Schedule () 01-ELECTRIFICATION WORKS (NOTE:-(1) THE UNIT RATE TO BE QUOTED SHOULD BE INCLUSIVE OF ALL TAXES AND GST APPLICABLE FROM TIME TO TIME. (2) GST RULES WILL APPLY FOR THE E-TENDER. (3) THE SUPPLY OF GOODS AND SERVICE WOULD BE SUBJECT TO GST ACT AND RULES APPLICABLE FROM TO TIME. (4) For materials of purchase value Rs.5 lakhs and above, inspection shall be done by third party i.e. M/s. RITES and all expenditure in connection with the inspection shall be borne by the tenderer/Contractor . For ISI marked products, if the order is placed on ISI certified manufacturers, the materials can be accepted on firm's WTC.6) Please 8506791.00 refer to clause number 9 in General instructions to tenderers attached in Documents Section regarding Site Engineer condition 7)All accessories and items required for successfull erection/installation ,testing,commissioning of all schedule items as per site conditions is covered under contractor's scope of work 8)All items required for all schedule items where wiring and cabling is to be terminated at both incoming ends for successful installation/erection, testing and commissioning commissioning is covered under contractors scope of work 9)The bidder should submit along with his offer valid Electrical Contractor License failing which offer will be summarily rejected Above/
ar Description:- Supply ,Installation, Testing and commissioning of loop in loop out box of size 170x170x105 mm and made up of SMC ( similar to Syntex catalogue reference No.GS-JB- 1414) and
6A,SP,MCB 'C' curve confirming to IS: 60947-2 or latest duly pre wired up to ceiling rose and provision of the same close to light fitting on platform shelter including wiring from junction box to light fitting by using 3 core 1.5 sq.mm multi stranded flexible copper cable complete including all fixing arrangements and other accessories required complete as per site conditions in a manner as directed by the section engineer in charge at site. Above/ Square
Foot ar CHENNAI DIVISION-ELECTRICAL/SOUTHERN RLY Description:- Supply Erection, Installation and testing of Single Sided Wall/Double Sided wall / hanging / floor / pole mounting type LED illuminated, Modular, Changeable Aluminium extruded profile signage / direction board in Full/Half/Semi Parabolic and Elliptical square and multi angle shape, with die moulded internal structural brackets (Nylon/SS) and aluminium extruded heat sink. Suitable size end cap PC/SS304 should be provided with provision of illuminated Logo. The display sheet shall be of unbreakable 040 translucent polycarbonate sheet of 2 mm thickness. The text / 02 graphics matter vision angle shall not be less than 160 degree and visibility not be less than 75%. The approved colour text and graphics shall be printed router cut on monomeric calendered vinyl of
shall be hanging, wall mounting, ceiling mounting, pole mounting or floor mounting and as per site requirement. The signage shall have the integral mounting arrangements with sturdy structural frame and ACP cladding on the back side of the signage to avoid rusting and entry of dust. The LED board shall have uniform illumination with 4-8 W / sq. ft and with brightness more than ambient light. Suitable size end cap of 1.5 mm thick SS 304 should be provided. The work should be executed as per the approved Detailed specifications (STANDARD SIGNAGES AT STATIONS ON INDIAN RAILWAYS -APRIL 2023) Note: The Deferred Payment Clause is applicable to the above scope of work, and the same is enclosed with the tender document. Above/
ar 03 Description:- Fabrication, Supply, Fixing of clamp for 30W LED 4 feet fitting , of suitable size GI Flat including all accessories required complete as per site conditions complete in a manner as directed by Section Engineer in charge at site. Above/
Description:- Providing of saw cutting in concrete pavement 200mm to 250mm depth including all men and materials under contractors scope of work Above/
PVC insulated unsheathed single copper conductor cables conforming to IS:694/1990 or latest duly along wires vide and from MCB DB to switch boards and switch boards to light and fan points or elsewhere in a manner as directed by Senior Section Engineer in charge at site. Above/
ar Description:- Supply of vertical, double door, MCCB distribution board conforming to IS: 8623 (latest), made out of powder coat finished 2 mm CRCA sheet steel, having short time withstand current 50 kA per second and complete with electrolyte copper bus bar / earth link / brass neutral bar / DIN rail / cable adopter Boxes etc. 1 No. of 63A, FP, 36kA, MCCB (confirming to IS: 13947 (part
fixed magnetic settings, Earth Fault, Shunt Release etc as incomer and (3 No's 16A +3 No's 32A),25 kA,FP MCCB's) (confirming to IS: 13947 (part II) or latest) with adjustable thermal settings, fixed magnetic settings as feeder control and 1 No. of multifunction meter as per the specification enclosed and with RS 485 port and suitable rated CT / PT, if required, complete and erection, testing and commissioning of the same including all cable termination at both Incoming and Outgoing sides complete and as per industrial practices , suitable Angle iron frame work and other accessories required complete in a manner as directed by Section Engineer in charge at site. Above/
ar Description:- Supply of sheet steel enclosed 100A, 30kA, FP, MCCB with adjustable thermal and
erection, testing and commissioning of the same onto wall, or elsewhere using suitable mounting arrangements including all cable terminations and all other works and items required complete as per site conditions and in a manner as directed by Section Engineer in charge at site. Note: Enclosure shall be suitable for termination of LTUG cable at top and bottom side Above/
ar Description:- Supply of sheet steel enclosed 63A, 30kA, FP, MCCB with adjustable thermal and
erection, testing and commissioning of the same onto wall, or elsewhere using suitable mounting arrangements including all cable terminations and all other works and items required complete as per site conditions and in a manner as directed by Section Engineer in charge at site. Note: Enclosure shall be suitable for termination of LTUG cable at top and bottom side CHENNAI DIVISION-ELECTRICAL/SOUTHERN RLY Above/
ar 09 Description:- Supply of 10A Modular switches conforming to IS: 3854/ 1997 or latest and provision of the same in switchboards or elsewhere in a manner as directed by Section Engineer-incharge at site. Above/
ar Description:- Supply, Installation, Testing and commissioning of 150W LED High Bay light fittings
industrial standards including supply connection from ceiling rose by using 3 core 1.5 sq. mm Fire retardant low smoke PVC insulated, PVC round sheathed copper [White/Ivory colour] conductor flexible chord complete in a manner as directed by Section Engineer in charge at site. Note: The Deferred Payment Clause is applicable to the above scope of work, and the same is enclosed with the tender document. Above/
IS/IEC:60947 or latest onto existing DB's or elsewhere including all wiring and cable termination works at both Incoming and outgoing sides complete in a manner as directed by Section Engineer in charge at site. Above/
IS/IEC:60947 or latest onto existing DB's or elsewhere including all wiring and cable termination works at both Incoming and outgoing sides complete in a manner as directed by Section Engineer in charge at site. Above/
ar Description:- Supply,of commissioning of 8 way TPN MCB DB conforming to IS:8623 or latest ,IK- 09 ,CRCA sheet enclosure ,RAL 9003,powder coated with 100A insulated phase bus bars ,neutral bars with shrouds,earth bars,sticking saddles,cement spill protector ,color coded interconnecting wire
FP MCB/Isolator /RCCB/RCBO as Incomer ,DP RCCB/RCBO as sub incomerand SP MCB's as outgoing b)MCCB Incomer ,DP RCCB/RCBO as sub incomer and SP MCB's as outgoings and erection,testing and commissioning of the same on to the wall using suitable angle iron frame work and including cutting/chipping and re-plastering and bringing back walls to original condition including painting the walls to original condition complete as per industrial practices in a manner as directed by Senior Section Engineer in charge at site. Above/
IS/IEC:60947 or latest onto existing DB's or elsewhere including all wiring and cable termination works at both Incoming and outgoing sides complete in a manner as directed by Section Engineer in charge at site. Above/
IS/IEC:60947 or latest onto existing DB's or elsewhere including all wiring and cable termination works at both Incoming and outgoing sides complete in a manner as directed by Section Engineer in charge at site. Above/
ar Description:- Supply of IP 30 rated -Metal door Enclosure conforming to IS:8623 or latest suitable for surface and flush mounting and available in CRCA sheet steel, RAL 9003,powder coated with
commissioning of the same including cutting/chipping and re-plastering and bringing back walls to original condition including painting the walls to original condition complete as per industrial practices in a manner as directed by Senior Section Engineer in charge at site. CHENNAI DIVISION-ELECTRICAL/SOUTHERN RLY Above/
IS/IEC:60947 or latest onto existing DB's or elsewhere including all wiring and cable termination works at both Incoming and outgoing sides complete in a manner as directed by Section Engineer in charge at site. Above/
IS/IEC:60947 or latest onto existing DB's or elsewhere including all wiring and cable termination works at both Incoming and outgoing sides complete in a manner as directed by Section Engineer in charge at site. Above/
ar Description:- Supply, Erection, Testing and commissioning of floor-mounted, powdercoated (RAL 7035) 19" rack (1000x600x300 mm) featuring lockable/removable side panels, two pairs of adjustable rails, a toughened glass perforated front door, and a space-saving 3-point locking split
provisions to preserve usable U-space, integrated with a high-load power assembly comprising three 3-phase 4-wire LCD energy meters (10-60A, 415V AC, Class 1.0 as per IS 13779 with battery backup), Nine No's of 100A bolted HRC fuses and carriers with High breaking capacity of 100kA confirming to IS 13703-2/IEC 60269-2, and triple neutral/earth links, inclusive of site preparation, alignment, electrical terminations, and load testing including all cabling and wiring terminations at both incoming and outgoing ends and using suitable fixing and mounting arrangements in a manner as directed by the section engineer in charge at site. Above/
ar Description:- Supply , Installation, Testing and commissioning of 6A , SP,MCB conforming to
suitable for surface and flush mounting and available in CRCA sheet steel, RAL 9003,powder coated with provision to mount MCB/Isolator/RCCB/RCBO and other modular devices and erection, testing and commissioning of the same using all fixing arrangements along with all incoming and outgoing cabling termination works complete as per directions of Section Engineer in charge at site. Above/
Description:- Design, Supply,Erection,Testing and commissioning of Facade Lighting as per Annexure attached in Documents section Above/
ar Description:- Supply of 4 core 95 sq. mm ISI Marked cross linked polyethylene [XLPE] insulated, PVC outer sheathed, armoured with galvanized round steel wire or steel strip cable with aluminium conductor suitable for rated voltage of 1100 volts grade and conforming to IS:7098 (pt-1)/1988 with amdt.1, 2, 3 (reaffirmed 2005) or latest and Laying/leading of the same in the excavated trench, cable tray, threading through pipe, clamping on walls terminating in as many ends using suitable
in charge at site. Note: Cable shall be supplied by the OEM or their authorized dealers duly producing dealership certificate. All Cables shall be accepted only with NABL/WTC test certificates. All NABL/WTC test certificates for cables must include the following details (i) Batch No/Drum No/Lot No/Serial No of the tested cable (ii) LOA/Agreement No as reference with railway mentioned as the consignee/customer. (iii) The WTC should be issued on the official letter head of the manufacturer (OEM).Additionally ,documents supporting the purchase of materials from an ISI certified manufacturer should be submitted along with the materials. Ref: PCEE/MAS Ltr no:E.252/1/8/Circular dtd 25-03-2025 Above/
ar CHENNAI DIVISION-ELECTRICAL/SOUTHERN RLY Description:- Supply of 4 core 70 sq. mm ISI Marked cross linked polyethylene [XLPE] insulated, PVC outer sheathed, armoured with galvanized round steel wire or steel strip cable with aluminium
amdt.1, 2, 3 (reaffirmed 2005) or latest and Laying/leading of the same in the excavated trench, cable tray, threading through pipe, clamping on walls terminating in as many ends using suitable single compression cable glands and sockets complete in a manner as directed by Section Engineer in charge at site. Note: Cable shall be supplied by the OEM or their authorized dealers duly producing dealership certificate. All Cables shall be accepted only with NABL/WTC test certificates. All NABL/WTC test certificates for cables must include the following details (i) Batch No/Drum No/Lot No/Serial No of the tested cable (ii) LOA/Agreement No as reference with railway mentioned as the consignee/customer. (iii) The WTC should be issued on the official letter head of the manufacturer (OEM).Additionally ,documents supporting the purchase of materials from an ISI certified manufacturer should be submitted along with the materials. Ref: PCEE/MAS Ltr no:E.252/1/8/Circular dtd 25-03-2025 Above/
ar Description:- Supply of 4 core 35 sq. mm ISI Marked cross linked polyethylene [XLPE] insulated, PVC outer sheathed, armoured with galvanized round steel wire or steel strip cable with aluminium conductor suitable for rated voltage of 1100 volts grade and conforming to IS:7098 (pt-1)/1988 with amdt.1, 2, 3 (reaffirmed 2005) or latest and Laying/leading of the same in the excavated trench, cable tray, threading through pipe, clamping on walls terminating in as many ends using suitable
in charge at site. Note: Cable shall be supplied by the OEM or their authorized dealers duly producing dealership certificate. All Cables shall be accepted only with NABL/WTC test certificates. All NABL/WTC test certificates for cables must include the following details (i) Batch No/Drum No/Lot No/Serial No of the tested cable (ii) LOA/Agreement No as reference with railway mentioned as the consignee/customer. (iii) The WTC should be issued on the official letter head of the manufacturer (OEM).Additionally ,documents supporting the purchase of materials from an ISI certified manufacturer should be submitted along with the materials. Ref: PCEE/MAS Ltr no:E.252/1/8/Circular dtd 25-03-2025 Above/
least 6m away from track centre within railway land by saw cutting/breaker as per site conditions to avoid any damage to nearby site complete in a manner as directed by the Section Engineer in charge at site. Above/
using 20mm graded blue metal complete in a manner as directed by the Section Engineer in charge at site. NOTE: i)Cement shall be Ordinary Portland Cement, 43 grade, conforming to IS: 456 or latest. ii)Proper compaction of cement concrete shall be ensured as per standard industrial practices. iii)The finished level should match with surface level properly Above/
way of cable trench, dumping at embankment site within railway land complete as per specification enclosed and in a manner as directed by the Section Engineer in charge at site. NOTE: The Section Engineer, in charge at site, will indicate the route of cable trench. Above/
ar 28 Description:- Re-filling of trench with excavated earth, ramming, consolidation and bringing back the surface to original condition complete in a manner as directed by the Section Engineer in charge at site. Above/
ar 29 CHENNAI DIVISION-ELECTRICAL/SOUTHERN RLY Description:- Supply of perforated cable trays of 300mm width X 50mm height made of 2.00mm thick hot dip galvanized Sheet steel complete with all accessories including coupler plate, supports fabricated using 40x40x6 mm MS angles for the longitudinal members and 40 x 6mm MS flats for the cross members and erection, testing and commissioning of the same duly supported from walls/ ceiling/roof purloins/structural steel works or elsewhere using intermediate supports by 40x6 mm MS flats complete in a manner as directed by Section Engineer-in-charge at site. Note:-The cable tray supports shall be applied with two coats of red oxide primer and painted with two coats of bright aluminium paint. Above/
ar Description:- Supply and provision of 5 feet long 2" dia "B" class GI pipe confirming to IS: 1239 P1/2004, P2/1992 or latest for protecting the vertical raise of cable at walls / stanchions / FOB /lamp
intervals complete including coping arrangement and for concealing in the floor area near MDB in a manner as directed by Section Engineer in charge at site. Note: i) The open end of GI pipes shall be filled with "M seal" sealing compound to prevent ingress of water. ii) 5 feet length of G.I pipe is taken as 1 No for unit purpose. Damage to floors, if any, made for burying the pipe shall also be re-done to bring back the surface to original condition. Above/
capping / PVC conduit, if required as per site conditions), with 2 runs of single core multistrand copper wire, PVC insulated unsheathed, LSHF / ZHFR, of size 1.5 sq.mm., along-with earth wire and modular switches,complete with all accessories, junction box, ceiling rose etc, as per specifications enclosed Above/
sq. mm PVC insulated and PVC sheathed multi stranded aluminium conductor cable duly by binding onto insulators of brackets (Drawing enclosed) to be provided at appropriate locations as per site conditions complete in a manner as directed by Section Engineer in charge at Site. Note: 5 runs of
ar Description:- Supply of 4 core 35 sq. mm ISI Marked cross linked polyethelene [XLPE] insulated, PVC outer sheathed, armoured with galvanized round steel wire or steel strip cable with aluminium conductor suitable for rated voltage of 1100 volts grade and conforming to IS:7098 (pt-1)/1988 with amdt.1, 2, 3 (reaffirmed 2005) or latest and Laying/leading of the same in the excavated trench, cable tray, threading through pipe, clamping on walls terminating in as many ends using suitable
in charge at site. Note: Cable shall be supplied by the OEM or their authorized dealers duly producing dealership certificate. All Cables shall be accepted only with NABL/WTC test certificates. All NABL/WTC test certificates for cables must include the following details (iv) Batch No/Drum No/Lot No/Serial No of the tested cable (v) LOA/Agreement No as reference with railway mentioned as the consignee/customer. (vi) The WTC should be issued on the official letter head of the manufacturer (OEM).Additionally ,documents supporting the purchase of materials from an ISI certified manufacturer should be submitted along with the materials. Ref: PCEE/MAS Ltr no:E.252/1/8/Circular dtd 25-03-2025 Above/
ar Description:- Supply and Concealing of 25mm dia rigid PVC conduits [IVORY colour] confirming to
accessories like Bends,Junction Boxes and other items required as per site conditions and including cutting/ chipping the wall/ceiling or elsewhere and making good the same including replastering and painting walls to original condition /clamped at regular intervals, not exceeding 500 mm in a manner as directed by Section Engineer in charge at site and as per specification for wiring/ rewiring enclosed. Above/
ar 35 CHENNAI DIVISION-ELECTRICAL/SOUTHERN RLY 35 Description:- Supply and drawing of inside mains using 2 runs of 6 sq. mm [from MCB DB to switch boards and from switch boards to switch boards or elsewhere] Fire Retardant Low Smoke PVC insulated unsheathed multistranded copper conductor cables of 1100V grade [conforming to IS:694/1990 or latest] duly inside the PVC conduit concealed/laid complete as per the specification enclosed and in a manner as directed by Section Engineer in charge at site. Note: - 2 runs of 6 sq. mm copper conductor are taken as 1m for quantity purpose. Above/
ar Description:- Supply and drawing of inside mains using 2 runs of 4 sq. mm [from MCB DB to switch
insulated unsheathed multistranded copper conductor cables of 1100V grade [conforming to IS:694/1990 or latest] duly inside the PVC conduit concealed/laid complete as per the specification enclosed and in a manner as directed by Section Engineer in charge at site. Note: - 2 runs of 4 sq. mm copper conductor are taken as 1m for quantity purpose. Above/
ar Description:- Supply and drawing of inside mains using 2 runs of 2.5 sq. mm [from MCB DB to
insulated unsheathed multistranded copper conductor cables of 1100V grade [conforming to IS:694/1990 or latest] duly inside the PVC conduit concealed/laid complete as per the specification enclosed and in a manner as directed by Section Engineer in charge at site. Note: - 2 runs of 2.5 sq. mm copper conductor are taken as 1m for quantity purpose. Above/
Online UPS similar to GEM Contract No: GEMC-511687725739407 attached along with this Tender . Warranty certificate and Authorized dealership certificates should be submitted along with the supply of the material. Above/
ar Description:- Design, Composition, Supply & Installation of "STATION NAME BOARD" for building facade, signage letters of Stainless Steel304 graded 18swg laser sheet cut fabricated letters for text: as per requirement &design, with 25mm lipping in 22swgStainless steel sheet 304,
White LED Modules of Samsung / Philips make in 0.72 watts, with requisite Power supply of Meanwel branded with 2 years warranty, along with Breaker and Legrand /L&T timer, to be mounted on Syntax junction box to be fixed near sign location; Power should be provided near sign locations; all wiring has to be concealed and should not be visible, all fixtures should be in Stainless Steel / aluminium, concealed behind the letters.Note: The Deferred Payment Clause is applicable to the above scope of work, and the same is enclosed with the tender document Above/
ar Description:- Supply of 4 core 25 sq. mm ISI Marked cross linked polyethelene [XLPE] insulated, PVC outer sheathed, armoured with galvanized round steel wire or steel strip cable with aluminium conductor suitable for rated voltage of 1100 volts grade and conforming to IS:7098 (pt-1)/1988 with amdt.1, 2, 3 (reaffirmed 2005) or latest and Laying/leading of the same in the excavated trench, cable tray, threading through pipe, clamping on walls terminating in as many ends using suitable
in charge at site. Note: Cable shall be supplied by the OEM or their authorized dealers duly producing dealership certificate. All Cables shall be accepted only with NABL/WTC test certificates. All NABL/WTC test certificates for cables must include the following details (vii)Batch No/Drum No/Lot No/Serial No of the tested cable (viii)LOA/Agreement No as reference with railway mentioned as the consignee/customer. (ix)The WTC should be issued on the official letter head of the manufacturer (OEM).Additionally ,documents supporting the purchase of materials from an ISI certified manufacturer should be submitted along with the materials. Ref: PCEE/MAS Ltr no:E.252/1/8/Circular dtd 25-03-2025 Above/
ar 41 CHENNAI DIVISION-ELECTRICAL/SOUTHERN RLY Description:- Supply and Laying of 63 mm dia ISI Marked High Density Polyethylene pipes of material grade PE-100 and with Pressure rating of 6.0 P.N conforming to IS: 4984 / 1995 or latest in the excavated trench, clamping on walls / Steel members of platform shelter or elsewhere using suitable GI fixing arrangements and couplers and other accessories required at appropriate locations as per site conditions so that cable can be easily inserted and removed wherever need arises complete in a manner as directed by Senior Section Engineer-in-charge at site.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Checklist.pdf
ATTACHMENT
FacadeAnnexure.pdf
ATTACHMENT
FacadeImages.pdf
ATTACHMENT
GCC2022.pdf
ATTACHMENT
GCCACS1.pdf
ATTACHMENT
GCCACS2.pdf
ATTACHMENT
GCCACS3.pdf
ATTACHMENT
IRSGCCACS4.pdf
ATTACHMENT
IRSGCCACS5.pdf
ATTACHMENT
IRSGCCACS6.pdf
ATTACHMENT
IRSGCCACS7.pdf
ATTACHMENT
IRSGCCACS8.pdf
ATTACHMENT
IRSGCCACS9.pdf
ATTACHMENT
IRSGCCACS10.pdf
ATTACHMENT
ImportantinstructionstoTenderers.pdf
ATTACHMENT
HighBayLightGemProductID.pdf
ATTACHMENT
LEDspecification-SELSpecPower2-2015.pdf
ATTACHMENT
LTSwitchboardSpecification.pdf
ATTACHMENT
MCBDrawing.pdf
ATTACHMENT
MFMSpec.pdf
ATTACHMENT
MSBracketsDiagram.pdf
ATTACHMENT
NEFTFORM.pdf
ATTACHMENT
Payment_clause_for_LED_luminaries_and_BLDC_fans.pdf
ATTACHMENT
PointWiringSpecificationDetailed.pdf
ATTACHMENT
SpecialNotesFacade.pdf
ATTACHMENT
SpecificationforlayingUndergroundcable.pdf
ATTACHMENT
specificationforwiringandrewiring.pdf
ATTACHMENT
Undertaking.pdf
ATTACHMENT
UPSGEMDocument.pdf
ATTACHMENT
Part1.pdf
ATTACHMENT
Part2_1.pdf
ATTACHMENT
Part3_1.pdf
ATTACHMENT
Part4.pdf
ATTACHMENT
SpecialconditionsofContract_1.pdf
ATTACHMENT
GeneralinstructionstoTenderers_2.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .