| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.0 LAccepted-AOC 171 NARAYAN PETH PUNE PUNE MAHARASHTRA 411030 | PUNE | MAHARASHTRA | 411030 | ₹37.0 L Quoted ₹38.4 L | L1 | Accepted-AOC Award of Contract |
| 2 | L2₹39.1 L+₹78,673 (2.05%)Rejected-Finance | ₹39.1 L+₹78,673 (2.05%) | L2 | Rejected-Finance Not Being Lowest |
| 3 | L3₹39.2 L+₹82,723 (2.16%)Rejected-Finance | ₹39.2 L+₹82,723 (2.16%) | L3 | Rejected-Finance Not Being Lowest |
| 4 | L4₹41.4 L+₹3.0 L (7.94%)Rejected-Finance | ₹41.4 L+₹3.0 L (7.94%) | L4 | Rejected-Finance Not Being Lowest |
| 5 | L5₹46.4 L+₹8.1 L (21.0%)Rejected-Finance | ₹46.4 L+₹8.1 L (21.0%) | L5 | Rejected-Finance Not Being Lowest |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
28 Sept 2024, 6:00 pmClosed
Garrison Engineers (North) Ahmednagar
Military Engineer Services Garrison Engineers (North) Nagar Pathardi Road Ahmednagar Fort Ahmednagar 414 002
REPAIR / REPLACEMENT OF EARTHING, DO SWITCH, LIGHTNING ARESTER, LT UG CABLE AND ALLIED SERVICES AT MH, QUEENS LINE, JK ROAD, AUTO REGT AND STN UNITS UNDER GE(N) AHMEDNAGAR.
2024_MES_669208_1
8895/E8
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
Garrison Engineers (North) Ahmednagar
Class D Cat b (i)
8 documents required · 8 mandatory
₹500
Garrison Engineers (North) Ahmednagar
₹98,000
Yes
6 Dec 2024
31 Aug 2024
30 Sept 2024
31 Aug 2024
28 Sept 2024
14 Sept 2024
Amount
Labour for restringing of LT overhead line consisting of 4/5/6 conductors retrieve from ser item no-01 by dismantling taking down, unserviceable , damaged ACSR conductor, repairing wherever required including cutting, re-joining and restringing in, with proper sag, binding to insulator with and including aluminium binding wire complete all as specified and directed. Note : (i) Only good and serviceable conductors are used, unserviceable conductors will be credited to contractor under schedule of credit. (ii) Rate of Transporting of conductor from one site to another site is included this rate.
Supply, fixing and stringing ACSR conductor (Weasel/ Ferret) for overhead line securing on pole complete including binding wire, jointing sleeves aluminium tap and PG clamp etc of any size all as specified and as directed. (Note :- (a)jumper on cutout point/2 pole structure/4 pole structure shall be provided with PVC insulated sleeve. (b) Rate is inclusive of jumper’s materials & tree branch cutting to make a safe distance from overhead line.)
M&L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, botls, washers, welding bending cold or hot, drilling holes for bolts, in any shape or size as indicated or erected and inclusive of one coat of red oxide primer, one under coat and one finishing coat of aluminium paint all as specified and as directed.
M & L for replacement of Pin type, porcelain, vitreous, white, brown or green insulator including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, 100mm height, 65mm dia for 1100 volts grade
M & L for replacement of shackle Type, Porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts, 100mm height and 115mm dia including two nos of galvanised steel strap of size 31x5mm fitted with 14mm dia bolts and nuts all as per directed.
Dismantling of unserviceable existing cross arms made from channels, angles and unserviceable FI clamps, nuts, bolts etc from OH line and removing complete all as specified and as directed.
Dismantling carefully the existing LT overhead line ACSR conductor with cross arm of any size from its position by necessary disconnecting of conductor and removing complete all as specified and as directed.
Supply, erecting and fixing in replacement of true vertical position of steel tubular swaged pole, 9 mtr long complete with cast iron base plate, finial taper plug, bolt, nuts and screws as specified and of type 410 SP-31, conforming to relevant IS, including one primer coat of red oxide and two coats of aluminium paint and two coats of bituminous paint inside and outside of bottom portion up to 1.8 mtr length all as specified and provide circular bend 1 No of length 2 m including taking down existing complete all as specified and directed. (Excavation and earth work , foundation concrete and PCC coping shall be measured and paid separately)
Dismantling stay assembly complete all as specified and directed
S &F PCC Cable route Indicator with suitable reinforcement of size 50 x 10 x 10 cm with letter inscribed on both side as "MES LT CABLE " of specified front side not less than 30 mm as directed and mounted on PCC 40 x 30 x 30 cm complete using PCC 1: 2:4 B1 using 20 mm graded stone aggregate and including painting using cement based paint to the satisfaction of Engr-in-Charge.
M & L for fabrication of bus bar chamber of size 750 (L) x 500 (H) x 300 (B) mm for 415 volts 3 phase 4 wire system , outdoor type, double door, with pedestal mounted, weather and vermin proof fabricated out of 3.15 mm thick MS CRCA sheet with anti-corrosive coating & finally epoxy polyester powder coating of flint grey shade including 3 nos. phase indicating lamps, insertion of suitable cable glands for all incoming and outgoing cable including grouting of panel board 60 cm above & 30 cm below ground level duly supported on 50x50x6mm angle iron frame & welding 45 cm long angle iron legs of size 50x50x6mm on all the four corners embedded in PCC 1:2:4 using 20 mm stone aggregate upto 30 cm depth complete all as specified and directed by Engineer-in-Charge Incoming MCCB : 160 Amps, 4P, 25 KA Busbar Capacity : 300 Amps mounted on DMC/ porcelain insulator support with RYB indicator Outgoing : Suitable for cable upto size 120 Sqmm 1. The Panel Should be approved by CPRI. 2. The rates Quoted shall include for earth work, Plinth protection around the panel apprx 75cm and excavation for angle iron frame for foundation of panel board up to 0.50 m below GL in any type of soil and PCC 1:4:8 type D2 filling in foundation. The ground clearance of panel board shall be 0.40 M from GL to the bottom of panel board.
M & L for fabrication of bus bar chamber of size 750 (L) x 500 (H) x 300 (B) mm for 415 volts 3 phase 4 wire system , outdoor type, double door, with pedestal mounted, weather and vermin proof fabricated out of 3.15 mm thick MS CRCA sheet with anti-corrosive coating & finally epoxy polyster powder coating of flint grey shade including 3 nos. phase indicating lamps, insertion of suitable cable glands for all incoming and outgoing cable including grouting of panel board 60 cm above & 30 cm below ground level duly supported on 50x50x6mm angle iron frame & welding 45 cm long angle iron legs of size 50x50x6mm on all the four corners embedded in PCC 1:2:4 using 20 mm stone aggregate upto 30 cm depth complete all as specified and directed by Engineer-in-Charge Incoming MCCB : 200 AMps ,4P,25 KA Busbar Capacity : 300 AMps mounted on DMC/ porcelain insulator support with RYB indicator Outgoing : Suitable for cable upto size 120 Sqmm 1. The Panel Should be approved by CPRI. 2.The rates Quoted shall include for earth work, Plinth protection around the panel apprx 75cm and excavation for angle iron frame for foundation of panel board up to 0.50 m below GL in any type of soil and PCC 1:4:8 type D2 filling in foundation. The ground clearance of panel board shall be 0.40 M from GL to the bottom of panel board.
M&L for pruning and removing of tree branches touching to electric overhead lines wild growth around LT /HT overhead lines and around pole and stay complete to make clear span of 2 Mtr of tree both side of the OH line with JCB, Cutter and all tools, plants etc all as directed by Engineer-in-Charge. Note : (i) Distance between pole to pole will be measured and paid. (ii) Contractor has to take upmost care to avoid damage to existing lines/structures if Any breakdown of line caused during punning shall be made good without any extra cost. (iii) The contractor has to ensure the proper safety of the tradesman’s to avoid any mishappening. If any mishappening occurs the contractor will be solely responsible for it.
Supply M&L for earthing complete with galvanized steel earth plate electrode of size 60cm X 60 cm X 6 mm buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of plate not less than 1.5 m below the normal ground level connected to GI earth strip 32 X 6 mm as earth lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel, protected by GI pipe light grade 40mm bore all as shown on electrical plate No 3 of SSR Part-I connected to earth test point electrode, PCC pit with RCC cover, funnel with wire mesh, watering pipe 20mm dia protection pipe etc and testing on completion complete all as specified and directed. Note No 1 :- The unit rate shall also include for earth work in hard/dense soil, PCC (1:3:6) type C1 chamber, RCC 1:2:4 type B-1 cover 50 mm thick reinforced with 8 mm dia TMT bar @ 150 mm c/c both ways, funnel with watering pipe 20 mm dia medium grade, GI protection pipe light grade 40 mm dia and wire mesh complete in addition to item No 1 (a) to (e) of preamble (Notes) under sub-heading earthing, specified on Serial Page No 389 of SSR Part –I. Note No 2 :- Earthing strip and GI protection pipe beyond 7.5 m will be measured and paid separately if required (iii) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself.
Supply M&L for earthing complete with galvanized steel earth plate electrode of size 60cm X 60 cm X 6 mm buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of plate not less than 1.5 m below the normal ground level connected to GI earth strip 25 x4 mm as earth lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel, protected by GI pipe light grade 40mm bore all as shown on electrical plate No 3 of SSR Part-I connected to earth test point electrode, PCC pit with RCC cover, funnel with wire mesh, watering pipe 20mm dia protection pipe etc and testing on completion complete all as specified and directed. Note No 1 :- The unit rate shall also include for earth work in hard/dense soil, PCC (1:3:6) type C1 chamber, RCC 1:2:4 type B-1 cover 50 mm thick reinforced with 8 mm dia TMT bar @ 150 mm c/c both ways, funnel with watering pipe 20 mm dia medium grade, GI protection pipe light grade 40 mm dia and wire mesh complete in addition to item No 1 (a) to (e) of preamble (Notes) under sub-heading earthing, specified on Serial Page No 389 of SSR Part –I. Note No 2 :- Earthing strip and GI protection pipe beyond 7.5 m will be measured and paid separately if required (iii) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself.
M & L for painting of Street light poles of any type (with hydraulic vehicle / ladder) including cross arms, channel, flat iron clamps etc 9/11 mtr long in two coats of aluminium paint and one coat of red oxide as primer including writing of pole nos (Yellow circle and Number in black) and providing 3 Nos of radium with width 50 mm size band / strap with Red, Yellow, Green colour 300 mm apart from plinth block around the pole etc complete as all as specified and directed in Engr-in- Charge. Note:- Hydrolic Vehicle / Ladder for painting is responsibility of contractor and rate of Hydrolic vehicle and ladder including in quoted rate.
Supply & Fixing and testing of LT cable 1100 volts grade, XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) ISI Marked with aluminium conductor suitable for earthed system of size 400 sq mm 3.5 core in trenches, on poles and in ducts complete all as specified and directed by Engr in charge.
-- do-- all as per Sr Item No 17 above but size 240 sq mm 3½ core
-- do-- all as per Sr Item No 17 above but size 185 sq mm 3½ core
-- do-- all as per Sr Item No 17 above but size 120 sq mm 3½ core
-- do-- as per Sr Item No 17 above but size 95 sq mm 3½ core
-- do-- all as per Sr Item No 17 above but size 70 sq mm 3½ core
-- do-- all as per Sr Item No 17 above but size 50 sq mm 3½ core
-- do-- all as per Sr Item No 17 above but size 25 sq mm 3.5 core
-- do-- all as per Sr Item No 17 above but size 16 sq mm 4 core
-- do-- all as per Sr Item No 17 above but size 10 sq mm 4 core
-- do-- all as per Sr Item No 17 above but size 10 sq mm 2 core
Excavation in trenches n exc 1.5 mtr in depth and not exceeding 1.5 Mtr wide for laying of cable/pipe etc and getting out in any type of soil complete all as specified and directed.
--ditto-- All as per Item No.28 above but exceeding 1.5 mtr & not exceeding 3 mtr in depth.
Returning filling in trenches excavated soil including spreading levelling watering and well ramming in layers n.exc 25 cm thick each layer as in soil complete all as specified nad directed..
Removing excavated materials n.exc 50 mtr depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified nad directed.
Supply & laying of HDPE DWC pipe ISI mark of outer dia 110 mm polyethylene with smooth internal and profiled external surface for non-pressure underground cable including coupler and bends etc complete all as specified and directed by Engineer-in-Charge Make : Supreme / Infra / Astral/Prince/Jain irrigation
Supply & laying of HDPE DWC pipe ISI mark of outer dia 63 mm polyethylene with smooth internal and profiled external surface for non-pressure underground cable including coupler and bends etc complete all as specified and directed by Engineer-in-Charge Make : Supreme / Infra / Astral/Prince/Jain irrigation
Supply, installation, testing and commissioning factory made LT feeder pillar panel CPRI approved, size of panel as per CPRI Specification, double door floor mounted outdoor type,as per IP-65 grade, made out of CRCA sheet 3 mm thick of outer body of suitable size with aluminium bus bar 600 Amps,4 strip,(3 phase & Neutral) complete drilled, insulated with colour coded insulation tape, mounted on insulators etc with RYB indicator, internal wiring with suitable size of copper wire, panel should be dust proof, vermin proof, powder coated, locking should be screw type, mechanical type, inter locking, should have danger notice for 415 volt, AC, mounted on 50 x50 x6 mm angle iron frame having minimum 2 feet ground clearance duly embedded in and including PCC block(1:2:4) type B1 foundation for fixing of panel complete including termination of all incoming and outgoing cables with suitable size thimbles/lugs and glands Nuts & Bolts complete all as specified and directed. BR1 (i) MCCB 315 Amp thermal and magnetic adjustable type with, 4 Pole, 50 KA - 01 No. (Ics=100%Icu) (ii) Didital Multimeter with Suitable CTS – 01 No (iv) Indicating lamp LED type one set in incoming phases. (v) Internal wiring with PVC insulated copper conductor multi stranded cable 1100 Volt grade IS 694 marked of appropriate gauge including all copper lugs (vi) Connection from MCCB to Busbar shall be of solid Aluminium conductor (vii) MCCB shall be provided with suitable spreader of aluminium conductor for fixing of incoming cable
Outgoing ways :- MCCB 200 Amps, thermal and magnetic adjustable type ,4 pole,36 KA-02 Nos (Ics=100%Icu MCCB 63 Amps thermal and magnetic adjustable type ,4 pole,25 KA-02 Nos (Ics=100%Icu) (vii) Spare chamber for MCCBs - 01 Nos 1. The Panel should be approved by CPRI. 2. The rates Quoted shall include for earth work, Plinth protection around the panel apprx 75cm and excavation for angle iron frame for foundation of panel board up to 0.50 m below GL in any type of soil and PCC 1:4:8 type D2 filling in foundation. The ground clearance of panel board shall be 0.40 M from GL to the bottom of panel board.
Supply, installation, testing and commissioning factory made LT feeder pillar panel CPRI approved, size of panel as per CPRI Specification, double door floor mounted outdoor type as per IP-65 grade, made out of CRCA sheet 3.15 mm thick of outer body of suitable size with aluminium bus bar 400 Amps,4 strip,(3 phase & Neutral) complete drilled, insulated with colour coded insulation tape, mounted on insulators etc with RYB indicator, internal wiring with suitable size of copper wire, panel should be dust proof, vermin proof, powder coated, locking should be screw type, mechanical type, inter locking, should have danger notice for 415 volt,AC, mounted on 50 x50 x6 mm angle iron frame having minimum 2 feet ground clearance duly embedded in and including PCC block(1:2:4) type B1 foundation for fixing of panel complete including ternination of all incoming and outgoing cables with suitable size thimbles/lugs and glands Nuts & Bolts complete all as specified and directed. sub pael f qtr (i) MCCB 200 Amp thermal and magnetic adjustable type with, 4 Pole, 36 KA - 01 No. (Ics=100%Icu) (ii) Didital Multimeter with Suitable CTS – 01 No (iv) Indicating lamp LED type one set in incoming phases. (v) Internal wiring with PVC insulated copper conductor multi stranded cable 1100 Volt grade IS 694 marked of appropriate gauge including all copper lugs (vi) Connection from MCCB to Busbar shall be of solid Aluminium conductor (vii) MCCB shall be provided with suitable spreader of aluminium conductor for fixing of incoming cable
Outgoing ways :- MCCB 32 Amps thermal and magnetic adjustable type ,4 pole, 36 KA-07 Nos (Ics=100%Icu) (vii) Spare chamber for MCCBs - 01 Nos. 1. The Panel should be approved by CPRI. 2. The rates Quoted shall include for earth work, Plinth protection around the panel apprx 75cm and excavation for angle iron frame for foundation of panel board up to 0.50 m below GL in any type of soil and PCC 1:4:8 type D2 filling in foundation. The ground clearance of panel board shall be 0.40 M from GL to the bottom of panel board.
Supply, installation, testing and commissioning factory made LT feeder pillar panel CPRI approved, size of panel as per CPRI Specification, double door floor mounted outdoor type, as per IP-65 grade made out of CRCA sheet 3.15 mm thick of outer body of suitable size with aluminium bus bar 500 Amps,4 strip,(3 phase & Neutral) complete drilled, insulated with colour coded insulation tape, mounted on insulators etc with RYB indicator, internal wiring with suitable size of copper wire, panel should be dust proof, vermin proof, powder coated, locking should be screw type, mechanical type, inter locking, should have danger notice for 415 volt, AC, mounted on 50 x50 x6 mm angle iron frame having minimum 2 feet ground clearance duly embedded in and including PCC block(1:2:4) type B1 foundation for fixing of panel complete including termination of all incoming and outgoing cables with suitable size thimbles/lugs and glands Nuts & Bolts complete all as specified and directed. ECHS (i) MCCB 250 Amp thermal and magnetic adjustable type with , 4 Pole,50 KA - 01 No. (Ics=100%Icu) (ii) Didital Multimeter with Suitable CTs – 01 No (iv) Indicating lamp LED type one set in incoming (v) Internal wiring with PVC insulated copper conductor multi stranded cable 1100 Volt grade IS 694 marked of appropriate gauge including all copper lugs (vi) Connection from MCCB to Busbar shall be of solid Aluminium conductor (vii) MCCB shall be provided with suitable spreader of aluminium conductor for fixing of incoming cable
Outgoing ways :- MCCB 160 Amps thermal and magnetic adjustable type ,4 pole, 36 KA-01 Nos (Ics=100%Icu) MCCB 125 Amps thermal and magnetic adjustable type,4 pole, 36 KA-02 Nos (Ics=100%Icu) MCCB 63 Amps thermal and magnetic adjustable type 4 pole,36 KA-01 Nos (Ics=100%Icu) ( vii) Spare chamber for MCCBs - 01 Nos 1. The Panel should be approved by CPRI. 2. The rates Quoted shall include for earth work Plinth protection around the panel apprx 75cm and excavation for angle iron frame for foundation of panel board up to 0.50 m below GL in any type of soil and PCC 1:4:8 type D2 filling in foundation. The ground clearance of panel board shall be 0.40 M from GL to the bottom of panel board.
Supply, installation, testing and commissioning factory made LT feeder pillar panel CPRI approved, size of panel as per CPRI Specification, double door floor mounted outdoor type as per IP-65 grade, made out of CRCA sheet 3.15 mm thick of outer body of suitable size with aluminium bus bar 400 Amps,4 strip,(3 phase & Neutral) complete drilled, Insulated with colour coded insulation tape, mounted on insulators etc with RYB indicator, internal wiring with suitable size of copper wire, panel should be dust proof, vermin proof, powder coated, locking should be screw type, mechanical type, inter locking should have danger notice for 415 volt, AC, mounted on 50 x50 x6 mm angle iron frame having minimum 2 feet ground clearance duly embedded in and including PCC block(1:2:4) type B1 foundation for fixing of panel complete including termination of all incoming and outgoing cables with suitable size thimbles/lugs and glands Nuts & Bolts complete all as specified and directed. NALA (i) MCCB 200 Amp thermal and magnetic adjustable type with , 4 Pole,50 KA - 01 No. (Ics=100%Icu) (ii) Didital Multimeter with Suitable CTs – 01 No (iv) Indicating lamp LED type one set in incoming phases. (v) Internal wiring with PVC insulated copper conductor multi stranded cable 1100 Volt grade IS 694 marked of appropriate gauge including all copper lugs (vi) Connection from MCCB to Busbar shall be of solid Aluminium conductor (vii) MCCB shall be provided with suitable spreader of aluminium conductor for fixing of incoming cable
Outgoing ways :- MCCB 125 Amps thermal and magnetic adjustable type ,4 pole, 36 KA-01 Nos (Ics=100%Icu) MCCB 63 Amps thermal and magnetic adjudtable type ,4 pole,36 KA-02 Nos (Ics=100%Icu) ( vii) Spare chamber for MCCBs - 01 Nos Notes :- 1. The Panel Should be approved by CPRI. 2. The rates Quoted shall include for earth work,Plinth protection around the panel apprx 75cm and excavation for angle iron frame for foundation of panel board up to 0.50 m below GL in any type of soil and PCC 1:4:8 type D2 filling in foundation. The ground clearance of panel board shall be 0.40 M from GL to the bottom of panel board.
Supply, installation, testing and commissioning factory made LT feeder pillar panel CPRI approved, size of panel as per CPRI Specification, double door floor mounted outdoor type, as per IP-65 grade, made out of CRCA sheet 3.15 mm thick of outer body of suitable size with Aluminium bus bar 250 Amps,4 strip,(3 phase & Neutral) complete drilled, insulated with colour coded insulation tape, mounted on insulators etc with RYB indicator, internal wiring with suitable size of copper wire, panel should be dust proof, vermin proof, powder coated, locking should be screw type, mechanical type, inter locking, should have danger notice for 415 volt,AC, mounted on 50 x50 x6 mm angle iron frame having minimum 2 feet ground clearance duly embedded in and including PCC block(1:2:4) type B1 foundation for fixing of panel complete including termination of all incoming and outgoing cables with suitable size thimbles/lugs and stainless steel glands Nuts & Bolts complete all as specified and directed. Note: All MCCB Shall be thermal and Magnetic adjustable type as per IEC 6047-II PT (i) Incoming MCCB 4P 100 Amp, 36 KA -01 No ( Ics = 100% Icu) (ii) Outgoing MCCB 4P 63 Amp, 25 KA -02Nos ( Ics = 100% Icu) (iii) Digital voltmeter & Ammeter with necessary CTs (iv) Internal wiring with PVC insulated, multi stranded copper conductor cable, 1100 V grade, IS 694 marked of appropriate size but not less than 2.5 sqmm (v) Phase indicating LED lamps (R-Y-B) -01 SET (vi) Spare chamber for MCCBs - 01 Nos
Supply, installation, testing and commissioning factory made LT feeder pillar panel CPRI approved, size of panel as per CPRI Specification, double door floor mounted outdoor type,as per IP-65 grade, made out of CRCA sheet 3 mm thick of outer body of suitable size with aluminium bus bar (100 x10 mm) 1000 Amps,4 strip,(3 phase & Neutral) complete drilled, insulated with colour coded insulation tape, mounted on insulators etc with RYB indicator, internal wiring with suitable size of copper wire, panel should be dust proof, vermin proof, powder coated, locking should be screw type, mechanical type, inter locking, should have danger notice for 415 volt, AC, mounted on 50 x50 x6 mm angle iron frame having minimum 2 feet ground clearance duly embedded in and including PCC block(1:2:4) type B1 foundation for fixing of panel complete including termination of all incoming and outgoing cables with suitable size thimbles/lugs and glands Nuts & Bolts complete all as specified and directed.( R C Road) (i) MCCB 630 Amp adjustable type with , 4 Pole,50 KA - 01 No. (Ics=100%Icu) (ii) Volt meter 0 to 500 Volts, Square flush pattern, digital type – 01 No (iii) Amp meter square flush pattern 0 to 400 Amps digital type -01 No. (iv) Indicating lamp LED type one set in incoming phases. (v) Internal wiring with PVC insulated copper conductor multi stranded cable 1100 Volt grade IS 694 marked of appropriate gauge including all copper lugs (vi) Connection from MCCB to Busbar shall be of solid Aluminium conductor (vii) MCCB shall be provided with suitable spreader of aluminium conductor for fixing of incoming cable (viii) KWH meter CT operated as per suitable capacity of LT Panel
Outgoing ways :- MCCB 200 Amps adjudtable type ,4 pole,25 KA-03 Nos (Ics=100%Icu) MCCB 125 Amps adjudtable type ,4 pole,25 KA-03 Nos (Ics=100%Icu) MCCB 63 Amps adjudtable type ,4 pole,25 KA-01 Nos (Ics=100%Icu) Spare chamber for MCCBs - 01 Nos Notes :- 1. The Panel should be approved by CPRI. 2. The rates Quoted shall include for earth work, Plinth protection around the panel apprx 75cm and excavation for angle iron frame for foundation of panel board up to 0.50 m below GL in any type of soil and PCC 1:4:8 type D2 filling in foundation. The ground clearance of panel board shall be 0.40 M from GL to the bottom of panel board.
M&L for GI Tubes of size 40mm dia Medium grade, galvanised, with all fitting , laid in trenches for protection of cable in road /drain crossing complete all as specified and as directed.
M&L for GI Tubes of size 50mm dia Medium grade, galvanised, with all fitting , laid in trenches for protection of cable in road /drain crossing complete all as specified and as directed.
M&L for GI Tubes of size 80mm dia Medium grade, galvanised, with all fitting , laid in trenches for protection of cable in road /drain crossing complete all as specified and as directed.
M&L for road cutting upto 300mm deep and 200mm wide for crossing GI pipe line through road including making good the disturbed surface by filling mass concrete( 1:2:4) etc complete all as specified and directed by Engineer-in-Charge. Note : Rate of mass concrete is included in quoted rate.
Demolition of u/s cement concrete in copings etc complete all as specified and directed by Engineer-in-Charge.
M & L for PCC (1:2:4) type C-2 using 20mm grade stone aggregates for coping and similar work all as specified and directed.
S&F PVC Junction box of size 200x175x100mm, IP 66 with hinged door including locking arrangement and MCB SP 6 Amp with necessary nut bolt etc and including TPN aluminium bus bar mounted on insulators with suitable holes to provide incoming and outgoing LT cables and street light MCB complete all as specified and directed
Supply and fixing wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, Three core cable in surface/recessed as required 2x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire (From PVC Junction box to Security light)
Supply and fix in repair of jumper with PVC shielded aluminium single core power cable of size 95 Sqmm,11KV, with heat shrinkle sleeve /lugs at both ends confirming to IS 8098 including taking down unsv cable complete all as specified and directed. Make : Havells/ Polycab/KEI
Supply and fixing in replacement of MCB DP, 40 Amps with 10 KA breaking / rupturing capacity including necessary connection complete all as directed.
Supply and fix in replacement MCB, SP, 6 to 32 Amps 10 KA breaking / rupturing capacity including necessary connection with suitable size of copper cable complete all as directed.
Supply and fixing in existing panel board for replacement MCCB, 4 Pole, 400 Amps , with breaking capacity 50 KA , Thermal and magnetic adjustable including Spreader of suitable size (Ics=100%Icu) 415 volt, 50 HZ conforming to IEC:60947-II/IS:13947-II and connecting all as directed.
--ditto-- All as per Sr item No 51 above but 200 Amps 36 KA breaking capacity.
--ditto-- All as per Sr item No 51 above but 250 Amps 36 KA breaking capacity.
--ditto-- All as per Sr item No 51 above but 160 Amps 25 KA breaking capacity.
--ditto-- All as per Sr item No 51 above but 100 Amps 25 KA breaking capacity.
M&L for painting of cooping of pole including cleaning and one coat of primer and two coat of Apex (off white colour) complete all as specified and directed by engr in charge
M&L Heat shrinkable straight through joint, with including jointing materials and necessary earth work suitable for 1100 Volts , XLPE LT cable of size 16-25 sq.mm , 3.5/4 core, including fixing, jointing and testing complete all as specified and as directed.
M&L Heat shrinkable straight through joint, with including jointing materials and necessary earth work suitable for 1100 Volts , XLPE LT cable of size 35-95 sq.mm , 3.5/4 core, including fixing, jointing and testing complete all as specified and as directed.
M&L Heat shrinkable straight through joint, with including jointing materials and necessary earth work suitable for 1100 Volts , XLPE LT cable of size 120-240 sq.mm , 3.5/4 core, including fixing, jointing and testing complete all as specified and as directed.
Supply and replacement of 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension GI wire, twin core cable flat or circular with size 4sqmm. Note : Rate of 4 mm GI wire included in quoted rate
--ditto-- All as per Item No 60 above but 10 sqmm 2 Core
--ditto-- All as per Item No 60 above but 6 sqmm 2 Core
Supply, install testing and commissioning of Automatic transfer switch with complete Enclosed type , frame 2, three phase 415 Volt, 50Hz, 4 pole with capacity 200 Amp having suitable to 02 incoming and one out going with inbuilt time delay. The ATS should be capable of transferring load of first feeder to second feeder on failure of first feeder and wise versa automatically. the switch should have provision for automatic operation as well as manual operation and should be able for wall mounted including sheet metal enclosure with extended terminal if required easy fixing of incoming and outgoing connection with free maint of work. Make: Havells / L&T/ Indoasian.
M&L Outdoor type bus bar LT panel box, platform mounted, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos aluminium bus bar, of capacity 400 Amps fabricated in factory having modern fabrication facility duly powder coated painting, dust and vermin proof, degree of protection not less than IP-55, the panel shall be made out of 3.00mm thick CRCA mild steel sheet, front door (01 layer) and rear door (01 layer) opening facility and 4 side slanting canopy type roof on top and suitable angle iron mounting base frame at bottom min 0.6 Mtr above ground level including installation, commissioning, testing and necessary PCC work etc complete all as specified and directed by Engineer-in-Charge. (a) Aluminium Bus-bar 4 Strip, 400 Amp, 415 Volt - 01 Set (b) MCCB 160 Amp - 01 No, 4 Pole, 16 KA (Incoming) (c) MCB 63 Amp, TPN, 16 kA, 415 Volt - 05 No. Notes :- 1. The Panel Should be approved by CPRI. 2.The rates Quoted shall include for earth work, Plinth protection around the panel apprx 75cm and excavation for angle iron frame for foundation of panel board up to 0.50 m below GL in any type of soil and PCC 1:4:8 type D2 filling in foundation. The ground clearance of panel board shall be 0.40 M from GL to the bottom of panel board.
Supply and fix in repairs change over switch existing panel, wall or LT pole of any size and any type on load type, triple pole and neutral, 400 Amps, 415 V, 50 Hz front handle operated, including connecting and testing all as directed. MAKE: ABB / L&T/Legrands/Siemens.
M&L for street light control board / box of size 0.50 X 0.50 X 0.20 m made out of 1.60 mm thick MS sheet fixed / mounted on pole by means of 2 Nos of FT clamps of size 25 X 3 mm comprising the following enclosures and connecting with suitable size of copper cable all as directed:- a) MCB, TPN, 63 Amps, - 01 No b) Timer switch, Astronomical type operating on 110 / 240 / 415 Volts, 50 Hz. b) Contactor ML 2, 63 Amps,415 Volt - 01 No c) Auto and manual switch
Supply and fixing in replacement of ALL-IN-ONE Solar street light fitting,40 watt led lamp, Range ( 2 days back up) including LED light, MPPT SCC, Mono crystalline SPV Panel ,lithium ferro phosphate battery with inbuilt BMS technology, high efficiency, LED ,MPPT Solar charge controller and Aluminium Extruded body and is specially programmed to automatically control the dimming and brightness of light which increase the bach up time complete including proving 6 mtr GI tubular pole designed especially for solar light fitting including PCC work and foundation and couping ( as per manufacture instruction) ,earth work complete all as specified and directed .Make : Havells cat No SOLAR AIO 40 watt and equivalent in Bajaj/Philips
S&F in replacement of HT 11000V out door non-linear type lightening arrestor with mountings, accessories complete fixed on cross arms of two pole structure / GI flat strip and connect with same size of ACSR conductor encased in PVC alkathine pipe with all fittings connected to earth strip with nuts, bolts and washers, transmission class having discharge capacity of 10 KA and suitable for working pressure 9 KV RMS complete including taking down old lightning arrestor all as specified and as directed including dismantling existing one all as specified and as directed.
S&F drop out fuse unit, expulsion type for outdoor air break gang operated switch, single pole mounted on and including insulators for 11000V working pressure fixed to and including MS channel with nuts, bolts and washer etc synthetic bounded fuse tube complete with line capcity suitable for current carrying capacity upto 100 Amps all as directed including taking down old one all as specified and as directed
M & L for cleaning /cutting of grass using grass cutter machine around transformer/ two pole structure/four pole structure and Spreading herbicide on grass for anti-grass treatment all over the substation complete all as specified and directed. Note : Each job contain one substation of any size
AZAD SERVICES (BID ID -3119221)
AMAR CONSTRUCTION (BID ID -3119158)
vedant engineering enterprises (BID ID -3105016)
M/S YASH ELECTRICAL (BID ID -3118396)
Maruti Abhiyantriki (BID ID -3101539)
KAMINS CARE (BID ID -3119162)
Mahindra Electric Stores (BID ID -3103702)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .