Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
1) Tenderer should attach self attested copy of PAN CARD and photo identification in support of their Identity. 2) The documents attached to the tender document should be clear and legible for evaluation of tenders. Proper care to be taken in this regard
A copy of document to be uploaded containing the following details: Name of the tenderer/ contractor, Validity of DSC, Complete address with pincode, Contact No.
Scanned copy of PAN card has to be enclosed
Scanned copy of TIN card has to be enclosed
A copy of NEFT form duly filled in the details as necessary along with a cancelled Cheque to be uploaded. (The tenderer/ contractor not having NEFT form may down load the empty NEFT form available in documents site)
Information/ certificates required as per Tender document for partnership deed, Article of association, MOU, JV AGREEMENT, Proprietary firm etc.
Self Attested copy of Experience Certificate of Previous Work Done -The bidder should submit documents related to completed/on-going similar service contracts during the last three previous financial years and the current financial year along with the details of payments received and percentage penalties imposed therein, to classify the completed/ on-going similar service contracts.
For materials of purchase value Rs.5 lakhs and above, inspection shall be done by third party i.e. M/s. RITES and all expenditure in connection with the inspection shall be borne by thetenderer/Contractor (5) For ISI marked products, if the order is placed on ISI certified manufacturers, the materials can be accepted on firm's WTC
Chennai Division-Electrical arrangements for various works as per (List of Works Enclosed)
ME-29-II-1105-2026~SR
ME-29-II-1105-2026
Open
Works - General
120 Days
Chennai, Tamil Nadu
₹0
₹77,800
21 Sept 2026
21 Sept 2026
28 Sept 2026
182 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 38,87,181 | ||
| — | — | — | Above/ 375435.00 Below/P | ||
| a)Excavation of Cable trench in all kinds ofsoils duly removing all obstructions in theway of cable trench, dumping atembankment site within railway landcomplete as per specificationenclosed and in a manner as directed bythe Section Engineer in charge at site.NOTE: The Section Engineer, in charge atsite, will indicate the route of cable trench.b)Re-filling of trench with excavated earth,ramming, consolidation and bringing backthe surface to original conditioncomplete in a manner as directed by theSection Engineer in charge at site. | — | 1545.00 | — | — | |
| — | — | — | Above/ 87450.00 Below/P | ||
| Demolishing plain cement concrete inplatform or elsewhere, disposal of materialatleast 6m away from track centre withinrailway land by saw cutting/breaker as persite conditions to avoid any damage tonearby site complete in a manner asdirected by the Section Engineer incharge at site. | — | 165.00 | — | — | |
| — | — | — | Above/ 936870.00 Below/P | ||
| Supply and provision of mass concrete forplatforms or elsewhere with 1:2:4 ratiousing 20mm graded blue metal completein a manner as directed by the SectionEngineer in chargeat site.NOTE: i)Cement shall be OrdinaryPortland Cement, 43 grade, conforming toIS: 456 or latest.ii)Proper compaction of cement concreteshall be ensured as per standard industrialpractices.iii)The finished level should match withsurface level properly | — | 165.00 | — | — | |
| — | — | — | Above/ 186975.00 Below/P | ||
| Excavation of cable trench 0.45m wide x1.2 m deep under railway tracks (fromformation levels).duly removing stoneballast, back filling of the excavated cabletrench(after laying of cable with HDPEpipe),ramming & consolidation properlyand providing back the removed stoneballasts complete in a manner as directedby Section Engineer incharge at site. | — | 135.00 | — | — | |
| — | — | — | Above/ 15600.00 Below/P | ||
| Laying/leading of 4 core 16 sq.mm LTUGAluminium cable in the excavated trench,Threading through pipe, clamping on wallsand terminating in as many ends usingsuitable single compression cable glands,lugs, sockets and other items requiredcomplete as per site conditions in a mannercomplete as directed by Section Engineerin charge at site.Note:- 4Cx16 sq.mm LTUG AluminiumCable alone will be supplieddepartmentally. | — | 650.00 | — | — | |
| — | — | — | Above/ 12000.00 Below/P | ||
| Laying/leading of 4 core 25 sq.mm LTUGAluminium cable in the excavated trench,threading through pipe, clamping on wallsand terminating in as many ends usingsuitable single compression cable glands,lugs , sockets and other items requiredcomplete as per site conditions in a mannercomplete as directed by Section Engineerin charge at site.Note: - 4Cx25 sq.mm LTUG AluminiumCable alone will be supplieddepartmentally. | — | 500.00 | — | — | |
| — | — | — | Above/ 15000.00 Below/P | ||
| Laying/leading of 4 core 35 sq.mm LTUGAluminium cable in the excavated trench,Threading through pipe, clamping on wallsand terminating in as many ends usingsuitable single compression cable glands,lugs, sockets and other items requiredcomplete as per site conditions in a mannercomplete as directed by Section Engineerin charge at site.Note:- 4Cx35 sq.mm LTUG AluminiumCable alone will be supplieddepartmentally. | — | 500.00 | — | — | |
| — | — | — | Above/ 15000.00 Below/P | ||
| Laying/leading of 4 core 50 sq.mm LTUGAluminium cable in the excavated trench,threading through pipe, clamping on wallsand terminating in as many ends usingsuitable single compression cable glands,lugs , sockets and other items requiredcomplete as per site conditions in a mannercomplete as directed by Section Engineerin charge at site.Note:- 4Cx50 sq.mm LTUG AluminiumCable alone will be supplieddepartmentally. | — | 500.00 | — | — | |
| — | — | — | Above/ 38500.00 Below/P | ||
| Laying/leading of 4 core 70 sq.mm LTUGAluminium cable in the excavated trench,threading through pipe, clamping on wallsand terminating in as many ends usingsuitable single compression cable glands,lugs , sockets and other items requiredcomplete as per site conditions in a mannercomplete as directed by Section Engineerin charge at site.Note:- 4Cx70 sq.mm LTUG AluminiumCable alone will be supplieddepartmentally. | — | 1100.00 | — | — | |
| — | — | — | Above/ 38250.00 Below/P | ||
| Laying/leading of 4 core 120 sq.mm LTUGAluminium cable in the excavated trench,threading through pipe, clamping on wallsand terminating in as many ends usingsuitable single compression cable glands,lugs , sockets and other items requiredcomplete as per site conditions in a mannercomplete as directed by Section Engineerin charge at site.Note:- 4Cx120 sq.mm LTUG AluminiumCable alone will be supplied departmentally | — | 750.00 | — | — | |
| — | — | — | Above/ 95400.00 Below/P | ||
| Laying/leading of 4 core 185 sq.mm LTUGAluminium cable in the excavated trench,threading through pipe, clamping on wallsand terminating in as many ends usingsuitable single compression cable glands,lugs , sockets and other items requiredcomplete as per site conditions in a mannercomplete as directed by Section Engineerin charge at site.Note:- 4Cx185 sq.mm LTUG AluminiumCable alone will be supplied departmentally | — | 1800.00 | — | — | |
| — | — | — | Above/ 127000.00 Below/P | ||
| Leading / Laying of 3 core 95sq. mm crosslinked polyethylene [XLPE] HTUG cable inthe excavated trench, threading throughpipe, clamping on walls or elsewherecomplete as per industrial standards and ina manner as directed by Senior SectionEngineer in charge at site.Note: HTUG cable alone will be supplieddepartmentally | — | 1000.00 | — | — | |
| — | — | — | Above/ 36400.00 Below/P | ||
| Laying of 50 mm dia High DensityPolyethylene pipes in the excavated trench,clamping on walls / Steel members ofplatform shelter or elsewhere using suitableGI fixing arrangements and couplers andother accessories required at appropriatelocations as per site conditions so thatcable can be easily inserted and removedwherever need arises complete in amanner as directed by Senior SectionEngineer-in-charge at site.Note: 50mm dia HDPE pipe alone will besupplied departmentally. | — | 1300.00 | — | — | |
| — | — | — | Above/ 42000.00 Below/P | ||
| Laying of 63 mm dia High DensityPolyethylene pipes in the excavated trench,clamping on walls / Steel members ofplatform shelter or elsewhere using suitableGI fixing arrangements and couplers andother accessories required at appropriatelocations as per site conditions so thatcable can be easily inserted and removedwherever need arises complete in amanner as directed by Senior SectionEngineer-in-charge at site.Note: 63mm dia HDPE pipe alone will besupplied departmentally. | — | 1400.00 | — | — | |
| — | — | — | Above/ 100450.00 Below/P | ||
| Laying of 110mm dia High DensityPolyethylene pipes in the excavated trench,clamping on walls / Steel members ofplatform shelter or elsewhere using suitableGI fixing arrangements and couplers andother accessories required at appropriatelocations as per site conditions so thatcable can be easily inserted and removedwherever need arises complete in amanner as directed by Senior SectionEngineer-in-charge at site.Note: 110mm dia HDPE pipe alone will besupplied departmentally. | — | 2450.00 | — | — | |
| — | — | — | Above/ 13310.00 Below/P | ||
| Supply, Installation, Testing andCommissioning of the LT Earthingarrangements duly by excavating/ auguringof earth pit in all kinds of soil/concretesurface or elsewhere, construction ofmasonry earth pit enclosure, provision ofcover etc, complete including supply /leading / laying / burying and concealing ofGI strip 32 X 6 mm along with proper sleevefrom earth electrode to proposed MDB /SDB or elsewhere and in a manner asdirected by Senior Section Engineer incharge at site.Note:1) Masonry earth pit enclosure and covershall be as per drawing numberEL/P/TYPE/1022. | — | 2.00 | — | — | |
| — | — | — | Above/ 31825.00 Below/P | ||
| Installation, Testing and Commissioning ofthe LT Earthing arrangements duly byexcavating/ auguring of earth pit in all kindsof soil/concrete surface or elsewhere,construction of masonry earth pitenclosure, provision of cover etc, completeincluding supply / leading / laying / buryingand concealing of GI strip 32 X 6 mm alongwith proper sleeve from earth electrode toproposed MDB / SDB or elsewhere and ina manner as directed by Senior SectionEngineer in charge at site.Note:1) Masonry earth pit enclosure and covershall be as per drawing numberEL/P/TYPE/1022.2) LT Earthing Electrode alone will besupplied Departmentally. | — | 25.00 | — | — | |
| — | — | — | Above/ 3900.00 Below/P | ||
| Drawing of inside mains using 2 runs of 1.5sq. mm [from MCB DB to switch boards andfrom switch boards to switch boards / orelsewhere] multistranded copper conductorcables duly inside the PVC conduitconcealed / laid vide item No. 29 belowcomplete as per the specification enclosedand in a manner as directed by SeniorSection Engineer in charge at site.Note: - 2 runs of 1.5 sq. mm copper cableare taken as 1m for quantity purposeand will be supplied Departmentally | — | 300.00 | — | — | |
| — | — | — | Above/ 1300.00 Below/P | ||
| Drawing of inside mains using 2 runs of 4sq. mm [from MCB DB to switch boards andfrom switch boards to switch boards / orelsewhere] multistranded copper conductorcables duly inside the PVC conduitconcealed / laid vide item No. 29 belowcomplete as per the specification enclosedand in a manner as directed by SeniorSection Engineer in charge at site.Note: - 2 runs of 4 sq. mm copper cableare taken as 1m for quantity purposeand will be supplied Departmentally | — | 100.00 | — | — | |
| — | — | — | Above/ 1300.00 Below/P | ||
| Drawing of inside mains using 2 runs of 2.5sq. mm [from MCB DB to switch boards andfrom switch boards to switch boards / orelsewhere] multistranded copper conductorcables duly inside the PVC conduitconcealed / laid vide item No. 29 belowcomplete as per the specification enclosedand in a manner as directed by SeniorSection Engineer in charge at site.Note: - 2 runs of 2.5 sq. mm copper cableare taken as 1m for quantity purposeand will be supplied Departmentally | — | 100.00 | — | — | |
| — | — | — | Above/ 42600.00 Below/P | ||
| a)Supply and Drawing of inside mainsusing 3 runs of 1.5 sq. mm [from MCB DBto switch boards and from switch boards toswitch boards / modular furniture orelsewhere] fire retardant Low smoke PVCinsulated unsheathed multi-strandedcopper conductor cables conforming toIS:694/1990 or latest duly inside the PVCconduit laid vide 21) b) below complete asper the specification enclosed and in amanner as directed by Senior SectionEngineer in charge at site.b) Supply and Concealing of 25mm dia rigidPVC conduits [IVORY colour] conformingto IS:9537 Part3(2021) or latest[ISImarked] with wall thickness not less than2mm along with Bends, Junction Boxesand other items required along withmanpower as per site conditions completeincluding cutting/ chipping the wall/ceilingor elsewhere and making good the sameincluding replastering and painting wall tooriginal condition /clamped at regularintervals, not exceeding 500 mm in amanner as directed by Section Engineer incharge at site as per industrial standardsand as per specification for wiring/ rewiringenclosed. [Approximate length of PVCconduit] Note 1: - 3 runs of 1.5 sq. mm copperconductor and 1 m of 25mm dia PVCconduit pipe are taken as 1m forquantity purposeNote 2: Bends,JunctionBoxes,Clamps,Screws and other itemsrequired for successful concealing of25mm dia PVC conduit pipe at fixedintervals ,site conditions and as perdirections of Section Engineer inchargeat site is covered under contractorsscope of work. | — | 300.00 | — | — | |
| — | — | — | Above/ 6800.00 Below/P | ||
| a)Supply and Drawing of inside mainsusing 2 runs of 2.5 sq. mm [from MCB DBto switch boards and from switch boards toswitch boards / modular furniture orelsewhere] fire retardant Low smoke PVCinsulated unsheathed multi-strandedcopper conductor cables conforming toIS:694/1990 or latest duly inside the PVCconduit laid vide 22) b) below complete asper the specification enclosed and in amanner as directed by Senior SectionEngineer in charge at site.b) Supply and Concealing of 25mm dia rigidPVC conduits [IVORY colour] conformingto IS:9537 Part3(2021) or latest[ISImarked] with wall thickness not less than2mm along with Bends, Junction Boxesand other items required along withmanpower as per site conditions completeincluding cutting/ chipping the wall/ceilingor elsewhere and making good the sameincluding replastering and painting wall tooriginal condition /clamped at regularintervals, not exceeding 500 mm in amanner as directed by Section Engineer incharge at site as per industrial standardsand as per specification for wiring/ rewiringenclosed. [Approximate length of PVCconduit] Note 1: - 2 runs of 2.5 sq. mm copperconductor and 1 m of 25mm dia PVCconduit pipe are taken as 1m forquantity purposeNote 2: Bends,JunctionBoxes,Clamps,Screws and other itemsrequired for successful concealing of25mm dia PVC conduit pipe at fixedintervals ,site conditions and as perdirections of Section Engineer inchargeat site is covered under contractorsscope of work. | — | 50.00 | — | — | |
| — | — | — | Above/ 8300.00 Below/P | ||
| a) Supply and Drawing of inside mainsusing 2 runs of 4 sq. mm [from MCB DB toswitch boards and from switch boards toswitch boards / modular furniture orelsewhere] fire retardant Low smoke PVCinsulated unsheathed multi-strandedcopper conductor cables conforming toIS:694/1990 or latest duly inside the PVCconduit laid vide 23) b) below complete asper the specification enclosed and in amanner as directed by Senior SectionEngineer in charge at site.b) Supply and Concealing of 25mm dia rigidPVC conduits [IVORY colour] conformingto IS:9537 Part3(2021) or latest[ISImarked] with wall thickness not less than2mm along with Bends, Junction Boxesand other items required along withmanpower as per site conditions completeincluding cutting/ chipping the wall/ceilingor elsewhere and making good the sameincluding replastering and painting wall tooriginal condition /clamped at regularintervals, not exceeding 500 mm in amanner as directed by Section Engineer incharge at site as per industrial standardsand as per specification for wiring/ rewiringenclosed. (Approximate length of PVCconduit) Note 1: - 2 runs of 4 sq. mmcopper conductor and 1 m of 25mm diaPVC conduit pipe are taken as 1m forquantity purposeNote 2: Bends,JunctionBoxes,Clamps,Screws and other itemsrequired for successful concealing of25mm dia PVC conduit pipe at fixedintervals ,site conditions and as perdirections of Section Engineer inchargeat site is covered under contractorsscope of work. | — | 50.00 | — | — | |
| — | — | — | Above/ 123300.00 Below/P | ||
| Supply and Drawing of inside mains using2 runs of 2.5 sq. mm [from MCB DB toswitch boards and from switch boards toswitch boards / modular furniture orelsewhere] fire retardant Low smoke PVCinsulated unsheathed multi-strandedcopper conductor cables conforming to IS:694/1990 or latest duly inside the PVCconduit concealed / laid Vide item No.28below complete as per the specificationenclosed and in a manner as directed bySenior Section Engineer in charge at site.Note: - 2 runs of 2.5 sq. mm copperconductor are taken as 1m for quantitypurpose | — | 1370.00 | — | — | |
| — | — | — | Above/ 39520.00 Below/P | ||
| Supply and Drawing of inside mains using2 runs of 4 sq. mm [from MCB DB to switchboards and from switch boards to switchboards / modular furniture or elsewhere]fire retardant Low smoke PVC insulatedunsheathed multi-stranded copperconductor cables conforming to IS:694/1990 or latest duly inside the PVCconduit concealed / laid Vide item No.28below complete as per the specificationenclosed and in a manner as directed bySenior Section Engineer in charge at site.Note: - 2 runs of 4 sq. mm copperconductor are taken as 1m for quantitypurpose | — | 380.00 | — | — | |
| — | — | — | Above/ 138060.00 Below/P | ||
| Supply and Drawing of inside mains using2 runs of 1.5 sq. mm [from MCB DB toswitch boards and from switch boards toswitch boards / modular furniture orelsewhere] fire retardant Low smoke PVCinsulated unsheathed multi-strandedcopper conductor cables conforming to IS:694/1990 or latest duly inside the PVCconduit concealed / laid Vide item No.28below complete as per the specificationenclosed and in a manner as directed bySenior Section Engineer in charge at site.Note: - 2 runs of 1.5 sq. mm copperconductor are taken as 1m for quantitypurpose | — | 2340.00 | — | — | |
| — | — | — | Above/ 63020.00 Below/P | ||
| Supply and Drawing of earth wire using 1.5sq.mm fire retardant Low smoke PVCinsulated [green colour] unsheathed singlecopper conductor cables cablesconforming to IS: 694/1990 or latest dulyalong wires vide item No.24,25 and 26above and from MCB DB to switch boardsand switch boards to light and fan points orelsewhere in a manner as directed bySenior Section Engineer in charge at site. | — | 2740.00 | — | — | |
| — | — | — | Above/ 7930.00 Below/P | ||
| Supply and Concealing of 25mm dia rigidPVC conduits [IVORY colour] conformingto IS:9537 Part3(2021) or latest[ISImarked] with wall thickness not less than2mm along with Bends, Junction Boxesand other items required along withmanpower as per site conditions completeincluding cutting/ chipping the wall/ceilingor elsewhere and making good the sameincluding replastering and painting wall tooriginal condition /clamped at regularintervals, not exceeding 500 mm in amanner as directed by Section Engineer incharge at site as per industrial standardsand as per specification for wiring/ rewiringenclosed. [Approximate length of PVCconduit] | — | 130.00 | — | — | |
| — | — | — | Above/ 5600.00 Below/P | ||
| Concealing of 25mm dia rigid PVC conduitsalong with all accessories and includingcutting/ chipping the wall/ceiling orelsewhere and making good the sameincluding replastering and painting wall tooriginal condition /clamped at regularintervals, not exceeding 500 mm in amanner as directed by Section Engineer incharge at site and as per specification forwiring/ rewiring enclosed. [Approximatelength of PVC conduit]Note:25mm dia PVC conduit pipe,Bends, Junction Boxes alone will besupplied Departmentally | — | 200.00 | — | — | |
| — | — | — | Above/ 3200.00 Below/P | ||
| Drawing of earth wire using 1.5 sq.mm PVCinsulated copper conductor cables dulyalong wires vide item No's 18,19, and 20above and light and fan points vide itemNo's 31,32 and 33 below or elsewherecomplete in a manner as directed by SeniorSection Engineer in charge atsite.Note: 1.5 sq.mm copper cable alone willbe supplied departmentally. | — | 400.00 | — | — | |
| — | — | — | Above/ 10250.00 Below/P | ||
| Wiring to light, fan, exhaust fan points[Short point i.e. length upto 3 mtr] by supplyand drawing of 2 runs of 1.5 sq. mm FireRetardant Low Smoke PVC insulatedcopper multi- stranded copper cables of1100 V grade [conforming to IS: 694/1990or latest] duly inside the PVC conduitconcealed vide item No. 29 abovecomplete with provision of 6A Modularswitch conforming to IS: 3854/2023 orlatest, 1 No. 3 plate ceiling rose conformingto IS: 371/1999 or latest and with allstandard accessories complete and in amanner as directed by Section Engineer incharge at site. | — | 50.00 | — | — | |
| — | — | — | Above/ 18180.00 Below/P | ||
| Wiring to light, fan, exhaust fan points[Medium point i.e. length between 3 to 6mtr] by supply and drawing of 2 runs of 1.5sq. mm Fire Retardant Low Smoke PVCinsulated copper multi- stranded coppercables of 1100 V grade [conforming to IS:694/1990 or latest] duly inside the PVCconduit concealed vide item No. 29 abovecomplete with provision of 6A Modularswitch conforming to IS: 3854/2023 orlatest, 1 No. 3 plate ceiling rose conformingto IS: 371/1999 or latest and with allstandard accessories complete and in amanner as directed by Section Engineer incharge at site. | — | 60.00 | — | — | |
| — | — | — | Above/ 8140.00 Below/P | ||
| Wiring to light, fan, exhaust fan points [Longpoint i.e. length between 6 to 9 mtr] bysupply and drawing of 2 runs of 1.5 sq. mmFire Retardant Low Smoke PVC insulatedcopper multi stranded copper cables of1100 V grade [conforming to IS: 694/1990or latest] duly inside the PVC conduitconcealed vide item No. 29 abovecomplete with provision of 6A Modularswitch conforming to IS: 3854/2023 orlatest, 1 No. 3 plate ceiling rose conformingto IS: 371/1999 or latest and with allstandard accessories complete and in amanner as directed by Section Engineer incharge at site | — | 20.00 | — | — | |
| — | — | — | Above/ 20150.00 Below/P | ||
| Wiring to light, fan, exhaust fan points[Medium point i.e. length between 3 to 6mtr] by supply and drawing of 3 runs of 1.5sq. mm Fire Retardant Low Smoke PVCinsulated copper multi- stranded coppercables of 1100 V grade [conforming to IS:694/1990 or latest] along with a) Supplyand Concealing of 25mm dia rigid PVCconduits [IVORY colour] conforming toIS:9537 Part3(2021) or latest[ISI marked]with wall thickness not less than 2mm alongwith Bends, Junction Boxes and otheritems required along with manpower as persite conditions complete including cutting/chipping the wall/ceiling or elsewhere andmaking good the same includingreplastering and painting wall to originalcondition /clamped at regular intervals, notexceeding 500 mm in a manner as directedby Section Engineer in charge at site as perindustrial standards and as perspecification for wiring/ rewiring enclosed.[Approximate length of PVC conduit] b) Supply and provision of 6 A Modulartype switch conforming to IS: 3854/1997 orlatest, c)Supply and provision of 1 No. 3plate ceiling rose conforming to IS:371/1999 or latest and with all standardaccessories complete required as per siteconditions and in a manner as directed bySection Engineer in charge at site. | — | 50.00 | — | — | |
| — | — | — | Above/ 43700.00 Below/P | ||
| Wiring to light, fan, exhaust fan points [Longpoint i.e. length between 6 to 9 mtr] bysupply and drawing of 3 runs of 1.5 sq. mmFire Retardant Low Smoke PVC insulatedcopper multi- stranded copper cables of1100 V grade [conforming to IS: 694/1990or latest] along with a) Supply andConcealing of 25mm dia rigid PVC conduits[IVORY colour] conforming to IS:9537Part3(2021) or latest[ISI marked] with wallthickness not less than 2mm along withBends, Junction Boxes and other itemsrequired along with manpower as per siteconditions complete including cutting/chipping the wall/ceiling or elsewhere andmaking good the same includingreplastering and painting wall to originalcondition /clamped at regular intervals, notexceeding 500 mm in a manner as directedby Section Engineer in charge at site as perindustrial standards and as perspecification for wiring/ rewiring enclosed.[Approximate length of PVC conduit]b) Supply and provision of 6 A Modulartype switch conforming to IS: 3854/1997 orlatest, c)Supply and provision of 1 No. 3plate ceiling rose conforming to IS:371/1999 or latest and with all standardaccessories complete required as per siteconditions and in a manner as directed bySection Engineer in charge at site. | — | 100.00 | — | — | |
| — | — | — | Above/ 4250.00 Below/P | ||
| Stringing of overhead mains beneathplatform shelters using 5 runs of 16 sq. mmPVC insulated and PVC sheathed multistranded aluminium conductor cable dulyby binding onto insulators of bracketsprovided vide item No. 37 Below completein a manner as directed by SectionEngineer in charge at Site. Note:1) 5 runs of 16 sq.mm cable are taken as1m for unit purpose and will beSupplied Departmentally2)The earth wire should be lugged atboth ends and has to be terminated ineach MS clamp through Nuts and Bolts | — | 250.00 | — | — | |
| — | — | — | Above/ 4000.00 Below/P | ||
| Provision of MS brackets, fabricated as persketch enclosed, for supporting OH wirebeneath platform shelters, mounted with 4Nos. of porcelain vertical reel /shackleinsulators and earth stud / bolt, finished with2 coats of red primer and 1 coat ofaluminium paint and complete with fixingarrangements as per drawing enclosed andin a manner as directed by SectionEngineer in charges at siteNote: MS Bracket alone will besupplied Departmentally | — | 50.00 | — | — | |
| — | — | — | Above/ 3024.00 Below/P | ||
| Installation ,Testing and commissioning ofmodular frame plate with matching coverplate including and suitable for 12 modules,switches, sockets, blank plates etc. dulyaccommodated onto suitable modularswitch board box complete and recessmounting/ concealing the same onto thewall using suitable fixing arrangementsincluding cutting/ chipping/ making recesson the wall or elsewhere including all wiringworks complete including replasteringpainting etc. complete and in a manner asdirected by Senior Section Engineer incharge at site.Note: -12 module Frame plate withmatching cover plate, switch, socketand Modular GI box alone will beSupplied Departmentally. | — | 16.00 | — | — | |
| — | — | — | Above/ 2232.00 Below/P | ||
| Installation ,Testing and commissioning ofmodular frame plate with matching coverplate including and suitable for 8 modules,switches, sockets, blank plates etc. dulyaccommodated onto suitable modularswitch board box complete and recessmounting/ concealing the same onto thewall using suitable fixing arrangementsincluding cutting/ chipping/ making recesson the wall or elsewhere including all wiringworks complete including replasteringpainting etc. complete and in a manner asdirected by Senior Section Engineer incharge at site.Note: -8 module Frame plate withmatching cover plate, switch, socketand Modular GI box alone will beSupplied Departmentally. | — | 12.00 | — | — | |
| — | — | — | Above/ 380.00 Below/P | ||
| Installation ,Testing and commissioning ofmodular frame plate with matching coverplate including and suitable for 3 modules,switches, sockets, blank plates etc. dulyaccommodated onto suitable modularswitch board box complete and recessmounting/ concealing the same onto thewall using suitable fixing arrangementsincluding cutting/ chipping/ making recesson the wall or elsewhere including all wiringworks complete including replasteringpainting etc. complete and in a manner asdirected by Senior Section Engineer incharge at site.Note: -3 module Frame plate withmatching cover plate, switch, socketand Modular GI box alone will beSupplied Departmentally. | — | 4.00 | — | — | |
| — | — | — | Above/ 7319.00 Below/P | ||
| Installation, Testing and commissioning oftime switch assembly comprising of: -a)1 No. timer switch with daily settingsimilar to L&T catalogue reference J648B1[FM1 Quartz].b)1 No. 3 pole 25A power contactorconforming to IS: 13947/P4/1993 or latest,c)1 No. 40A DP [MCB type] isolatorconforming to IS: 13947/P3/1993 or latest,d)1 No. Neutral link etc.e)1 No. Earth link etc.f) Suitable rated control fusesall duly pre-wired and mounted on anappropriate sized well-seasoned woodenplank of thickness not less than 12 mm andduly housed into and powder coat finishedenclosure of size not less than 300mm X450mm X 300mm and made of 2mm thickSheet Steel complete and provision of thesame onto the wall or elsewhere usingsuitable fixing arrangements complete andin a manner as directed by SectionEngineer in charge at site.Note: Timer switch, Power contactor,MCB, Neutral Link, Earth link, fuses,wooden box, Enclosures alone will besupplied Departmentally. | — | 13.00 | — | — | |
| — | — | — | Above/ 5550.00 Below/P | ||
| Installation, Testing and commissioning ofthe 300mm sweep BLDC Exhaust fan ontothe buildings or elsewhere using suitableclamping and fixing arrangement completeas per industrial practices including supplyconnection from ceiling rose by using 3core 1.5 sq. mm fire retardant Low smokePVC insulated, PVC round sheathedcopper [White / Ivory colour] conductorflexible pendant chord conforming toIS:694/1990 or latest complete as perindustrial standards and in a manner asdirected by Senior Section Engineer incharge at site.Note: 300mm sweep BLDC Exhaust fanalone will be supplied departmentally. | — | 30.00 | — | — | |
| — | — | — | Above/ 7106.00 Below/P | ||
| Installation, Testing and commissioning of1200mm sweep BLDC ceiling fan onto thebuildings or elsewhere using suitableclamping and fixing arrangement completeas per industrial practices including supplyconnection from ceiling rose by using 3core 1.5 sq. mm fire retardant Low smokePVC insulated, PVC round sheathedcopper [White / Ivory colour] conductorflexible pendant chord conforming toIS:694/1990 or latest complete as perindustrial standards and in a manner asdirected by Senior Section Engineer incharge at site.Note: 1200mm sweep BLDC Ceiling fanalone will be supplied departmentally. | — | 34.00 | — | — | |
| — | — | — | Above/ 15500.00 Below/P | ||
| Installation, Testing and commissioning of4 feet 20W LED light fitting Batten typesuitable to work on 240V single phase 50Hz AC with lamp and all standardaccessories using suitable mounting andfixing arrangement as per industrialpractices including supply connection fromceiling rose by using 3 core 1.5 sq. mm FireRetardant Low Smoke PVC insulated, PVCround sheathed copper [White/Ivory colour]conductor flexible pendant chordconforming to IS:694/1990 or latestcomplete as per industrial standards and ina manner as directed by Senior SectionEngineer in charge at site.Note: 4 feet LED 20W light fitting BattenType with lamp alone will be suppliedDepartmentally | — | 155.00 | — | — | |
| — | — | — | Above/ 5735.00 Below/P | ||
| Installation, Testing and commissioning ofthe 400mm sweep BLDC Wall Mountingfan onto the buildings or elsewhere usingsuitable clamping and fixing arrangementcomplete as per industrial practicesincluding supply connection from ceilingrose by using 3 core 1.5 sq. mm fireretardant Low smoke PVC insulated, PVCround sheathed copper [White / Ivorycolour] conductor flexible pendant chordconforming to IS:694/1990 or latestcomplete as per industrial standards and ina manner as directed by Senior SectionEngineer in charge at site.Note: 400mm sweep BLDC WallMounting fan alone will be supplieddepartmentally | — | 31.00 | — | — | |
| — | — | — | Above/ 57550.00 Below/P | ||
| Installation, Testing and commissioning of600mm sweep BLDC Air circulators ontowall / stanchion / rail post or elsewhereusing suitable clamping arrangement madeof 40mm X 6mm MS flat and MS plate ofsize of 300mm X 300mm X 6mm completein a manner as per standard industrialstandards and in a manner as directed bySection Engineer in charge at site.Note: 600mm sweep BLDC Aircirculators alone will be suppliedDepartmentally. | — | 50.00 | — | — | |
| — | — | — | Above/ 11430.00 Below/P | ||
| — | 15.00 | — | — | ||
| Testing and Incomer Cable adaptor box on to and re-plasteringand originalcondition complete ends complete and as charge atsite.Note: MCB | : - Installation, with40A/63A/100A,FP,RCBO/MCCB/RCCBas alongwith cutting/chipping to outgoing Engineer in | — | MCB DB's ofSP/DP/FP,MCB's iron frame work conditionincluding termination works manner as directedby box etc. alone | ||
| — | — | — | Above/ 1560.00 Below/P | ||
| Installation, Testing and commissioning of45 W LED street fittings using suitable GItubular mounting arm bent to act as tubularsupport for anchoring arrangement ontowalls including supply connection fromceiling rose/junction box or elsewhere byusing 3 core 1.5 sq. mm Fire retardant lowsmoke PVC insulated, PVC roundsheathed copper [White/Ivory colour]conductor flexible chord conforming toIS:694/1990 or latest as per industrialstandards in a manner as directed bySection Engineer in charge at site.Note: 45W LED street light fittings alonewill be supplied departmentally. | — | 10.00 | — | — | |
| — | — | — | Above/ 5800.00 Below/P | ||
| Installation, Testing and commissioning of80 W LED street fittings using suitable GItubular mounting arm bent to act as tubularsupport for anchoring arrangement ontowalls including supply connection fromceiling rose/junction box or elsewhere byusing 3 core 1.5 sq. mm Fire retardant lowsmoke PVC insulated, PVC roundsheathed copper [White/Ivory colour]conductor flexible chord conforming toIS:694/1990 or latest as per industrialstandards in a manner as directed bySection Engineer in charge at site.Note: 80W LED street light fittings alonewill be supplied departmentally. | — | 25.00 | — | — | |
| — | — | — | Above/ 5875.00 Below/P | ||
| Installation, Testing and commissioning of200W LED Flood light fittings using suitableGI tubular mounting arm bent to act astubular support for anchoring arrangementonto walls including supply connection fromceiling rose/junction box or elsewhere byusing 3 core 1.5 sq. mm Fire retardant lowsmoke PVC insulated ,PVC roundsheathed copper[White/Ivory colour]conductor flexible chord conforming toIS:694/1990 or latest as per industrialstandards in a manner as directed bySection Engineer in charge at site.Note: 200W LED Flood light fittingsalone will be supplied departmentally | — | 25.00 | — | — | |
| — | — | — | Above/ 13650.00 Below/P | ||
| Installation, Testing and commissioning of150W LED High bay light fittings usingsuitable GI tubular mounting arm bent to actas tubular support for anchoringarrangement onto walls including supplyconnection from ceiling rose/junction box orelsewhere by using 3 core 1.5 sq. mm Fireretardant low smoke PVC insulated ,PVCround sheathed copper[White/Ivory colour]conductor flexible chord conforming toIS:694/1990 or latest as per industrialstandards in a manner as directed bySection Engineer in charge at site.Note: 150W LED High bay light fittingsalone will be supplied departmentally | — | 30.00 | — | — | |
| — | — | — | Above/ 62.00 Below/P | ||
| Installation, Testing and commissioning of6A ,DP,MCB with Enclosure onto wall orelsewhere using suitable angle iron framework and mounting and fixingarrangements as per industrial standardsincluding all wiring and cable terminationworks at both Incoming and outgoing sidescomplete in a manner as directed bySection Engineer in charge at site.Note: 6A, DP, MCB with Enclosure alonewill be supplied Departmentally. | — | 2.00 | — | — | |
| — | — | — | Above/ 308.00 Below/P | ||
| Installation, Testing and commissioning of25A ,FP,MCB Type COS with Enclosureonto wall or elsewhere using suitable angleiron frame work and mounting and fixingarrangements as per industrial standardsincluding all wiring and cable terminationworks at both Incoming and outgoing sidescomplete in a manner as directed bySection Engineer in charge at site.Note: 25A, FP, MCB Type COS withEnclosure alone will be suppliedDepartmentally. | — | 4.00 | — | — | |
| — | — | — | Above/ 424.00 Below/P | ||
| Installation, Testing and commissioning of63A ,FP,MCCB with Enclosure onto wall orelsewhere using suitable angle iron framework and mounting and fixingarrangements as per industrial standardsincluding all wiring and cable terminationworks at both Incoming and outgoing sidescomplete in a manner as directed bySection Engineer in charge at site.Note: 63A, FP, MCCB with Enclosurealone will be supplied Departmentally. | — | 2.00 | — | — | |
| — | — | — | Above/ 24645.00 Below/P | ||
| Supply of sheet steel enclosed 125A, 30kA,FP, MCCB with adjustable thermal andfixed magnetic settings, shunt trip, rotaryhandle etc. conforming toIS:13947/P2/1993 or latest and erection,testing and commissioning of the sameonto wall, or elsewhere using suitablemountingarrangements including all cableterminations and all other works and itemsrequired complete as per site conditionsand in a manner as directed by SectionEngineer in charge at siteNote: Enclosure shall be suitable fortermination of LTUG cable at top andbottom side. | — | 3.00 | — | — | |
| — | — | — | Above/ 6948.00 Below/P | ||
| Erection, Testing and commissioning of 12way Floor Mounting Type MCCB DB with 2Nos of 250A, 36kA, FP, MCCB along with250A FP onload COS as Incomer and (6No's 125A,FP,+6 No's 63A),FP,MCCB's asoutgoing including all cable termination atboth Incoming and Outgoing sidescomplete and as per industrial practicescomplete in a manner as directed by SeniorSection Engineer in charge at site.Note: MCCB DB,COS ,MCCB alone willbe supplied Departmentally | — | 2.00 | — | — | |
| — | — | — | Above/ 10422.00 Below/P | ||
| Erection, Testing and commissioning of 8way Floor Mounting Type MCCB DB with 2Nos of 250A, 36kA, FP, MCCB along with250A FP onload COS as Incomer and (2No's 125A,FP,+4 No's 63A+2 Nos 32A),FP,MCCB's as outgoing including allcable termination at both Incoming andOutgoing sides complete and as perindustrial practices complete in a manneras directed by Senior Section Engineer incharge at site.Note: MCCB DB,COS,MCCB alone will besupplied Departmentally | — | 3.00 | — | — | |
| — | — | — | Above/ 38170.00 Below/P | ||
| Erection, testing and commissioning of300mm width x 50mm height made of 2mmthick hot dip galvanized Sheet steelcomplete with all accessories includingcoupler plate, supports fabricated MS flatsof sufficient thickness and same dulysupported from walls/ceiling/roofpurloins/steel members of platformshelter/Foot over Bridge or elsewhereusing intermediate supports of MS flatscomplete including carrying out all civilworks incidental toprovision/supporting/grouting of cable traysupports complete as per industrialstandards ,site conditions and in a manneras directed by Section Engineer-in-chargeat site.Note: 1)The cable tray supports shall beapplied with two coats of red oxide primerand finished with two coats of brightaluminium paint.2)CabIe tray alone will be suppliedDepartmentally | — | 110.00 | — | — | |
| — | — | — | Above/ 8100.00 Below/P | ||
| Supply and leading / connecting he earthelectrodes with MDB /Cubicle panel /Escalator or elsewhere using 32X 6 mm hotdip galvanized GI flat duly buried in ground/ floor, embedding in wall or elsewherecomplete in a manner as directed bySection Engineer in charge at site. | — | 30.00 | — | — | |
| — | — | — | Above/ 53040.00 Below/P | ||
| Supply, Installation, Testing andcommissioning of the 1200mm sweepBLDC Ceiling fan as per specificationenclosed onto the buildings ceiling wall orelsewhere using suitable clamping andfixing arrangement complete as perindustrial practices including supplyconnection from ceiling rose by using 3core 1.5 sq. mm fire retardant Low smokePVC insulated, PVC round sheathedcopper [White / Ivory colour] conductorflexible pendant chord conforming toIS:694/1990 or latest complete as perindustrial standards and in a manner asdirected by Senior Section Engineer incharge at site. | — | 16.00 | — | — | |
| — | — | — | Above/ 18300.00 Below/P | ||
| Supply, Installation, Testing andcommissioning of 400mm sweep BLDCWall Mounting fan similar to Superfanmake, Model No: Super Visiree with ontothe building walls or elsewhere usingsuitable clamping and fixing arrangementcomplete as per industrial practicescomplete in a manner complete as directedby Senior Section Engineer in charge atsite. | — | 4.00 | — | — | |
| — | — | — | Above/ 8729.00 Below/P | ||
| Supply, Installation, Testing andCommissioning including concealing workalong with metal clad plug and socket unitin sheet steel enclosure conforming to IS:8623/1993 or latest complete as perindustrial practices with 1 No. 20A, SP,MCB conforming to IS/IEC:60947 or latestonto the walls including cutting/chippingand replastering and bringing back walls tooriginal condition including painting in amanner as directed by section engineer incharge at site. | — | 7.00 | — | — | |
| — | — | — | Above/ 15120.00 Below/P | ||
| Supply of 6A modular switches conformingto IS: 3854/ 1997 or latest in a manner asdirected by Section Engineer-in-Charge atsite. | — | 630.00 | — | — | |
| — | — | — | Above/ 25754.00 Below/P | ||
| Supply of 6A, modular sockets conformingto IS: 1293/ 2005 or latest in a manner asdirected by Section Engineer-in-Charge atsite. | — | 326.00 | — | — | |
| — | — | — | Above/ 25852.00 Below/P | ||
| Supply, Installation, Testing andcommissioning of 12 way SPN MCB DBconforming to IS 8623-1 & 3 or latest ,IK-08protection available in CRCA sheet steel,RAL 9003,powder coated with 100Ainsulated phase bus-bar/neutral bar/s withshrouds/earth bars/stickingsaddles/cement spill protector/color-codedinterconnecting wire set/cable ties/blankingplates and circuit identification label alongwith 1 No's of 32A ,DP,MCB and 10 Nos of10A,SP,MCB's conforming toIS/IEC:60947 or latest as feeder controlsalong with Cable adaptor box on to the wallusing suitable angle iron frame work andincluding cutting/chipping and re- plasteringand bringing back walls to originalcondition including painting the walls tooriginal condition complete including allinternal wiring connections andterminations as per industrial practices in amanner as directed by Senior SectionEngineer in charge at site | — | 4.00 | — | — | |
| — | — | — | Above/ 52525.00 Below/P | ||
| Supply, Installation, Testing andcommissioning of 36W square type 2 feetx 2 feet Recess LED light fitting as perspecification enclosed suitable to work on240V single phase 50 Hz AC with lamp andall standard accessories using suitablemounting and fixing arrangementscomplete as per industrial practicesincluding supply connection from ceilingrose by using 3 core 1.5 sq. mm FireRetardant Low Smoke PVC insulated, PVCround sheathed copper [White/Ivory colour]conductor flexible pendant chordconforming to IS:694/1990 or latestcomplete as per industrial standards and ina manner as directed by Senior SectionEngineer in charge at site. | — | 25.00 | — | — | |
| — | — | — | Above/ 17960.00 Below/P | ||
| Supply, Installation, Testing andcommissioning of 400mm sweep BLDCPedestal fan similar to KUHL make, InspiraP1 model in a manner complete as directedby Senior Section Engineer in Charge atsite. | — | 4.00 | — | — | |
| — | — | — | Above/ 16572.00 Below/P | ||
| Supply of 63A, FP, MCB conforming toIS/IEC:60947 or latest along with IP 30rated - Metal door Enclosure conforming toIS:8623 or latest suitable for surface andflush mounting and available in CRCAsheet steel, RAL 9003,powder coated withand erection, testing and commissioning ofthe same using all fixing arrangementsalong with all incoming and outgoingcabling termination works complete as perdirections of Section Engineer in charge atsite. | — | 6.00 | — | — | |
| — | — | — | Above/ 26580.00 Below/P | ||
| Supply of 20A, DP, MCB conforming toIS/IEC:60947 or latest along with IP 30rated - Metal door Enclosure conforming toIS:8623 or latest suitable for surface andflush mounting and available in CRCAsheet steel, RAL 9003,powder coated withand erection, testing and commissioning ofthe same using all fixing arrangementsalong with all incoming and outgoingcabling termination works complete as perdirections of Section Engineer in charge atsite. | — | 20.00 | — | — | |
| — | — | — | Above/ 21840.00 Below/P | ||
| Supply, Installation, Testing andcommissioning of 15W Recess LED lightfitting as per specification enclosed suitableto work on 240V single phase 50 Hz ACwith lamp and all standard accessoriesusing suitable mounting and fixingarrangements complete as per industrialpractices including supply connection fromceiling rose by using 3 core 1.5 sq. mm FireRetardant Low Smoke PVC insulated, PVCround sheathed copper [White/Ivory colour]conductor flexible pendant chord in amanner as directed by Senior SectionEngineer in charge at site | — | 40.00 | — | — | |
| — | — | — | Above/ 4880.00 Below/P | ||
| Supply and installation of 3-module DMC(Dough Moulding Compound) switch boardbox with frame plate and cover plate,suitable for indoor installation, having amodule capacity of 1 row x 1 column x 3Mand minimum box dimensions of 100 mm x75 mm x 50 mm (L x W x H). The switchboard box shall be manufactured fromDMC with a minimum material thickness of2.5 mm and shall be provided with suitableearthing provision and knockout holes forcable entry on all sides. The box shall beprovided with threaded holes for fixing theframe plate, complete with NiCr- platedbrass or stainless-steel screws. The frameplate and cover plate shall be configured asA x B x C, where A represents the numberof rows, B represents the number ofopenings, and C represents the openingsize of 1M or 2M. The cover plate shall bemanufactured from electrical- gradepolycarbonate, in off-white colour, with amirror-finish surface, and shall be of clip-ontype with adequate snap-fit durability andinterchangeability. The switch board box,frame plate and cover plate shall beindelibly marked with the manufacturer'sname. The complete assembly shall besupplied as a ready-to-install unit,conforming to the specified technicalrequirements and suitable for indoorinstallation as directed by Section engineerin charge at site. | — | 20.00 | — | — | |
| — | — | — | Above/ 13760.00 Below/P | ||
| Supply and installation of 6-module DMC(Dough Moulding Compound) switch boardbox with frame plate and cover plate,suitable for indoor installation, having amodule capacity of 1 row x 3 columns x 2Mand minimum box dimensions of 210 mm x75 mm x 50 mm (L x W x H). The switchboard box shall be manufactured fromDMC with a minimum material thickness of2.5 mm and shall be complete with suitableearthing provision and knockout holes forcable entry on all sides. The box shall beprovided with threaded holes for frameplate fixing, supported with NiCr-platedbrass or stainless-steel screws. The frameplate and cover plate shall have aconfiguration of A x B x C, where Arepresents the number of rows, Brepresents the number of openings, and Crepresents the opening size of 1M or 2M.The cover plate shall be made of electricalgradepolycarbonate, in off-white colour,with a mirror-finish surface, and shall be ofclip-on type with adequate snap-fitdurability and interchangeability. Theswitch board box, frame plate and coverplate shall be indelibly marked with themanufacturer's name. The completeassembly shall be supplied as a ready-toinstallunit, conforming to all the abovetechnical requirements and suitable for theintended indoor application as directed bySection engineer in charge at site. | — | 40.00 | — | — | |
| — | — | — | Above/ 5508.00 Below/P | ||
| Supply and installation of 12 module DMC(Dough Moulding Compound) switch boardbox with frame plate and cover plate,suitable for indoor installation, with aminimum overall size of 210 mm x 135 mmx 50 mm (L x W x H) and moduleconfiguration of 2 rows x 6 columns x 2M.The switch board box shall bemanufactured from DMC with a minimummaterial thickness of 2.5 mm, and shall beprovided with suitable earthing provisionand knockout holes for cable entry on allsides. The box shall have threaded holesfor fixing the frame plate, complete withNiCr-plated brass or stainless-steel screws.The frame plate and cover plate shall beconfigured as A x B x C, where A denotesthe number of rows, B denotes the numberof openings, and C denotes the openingsize of 1M or 2M. The cover plate shall bemade of electrical-grade polycarbonate,finished in off-white colour with mirrorfinish, and shall be of clip-on type withadequate snap-fit durability andinterchangeability. The switch board box,frame plate and cover plate shall beindelibly marked with the manufacturer'sname. The complete assembly shall besupplied as a ready-to-install unit,conforming to the specified technicalrequirements and suitable for the intendedapplication as directed by Section engineerin charge at site. | — | 12.00 | — | — | |
| — | — | — | Above/ 4975.00 Below/P | ||
| Supply and fixing of suitable modular coverplate / front plate for 6-Module GI modularbox, complete with modular switch/socketmounting provisions, screws, accessoriesand all necessary hardware. The coverplate shall be of approved make,compatible with the GI modular box, ofgood quality, rigid and properly finished.The item shall include cutting/adjustment,alignment, fixing and making good theinstallation complete as required at site.Cover plate shall be suitable for standard 6-module modular accessories and shallcomply with relevant applicable ISstandards as directed by Section Engineerin charge at site | — | 25.00 | — | — | |
| — | — | — | Above/ 11258.00 Below/P | ||
| Supply of modular frame plate withmatching cover plate suitable for 8 modulesduly accommodated onto suitable modularswitch board box made of 1.2mm thick GISheet complete and recess mounting/concealing the same onto the wall usingsuitable fixing arrangements includingcutting/ chipping/ making recess on the wallor elsewhere and painting etc., completeincluding fixing ,testing and commissioningof Switches and sockets supplied vide ItemNo.63 and 64 Above in abovearrangements including all internal wiringconnections in a suitable manner asdirected by Section engineer in charge atsite.Note: - 1 No. 8 Module frame plate withmatching cover plate and 1 No. Modular GIbox are taken as 1 No for quantity purposeand should match with IS codes with latestamendments. | — | 26.00 | — | — | |
| — | — | — | Above/ 3445.00 Below/P | ||
| Supply of modular frame plate withmatching cover plate suitable for 4 modulesduly accommodated onto suitable modularswitch board box made of 1.2mm thick GISheet complete and recess mounting/concealing the same onto the wall usingsuitable fixing arrangements includingcutting/ chipping/ making recess on the wallor elsewhere and painting etc., completeincluding fixing ,testing and commissioningof Switches and sockets supplied vide ItemNo.63 and 64 above in abovearrangements including all internal wiringconnections in a suitable manner asdirected by Section engineer in charge atsite.Note: - 1 No. 4 Module frame plate withmatching cover plate and 1 No. Modular GIbox are taken as 1 No for quantity purposeand should match with IS codes with latestamendments. | — | 13.00 | — | — | |
| — | — | — | Above/ 3250.00 Below/P | ||
| Supply of modular frame plate withmatching cover plate suitable for 2 modulesduly accommodated onto suitable modularswitch board box made of 1.2mm thick GISheet complete and recess mounting/concealing the same onto the wall usingsuitable fixing arrangements includingcutting/ chipping/ making recess on the wallor elsewhere and painting etc., completeincluding fixing ,testing and commissioningof Switches and sockets supplied vide ItemNo.63 and 64 above in abovearrangements including all internal wiringconnections in a suitable manner asdirected by Section engineer in charge atsite.Note: - 1 No. 2 Module frame plate withmatching cover plate and 1 No. Modular GIbox are taken as 1 No for quantity purposeand should match with IS codes with latestamendments. | — | 13.00 | — | — | |
| — | — | — | Above/ 1495.00 Below/P | ||
| Supply of 10A Bell Push, 230V AC, 50 Hz,momentary type, suitable for flush/surfacemounting, complete with cover, terminals,fixing accessories and all necessarycomplete in a manner complete as per ISspecifications complete in a mannerdirected by Senior Section Engineer incharge at site. | — | 13.00 | — | — | |
| — | — | — | Above/ 793.00 Below/P | ||
| Installation, Testing and commissioning ofCall Bell similar to Gold Medal Make andModel No: Curve plus and suitable foroperation on 230 V, 50Hz, single-phase ACsupply using suitable arrangementincluding supply connection from ceilingrose by using 3 core 1.5 sq. mm Fireretardant Low Smoke PVC insulated, PVCround sheathed copper (White/Ivory colour)conductor flexible pendant chord in amanner as directed by Section Engineer incharge at site.Note: Call Bell alone will be suppliedDepartmentally | — | 13.00 | — | — | |
| — | — | — | Above/ 2392.00 Below/P | ||
| Supply of 32A, FP, MCB conforming toIS/IEC:60947 or latest along with IP 30rated - Metal door Enclosure conforming toIS:8623 or latest suitable for surface andflush mounting and available in CRCAsheet steel, RAL 9003,powder coated withand erection, testing and commissioning ofthe same using all fixing arrangementsalong with all incoming and outgoingcabling termination works complete as perdirections of Section Engineer in charge atsite. | — | 26.00 | — | — | |
| — | — | — | Above/ 35000.00 Below/P | ||
| Supply of 3 Core x 0.75 sq.mm flexiblependant cord wire, suitable for pendantlight fittings, comprising three flexiblestranded copper conductors, PVCinsulated and PVC overall sheathed, withsuitable identification of individual cores,conforming to IS 694:2010 (latestapplicable revision). The cable shall besuitable for the rated voltage and operatingconditions of the installation. The item shallinclude supply in standard packing,loading, transportation, unloading,handling, stacking and delivery at site,complete in all respects as directed by theEngineer-in-Charge. | — | 1000.00 | — | — | |
| — | — | — | Above/ 160000.00 Below/P | ||
| Supply of " V" trough made of reinforcedcement concrete as per the drawing&specification enclosed and laying of thesame in the excavated trench complete ina manner as per industrial standards asdirected by the Section Engineer In chargeat Site | — | 1000.00 | — | — | |
| — | — | — | Above/ 155520.00 Below/P | ||
| Supply and filling of course river sand inplinth, excavated trench or elsewhereIncluding watering, ramming ,consolidatingand dressing complete in a manner as perindustrial standards and in a mannerdirected by the section engineer in charge | — | 135.00 | — | — | |
| — | — | — | Above/ 16500.00 Below/P | ||
| Installation, testing and commissioning ofstraight through jointing kit of Heatshrinkable type suitable for 11kV [E] XLPEcable of size 3 core x 95 sq.mm Aluminumcable with complete accessories andjointing thereof suitable for voltage up to 22kV complete in a suitable manner as perindustrial standards and in a mannerdirected by Section Engineer in charge atsite.Note: Straight through Joint Kit alonewill be supplied Departmentally | — | 4.00 | — | — | |
| — | — | — | Above/ 8250.00 Below/P | ||
| Installation, testing and commissioning ofIndoor termination kit of Heat shrinkabletype suitable for 11kV [E] XLPE cable ofsize 3 Core x 95 sq.mm Aluminum cablewith complete accessories and jointingthereof suitable for voltage up to 22 kVcomplete in a suitable manner as perindustrial standards and in a mannerdirected by Section Engineer in charge atsite.Note: Indoor Termination kit alone willbe supplied Departmentally | — | 2.00 | — | — | |
| — | — | — | Above/ 39498.00 Below/P | ||
| Supply Installation, Testing andcommissioning of 4 Way TPN MCB DBconforming to IS:8623-1 & 3,IEC 61439-1 &3 ,IK-09 protection,available in CRCA sheetsteel,RAL 9003 ,powder coated,ready touse DB's,provided with insulated verticalphase bus-bars,neutral bars withshrouds,earth bars,stickingsaddles,cement spill protector,color-codedinterconnecting wire set,cablesties,blanking plates and circuit identificationlabels with 100A,FP,MCCB conforming toIS:/IEC 60947-2 or latest as Incomer alongwith combination of 3 No's of 32A TP MCB+3 No's of 16A SP MCB's as feedercontrols along with Cable adaptor box on tothe wall using suitable angle iron framework and including cutting/chipping and replasteringand bringing back walls tooriginal condition including painting thewalls to original condition completeincluding all wiring and cable terminationworks at both incoming and outgoing endscomplete and as per industrial practices ina manner as directed by Senior SectionEngineer in charge at site.Note: MCB's shall confirm to IS/IEC 60898or latest | — | 2.00 | — | — | |
| — | — | — | Above/ 34200.00 Below/P | ||
| Supply and Laying/Leading of 3 core 6 sq.mm PVC insulated copper conductor flatsubmersible cable on forming to IS 694:2010 or latest including water proofingterminations ,joints and connecting up topanels in a manner as directed by SectionEngineer in charge at site. | — | 200.00 | — | — | |
| — | — | — | Above/ 16500.00 Below/P | ||
| Supply and fixing of medium duty GI pipe of100 mm dia, conforming to IS.1239, part 1(2004), for cable leading complete asdirected by Section Engineer incharge atsite. | — | 15.00 | — | — | |
| — | — | — | Above/ 8050.00 Below/P | ||
| Supply of Manila ropes as per GeM Reference document attached | — | 50.00 | — | — | |
| — | — | — | Above/ 126880.00 Below/P | ||
| Supply, Erection, Testing andcommissioning of 7.5 HP submersiblehorizontal open well pump set to operate on3 phase 415V 50 Hz with discharge of 750LPM to 450 LPM at head 28 mtrs to 46mtrs, delivery size : 50 mm, confirming toIS: 14220 suitable for 200 dia OPEN WELLalong with DOL microprocessor basedstarter panel with dry run, over loadprotection, with single phase preventer Setcomplete with control panel suitable foroperation on three phase AC supply alongwith all accessories including fixing andmounting arrangements and other itemsrequired for successful commissioning ofpump complete as per site conditions andas per industrial standards in a manneras directed by Section engineer in chargeat site. | — | 4.00 | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TSQtybreakup.pdf
ATTACHMENT
Listofworks.pdf
ATTACHMENT
Manilaropespecification.pdf
ATTACHMENT
Technicaldocuments.pdf
ATTACHMENT
Technicaldrawings.pdf
ATTACHMENT
Checklistlessthan50Lakh.pdf
ATTACHMENT
GCCandACS1-12.pdf
ATTACHMENT
GeneralinstructionstoTenderers.pdf
ATTACHMENT
ImportantinstructionstoTenderers.pdf
ATTACHMENT
ModelformofBGbondwithinstructions.pdf
ATTACHMENT
NEFTFORM.pdf
ATTACHMENT
Payment_clause_for_LED_luminaries_and_BLDC_fansasper2026.pdf
ATTACHMENT
Special_conditions_of_Contract_Electrical.pdf
ATTACHMENT
StandardGuaranteecertificateformat.pdf
ATTACHMENT
Undertakings.pdf
ATTACHMENT
TenderschedulecostbreakupUWIDwise.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .