| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹80.7 LAccepted-AOC | ₹80.7 L | L1 | Accepted-AOC L1 BIDDER |
| 2 | Rejected-Technical | - | - | Rejected-Technical The bidder did not submit the work experience certificate and electrical contractor license as per NIT. |
| 3 | Rejected-Technical | - | - | Rejected-Technical The bidder did not possess valid electrical contractor license as per NIT. |
| 4 | Rejected-Technical | - | - | Rejected-Technical The bidder did not possess valid work experience as per NIT. |
Tender Value
₹75.2 L
EMD Value
₹94,000
Closing Date
9 Oct 2023, 11:00 amClosed
HOD TE n CM
CMPDI HQ RANCHI
Design Supply installation commissioning testing and comprehensive maintenance of Grid Connected Rooftop Solar Power Plant Solar trees and Net Metering at CMPDI HQ campus Ranchi
2023_CMPDI_289274_1
60 of 2023-24 dated 20.09.2023
Open Tender
Miscellaneous Works
Item Rate
2006 days
CMPDI HQ RANCHI
Please refer Tender documents.
6 documents required · 6 mandatory
₹94,000
16 Jan 2024
21 Sept 2023
10 Oct 2023
21 Sept 2023
9 Oct 2023
21 Sept 2023
21 Sept 2023 - 28 Sept 2023
Amount
Supply of equipments for 40.6 kWp (Approx.) micro-grid solar photo-voltaic power plant as per latest MNRE guidelines on roof top of Archive building (Approx. area 350 sqm.) consisting of mounting structure of galvanised M.S. angle, mono-crystalline SPV modules of capacity minimum 535 Wp to be connected in appropriate series-parallel combination to form a SPV array of desired output capacity, required inverter rating, DC copper cable of suitable size and rating, junction boxes with all other fitting & fixing, data aquisition, solar radiation and environment monitoring system, suitable protection system, feeding power to micro grid, arrangement of enegy meter for solar power generation, 1.1 kV 3 phase uni/bi-directional energy meter (as per requirement at site). NOTE: All equipments should comply with respective latest BIS as applicable (mentioned in NIT).
Supply of equipments for 27.8 kWp (Approx.) micro-grid solar photo-voltaic power plant as per latest MNRE guidelines on roof top of Shed of Rabindra Bhawan (Approx. area 175 sqm.) consisting of mounting structure of galvanised M.S. angle, mono-crystalline SPV modules of capacity minimum 535 Wp to be connected in appropriate series-parallel combination to form a SPV array of desired output capacity, required inverter rating, DC copper cable of suitable size and rating, junction boxes with all other fitting & fixing, data aquisition, solar radiation and environment monitoring system, suitable protection system, feeding power to micro grid, arrangement of enegy meter for solar power generation, 1.1 kV 3 phase uni/bi-directional energy meter (as per requirement at site). NOTE: All equipments should comply with respective latest BIS as applicable (mentioned in NIT).
Supply of equipments for 20.8 kWp (Approx.) micro-grid solar photo-voltaic power plant as per latest MNRE guidelines on roof top of SBI BUILDING (Approx. area 144 sqm.) consisting of mounting structure of galvanised M.S. angle, mono-crystalline SPV modules of capacity minimum 535 Wp to be connected in appropriate series-parallel combination to form a SPV array of desired output capacity, required inverter rating, DC copper cable of suitable size and rating, junction boxes with all other fitting & fixing, data aquisition, solar radiation and environment monitoring system, suitable protection system, feeding power to micro grid, arrangement of enegy meter for solar power generation, 1.1 kV 3 phase uni/bi-directional energy meter (as per requirement at site). NOTE: All equipments should comply with respective latest BIS as applicable (mentioned in NIT).
Supply of equipments for 5 kWp (Approx.) micro-grid solar photo-voltaic tree as per latest MNRE guidelines in front of CPEI BUILDING consisting of mounting structure of HDGI, mono-crystalline SPV modules of capacity minimum 535 Wp to be connected in appropriate series-parallel combination to form a SPV tree of desired output capacity, required inverter rating, DC copper cable of suitable size and rating, junction boxes with all other fitting & fixing, data aquisition, solar radiation and environment monitoring system, suitable protection system, feeding power to micro grid, arrangement of enegy meter for solar power generation, 1.1 kV 3 phase uni/bi-directional energy meter (as per requirement at site). NOTE: All equipments should comply with respective latest BIS as applicable (mentioned in NIT).
Supply of equipments for 10 kWp (Approx.) micro-grid solar photo-voltaic tree as per latest MNRE guidelines in front of OLD BUILDING consisting of mounting structure of HDGI, mono-crystalline SPV modules of capacity minimum 535 Wp to be connected in appropriate series-parallel combination to form a SPV tree of desired output capacity, required inverter rating, DC copper cable of suitable size and rating, junction boxes with all other fitting & fixing, data aquisition, solar radiation and environment monitoring system, suitable protection system, feeding power to micro grid, arrangement of enegy meter for solar power generation, 1.1 kV 3 phase uni/bi-directional energy meter (as per requirement at site). NOTE: All equipments should comply with respective latest BIS as applicable (mentioned in NIT).
Designing, Installation, commissioning, testing, trial run of all the necessary equipments (as mentioned in item no. 1-5) for micro-grid solar photo-voltaic power plant on roof top of (Archive building, shed of Rabindra Bhawan, SBI building) & solar trees ( in front of CPEI BUILDING and Old building) along with liaison & obtaining NOC/permission from local supply utility and other works or material required for successful commissioning of the system as per specification detailed in NIT document and in the drawing (for reference only). This will also include comprehensive maintenance of the plant including all of its equipments for 5 years.
Supply and installation of bi-directional HT net energy meter following all the safety rules and regulations applicable as per Indian Electricity Act-2003, CEA guidelines and JSERC net metering regulations.
Supplying and laying of 4 core, 1.1 KV 25 sqmm. Aluminium armoured cable as per site requirement.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .