Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹79,160.27Admitted-Fee/PreQual/Technical/Finance JAMMU KASHMIR HORTICULTURAL PRODUCE MARKETING PROCESSING CORPORATION JKHPMC LTD HORTICULTURE DEPARTMENT JAMMU KASHMIR GOVERNMENT OPPOSITE PRESENTATION CONVENT SCHOOL RAJBAGH J K190008 | SRINAGAR | JAMMU AND KASHMIR | 190008 | L1 | Admitted-Fee/PreQual/Technical/Finance | ||
| 2 | L2₹94,321.63+₹15,161.36 (19.2%)Admitted-Fee/PreQual/Technical/Finance | L2 | Admitted-Fee/PreQual/Technical/Finance | ||
| 3 | L3₹1.0 L+₹20,839.81 (26.3%)Admitted-Fee/PreQual/Technical/Finance | L3 | Admitted-Fee/PreQual/Technical/Finance | ||
| 4 | Not Admitted-Fee/PreQual/Technical/Finance | - | Not Admitted-Fee/PreQual/Technical/Finance Others-The registration certificate along with its latest renewal has neither been updated nor submitted. Further, the PAN Card, GSTIN and other requisite documents have also not been submitted. |
Tender Value
₹95,758
EMD Value
₹1,915
Closing Date
3 Aug 2026, 4:00 pmClosed
EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
RNB ELECTRIC DIVISION KASHMIR ENGINEERING COMPLEX RAJ BAGH
Construction of Boundary wall with Devri gate and Chowkidar Quarter at GDC Verinag B.W.O Electric work
2026_PWDJK_316150_1
NIT No.78//2026-27 Dt/15/07/2026
Open Tender
Electrical Works
Percentage
Verinag
Please refer Tender documents.
4 documents required · 4 mandatory
₹200
EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
₹1,915
7 Aug 2026
15 Jul 2026
4 Aug 2026
15 Jul 2026
3 Aug 2026
15 Jul 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Wiring for lighting points/fan points/ exhaust fan points/call bell points with 1.5 sq mm FRLS PVC insulated flexible stranded copper conductor wires in recessed or surface medium class PVC conduit, with 240V 6A modular switch , modular plate and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable, etc.as reqd.(Havells/Polycab/Anchor/Apar/ Finolex/KEI/RR or eq.) incl. cost of conduit. | 15 | No. | 1,189 | ₹17,835 |
| 2 | Wiring for light/power plug points (15/16A heating points) with 2x4 sq mm FRLS PVC insulated flexible stranded copper conductor wires in recessed or surface medium class PVC conduit along with 1x4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing, etc. as required. (Maximum two points shall be connected on one circuit).(Havells/ Polycab/ Anchor/Apar/ Finolex/KEI/RR or eq. ) incl. cost of conduit | 50 | Mtr. | 373 | ₹18,650 |
| 3 | Supplying and fixing of suitable size GI box with modular plate and modular cover in front on surface or in recess, including providing and fixing of 6 pin 15/16 A modular socket outlet and 15/16A modular switch, connections, etc. as required. (Havells/ SSK/ Anchor/ ABB/Schneider or equivalent) | - | No. | 659 | - |
| 4 | Supplying and fixing of suitable size GI box with modular plate and modular cover in front on surface or in recess, including providing and fixing of 3 pin 5/6 A modular socket outlet and 5/6A modular switch, connections, etc. as required. (Havells/ SSK/ Anchor/ ABB/Schneider or eq.) | - | No. | 545 | - |
| 5 | Supplying and fixing of modular sockets/ indicators/switches on existing modular plate and switch box , incl. connections, etc. as required. (Havells/ SSK/ Anchor/ ABB/Schneider or equivalent) | - | - | - | - |
| 6 | i.3 pin 5A - 10A socket. | 2 | No. | 136 | ₹272 |
| 7 | ii. indicator. | 2 | No. | 121 | ₹242 |
| 8 | Point wiring for 5A -10A socket out lets (computer points) with 2x2.5 sq mm (P+N)FRLS PVC insulated 660/1100volt grade flexible stranded copper conductor wires in recessed or surface conduiting system and earthing the point with 1 x 2.5 sq. mm single core copper wire (loop earthing),(Maximum two points shall be connected on
one circuit).(Havells/Apar/ Polycab/ Anchor/ Finolex/KEI/RR or eq.) incl. cost of conduit | 20 | Mtr. | 311 | ₹6,220 |
| 9 | Supply, installation, testing and commissioning of 10 Watt LED recessed/ mounted (round or square) Down lighters , minimum 100lm/w, average life 50000 hours, LM79 & LM80 test report should be from Govt. Approved NABL lab / Govt. Of India , Operating temperature -10`C to +45`C. The job includes replacement warranty of fixture if damaged/ burnt out what so ever reason for a period of two years reckoned from the date of successful commissioning/ handing over of site to the intending
department. (Havells/ Philips/ Crompton/ Jaguar/Wipro). | 10 | No. | 850 | ₹8,500 |
| 10 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, , ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, suitable long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.85, Air delivery minimum 215 CM/M, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. Atomberg/Orient/USHA /Havells /Crompton / OR OEMs/ firms holding ISO
9001 certification (Quality Management System) as directed by engineer incharge. | - | No. | 2,695 | - |
stage.html
html • 0.02 MB
finance_1029542.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.51 MB
BOQ_1029542.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .