Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
₹22.7 L
EMD Value
₹22,710
Closing Date
2 Jul 2025, 12:00 pmClosed
SE EWCL
MVVNL, TIPE IV/3, TRANSMISSION STAF COLONY, DEVA ROAD, CHINHAT, Lucknow
Shifting of 33 KV Line Tribhuwan Khera Near Marhala Chauraha and 33 KV Line Tibhuvan Khera Near Poni Road at Distt Unnao Under Deposit Scheme
2025_MVVNL_1046270_1
07/EWCL/2025-26
Open Tender
Electrical Works
Item Wise
90 days
UNNAO
AS per PQR
2 documents required · 2 mandatory
₹3,540
SE EWCL
₹22,710
11 Jul 2025
6 Jun 2025
2 Jul 2025
6 Jun 2025
2 Jul 2025
6 Jun 2025
Amount
Safe loading carriage including unloading & proper stacking of following store materials from any Electy.Store of Lucknow Zone to work site/JE Dump Store.
ST/Joist Girder Pole 11 Mtr.
V-type cross arm 100x50x6 mm, MS Channel 9.6 Kg./mtr
Polymeric 11 KV Disc Insulator B&S. Type 70 KN.
Disc Fittings Dog/ Racoon 70 KN.
Polymeric 33KV Pin Insulator
M.S. Angle Iron 65x65x6mm, 4300 mm long 2/6/8 no. Bracing, with 4/12/16 clamps (5.8 kg./m)
M.S. Angle Iron 65x65x6, 3200mm long, 5.8 Kg/Mtr. for cable with clamp
Top channel 125X65mm, 3200 mm long (13.10 Kg./m) with clamp
Earthing complete
Single core PVC Cable 1x400 Sq.mm.
Complete Stay (GI Stay rod 20x1800 mm, Stay 7/8 SWG 10 Kg.)
33 KV XLPE Cable 3x300 sq.mm.
33 KV XLPE 3X300 sq.mmm C/J/Kit (Outdoor)
33 KV XLPE 3X300 sq.mmm C/J/Kit (S/Th.)
ACSR Dog Conductor
Erection of the following support through digging pits complete in all respect including cutting, making holes, fixing of all types of accessories as per RESSPO/REC drawing. (All type of clamps nut & bolt, washer to be provided by contractor.)
Providing & Fixing of Stone Pad (300x300x75 mm)
33 KV Single support of ST Pole 11mtr long.with X Arm, Pin insulator with all accessories as required.
33 KV Cable Exposer Double pole structure on S.T. Pole 11mtr long complete with Top Channel,bracing. & all other acessories as required
33 KV End Type Double pole structure on S.T. Pole 11mtr long complete with Top Channel,bracing.& all other acessories as required
Tri Pole structure on ST Pole 11mtr long complete with Top Channel,bracing.& all other acessories as required
Four Pole structure on ST Pole 11mtr long complete with Top Channel,bracing.& all other acessories as required
Concreting of supports with cement, concrete (CC will be of cement coarse sand & Stone Grit) Grouting will be done 0.268 Cu.mtr./per pole with 1/6 of the full length of the support in the CC 1:4:8 ratio and plinthing of supports upto 300mm above ground level as per RESPO/ RES. drawing including back filling and proper ramming.
Earthing of supports with Earth Electrode 2.5 mtr. length including excavation of pit and driving M.S. Rod upto proper depth and connecting the earth electrode with the help of 6 SWG G.I. Wire and earthing lugs. RESPO/ RES. drawing.Earthing of each section pole is also to be done. (All type of clamps nut & bolt, washer to be provided by contractor.)
Erection/fixing for 33 KV Stay set with stay wire 7/8 SWG and clamp as per RESSPO drawing including binding, clambing, clamping, tightening, and nozzeling etc. complete in all respect including its grouting in size 0.60x0.60x0.3 mtr. ratio 1:4:8 of cement, sand and concrete (CC will be of cement coarse sand & Stone Grit). (All type of clamps nut & bolt, washer to be provided by contractor.)
Laying, spreading, lifting, Stringing, jointing and final sagging of ACSR Dog Conductor in accordance with profiles and sag chart including binding, jumpering and fixing of all accessories in 3 nos. conductor in parallel with PG Clamp binding wire etc as requested for job.
Painting of following supports with one coat of red oxide primer and two coats of aluminum white paint of ISI mark and top danger portion of each support must be painted by providing two coat of Post Office Red Paint (1.5mtr upper portion of support.) Paint and material would be given by contractor to complete of job. (All materials to be provided by Contractor).
Single Pole of 11 M S.T.P
Cable Expouser Double Pole of 11 M S.T.P
End Type Double Pole of 11 M S.T.P
Tri Pole of 11 M S.T.P
Four Pole of 11 M S.T.P
Providing & Fixing of 33 KV SMC Danger board ( as per RESPO/REC)with Clamp & Nut Bolt
Providing & Fixing of 33 KV SMC Number Plate ( as per RESPO/REC) with Clamp & Nut Bolt
Providing & Fixing of G.I. Barbed wire (2 Kg./pole)
Drilling and Laying of 3x300 Sqmm 33 KV, XLPE insulated U/G Cable in HDPE Pipe size of 160 mm dia (Pipe to be laid by HDD method) single circuit below minimum 1.5 mtr. Depth from ground level. (All decentralised material including HDPE Pipe to be provided by contractor).
Laying of 33 KV 3x300 Sq.mm XLPE cable (Double CKT.) by excavation of trench in the ground of size 750mm wide, 1200mm deep along with required material sand (0.197 Cu.mtr.), 1st class bricks (26.25 nos./meter), stond pad (2.2 no of size 600x450x50mm). The inter axial spacing between two cable should be in between 0.32 m to 0.40 m (As per JE instruction) and back filling the trench by soil. Spare cable shall be left and buried in the trench in the shape of rings at both ends. Cable laying work includes unrolling, cutting, making ring and sealing both ends of the cable. (All decentralised materials to be provided by Contractor).
Hoisting of 33 KV 3X300 Sq. mm. XLPE cable on double pole including G.I. pipe of size 6" dia 3 M long and its jumpering complete with clamps, nuts and bolts. (All material include GI Pipe to be provided by contractor).
Cable Route Marker
High Pressure Testing
NHAI/Forest/PWD Underground crossing charges documentation and approval fee etc.
Dismentaling and Safe Carriage to Store of exisiting old 33 KV Overhead line having approx 39 poles and its conductor.
SINLESS ELECRICAL CO. PVT. LTD. (BID ID -5283977)
RAJ ENTERPRISES (BID ID -5277202)
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .