Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.8 LAccepted-AOC A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹30.4 L+₹1.5 L (5.17%)Rejected-Finance | L2 | Rejected-Finance Rejected not being lowest | |
| 3 | L3₹35.3 L+₹6.5 L (22.4%)Rejected-Finance NO 9 BYRAVESHWARA INDUSTRIAL ESTATE ANDRAHALLI MAIN ROAD NEAR PEENYA 2ND STAGE BENGALURU 560 091 | BENGALURU URBAN | KARNATAKA | 560091 | L3 | Rejected-Finance Rejected not being lowest | |
| 4 | L4₹42.2 L+₹13.3 L (46.0%)Rejected-Finance 00 BACHUAPAR RAJESULTANPUR ALAPUR AMBEDKAR NAGAR UTTAR PRADESH 224176 | AMBEDKAR NAGAR | UTTAR PRADESH | 224176 | L4 | Rejected-Finance Rejected not being lowest | |
| 5 | L5₹49.8 L+₹20.9 L (72.4%)Rejected-Finance A 303 VEENA CGHS LTD PLOT NO 5D SECTOR 22 DWARKA NEW DELHI 110077 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110077 | L5 | Rejected-Finance Rejected not being lowest |
| Sl No | Description | Qty | Unit | Ridhi engineers and builders L5 | Vijay Electricals L3 | ALLIED CONSTRUCTION L2 | M/S ADHIKARI CONSTRUCTION CO. L1 | SB ENTERPRISES L4 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Opening of the VCB , 11 KV 400 to 800 Amps of any make by removing of the Breaker from the existing position after disconnecting all the connections from the system, servicing, Overhauling of the same, checking of the same for proper operation, spring charge, charged control cables are fastened tightly to the terminals, any abnormality, VCB, cleaning the surface of the insulators, fasten the bolts, checking and correcting interrupting units, mechanism, linkages etc, fasten the hardwares of control wiring, check that the split pins, Circlips, dowell pins etc. have not come out and are intact, lubricate the mechanism, moving parts by castrol, all purpose grease or equivalent, check that the vaccum pots/chambers is within limit including opening of the shutters properly, replacing of the trip catch, roller, holding catch, stopper, close push button, closing cum reassembling, controll limit switches reconnecting of the breaker for smooth functioning complete all as specified and directed by Engr-in-Charge.
(Note:- Spare parts will be paid separtly under respective items) | 33 | Each Job | 9,900 ₹3,26,700 | 2,999 ₹98,967 | 3,000 ₹99,000 | 999 ₹32,967 Lowest | 6,009 ₹1,98,297 |
| 2.00 | Supply in replacement of space heaters of 1 KW, 220Volts complete all as specified and directed by Engr-in-Charge. | 15 | Each | 750 ₹11,250 | 999 ₹14,985 | 600 ₹9,000 | 999 ₹14,985 | 599 ₹8,985 Lowest |
| 3.00 | Supply in replacement of thermostate adjustable type 30 to 120 degree C complete all as specified and directed by Engr-in-Charge. | 12 | Each | 150 ₹1,800 Lowest | 999 ₹11,988 | 600 ₹7,200 | 999 ₹11,988 | 199 ₹2,388 |
| 4.00 | Supply in replacement of motor & gear assembly 230V AC suitable for 400/630/800 amps, 11 KV HT VCB including testing & puting on load complete all as specified and directed by Engr-in-Charge. | 6 | Each | 3,500 ₹21,000 | 999 ₹5,994 Lowest | 1,800 ₹10,800 | 999 ₹5,994 Lowest | 1,199 ₹7,194 |
| 5.00 | Supply in replacement (at site on VCBs as per existing size), male contact (Copper) suitable for HT 11 KV power supply complete all as specified and directed by Engr-in-Charge. | 8 | Each | 900 ₹7,200 | 999 ₹7,992 | 800 ₹6,400 | 999 ₹7,992 | 299 ₹2,392 Lowest |
| 6.00 | Supply in replacement (at site on VCBs as per existing size), Female contact (Copper) suitable for HT 11 KV power supply complete all as specified and directed by Engr-in-Charge. | 8 | Each | 900 ₹7,200 | 999 ₹7,992 | 800 ₹6,400 | 999 ₹7,992 | 299 ₹2,392 Lowest |
| 7.00 | Supply in replacement of Current Transformers draw type 11kV, 300/150/1-1, Core1: Class 5P10, 10VA, Core2: Class 0.5, 10 VA complete all as specified and directed by Engr-in-Charge. | 1 | Set of 3 | 5,000 ₹5,000 | 9,999 ₹9,999 | 3,000 ₹3,000 | 999 ₹999 Lowest | 8,899 ₹8,899 |
| 8.00 | Supplying and fixing in replacement of Current Transformers draw type 11kV, 200/100/1-1, Core1: Class 5P10, 10VA, Core2: Class 0.5, 10 VA complete all as specified and directed by Engr-in-Charge. | 1 | Set of 3 | 5,000 ₹5,000 | 9,999 ₹9,999 | 3,000 ₹3,000 | 999 ₹999 Lowest | 7,799 ₹7,799 |
| 9.00 | Supplying and fixing in replacement of Current Transformers draw type 11kV, 100/50/1-1, Core1: Class 5P10, 10VA, Core2: Class 0.5, 10 VA complete all as specified and directed by Engr-in-Charge. | 1 | Set of 3 | 5,000 ₹5,000 | 9,999 ₹9,999 | 3,000 ₹3,000 | 999 ₹999 Lowest | 7,709 ₹7,709 |
| 10.00 | Taking down the old/unserviceable potential transformer supply & fix new 11KV/110V/100VA with drawable type and epoxy incl PT grid with risers complete suitable for HT 11KV panel complete incl testing & commissioning complete all as specified and directed by Engr-in-Charge. | 1 | Each Set | 9,000 ₹9,000 | 9,999 ₹9,999 | 18,000 ₹18,000 | 999 ₹999 Lowest | 9,999 ₹9,999 |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
9 Jan 2026, 6:00 pmClosed
GE Utility Electric Supply
GE Utility Electric Supply Delhi Cantt-10
REPAIR REPLACEMENT OF STREET LIGHTS POLE TIMER CONTACTORS LT PANEL ALONG WITH CONNECTED ITEMS LT CABLES EARTHING POLE PAINTING FILTERATION DEHYDRATION OF OUTDOOR INDOOR 11 .415 KV DISTRUBUTION TRANSFORMER ALONG WITH RE WINDING WITH CONNECTED ACE
2025_MES_745367_1
GE ELECT/D-80/2025-2026
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE Utility Electric Supply
As Per Tender Documents
7 documents required · 7 mandatory
₹500
GE Utility Electric Supply
₹99,000
Yes
31 Jan 2026
19 Dec 2025
12 Jan 2026
19 Dec 2025
9 Jan 2026
2 Jan 2026
Supply in replacement of space heaters of 1 KW, 220Volts complete all as specified and directed by Engr-in-Charge.
Supply in replacement of thermostate adjustable type 30 to 120 degree C complete all as specified and directed by Engr-in-Charge.
Supply in replacement of motor & gear assembly 230V AC suitable for 400/630/800 amps, 11 KV HT VCB including testing & puting on load complete all as specified and directed by Engr-in-Charge.
Supply in replacement (at site on VCBs as per existing size), male contact (Copper) suitable for HT 11 KV power supply complete all as specified and directed by Engr-in-Charge.
Supply in replacement (at site on VCBs as per existing size), Female contact (Copper) suitable for HT 11 KV power supply complete all as specified and directed by Engr-in-Charge.
Supply in replacement of Current Transformers draw type 11kV, 300/150/1-1, Core1: Class 5P10, 10VA, Core2: Class 0.5, 10 VA complete all as specified and directed by Engr-in-Charge.
Supplying and fixing in replacement of Current Transformers draw type 11kV, 200/100/1-1, Core1: Class 5P10, 10VA, Core2: Class 0.5, 10 VA complete all as specified and directed by Engr-in-Charge.
Supplying and fixing in replacement of Current Transformers draw type 11kV, 100/50/1-1, Core1: Class 5P10, 10VA, Core2: Class 0.5, 10 VA complete all as specified and directed by Engr-in-Charge.
Taking down the old/unserviceable potential transformer supply & fix new 11KV/110V/100VA with drawable type and epoxy incl PT grid with risers complete suitable for HT 11KV panel complete incl testing & commissioning complete all as specified and directed by Engr-in-Charge.
Shifting of Transformer from substations to variours substation /transformers locations in the area of AGE(U) E/S No III by road using and removing the faulty transformer by fxing/errecting of the healthy tansformer with the hydra/crane support making the necessary HT/LT cable connections earth connections and restoration of power supply complete all as specified and directed by Engr-in-Charge.
Taking down unserviceable sheet gasket (Cork sheet), Supply and fix synthetic rubberized cork sheet gasket 6mm 2' x 3' size sheet thick for top cover HT/LT bushes at places existing and tighting all the bushings and top cover to avoid any oil leakages of capacity 160 KVA to 500 KVA complete all as specified and directed by Engr-in-Charge.
Taking out old rusted unserviceable LT panel Supply, installing, testing and commissioning in replacement outdoor type stainless steel (SS 316) cubical enclosure compartmentalized exterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc.The outer enclosure shall be made of 3.15 mm thick SS 316 sheet and inner compartment should be 2 mm. The fixing of double doors shall be on SS hinges with anti-theft provision (the door can’t be removed from enclosure without cutting enclosure). All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 316. Sliding handle and locking arrangement front and rear both side . Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. IP-55 class protection and mounted on channel 75 mm welded with panel of SS 316 with 04 Nos foundation bolt of size not less than 20mm dia and 300mm long. The enclosure shall have provision of cable alley . Cable entry from bottom side including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked, 1100 volts grade of appropriate size (but not less than 2.5 sqmm) complete all as specified and directed by Engr-in-Charge.(Location- old APS ) (a) Incoming :- (i) Incomer of the panel having MCCB 4 pole , 630 Amps,50 Hz,415 Volts, 50 KA with microprocessor release - 01 Nos along with sprader terminals , Digital Multifunction Meter (Accuracy class 0.5) with LCD display for measuring of current, voltage, power, power-factor, energy parameters, Total Harmonic Distortion and Maximum Demand Indication etc and shall have RS-485 port for communication on Modbus protocol – 01 No, CTs ratio 400/5 A, Class 1, ISI marked -01 sets of three, Indicating lamp- 01 set of three & Aluminium bus bar of rating 800 Amp, 4 pole , mounted on SMC insulator- set of four. (ii) Digital type Volt meter 0-500 volt - 01 Set (iii) Digital type Amp meter with CT's - 01 No
Material and Labour for replacement Earthing complete with galvanized steel earth plate electrode of size 60cmx60cmx6 mm thick, buried directly in ground (earth pit not less than 2.10 m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level, connected to galvanized iron strip 32 x 6mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel as shown in electrical plate No 3 of SSR Part I, connected to earth test point and the equipment on the other nuts and washers of galvanised ironside complete all as specified, including testing and commissioning complete all as specified and directed by Engr-in-Charge. Note : (a) The unit rates quoted against this item shall be deemed to include the cost of excavation and earth work in any type of soil, common salt & charcoal dust in alternate layers, PCC 1:3:6 as in pit, precast RCC 1:2:4 type B-1 with necessary reinforcement as in cover & frame for pit, funnel, watering pipe 20 mm bore GI pipe light grade, protection pipe 40 mm bore GI pipe medium grade etc. (b) The quoted rates shall also deemed to include the cost of earth test point and earth strip/GI lead wire and protection pipe upto 7.5 meter beyond the earth plates electrode.
Removal of Old deteriorated pole structure & dismantling the complete HT RCC poles to ground level without causing any external damage to the B/R, E/M assets near by with all safety precautions by use of hydra, rope, safety belts & helmets and disposed off the dismantled RCC pole structure within the Cantt area complete all as specified and directed by Engr-in-Charge.
(iv) Indicating Lamps : 01 set (b) Outgoing :- (i) MCCB 4 pole 415 V breaking cap 36 KA , current rating 350 Amps along with sprader terminals. - 01 Nos (ii) MCCB 4 pole 415 V breaking cap 25 KA , current rating 200 Amps along with sprader terminals. - 05 Nos (iii) MCCB 4 pole 415 V breaking cap 25 KA , current rating 160 Amps along with sprader terminals. - 01 Nos (iv) All incoming & outgoing feeders shall be connected by cable through suitable size of gland plate/glands. (v) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint (vi) Indicating Lamps R Y B , LED type01 set
Calibration of all the electromagneitic/ thermal/ microprocessor relays of 11 KV VCB/RMU and setting the relay tripping timings in advance to the feeding sub station to ensure pock wise re-installation of various relays in position with complete testing and commissioning. Ensure proper functioning and complete all as specified and directed by Engr-in-Charge. Note :- (a). Primary & secondary injection kit shall be arranged by the contractor. (b) DC Supply for relay testing shall arranged by the contractor. (c) The contractor shall prepare the relay adjustment and tripping timing chart in the follow up fashion and submit to Engineer-in-Charge
Material and labour for complete bush cutting vegetation around the substations/ transformers lines complete all as specified and directed by Engr-in-Charge.
Filtration/dehydration of 11 KV distrubution transformer oil / Servo voltage stabilizer through filtration plant to improve the dielectric strength/insulation valve of the transformer oil upto 60 KV at a gap of min 2.5 mm of electrodes complete all as specified and directed by Engr-in-Charge. (a) The contractor will take shut down orders in working before commencement of the work (b) The contractor shall ensure no wastage at transformer oil (c) The Contractor is solely responsible for any damage to the transformer during filtration operations. He is responsible for making good any damage to the transformer at his own cost without any extra cost to the departme
nt. (d) The contractor shall ensure that the conservator tanks are full to its level before starting the dehydration. Note : Oil for Top up will be measure and paid seperatly under respective items. (e) The di-electric strenght of oil shall be tested before & after filtration. Test results shall be submitted to engineer-in-charge.
Material and labour for preparation of old painted surfaces of floor mounted indoor/outdoor type transformer from 100 KVA to 400 KVA capacity by cleaning/rubbing with course cloth wire brushes to remove dust deposits oil grease and repainting by applying one coat of spray paint with synthetic enamel paint of approved colour without disturbing/damaging the electrical net work system/equipment including making of capacity /rating /incoming outgoing details in capital english alphabet of size complete all as specified and directed by Engr-in-Charge.
Material and Labour for checking the existing pressure of SF6 Gas in gas chamber of 11 KV, 630 Amps package sub station before filling and topping up to the SF6 gas in the chamber including supervision of gas filling /topping up process and checking the pressure of gas after filling complete all as specified and directed by Engr-in-Charge.
Material and labour for preparation of old painted surfaces of floor mounted indoor/outdoor type transformer from 400 KVA to 630 KVA capacity by cleaning/rubbing with course cloth wire brushes to remove dust deposits oil grease and repainting by applying one coat of spray paint with synthetic enamel paint of approved colour without disturbing/damaging the electrical net work system/equipment including making of capacity /rating /incoming outgoing details in capital english alphabet of size complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of silica gel breather assembly complete with breather unit and silica gel including connecting with proper rubberised gasket and necessary fittings GI fittings for fixing/assembling upto 630KVA transformer complete by removing the unserviceable silica gel breather assembly complete all as specified and directed by Engr-in-Charge.
Supply, filling and for topping up the transformer with new transformer oil duly filtered with filtration plant complete all as specified and directed by Engr-in-Charge. Note : (a) The transformer oil shall be type EHV confirming to IS - 335(2018) (b) Mineral oil grade shall be used. (c) The transformer oil should have a high dielectric strength not less than 60 KV at a gap of min 2.5 mm of electrodes.
Supply and making in replacement new LT 1100 V end termination / lugs/ ferrule with suitable size of aluminium lugs/ferrule duly crimped for LT 3 ½ core armoured aluminium conductor cable after isolating supply to transformer/LT panel and disconnecting brunt/fault cable from the bunch of cables in trenches, galleries, removing cable loop, opening the cable blank and connecting back after end terminals, testing and commissioning and complete all as specified and directed by Engr-in-Charge for following sizes all as specified and as directed of following size:-
Taking down burnt defective drawnout/inlet Valve (Brass any size) and supply and fixing new drawn out/Inlet valve (brass as per existing size) suitable for any make of 63 to 315 KVA Transformer complete all as specified and directed by Engr-in-Charge.
All as per item No 28 above but from 500 KVA to 630KVA complete all as specified and directed by Engr-in-Charge.
All as per item No 26 above but from 500 KVA to 630KVA complete all as specified and directed by Engr-in-Charge.
Taking down defective unserviceable LT bush porcelain insulator and supply and fix news LT bush porcelain insulator with oil seal for transformer outdoor/indoor up to 400KVA complete all as specified and directed by Engr-in-Charge.
Material and Labour for complete removal of old paint from LT panel/ feeder panel of with the help of mechanical tool such as wire brush, scraper and sand paper and painting the prepared surface with two coats of synthetic enamel paint of approved shade over a coat of red oxide zinc chrome primer complete all as specified and directed by Engr-in-Charge.
Taking down defective unserviceable HT bush porcelain insulator and supply and fix news HT bush porcelain insulator for transformer outdoor/indoor up to 400 KVA complete all as specified and directed by Engr-in-Charge.
Lifting of transformer core of capacity 160 to 750 KVA and keeping the core inside oven chamber to removing of moisure and increasing of the insulation value of core and drying the core assembly for minimum 3 days at a temp of 120oC complete all as specified and directed by Engr-in-Charge. Note :- (a) Cost for lifting/lowering and transporting the core of transformer by crane is inclusive. (b) Labour for fixing the connection/removal of connection inside the heating chamber is inclusive. (c) Power consumption for heating core for improving insulation value is inclusive. (d) Temperature 120oC to be maintained and inclusive in rate quoted.
Disconnecting defective out door/indoor transformers, 11KV/433 V of various capacities up to 630 KVA from HT/LT sides taking down transformer oil completely, storing oil in suitable container (to be provided by the contractor), lifting the top cover and core assembly carefully and checking the conditions, refilling the transformer oil completely after necessary repairs, re-taking core assembly and fixing the top cover and painting to transformer complete all as specified and directed by Engr-in-Charge. Note :- (a) Rewinding of transformer shall be measured and paid separately. (b) In case of major repairs/replacement in transformer, which can not be undertaken at site, the transformer shall be shifted to civil workshop and winding and connected accessories (complete transformer) (c) Dismantling of core and repairs shall be measured and paid separately. (d) Shifting of transformer shall be measured and paid separately. (e) Complete gaskets shall be replaced by the contractor rate deemed to be inclusive.
Taking down burnt defective high tension copper coil and supply and fix new HT copper coil made out of proper/ required as per the existing size copper wire enameled of high quality matching with the existing impedance and pre- insulation complete all as specified and directed by Engr-in-Charge. Note : (a) The cost of coil shall be inclusive of varnish sleeving of insulating material. (b) Cost of taking down the clamps, upper channels and core & HT links and re-clamp, positioning with separators, brazing etc completely shall be deemed to be included in the cost.
All as per above item no.33 but of LT copper coil complete all as specified and directed by Engr-in-Charge.
Taking down and opening of HT copper wound loose overheated coil from the limbs of transfomer of various capacities upto 630KVA, and rewinding the same by using the same copper wire after providing DPC and proper insulation etc into the coil of suitable turns etc complete all as specified and directed by Engr-in-Charge.
All as per Item No 35 above, but of LT copper wound complete all as specified and directed by Engr-in-Charge.
Taking down unserviceble tinned copper bus bar of various sizes from HT/LT side cable bushing rods from the transformer of capacities and supply and fix electrolyte tinned copper bus bar of suitable size and length including making holes as required at site to the transformer LT/HT side cable bushing rods complete all as specified and directed by Engr-in-Charge.
Taking down the Defective tap changer assembly ,Supply and fix offload tap changer assembly suitable for any make upto 630KVA transformer with 5 tapping position including opening top cover, conservator etcs complete all as specified and directed by Engr-in-Charge.
Opening of the RMU any size/way , 11 KV 400 to 800 Amps of any make by removing of the Breaker from the existing position after disconnecting all the connections from the system, servicing, Overhauling of the same, checking of the same for proper operation, spring charge, charged control cables are fastened tightly to the terminals, any abnormality, RMU, cleaning the surface of the insulators, fasten the bolts, checking and correcting interrupting units, mechanism, linkages etc, fasten the hardwares of control wiring, check that the split pins, Circlips, dowell pins etc. have not come out and are intact, lubricate the mechanism, moving parts by castrol, all purpose grease or equivalent, check that the vaccum pots/chambers is within limit including opening of the shutters properly, replacing of the trip catch, roller, holding catch, stopper, close push button, closing cum reassembling, controll limit switches reconnecting of the breaker for smooth functioning complete all as specified and directed by Engr-in-Charge.
Supply, installation & commissioning and testing in replacement of DC power pack for RMU comprising 12 V and . 7 AH Complete accessories required for commissioning is included in the scope of work complete all as specified and directed by Engr-in-Charge.
Repairing of DC High Voltage Test Set Capacitiesup to 70 Kv for repairs, servicing comprising the following and refixing the same, re-orientation and labour for taking down the defective parts and refixing the same spare parts complete all as specified and directe
d by Engr-in-Charge. Opening the DC High Voltage Test Set for repair and replacement of the following items :- (a) Earth Leakage Relay With Core Balance Current Transformer (b) Push Button Switch Element Red color Make:Schneider (c) Tripping System for High voltage 10KV/30mA (d) High voltage copper single core lead with Armour (e) Silicon Carbide Schottky Diodes (f) Multi span sequential Timer digital type (g) Push Button Switch Element Green color. (h) ASPA DC array junction box DCDB 2 IN 1 OUT 500V (j) LT On / Off Toggle Switch Element. (k) High voltage test cable (l) Digital multi-function meter with LCD display (m) KV Meter digital type (n) Digital ammeter LED display 230volt,50Hz (o) Calibration of the System with Calibration machine for earth fault and over current fault complete testing (p) Top Cover
Repairing of DC Battery Charger of Capacities 24 Volt DC, servicing comprising the following and refixing the same, re-orientation and labour for taking down the defective parts and refixing the same spare parts complete all as specified and directed by Engr-in-Charge. Opening the DC 24 Vbattery Charger for repair and replacement of the following items:- (a) Volt meter and Ampere Meter (b) Wiring (c) Diode circuit (d) Relay (e) Control Transfomer (f) Rotary Switch
Labour and T & P for disconnection of LT panel of any size and Uplifting the same 0.45 Mtr from ground level including making PCC (1:3:6) work for foundation and excavation earth work for loop complete all as specified and directed by Engr-in-Charge.
Supplying and laying synthetic Rubber insulated mats 2 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and directed by Engr-in-Charge.
Material and Labour for repairing/ Plastering of Transformer platform of size 2.2mx2.2mx1 m height built in CM 1:4 including 20mm graded stone aggregate over the plinth along with provn of stair case on one side complete all as specified and directed by Engr-in-Charge.
Material and labour in replacment for installation, testing & commissioning of waterless and maintanance free Gel earthing (C C M compound), with BFC-50 kg jam fill compound along with 50 mm dia Cu bonded MS rod of length 3.00 Mtr below ground level including duly augering in ground pre cast or in situ cast in high purity electrically conductive granutar material having ultra low resistive value to acieve resistance below 2 Ohms connected with 25 mmx3mm Copper strip complete complete all as specified and directed by Engr-in-Charge.
Material and Labour Sticking of ready made sticker with letters,figures clearly mention, Name , SM No, in red colour of size for HT VCB , RMU, Step down transformer 0.6M x 0.2 M size complete all as specified and directed by Engr-in-Charge.
Material and Labour for cement painting of with prepared white ( snow sem ) for transformer plitnth area of any size all as specified for the following :- (including scrapping & cleaning with wire brush ) complete all as specified and directed by Engr-in-Charge.
Material and Labour for complete removal of Stone aggragerate and removing of sand mud. Debris/ weeds and plants from the agraggate and relaying at the removed place complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement battery 12V, DC, 100 AH maintnance free dry battery complete all as specified and directed by Engr-in-Charge.
All as per srl item No 52 here-in-before but size of 3.5 core, 70 sqmm.
All as per srl item No 52 here-in-before but size of 3.5 core, 50 sqmm.
All as per srl item No 52 here-in-before but size of 3.5 core, 35 sqmm.
All as per srl item No 52 here-in-before but size of 3.5 core, 25 sqmm.
All as per srl item No 52 here-in-before but size of 4 core, 16 sqmm.
All as per srl item No 52 here-in-before but size of 4 core, 10 sqmm.
Supply & fix in Replacement of Trivector meter three phase four wire TVM 110 Volt , 1 A/5A class 0.5 with CT complete all as specified and directed by Engr-in-Charge.
Supply, Laying, connecting, testing and commissioning in replacement ( including taking out existing cable) LT cable of PVC sheathed XLPE cable armoured aluminium conductor 1100 V graded after taking out/down old existing old vintage cables from trenches / ducts/ road crossing/wall and poles complete all as specified and directed by Engr-in-Charge of following size
Excavation in trenches in soft and loose soil n.exc 1.5 mtr wide and n.exc. 1.5 mtr depth for laying and taking out of electric power cable and getting out complete all as specified and directed by Engr-in-Charge.
Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed by Engr-in-Charge.
Removing excavated material not exceeding 50 mtr away and depositing where directed at a level n. exc 1.5 mtr above the starting point complete all as specified and directed by Engr-in-Charge.
Material and labour in replacement Retro Reflective installation sign boards of size 5 feet x 4 feet fabricated out of 16 gauge MS sheet frame duly welded/riveted with MS square pipe of size 25mm x25mm at height 2.00 meter above ground level on stainless steel heavy duty pipe of size 50mm bore embaded 60 CM in PCC 1:2:4 type B 1 block of size 45cmx45cmx60cm including necessary excavation and earth work .The steel portion of the board shall be painted in stove enameled paint and the front & back of the frame shall be overall sheathed with blue colour base painter adhesive tape. The wiriting matter will be in English language on both sides with reflective adhesive painter tapes complete all as specified and directed by Engr-in-Charge. Note: Sample Kept in the AGE Office
Material & labour for river washed and screened dry sand for filling under and above the under ground cable for cushioning of cables etc.complete all as specified and directed by engr –in-charge, Note : Measurement shall be taken after punning down complete all as specified and directed by Engr-in-Charge.
Laying only old LT cable cover obtained from excavation complete all as specified and directed by Engr-in-Charge.
Material and Labour for boring of holes under road/pavement/hard standing including material and labour for HDPE pipe of 80/100mm dia suitable for 04 Kg/cm working pressure. Wall thickness of pipe not less than 6.5 mm complete all as specified and directed by Engr-in-Charge.
Material and Labour in replacement for service cable 6 Sqmm 2 core 1100 volts grade heavy duty cable PVC insulated stranded alumn conductor, served with an inner sheathing of PVC tape and overall PVC sheathed in service connections/perimeter light supply as per site requirement, flat or circular complete all as specified and directed by Engr-in-Charge.
Material and labour for PCC 1:2:4 type B-1, (using 20 mm graded crushed stone aggregate) for Coping (Size: LxWxH-0.45Mx0.45Mx0.45M)etc complete all as specified and directed by Engr-in-Charge.
supply & installing in replacement old rusted /damage steel tubular swan neck swaged poles type 410 SP-31 (9 mtr long) of approx wt.147 kg conforming to IS 2713 (Part-II) including base plate,GI pipe for cable protection etc. complete all as per manufacturer's instructions and complete all as specified and directed by Engr-in-Charge. NOTE:- The steel pole shall be painted by bituminous paint total length inside and up to planting depth outside and remaining portion of pole painted with two coat of aluminum paint over a coat of red oxide complete all as specified and directed. Note 2. Excavation, eath work will measured and paid separately under relevant item.
Material and Labour for Cutting / pruning of tree branches along security light pole around 2 mtr radius of security light and removing from site including arrangement of T&P (Axe, rope & ladder etc) complete all as specified and directed by Engr-in-Charge.
Supplying and fixing in replacement MCB SPN 40 to 63 Amps,50 Hz,10 KA,240 Volts complete all as specified and directed by Engr-in-Charge.
Supplying and fixing in replacement MCB SP , 6 to 32 Amps,50 Hz,10 KA,240 Volts complete all as specified and directed by Engr-in-Charge.
Material and labour for painting to the both sides of fencing of the transformer/RMU by scraping the existing surface and applying a coat of synthetic enamel paint of the existing colour complete all as specified and directed by Engr-in-Charge..
Material and Labour for re-painting of LT Steel tubular poles of any sizes with apply of 2 coats of aluminum paint including rubbing with wire brush/emery paper & writing pole Nos in appropriate size of letters including making yellow and black strips upto height of 1.5 mtr above from ground level complete all as specified and directed by Engr-in-Charge.
All as per item No 24 above but from 400 KVA to 630 KVA complete all as specified and directed by Engr-in-Charge.
Supply drawing, connecting and testing of 3 core, 1.5 Sqmm PVC insulated and PVC round sheathed copper conductor (flexible ) industrial cable, 1100 Volts conforming to IS 694 in steel tubular poles from KIOSK box to street light fitting including providing suitable copper lugs complete all as specified and dir
Taking down carefully from poles/bldg defective street/flood light fitting of any size for repairs and refixing the same after replacing defective accessories like driver, & PVC insulated sheathed copper conductor etc. complete & testing to entire satisfaction of Engr-in-Charge. (Note : - (i) Accessories like driver suitable for LED light of specified size & PVC copper wire of different size shall be measured and paid separately (ii) Quoted rate deemed to be included all Machinery, ladder, Tools & Plants needed for the necessary repair work of street/flood light.
ected by Engr-in-Charge.
-diito- all as above but cap of 90 watt
-diito- all as above but cap of 120/125 watt
-diito- all as above but flood lights of cap 190/200 watt
Supply and fixing in replacement LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engr-in-Charge.
-diito- all as above but cap of 90 watt
-diito- all as above but cap of 120/125 watt
-diito- all as above but flood lights of cap 190/200 watt
Supply and fixing in replacement Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminum IP66 LED flood light suitable for high lighting architectural façade and general purpose lighting of capacity 200/210 Watt LED complete all as specified and directed by Engr-in-Charge.
-diito- all as above but cap of 90 watt
-diito- all as above but cap of 120/125 watt
-diito- all as above but flood lights of cap 190/200 watt
Supply only compact LED electronic driver suitable to operate on voltage 150 to 277 volt 50/60 Hz AC supply of cap 60 watts complete all as specified and directed by Engr-in-Charge.
-diito- all as above but cap of 90 watt
-diito- all as above but cap of 120/125 watt
-diito- all as above but flood lights of cap 190/200 watt
Supply only LED tempered glass suitable of cap 60 watts complete all as specified and directed by Engr-in-Charge.
Supply only compact LED blub set suitable to operate on voltage 150 to 277 volt 50/60 Hz AC supply of cap 60 watts complete all as specified and directed by Engr-in-Charge.
Supply only compact LED FMSPD suitable to operate on voltage 150 to 277 volt 50/60 Hz AC supply of cap 70 watts complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of contactor 3 Pole power contractor, 40 A Cap ML2 having 2 NO +2 NC contacts complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of contactor 3 Pole power contractor, 40 A Cap MX0 having 2 NO +2 NC contacts complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of MCB 3 pole , 32 Amps,50 Hz,415 Volts, 16 KA, with thermal magnetic release complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of Automatic Light Timer switch with Nature switch Cat No. SWADEEP-02EC12KW3P, infra ray sensor with pre sawn switching off timer, 4-8 hrs, of Maximum load capacity of 4KW per phase. Degree of protection conforms to IP 65 complete all as specified and directed by Engr-in-Charge.
Supply & fixing in replacement of quick sensor QS-301 water proof sensor 220V auto day/Night ON and OFF photo cell , LDR Sensor of capacity 6A for fixing in places of defective timers of street light control panels complete all as specified and directed by Engr-in-Charge.
Material and Labour for PCC 1:3:6 type B0 using 12.5 mm graded stone aggregate for of pole complete all as specified and directed by Engr-in-Charge.
Material and Labour for PCC 1:4:8 type D2 using 40 mm graded stone aggregate for pole foundation Bedding complete all as specified and directed by Engr-in-Charge.
Material and Labour Plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregates for pole foundation of pole complete all as specified and directed by Engr-in-Charge.
Material and Labour for disconnecting all electric LT Supply from timer panel of 15 mtr height High mast and lowering down the high mast light fitting set by using motor/manually for repair/replacement work and change the unsv/worn out parts after repair works completed check the serviceability of high mast and remove all dust/nest and greasing the rope/motor/gear assembly for proper functioning before raising up in the the original position complete all as specified and directed by Engr-in-Charge. Note: Quoted rate shall deemed to be included all Hydra Lifting Machinery vehicle ,Tools & Plants needed for the necessary repair work of Himast light.
Supply only 1.5 HP motor 3 Ph 440 volt 50 hz AC supply for operating the stainless steel rope through gear assembly all as specified and directed by Engineer-in-charge
Supply only gear assembly used for operating the stainless rope for lowering down the high mast fitting all as specified and directed by Engineer-in-charge
Supply only stainless steel rope 6mm dia complete all as specified and directed by Engr-in-Charge.
Taking out old rusted unserviceable LT panel Supply, installing, testing and commissioning in replacement outdoor type stainless steel (SS 316) cubical enclosure compartmentalized exterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc.The outer enclosure shall be made of 3.15 mm thick SS 316 sheet and inner compartment should be 2 mm. The fixing of double doors shall be on SS hinges with anti-theft provision (the door can’t be removed from enclosure without cutting enclosure). All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 316. Sliding handle and locking arrangement front and rear both side . Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. IP-55 class protection and mounted on channel 75 mm welded with panel of SS 316 with 04 Nos foundation bolt of size not less than 20mm dia and 300mm long. The enclosure shall have provision of cable alley . Cable entry from bottom side including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked, 1100 volts grade of appropriate size (but not less than 2.5 sqmm). (Location- New Ashiyana ) (a) Incoming :- (i) Incomer of the panel having MCCB 4 pole , 630 Amps,50 Hz,415 Volts, 50 KA with microprocessor release - 01 Nos along with sprader terminals , Digital Multifunction Meter (Accuracy class 0.5) with LCD display for measuring of current, voltage, power, power-factor, energy parameters, Total Harmonic Distortion and Maximum Demand Indication etc and shall have RS-485 port for communication on Modbus protocol – 01 No, CTs ratio 400/5 A, Class 1, ISI marked -01 sets of three, Indicating lamp- 01 set of three & Aluminium bus bar of rating 800 Amp, 4 pole , mounted on SMC insulator- set of four. (ii) Digital type Volt meter 0-500 volt - 01 Set (iii) Digital type Amp meter with CT's - 01 No (iv) Indicating Lamps : 01 set (b) Outgoing :- (i) MCCB 4 pole 415 V breaking cap 36 KA , current rating 160 Amps along with sprader terminals. - 06 Nos (ii) All incoming & outgoing feeders shall be connected by cable through suitable size of gland plate/glands. (iii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint (iv) Indicating Lamps R Y B , LED type01 set
Supply only D clamp including nut bolt and washers complete all as specified and directed by Engr-in-Charge.
All as per item No 93 above but of size 3.5 /4 core Cable Size 16 Sqmm to 25 Sqmm
All as per item No 93 above but of size 3.5 core Cable Size 35 Sqmm to 120 Sqmm
All as per item No 93 above but of size 3.5 core Cable Size 185 Sqmm to 240 Sqmm
All as per item No 93 above but of size 3.5 core Cable Size 300 Sqmm to 400 Sqmm
Supply only 6 Sqmm 5 Core flexible copper cable complete all as specified and directed by Engr-in-Charge.
Note : Contractor should procure and provide 50 % of the material as listed above within 15 days of the placing of work order and shall be verified by the Engr-in-charge.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.42 MB
BOQ_834621.xls
BOQ • 0.32 MB
TD80.pdf
Tender Documents • 1.28 MB
Amend80no1.pdf
PDF • 0.21 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .