Constrcution of 2 No. room in W/S Division Jind
2022_HRY_217962_7
3990
Open Tender
Civil Works
Works
90 days
Jind
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
₹2,520
3 Jun 2022
23 Apr 2022
5 May 2022
23 Apr 2022
4 May 2022
23 Apr 2022
90 days
Amount
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.HSR 4.14.1
Providing and laying 1 :4: 8 ( 1 Cement : 4 coarse sand (zone-Ill) : 8 graded stone aggregate 40 mm nominal size) in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level HSR 6.1.5
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead Of area 3 sq. metres and below HSR 5.29.1
Providing and laying 40 mm thick damp-proof course with cement concrete 1 :2:4 (1 cement : 2 coarse sand (zone-Ill): 4 graded stone aggregate 12.5mm nominal size) HSR 6.8.2
Brick work with common burnt clay non-modular bricks of class designation 7 .5 in superstructure above plinth level up to floor IV level in all shapes and sizes in Cement mortar 1:4 (1 cement: 4 coarse sand) HSR 7.22.1
Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies HSR 6.30.3
Reinforced cement concrete work in beams, suspended floors, cum roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor four level, excluding the cost of centering, shuttering, finishing and reinforcement with 1: 1.5:3 (1 cement : 1.5 coarse sand(zone-111) : 3 graded stone aggregate 20 mm nominal size). HSR 6.16
Steel reinforcement Cold twisted bars for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respectabove plinth level HSR 6.34.3
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. HSR 5.45
1O mm thick cement plaster 1 :4 (1 cement: 4 fine sand) HSR 11.5.3
Providing and laying of Conglomerate floor 25 mm thick cement concrete 1:2:4 on 100 mm cement concrete 1:8:16 and 100 mm sand or stone filling.HSR 10.9
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 2.0 mm thickness, including hinges, jamb, lock jamb, bead Profile E Fixing with adjustable lugs with split end tail to each jamb HSR 13.3.3.1
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, including ISi marked M.S. pressed butt hinges bright finished of required size with necessary screws Second class teak wood 30 mm thick shutters HSR 12.7.1.2
Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows 30 mm thick shutters Second class teak wood HSR 12.19.2.1.1
Preparation of ply wood surface for painting including sand papering the surface and applying filling with approved quality filler consisting of white lead, linseed oil, varnish and chalk mitti including finishing the surface to required finish complete HSR 11.76
Applying pink primer or aluminium priming coat on wood work including preparation of surface, Knotting and stopping etc HSR 11.77
Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade HSR 11.78
Providing and fixing 200x10 mm aluminium tower bolts, ISi marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete HSR 12.99.3
Providing and fixing 300x16 mm aluminium sliding door bolts, ISi marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete HSR 12.98.1
Providing and fixing aluminium handles 100 mm, ISi marked, anodised (anodic coating not less than grade AC 1 O as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete HSR 12.102.2
Providing and fixing aluminium e xtruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS: 3564, embossed on the body, door weight up to 3 6 kg to 80 kg and door width from 701 mm to 1 000 mm), with double speed adjustment with necessary accessories and screws etc. complete. HSR 12.89
Providing and applying two coats white cement based putty of approved brand and manufacturer, over plastered surface and grinding the surface smooth with sand paper to get en even and smooth finish including cost and carriage of all material , labour charges, scaffolding, sundries etc. complete HSR 11.58
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shadeNew work (two or more coats) over and including water thinnable priming coat with cement primer HSR 11.64.1
COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. HSR 23.4.1.1
PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL PVC CONDUIT and MS/GI BOX only for LIGHT/FAN/Call bell point wiring HSR 23.7.1.1
Wiring in PVC conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required Group A HSR 23.4.4.1
Providing and laying brick tiles over mumty roofs, grouted with cement mortar 1 :3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement, over 12 mm layer of cement mortar 1 :3 (1 cement : 3 fine sand) and finished neat: With common burnt clay non-modular brick tiles of class sqm designation 1 O HSR 9.14.1
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .