete with shackle insulator (100 mm x 110 mm) G.I. bolts nuts and washers, coach screw etc. as required.(For cradling and OH line), 440V grade
Supplying and erection of 100 mm X 80 mm pin insulator complete with G. I. Spindle and nuts etc. as required for 440V grade
Supply of 6 SGW GI wire
Erection of G.I wire 6 SWG including binding etc. as required.
Erection of cradle guard as required
Dismantling of pole/street light standard/ strut embedded in cement concrete foundation etc. as required.
Dismantling of overhead line comprising of aluminium overhead conductor, G.I. wire, cross arm, insulator etc. as required
Supply and erection of 11 KV cross bracing: Supplying and erection of a set cross bracing frame work for 11 KV OH line double pole structure having members fabricated out of 50 mm x 50 mm x 6 mm angle iron top from a rectangle of minimum size) 1400 mm width x 2500 mm height complete with 50 mm x 6mm MS flat clamps bolts nuts incl. drilling holes for insulator pins, bolts an nuts etc. and painting with primer and finish paint as required.
11 KV double pole 75 mm channel iron cross arm: supplying of two lengths of channel iron 75 mm x 40 mm x 5.7 kg/mtr. double pole cross arm for three wire 11 KV overhead line conductors complete with through bolts and nuts for clamping to the poles. 50 mm x 6 mm M.S flat welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arm together, incl. drilling holes for insulator pins/fittings, bolts and nuts etc. and painting with primer and finish paint as required. (6.5' x 8 nos).
Supplying and drawing 2 x 6 sq. mm sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.(For Service connection)
Transporting of pole from Factory to working site.
Total impact of GST for the purpose of CTC
M/S R.N. ELECTRICAL WORKS
M/S ANUPAMA ELECTRICAL WORKS
stage.html
html • 0.04 MB
techsummary_268066.pdf
PDF • 0.80 MB
finsummary_268066.pdf
PDF • 0.80 MB
wo107b.pdf
PDF • 1.10 MB
BOQ Comparative Chart
xlsx • 0.01 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .