Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.9 LAccepted-AOC 106 DR LALIT BANERJEE SARANI GROUND FLOOR KOLKATA 700073 | KOLKATA | KOLKATA | WEST BENGAL | 700073 | L1 | Accepted-AOC AOC ISSUED | |
| 2 | L2₹4.0 L+₹13,620 (3.48%)Rejected-Finance SRINIKETAN ROAD BOLPUR BIRBHUM 731204 | BOLPUR | BIRBHUM | WEST BENGAL | 731204 | L2 | Rejected-Finance That the bid is not L1 | |
| 3 | L3₹4.1 L+₹16,040 (4.10%)Rejected-Finance 58 B T ROAD KOLKATA 700 002 | KOLKATA | KOLKATA | WEST BENGAL | 700002 | L3 | Rejected-Finance That the bid is not L1 |
Tender Value
₹4.3 L
EMD Value
₹8,500
Closing Date
15 Jul 2024, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE-II KNHED PWDte.
KIT Building Annex, 4thFloor,P-16, India Exch. Place Extn., Kolkata -700073
SITC of Concealed Split type AC machine in LINIAC UPS Room and allied rooms at 1st Floor, under Cobalt Building at Medical College and Hospital,Kolkata.---- AC Work.
2024_WBPWD_695423_1
WBPWD/EE-II/KNHED/NIQ-26/24-25
Open Tender
A/C ORG
Item Rate
15 days
Kolkata
Please refer Tender documents.
5 documents required · 5 mandatory
₹8,500
OFFICE OF THE EE KNHED PWDte.
29 Aug 2024
18 Jun 2024
18 Jul 2024
18 Jun 2024
15 Jul 2024
26 Jun 2024
24 Jun 2024
Amount
Part A :-E.I work Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Make: R.R Kable / Polycab / Havells/Glostar/KEI) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required. vide pg no E-14 item no. 1a a. 2 X 4 sqmm + 1 x 2.5 sqmm ( for AC starter, timer)
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. Vide pg no F-5 item no. 9 a. 4.0 sqmm
b. 2.5 sqmm
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Anchor Roma plus / Legrand-Myrius / Schneider-Zencelo/L & T -Entice/Wipro- NOWA/ABB Ivie), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. vide pg no E17/5a
Supply & fixing 250V control starter type OLP 30M, 22-32A range, starter with AC looad display (make-- ultratech/Electron) incl. S&F of 6 moduler switch board
Part B:- SITC of AC machine Dismentling charges for the above said 3 nos 2.0 / 1.5 TR concealed Split / NORMAL SPLIT AC. The Indoor (IDU) & Outdoor (ODU) as per direction & satisfaction of EIC and deliverd the dismentled items from site to depertmental store.
Supply & delivery 1.5 TR capacity, R407/410 concealed type Split Air Conditioner of rated cooling capacity of 18000 BTU/hr, with 1 No. Rotary compressor, 1 No. IDU of rated power supply - 230V - 1ph-50Hz, 1 No. ODU of rated power supply - 230V, 1ph, 50 Hz, Air-flow/per IDU :- 600cfm, (Make : Hitachi / O-General / Daikin )
Supply & delivery 2.0 TR capacity, R407/410 concealed type Split Air Conditioner of rated cooling capacity of 24000 BTU/hr, with 1 No. Rotary compressor, 1 No. IDU of rated power supply - 230V - 1ph-50Hz, 1 No. ODU of rated power supply - 230V, 1ph, 50 Hz, Air-flow/per IDU :- 800cfm, (Make : Hitachi / O-General / Daikin )
Erection, testing and commissioning charges for the above said 2.0 / 1.5 TR concealed Split / NORMAL SPLIT AC. The Indoor (IDU) & Outdoor (ODU) unit must be supported by structure made of 40 x 40 x 5 mm amgle and tie rod incl. necy. Painting & as per direction & satisfaction of EIC.
Copper Refrigeration pipe line for Liquid Line (1/4" OD with 0.6mm thick) with proper supports & brackets for 1.5/2TR Hi-wall Split AC, as directed by EIC. (Make: Ryoku/Uniflow/Totaline/Mandeep)
Copper Refrigeration pipe line for Suction Line (5/8" OD with 0.6mm thick) with proper supports & brackets for 1.5/2TR Hi-wall Split AC as directed by EIC. (Make: Ryoku/Uniflow/Totaline/Mandeep)
Supply & Fixing Pipe Insulation for Liquid Line (1/4" OD with 9 mm thick) with proper insulating incl. rapping/bube tape for 1.5/2TR concealed Split AC as directed by EIC. (Make: Accroflex/Supreme/Twiga)
Supply & Fixing Pipe Insulation for Suction Line (5/8" OD with 9 mm thick) with Proper insulating incl. rapping/bube tape for 1.5/2 Tr Hi Wall Split air Conditioner as directed by EIC. (make: Accroflex/Suprime)
Control Cabling from Condensing Unit to Control Panel 4 Core 2.5 sq. mm. Communication Cable 2TR Hi-wall Split AC, as directed by EIC. (Make: R.R Kable / Polycab / Havells/Glostar/KEI)
Supplying, fabrication & fixing safety cage for installation of outdoor unit of 1.5/2 TR concealed split AC incl. drilling 2 nos holes in each angle including cutting holes into the wall & grouting the same with cement concrete (1:1 ½ :3) etc. fabricated with 3 NOS M.S U - Channel having size of 75mm x 40mm x 40mm having thickness of 6mm length angle of 25 mm x 25 mm x 5 mm suitable length and flat (25X5mm) iron with necessary painting incl. shade arrangement with corogated PVC shade with proper clamping arrangement
Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. CPVC Pipes Class-1, SDR-11 of dia PWD Sch S&P P-29, Item no-1(a) 25mm
Charges for Scaffolding arrangement including lifting for outdoor & indoor units.
Cu Pipe Line Safety Grill Enclosure :: S & installation of rectangular type M.S frame of size 10’’ x 6’’ x10’’ of 25mm M.S flat with 02 no interconnections by 25" x 25" x 5" M.S.flat with 25x25x5mm M.S angle with suitable clamping arrangement as required. All angle are jointed by argon welding system. M.S bar gap at 2’’ distance. Whole structure are grouted on wall at each 18" gap with 3" M.S. flat leg splitted at end ( 4" bullet fastener are to be used where grouting will not be possible) and mending good the damage to original finish incl all necy. materials, tools and tackles incl charges of scaffolding and painting with 02 coat of Synthetic enamelled paint over 02 coat of R.O. primer (Asian/Shalimer/Berger) incl. welding, carriage and transportation.
(Rate should be quoted inclusive of all taxes & duties)
RAMKRISHNA ELECTRONICS
TRANSTECH
technical_1514312.pdf
PDF • 0.24 MB
techsummary_1514312.pdf
PDF • 0.24 MB
finance_1514312.pdf
PDF • 0.24 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_1514312.pdf
PDF • 0.42 MB
AOC.pdf
PDF • 0.44 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .