| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹92.9 LAccepted-AOC | L1 | Accepted-AOC LOWEST QUOTED BIDDER | |
| 2 | L2₹1.1 Cr+₹13.1 L (13.6%)Rejected-Finance | L2 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER | |
| 3 | L3₹1.1 Cr+₹14.1 L (14.7%)Rejected-Finance | L3 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER | |
| 4 | L4₹1.1 Cr+₹14.8 L (15.4%)Rejected-Finance FLAT NO 101 2ND FLOOR RAGHAVENDRA RESIDENCY PLOT NO 1 2 3 SURVEY NO 27 PICKET SECUNDERABAD 500026 | HYDERABAD | TELANGANA | 500026 | L4 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER | |
| 5 | L5₹1.1 Cr+₹15.0 L (15.6%)Rejected-Finance | L5 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER |
Tender Value
₹1.4 Cr
EMD Value
₹2.2 L
Closing Date
21 Sept 2023, 6:00 pmClosed
CWE (AF) SECUNDERABAD
CWE (AF) SECUNDERABAD BOWENPALLY POST SECUNDERABAD 500011
SPECIAL REPAIRS TO OH ELECTRIC LINE BY CONVERSION TO UG ELECTRIC LINE FOR PERIMETER LIGHTS AT AFA HYDERABAD
2023_MES_615507_1
86723/E8
Open Tender
Civil Works - Others
Item Rate
180 days
GE AFA HYDERABAD
AS PER NIT
9 documents required · 9 mandatory
₹1,000
GE AFA HYDERABAD
₹2.2 L
Yes
10 Oct 2023
24 Aug 2023
23 Sept 2023
24 Aug 2023
21 Sept 2023
14 Sept 2023
24 Aug 2023 - 9 Sept 2023
Amount
Dismantling of Cross arms of M.S. channel or angle sections etc. complete from over head lines 11 KV HT any type any size complete all as specifed and as directed.
Dismantling of ACSR or AAC conductors from over head lines 11 KV HT any type any size complete all as specifed and as directed.
S&F cable route marker made up of PCC block (1:3:6) type. C-1 using 20mm graded stone aggregated of size 900 mm x 300mm x 100 mm thick (45 cm buried in ground) and properly painted colour as per approved by Enginer - in -charge (HT) and written both side with signed red colour paint (MES HT cable 11 KV ) on route marker / Indicator including necessary excavation, PCC and earth work complete all as specified and as directed.
M&L for Boring of holes under road, pavement hard standing by using trenchless technology using ultrasound technique and necessary machine to insert pipe of 100mm light grade GI pipes with all fittings such as bends, elbows, Tees, etc, for protection of cable complete including all plant & machinaries, alongwih Butt fusion welding machine with all accessories, T&P etc required complete all as specifed and as directed. Note :- Protection pipe will be measured and paid separately
S&F polymer type Switch air break gang operated HT 11 KV Volt grade triple pole with 9 insulators, 400 amps rating with drop out fuse assembly with fuse carrier, fuse element mounted on insulator and fitted on steel frame vertically operated mechanism from ground level consisting of operating rod of 25mm bore light grade GI pipe of suitable length worked from ground level and with locking arrangement flat iron clamp 50mm x 6mm including MS channel of suitable size and length for fixing GOD including bolts, nuts, and washers complete fixed on existing four pole structure including taking down old one complete all as specifed and as directed. Note :- Channel, cross arms, bracings etc shall be measured and paid separately.
Supply, laying, testing and commissioning XLPE HT cable , insulated, screended, PVC bedded, galvanised steel strip or wire armoured, electic power cable (heavy duty) with aluminium conductor, conforming to IS : 7098 (Part II), 11 KV "E" grade, ISI marked in drum, cross sectional area 95 Sqmm, 3 core laid in pipe/ducts/ trenches/ under floor/ under road/ poles etc complete all as specifed and as directed. Note :- (a) Excavation and earth work, sand cushion, PCC cover and protection pipe shall be measured and paid separately in respective items. (b) Contractor shall ensure to visit the site and workout the actual requirement of cable before placing of order as per the site requirement as approved by GE / EIC. (d) The unit rate quoted shall be inclusive of any straight through joints comes in the total length of cable. No extra payment shall be allowed for the straight through joints
M & L for Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 3 core 95 Sq mm XLPE (HT) KV cable complete all as specifed and as directed.
M & L for Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 3 core 95 Sq mm XLPE (HT) KV cable complete all as specifed and as directed.
Supply install testing and commissioning feeder pillar box of size 1200 mm x 1200 mm x 1000 mm, factory made outdoor pedestal type double door fabricated out of 3.15 mm thick CRCA sheet and angle iron 50x50x6 mm sloppy roof locking arrangement comprising 50 mm size Godrej brass pad lock with duplicate keys two earth terminal suitable cable gland plate for incoming and outgoing 11 KV HT cables and protection of joint grouting of feeder pillar box by providing 90 cm long angle iron of size 50 mm x 50 mm x 6 mm welded on all the four corners embedded in platform,duly fabricated in a CPRI approved. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally expoxy polyster powder coating of flint grey shade. The panel shall having aluminium bus bar three strips of minimum size 800mm x 75mm x 10 mm with DMC/SMC/FRP HT long insulator complete. Note :- (a) Joints shall be measured and paid separately under respective item of this schedule complete all as specified and as directed. (b) Busbars should be insulated with coloured heat shrinkable type PVC sleeves and should be mounted on 12 KV grade insulators complete all as specified and as directed.
M&L for earth continuity conductor galvanised iron strip 32 mm x 6 mm or main earthing lead fixed to wall with clamps or recess or croses or buried in ground or drawn in conduits/pipe or fixed to poles or any other indicated situation for loop earthing etc including taking down of old one complete all as specified and as directed.
M&L for earthing complete with Galvanised steel earth plate eletrode 600 mm x 600 mm x 6 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below GL) with top edge of earth plate not less than 1.5 Mtr below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filled in alternate layers and electrode connections by using Galvanised iron 32 x 6 mm strip connected by means of bolts, nuts, check nuts and washer of galvanised iron or steel, provision of 40mm dia GI pipe medium grade for protection of GI earth strip and 20mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) type C1 chamber of size 45cm X 45cm X 45cm including, MS funnel, wire mesh, 50 mm thick RCC 1:2:4 type B1 earth pit cover with 6 Nos, 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance n exc 50 mtr, provision of charcoal and salt complete, including taking down of old one all as shown in electrical plate No 3 of MES Schedule Part-I (2009) complete all as specified and as directed.
M&L for Cross arms, bracings, channels, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint including taking down old U/S cross arm complete all as specified and as directed.
M&L for lightening arrester expulsion type complete with all fittings transmission class, 11000 Volts , discharge capicity 65 Kilo Amps including taking down of old one complete all as specified and as directed.
M&L for anti climbing devices,spikes type fabricated out of MS bar (round,square and flat) including nuts, bolts, washer and welding in two halves made to shape suit the cross section of the pole complete, including taking down of old one complete all as specified and as directed.
M &L for Danger Notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and coventional skull and bones in signal red colour and fixed with MS Clamp, bolts and nut of approved size, for HT,25x20cm size, including taking down of old one complete all as specified and as directed.
M&L for loose filling with aggregate of gauge 40 mm of broken stone or boulders, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface of transformer and two pole / four pole structure complete all as specified and as directed.
M&L for stringing and fixing in position ACSR conductor in OH lines conductor (Rabbit) including binding with aluminium wire complete after removing the oxidised ACSR Conductor from insulators, complete all as specified and as directed.
M & L for light grade galvanized pipe ISI marked with all fitting ISI marked, laid in trenches, under road or fixing on wall/pole/ crossing nallah etc of bore 100 mm, including taking down of old one complete all as specified and as directed .
M&L of PVC Sleeve (Colur code: red,yellow and Blue)suitable for ACSR conductor/strip, Squirrel/Weasel/Rabbit type including removing of old one complete all as specified and as directed.
Supply, laying and testing cable LT XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25.0 sq mm 4 core, complete all as specified and as directed.
Supply, laying and testing cable LT XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16.0 sq mm 4 core, complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10.0 sq mm 4 core, complete all as specified and as directed.
S & F cable junction box 200 mm x 160 mm x 98 mm in size, made out of thermoplastic, having IP 65 protection for outdoor installation fixed with 4 way bakelite cable terminals including 03 Nos polymide gland with check nut (M-32-02 N0 & M- 25 -01 N0 ) fixed on poles with aluminium clamps of size 25 x 3, unts, bolts, washers etc., including taking out of old unserviceable cable junction box complete all as specified and as directed Make :- Cat No . K-9250 of HENSEL or equivalent in SPELSBERG / RITTAL.
Supply, laying and testing Cable flexible, PVC Insulated ,PVC Sheethed 1100 Volts grade with stranded copper conductor of size 1.5 sq mm 2core drawn through pipe complete all as specified and as directed.
S & Laying Low Density Poly Ethylene (LDPE) flexible pipe of size 40 mm dia and of pressure rating 6 Kg/cm² laid inside the P.C.C. coping of poles for easy bending and passing of cables including clamping in a proper way complete all as specified and as directed.
Excavation in trenches in any kind of soil not.exc 1.5 m wide and not. exc 1.5 m depth and getting out, including trimming the sides and forming bottom surface to required levels for laying cables complete all as specified and as directed.
M & L for Double Wall Corrugated (DWC) pipe ISI marked with all fitting ISI marked, laid in trenches, under road or fixing on wall / pole / crossing nallah etc of bore 90 / 76 mm, complete all as specified and as directed
M & L for Double Wall Corrugated (DWC) pipe ISI marked with all fitting ISI marked, laid in trenches, under road or fixing on wall/pole/ crossing nallah etc of bore 110 / 93 mm, complete all as specified and as directed
M&L for River dry sand cushioning to UG cables (8 cm deep before laying of cable and 15 cm deep over the cable) in trenches including punned thickness up to 18 cm and consolidation, complete all as specified and as directed. Note :- Punned thickness only will be considered for payment.
Returning, filling in trenches in any kind soil in layers not .exc. 25 cm after laying of cables including spreading, levelling, and well ramming complete all as specified and as directed.
Supplying and laying un-reinforced precast concrete cable covers, class HV Type I, flat, size 300 mm x 180 mm x 40 mm. laid in trenches for cable protection complete all as specified and as directed.
Removing surplus excavated material (soil) to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed
SANJEEV CONSTRUCTIONS
Sri Lakshmi Enterprises
L and S ENTERPRISES
Saiansh Associates
SHRI GANESH ENTERPRISES
RAVINDRA BROTHERS
Rajan Traders
SPAAN Infratech
SATISH AND CO
Dwarka Pershad Radhey Ramanlal
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .