Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹2.4 CrAccepted-AOC D NO 55 41 18 1 DOCTOR S COLONY SEETHAMMADHARA VISAKHAPATNAM PIN 530013 | VISAKHAPATANAM | ANDHRA PRADESH | 530013 | ₹2.4 Cr | L-1 | Accepted-AOC Being L-1 |
| 2 | L-2₹2.4 Cr+₹1.6 L (0.68%)Rejected-Finance SHOP NO 4 SUN STAR CHS LTD PLOT NO 309 SECTOR 21 NERUL EAST NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | ₹2.4 Cr+₹1.6 L (0.68%) | L-2 | Rejected-Finance Being L-2 |
| 3 | L-3₹2.4 Cr+₹1.9 L (0.81%)Rejected-Finance B 12 VISHAKARMA JYOTI SUBHASH LANE MALAD E MUMBAI 400097 | MUMBAI SUBURBAN | MAHARASHTRA | 400097 | ₹2.4 Cr+₹1.9 L (0.81%) | L-3 | Rejected-Finance Being L-3 |
| 4 | L-4₹2.4 Cr+₹4.4 L (1.85%)Rejected-Finance ATLANTIS A2 1501 PLOT NO 05 SECTOR 11 NEAR CLOUD 36 GHANSOLI NAVI MUMBAI 400 701 E 97 CWE SUBS BHANDUP | THANE | MAHARASHTRA | 400701 | ₹2.4 Cr+₹4.4 L (1.85%) | L-4 | Rejected-Finance Being L-4 |
| 5 | L-5₹2.5 Cr+₹9.1 L (3.80%)Rejected-Finance UNIT NO 7 MOUNT VIEW CO OP HOUSING SOCIETY LIMITED MUMBAI MANKHURD 400 088 | MUMBAI SUBURBAN | MAHARASHTRA | 400088 | ₹2.5 Cr+₹9.1 L (3.80%) | L-5 | Rejected-Finance Being L-5 |
Tender Value
₹3.5 Cr
EMD Value
₹4.3 L
Closing Date
7 Oct 2024, 6:00 pmClosed
CWE (SUBS) MUMBAI
Commander Works Engineer Subs NCHC Powai Bhandup Post Office Mumbai 400 078
ADDN / ALTN AND SPL REPAIRS TO DEFENCE CIVILIAN ACCOMMODATION AT NAD TROMBAY UNDER GE (NW) MANKHURD
2024_MES_670132_1
8874/E8
Open Tender
Civil Works
Item Rate
540 days
Mankhurd
Please refer Tender documents.
8 documents required · 8 mandatory
₹2,000
Yes
GE (NW) Mankhurd
₹4.3 L
Yes
14 Nov 2024
2 Sept 2024
10 Oct 2024
2 Sept 2024
7 Oct 2024
23 Sept 2024
Amount
SCHEDULE 'A' (B/R ITEMS) Taking down cement plaster on brick or stone walls, etc, including raking out joints, hacking for key, scrubbing down with water , etc complete all as specified and directed.
Demolition of brick work /stone boulders built in cement mortar including all quoins, arches, pillars etc complete all as specified and as directed.
M & L Brick work with sub class 'B' bricks straight or curved on plan exceeding 6 m mean radius built CM 1:4 complete all as specified and directed.
M&L for Ready mix plaster 10mm thick on faces of bricks or concrete surface including necessary scaffolding upto 18m height, including preparation of wall surfaces etc complete all as specified and directed.
M&L for Ready mix plaster 15mm thick on bricks or concrete surface including dubbing coat to match with existing with necessary scaffolding upto 18m height including preparation of wall surfaces etc complete all as specified and directed
Chipping, removing carefully loose/damaged concrete incl plastering (total thickness upto 60mm ) from RCC surfaces of columns, beams, chajjas, soffits of slabs etc by low impact Hammer/Breaker without damaging the structure & cleaning the surfaces with wire brush etc and disposal of debris out side MOD land, complete all as specified and directed. Note: Hard concrete shall not be removed by force.
M&L for cleaning existing reinforcement by sand blasting with suitable pump as directed by the GE and wire/ rotary wire brush to a shining bright finish, making the surfaces free from loose material, dirt etc complete and applying two coats of alkaline rust converting primer conforming to ASTM-B-117 of make. "Feovert" of "Krishna Conchem" OR "Roff Rust Cleaner' of 'Pidilite' OR 'Shali Rustoff' of 'STP Ltd', on rebars with time interval of 1 hr between the coats, complete all as specified and directed. (Note :- Mode of measurement: superficial area of concrete will be measured.)
M&L for Anticorrosive Treatment to Reinforcement Epoxy Zinc Primer of M/s. Dr. Fixit by application on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat. The application shall be done by brush after cleaning/wire brushing to the exposed steel surfaces, complete all as specified and directed . Note:- Mode of measurement: superficial area of concrete will be measured.
M&L for providing mild steel TMT bars in various structural RCC elements like column, beams and Slab etc. including cutting, bending, fixing the bars, tying with binding wires etc. complete all as specified and directed. Note: This item is applicable for additional bars required in the existing RCC structures.
M&L for Epoxy bond coat of Make Fosroc (NITOBOND-EP) OR EPOXY BONDING AGENT of Dr. Fixit OR equivalent of M/s. Krishna Conchem as approved by GE over exposed concrete surfaces prior to application of any type of mortar to ensure bond between old concrete & new concrete by brush application complete all as specified and directed.
M&L for building up the profile of structural members by using Polymer mortar HB of Dr Fixit, while the bonding agent is still tacking upto 20mm thickness including levelling, profiling etc complete all as specified and directed.
M&L for building up the profile of structural members by using Polymer mortar HB of Dr Fixit, while the bonding agent is still tacking upto 40mm thickness including levelling, profiling etc in two layers, each layer not exceeding 20mm, complete all as specified and directed.
M&L for casting & repairing of excessively damaged distressed RCC members (exceeding 60mm in thickness) with prebatched, prepacked, single component ready to use microconcrete from Fosroc (Renderoc RG) or equivalent of Dr. Fixit as approved by GE, at any level/ height and at any lead or lift as directed including prefabricated water tight formwork, centering, scaffolding, also including mixing , laying, levelling, finishing, curing etc as per manufacturer's specifications and all other relevant worksincl scaffolding upto 18 mtr height complete all as specified and directed.
M&L for leakage / seepage proof coating consisting of preparing the new/old surfaces of existing exterior walls, parapet walls, chajjas etc. and applying Primeseal primer of M/s Dr Fixit or equivalent chemical of M/s STP Ltd as approved by the GE or one coat of Chemstic PDE 600 elastomeric coating (and allowing to dry for 8hrs) under torch dry condition and subsequently applying two coats of water proofing decorative elastomeric coating system Raincoat of M/s Dr Fixit with DFT 100microns or Shalicryl 215 of M/s STP Ltd or Chemstic PDE 600 elastomeric coating (the surfaces after painting one coat shall be allowed to dry for 6 to 8hours before application of next coat) including necessary scaffolding etc complete all as per manufacturer instructions and all as specified & directed. Note: The aforesaid treatment shall be got executed by the contractor from the authorised applicator of the manufacturer(s) and also necessary authenticated documents on account of above shall be submitted by the contractor to the GE including entering triparty agreement with manufacturer with MES as one party regarding guaranteed warranty clauses.
M&L for prepration of newly plastered/concrete surface of wall and applying two coat of distemper oil emulsion on walls with one coat of primer and including 3mm thick putty applying complete all as specified and directed
M & L for preparing old decorated surfaces of wall (plastered or unplastered or previously white washed ) & applying one coat of white wash complete all as specified and directed.
M& L for preparation of old plastered surface of ceiling and applying one coat of white wash complete all as specified and directed
M& L for complete removal of existing treatment on surfaces of walls and applying two coats of oil bound distemper 3mm thick wall care putty for smooth finish including one coat of primer applying on walls for smooth finish complete all as specified & directed
Demolition of stone slabs and tiles laid bedded and pointed in any mortar of any description or thicknes in floors , aprons etc complete all as specified and directed.
M&L for coloured 300x600x7 to 8mm thick digital ceramic tiles on vertical surfaces such as skirting,dado etc, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match, over and including 10mm thick cement mortar backing coat in CM 1:4 etc, complete all as specified and directed.
M&L for Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick CM 1:6 screed bed for laying floor finishes complete all as specifed and directed.
M&L for Light Shade Vitrified Ceramic tiles 10 mm thick (square/ rectangular) of approved size, area of each tile not exceeding 0.36 Sqm in floors etc, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match, over and including 15mm thick cement mortar screed bed in CM 1:6 etc, complete all as specified and directed.
M&L for Light Shade 600x100x10mm thick size Vitrified Ceramic tiles, on vertical surfaces such as skirting etc, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match, over and including 10mm thick cement mortar backing coat in CM 1:4 etc, complete as specified and directed.
M&L for coloured Glazed ceramic tiles in vertical surface 350x 250x 6-7 mm/ 450X 350X 6-7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match as in skirting/dados including 10mm thick rendering in CM 1:4 as in backing coats of tiles finished the surfaces rough to receive tiles etc complete all as directed and specified.
M&L for Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade complete including 15 mm thick CM 1:6 screed bed for laying floor finishes complete all as specifed and directed..
M&L for PCC 1:3:6 type C2 (using 40mm graded stone aggregate) as in plinth protection 75mm thick, with expansion joints & top surface finished even and smooth without using extra cement etc complete all as specified and directed.
M&L for 18mm thick MDF board for Kitchen cabinet/cup board shutter/Partition/Shelves etc in required size at site made out of 18mm thick MDF board both side decorative lamination PVC sheet complete all required etc. The panels shall be fabricated using adhesive and secure as required. All edges shall be covered with 2mm thick edge bonding taps or 90⁰ edge bent finish as per manufacturers instructions.
Demolition of lime concrete or lean concrete from sunken floor including floor tiles, hacking of surfaces after cleaning with wire brush (floor and adjoining walls) and disposing off debris outside MOD land complete all as specified and directed.
M & L for filling of lean concrete 1:5:10 type E2 (using 40 mm graded stone aggregates ) in sunken portion, as per requirement complete all as specified and directed.
M&L for 55mm thick PCC 1:2:4, type-B1, using 20mm graded stone aggregate as in sub base of floors and for any other purpose in any location mixed with WPC @ 2% by weight of cement, complete all as specified and directed. Note: Supply only WPC will be measured and paid separately.
M & L for special treatment for sunken portion of WCs/Bath & toilet etc executed in following stages : Stage 1: Providing 15mm thick plaster in CM 1:3 mixed with water proofing chemical of Dr.Fixit or Shalicrete 'R' of STP Ltd in the proportion/quantity all as per manufacturer's instructions. State 2 : Primer-Mix Tarfelt LM of STP Ltd (diluted with water in ratio 1:1) @ 250 gms/sqm and apply the primer on the plastered surfaces. Stage 3 : Application of 1st coat of Tarfelt LM of STP Ltd (without dilution with water) @ 1Kg/Sqm by brush all as per manufactuer's instructions. Stage 4: Laying fyber glass cloth (weight not less than 50gram/ Sqm) over the 1st coat while the coated surface is still sticky. Stage 5: After 6 to 7 hours interval, apply second coat i.e. final coat of Tarfet LM of STP Ltd (without Dilution with water) @ 1kg/ Sqm by brush as per manufacturer's instructions. Stage 6: Providing 10mm thick protective plaster in CM 1:3 mixed with STP No. 1 @ 250ml/50 Kg cement all as per manufacturer's instructions. Stage 7: Carryout ponding test for 48 hours to ensure water tightness of repaired sunken portion. NOTES :(i) Mode of measurement: Actual area treated (floor and adjoining walls) will be measured and paid . (ii) The above treatment shall be got executed through applicator of manufacturer and necessary authenticated documents on account of above shall also be produced by the contractor.
Taking up or down steel water tubing and connections of size 15mm bore, complete all as specified and directed.
Taking up or down steel water tubing and connections of size 20mm bore, complete all as specified and directed.
Supply and fixing of 16 mm outer diameter CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings (including provision of special fittings i.e. brass elbow, brass tee, Male brass threaded adaptor, female brass threaded adaptor etc required for fixing of bib tap, stop valve with CPVC pipes) concealed in walls/ ceiling or laying in floors etc., also including cutting chases, grooves and making good the same in CM 1:3 after fixing of pipes / fittings, complete all as specified and directed.
Supply & fix 20mm bore GI tubing, medium grade with and including all fittings and fixed to walls and ceilings or laid in floors, complete all as specified and as directed.
Supply & fix 40mm bore GI tubing, medium grade with and including all fittings and fixed to walls and ceilings or laid in floors, including taking down and removal complete all as specified and as directed.
S&F in repairs PVC (SWR) floor trap, plain with grating including jointing with solvent cement 75mm dia out let including grating connecting jointing to waste pipe and taking out existing unserviceable traps by hacking out concrete joints and making good of surfaces complete all as specified and as directed .
S&F PVC connections 15mm size with PTMT nuts of length 600mm
S&F in repair towel rail 600mm long fixed with and including chromium plated brass screws and wooden/plastic cleats (Min wt 190 gms) complete all as specified and directed.
S&F in repairs high level/low level PVC flushing cistern with PVC flush pipe, brackets, and PVC connection complete of 10 Ltr capacity complete all as specified and directed.
S&F in repairs 15mm bore Bib taps, cast copper alloy with crutch or butterfly handle, screwed down screwed for iron pipe or for brass ferrule fancy type chromium plated complete all as specified and directed.
S&F in repairs 15mm bib taps two way cock, cast copper alloy with crutch or butterfly handle, screwed down screwed for iron pipe or for brass ferrule fancy type chromium plated.
S&F in repairs pillar taps 15 mm of cast copper alloy with capstan; head chromium plated screwed down with pressure with or without lettered hot or cold with long screwed shank and fly nuts, screwed for iron pipe& fixed complete all as specified
S&F in repairs stop cock 15mm cast copper alloy with crutch or butterflty handle, screwed down screwed for iron pipe or for brass chromium plated with fancy type shank and cup(concealed type) complete all as specified and directed.
S&F in repairs Grating doom 100mm dia of PTMT complete all as specified and directed.
S&F in repairs Swivel shower of PTMT any colour for fixing with 15mm pipe. (Minimum weight 40gms) ® Shower arm 15 mm size, 195mm long with bend of 45degree with flange of PTMT any colour. (Minimum weight150gms (minimum 125mm dia or 125mmx125mm square size).
S&F Health Faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 m long flexible tube and ABS wall hook including making connection and fixed in position complete in all as specified and directed .
S&F in repairs Wash basins, Vitreous China (flat back or angle back type), including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe flat back, size 580x450 mm excluding taps, waste, chain and plug and porcelain stopper but including brackets complete all as specified and directed.
S&F in repairs SS Soap dish, any type, fixed to plugs with chromium plated brass screws complete all as specified and directed.
S&F in repairs sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and waste; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed.
M&L 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over screed bed or bedding layer of mortar 15 mm in cement mortar 1:4set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade including dismantling of existing tiles completet all as specified and directed
M&Lfor Marble work 18 to 20mm thick of any any colour as directed (table rubbed and polished) in steps, jambs, pillars, windowcills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade over screed bed or bedding layer of mortar 15 mm in cement mortar 1:4set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade including dismantling of existing tiles all as specified and directed
M&L for 35 to 40 mm thick machine cut, prepolished cuddappa stone slab as in plateform for fixing oval shape wash hand basin(including cutting the slab to oval shape to accommodate the sink and WHB), pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of stone slab etc,also including moulding/rounding to edges of the slab, including dismantling of existing tile slab complete as specified and directed.
M&L Machine cut kota stone slab flooring 20-25mm thick as in flooring, treads, risers, landing etc over 15mm thick cement screed base CM 1;6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing including dismantling of existing floor complete all as directed.
For mirror polishing of kota stone under item No. 54.00 complete all as specified and directed.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from metal frame/aluminium frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones complete all as specified and directed.
Taking down carefully existing aluminium sliding window shutters, taking down of existing broken 4 mm thick plain sheet glass from aluminium sliding window shutters including existing rubber gasket complete, supply and fixing 4 mm thick plain sheet glass with and including provision of new rubber gasket and re-fixing the shutters in existing position, complete all as specified and directed.
Taking down carefully existing aluminium sliding window shutters, taking down of existing stainless steel wire mesh from aluminium sliding window shutters including existing rubber gasket complete, supply and fixing stainless steel wire mesh of dia 0.36 mm and average width of aperture 1.40 mm with and including provision of "U" clip, re-fixing the shutters in existing position, complete all as specified and directed.
Taking down carefully aluminium sliding window shutters from the frames or chowkhat and supply and fix New locking arrangement by replacing of old one and re-fixing the same shutters in existing position etc, complete all as specified and directed
S&F for 25 mm dia decorative/fancy type stainless steel curtain rod with brackets and knobs at both ends as per site requirement including taking down old existing pipes with accessories. Note: the cost of brackets and knobs is deemed to be including in the quoted rate. Nothing extra shall be paid on this account.
S&F in repair 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls or in floor including taking down existing any type complete all as specified and directed.
All as per item No. 63.00 above, but 75mm bore
S&F in repair Vitreous china squatting pan orrisa pattern of size 580 x 440mm with integral foot rest and 'P' or 'S' trap including lime concrete bedding, connecting flushing pipe and taking out old WC pan & lime concrete and unserviceable connections and making good for floor etc complete all as specified and as directed
S&F in repair Vitreous china Wash down water closet (Pedestal pattern), complete white (excluding fixing bolts, flushing cistern and flush pipe) and 'P' or 'S' trap including seat cover, long bend with bedding, connecting flushing pipe and taking out old WC pan & lime concrete and unserviceable connections and making good for floor etc complete all as specified and as directed
Removing plant/growth including its roots upto 1.00m of plant height at any location/at any storey and of any description and treating the surfaces with Acid (HCL) and making good surfaces with cement mortar 1:4, complete all as specified and directed.
S&F 110mm bore PVC (SWR) bends
S &F PVC (SWR) bends, 75 mm bore,
S &F PVC (SWR) junction single(single T), 110 mm bore, equal or unequal
S &F PVC (SWR) junction single(single T), 75 mm bore, equal or unequal
S &F PVC (SWR) branch piece,double( Singe Y) 75mm bore equal or unequal
S &F PVC (SWR) branch piece,double (single Y) 110 mm bore equal or unequal
Taking down chowkats or frame with shutters ( without taking off shutters from the frame ) exceeding 1.5 Sqm but not exc 4 Sqm each complete all as specified and directed.
Taking down chowkats or frame with shutters ( without taking off shutters from the frame ) not exc 1.5 Sqm each complete all as specified and directed.
S& F second class hard wood plain, solid straight chowkats and frame, wrought framed rebated on the solid, rounded or chamfered, put together with glue, pinned at joints including making good disturbed surfaces of wall complete all as specified and directed
Taking down and refixing of shutter in the same opening exc 1.00 sqm not exc 2.00 sqm each complete all as specified and as directed.
S&F Glazed and skeleton shutters, 35 mm thick of Second class hard wood open rebated and prepared to receive glass, gauge etc without sash bars) edges of framing plain chamfered or rounded, fitted with cut and mitred beads for securing glass, etc, sizes of members of shutters as specified in SSR Part-1, Section 8, Clause 8.24(a) including rat tail door spring one for each shutter complete all as specified and as directed.
S&F stainless steel wire cloth 0.36mm nominal dial of wire and average width of aperture 1.40mm for fixing to wooden door/ window shutters in any position with new beads/ steel section as required for securing including dismantling of old jalli and painting to match with existing complete all as specified and as directed.
S&F Factory made Plain framed, panelled shutters, 35 mm thick of second class hard wood (Hollock) (any numbers of panels) with panels of 12 mm thick veneered particle board exterior grade medium density with commercial veneering on both faces with sheesham wood beading all round the panel made out of 20 by 15 mm , on one side and fitted to chowkhats complete all as specified and as directed.
S&F solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with Square tube, supply and fixing in opening as per specification given under SSR Part II 2010 including making good the disturbed surface all as specified and directed. Make: SYNTEX/SHALIMAR/RAJSHRI
M&L for factory made solid PVC panel type PVC door shutter 30mm thick consisting of frame made out of MS tubes for top and bottom rails MS frame shall be covered with moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rails, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading and jointed together with solvent supplying and fixing in the frame at site as per specifications and drawing given under SSR Part II 2020 complete all as specified and directed. Make : SYNTEX/SHALIMAR/RAJSHRI
S&F 100 mm long stainless steel butt hinges fixed with stainless steel screw complete all as specified and directed.
S&F aluminium anodised barrel tower bolts of extruded section of size 150 mm length complete all as specified and directed.
S&F aluminium anodised barrel tower bolts of extruded section of size 200 mm length complete all as specified and directed.
S&F 150 mm extruded aluminium alloy handles, fabricated type anodised complete all as specified and directed.
S&F aluminium anodised sliding door, bolts with hasp and staple ( bolt type ) and fixing clip of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy, length of bolts 250 mm complete all as specified and directed.
M&L PCC (1:2:4) type B1 using 20 mm graded stone aggregate as in hold fast, bed plate, coping, surface chanels etc including necessary form work complete all as specified and as directed.
M& L for preparation surfaces of new or previously untreated wood based surfaces of any description not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M& L for preparation old surfaces of wood of any description over 10 cm width or girth and applying One coat of synthetic enamel paint complete all as specified and directed.
Demolition of brick/cement concrete (unreinforced) / pcc tiles from existing roof/terrace etc and also removing/taking down of existing water proofing treatment of any thickness in any position including cleaning the surfaces of roof etc with wire brush complete and removing the retreived debris out side MD land complete all as specified and directed.
M&L cement plaster (1:3) with 10 mm thick to be finished smooth without using extra cement mixed with WPC @ 2% by weight of cement, complete all as specified and directed. Note : WPC shall be measured and paid separately as supply only.
M & L for APP modified roof treatment over existing roof slab etc including taking down to be executed through approved authorised applicator of the membrane manufacturer with the following specifications complete all as specified and directed:- (a) Applying oil bound bitumen primer @ 0.40 litre/ Sqm manufactured by the same manufacturer as that of APP with a density 0.87-0.89 Kg per litre at 25 degree centigrade on the prepared dry surface. (b) Laying APP modified water proofing membrane reinforced with non woven polyester fibre weight not less than 160gm/Sqcm using butane torch by torch application with 10cm side lap and 15cm end lap. (c) Physical properties of membrane shall be as under:- (i) Membrane weight not less than 3.50 Kg/Sqm. (ii) Non woven polyester weight not less than 160gm /sqm. (iii) Softening point of membrane not less than 150 degree Celsius. (iv) Joint tensile strength-longitudinal not less than 650N/Sqcm and transverse not less than 450 N/Sq cm (v) Tear strength-longitudinal not less than 300 N & transverse not less than 250 N. (vi) Elongation : > 20% in both directions. (vii) Impermeability/water tightness at 2 Kgf/cm2. (viii) Water absorption - Not more than 1% on mass within 24 hours. (ix) Cold flexibility - Minimum (-) 20C. (x) Dimentional stability % change = Maximum 1%. (d) Over the membrane provide a finishing with solar reflective bitumen aluminium paint @ 0.10 Kg/Sqm as prescibed by manufacturer (Item for bitumen aluminium paint will be measured and paid separately as supplied only)
Supply only for applying one coat of solar reflective bituminous aluminium paint @ 0.10 Kg/Sqm over APP membrane for non accessible roof complete all as specified and directed.
M&L Preparation of old painted steel and iron surfaces of any description, not otherwise described, over 10 cm width or girth and applying One coat of synthetic enamel paint complete all as specified and directed.
Taking down existing aluminium joinery and windows of any description (frame/ shutters) with all fittings (but excluding grills) complete all as specified and directed.
S&F standard aluminium section powder coated (minimum thickness of powder coating shall be 50 micron and colour shall be as approved by GE ) as in frame, shutters for doors, window / ventilators, fixed / openable / sliding or in any pattern, cut to size, jointed with cadmium plated steel screws, including rubber beading or gaskets for fixing glass, provision of hinges, screws, plugs, handle, lock, roller, Nylon ball bearing etc complete all as specified and directed (Aluminium section shall be of make Jindal/Hindalco/ Indalco) Note:- Weight of Aluminium sections as per actual or as per IS or as per manufacturer, whichever is less, shall only be considered for payment. Cost of other items / accessories required for entire completion of the work shall be deemed to be included in the quoted rate. However glass panes and stain less steel wire cloth shall be measured and paid separately as supply only under respective item.
Supply only 4mm thick sheet glass, ordinary quality fixed in aluminium window along section all as specified and directed
Supply only Stainless steel wire cloth.0.36mm nominal dia of wireand average width of aperture 1.40mm and fixed with stainless steel wire staples in aluminium windows or along with 'F' section complete all as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for etc, complete all as specified and directed.
S&F bands, straps , supports or stays for rain water, ventilating pipes including bolts, clamps, hold fasts etc and similar small articles to Fe-410-0 or Fe-310-0 all as specified & directed.
S&F mild steel Framed work such as grills, gratings etc, with ends of bars shouldered or rebated or forged into spikes, framed guard bars, barred iron doors, railings, framework of water tanks and similar work conforming to Fe -290 Grade -E-165, complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified including dismantling of roof sheet any type complete all as specified and directed.
M&L two coats of synthetic enamel paint over a coat of red oxide primer over preparation of new steel surface complete all as specified.
Taking down existing aluminium grills from balcony/ any locations complete all as specified and directed.
S&F aluminium anodised Grills of approved design for window / ventilators and fixing with F/U channel including drilling as required in RCC sections in rectangular or architectual type balcony opening in existing building, complete all as specified and directed. Note: The Grills shall be of Model DG-100/DG-102 of Make Deco or equivalent make as approved by the GE.
M & L Rendering 15 mm thick on fair faces of brick work or concrete surfaces using CM 1:4, finished the surface even and smooth complete all as specified and as directed.
S&F cast iron covers and frame grade FG 150 unmachined as in manhole covers etc including locking arrangement,and removing old Unsv covers complete all as specified
M&L for Non - skid coloured Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed in CM (1:6) complete all as specified and directed.
M & L Cement Concrete Type D2 1:4:8 (40 mm graded aggregate) in subbase 75 mm thick complete all as specified and directed.
M&L Chequered cement concrete tiles 20cm x20cm x 25mm thick,set, jointed and pointed in neat cement slurry in floors with white cement and pigment over 15 mm thick screed bed in CM (1:6) complete all as specified and directed.
S&F in repairs angle valve/stop cock 15mm cast copper alloy with crutch or butterflty handle, screwed down screwed for iron pipe or for brass chromium plated with fancy type complete all as specified.
S&F for Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 35mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer- In- Charge.
S&F for wall mixer with provision for overhead shower with 115 mm long bend pipe on upper side, connecting legs and wall flanges. Make: ESS cat part No EC-10 or equivalent.
S&F for glass shelf assembly 200mm, fixed with brass screws and plugs.
S&F stainless steel electro polish of grade 304 as in kitchen trolley for modular kitchen consisting of cutlery cup / soucer, thali basket, drawers, plain basket, bottle pullout basket etc, complete all as specified and directed. NOTE: the design and specifications of the above item (including of materials) shall be got approved by the contractor from the GE before procurement
S&F for 30 mm Continuous (piano) hinges, mild steel, bright finish or electro galvanised complete all as specified and directed.
S&F 125 mm long cast type Aluminium anodised handles etc.complete all as specified.
Excavation in trenches, n.exc 1.5m wide and n.exc 1.5m in depth for sewage line and getting out in hard/ dense soil complete all as specified and directed.
M & L for cement concrete 1:4:8 type D2 (using 40 mm graded trap stone aggregate) as in foundations and mass concrete etc complete all as specified and directed.
M & L for plain cement concrete 1 : 3 :6 type C2 (using 40 mm graded aggregate) as in bed to drain pipe including packing under and haunching against the sides of pipes they are laid and tested for 100 mm bore pipe.
All as per item No. 121.00 above but for 150 mm bore pipe.
All as per item No.121.00 above but for 200 mm bore pipe.
M & L cement concrete 1:2:4 type B-1 (20 mm graded aggregate) as in channels in manholes and drain etc.
Extra for forming fair finished drain or channels 30 cm inner girth in cement concrete using extra cement including forms moulds mitred/stopped ends etc complete all as specified.
Demolition of brick work built in cement mortar including all quoins, arches, pillars etc & removal of debris out side MD land complete all as specified
M & L Brick work with sub class 'B' bricks straight or curved on plan exceeding 6 m mean radius built CM 1:4 complete all as specified.
M & L cement concrete 1:3:6 type C-1, (using 20 mm graded stone aggregate) as in coping including necessary form work complete all as specified and directed.
M & L for rendering 15 mm thick in CM 1:4 on fair faces of brick work or concrete surfaces, finished even or smooth without using extra cement mixed with WPC 2 % by weight of cement (WPC will be measured and paid separately).
Supply only intergal water proofing compound. (ISI Marked).
Demolition of reinforced cement concrete as in drain cover slab(Reinforcement cut to facilitate demolition) for any thickness and any specification complete all as specified and directed.
M & L for precast reinforced cement concrete 1:2:4 type B-1 (20mm graded agg) as in cover slab for manholes set in CM 1:4 including necessary form work complete all as specified and directed.
S&F TMT bars 10mm dia , cut to length, bent to shape required, and hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified.
Demolition and breaking up drain pipes (Salt glazed ware, AC or reinforced concrete) , 100 mm dia, set in cement mortar complete all as specified and directed.
All as per item No. 134.00 above, but 200 mm bore
M&L reinforced concrete pipes, class NP2, 150 mm bore, laid and jointed complete with collars complete all as specified and directed.
All as per item No. 136.00 above, but 200 mm bore
S&F for Polyethylene Septic tank of 10000 L capacity horizontal type, of diameter 1600mm, length 3200 mm, thickness 16mm, Nos of chamber 03, Nos of manholes 02,size of manholes 550mm (Dia) Dia of oultlet and inlet 160mm, air vent 50mm complete fixing incl necessary earthwork complete all as specified and directed.
Returning, Filling in including, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Removing excavated soil to a distance exc 250m and not exc 500m deposited where directed at a level n.exc 1.50m above the starting point.
M&L for ready mix plaster 05 mm thick on concrete surfaces as in ceiling including necessary scaffolding complete all as specified and as directed
S&F floor door stopper of 150mm long aluminium body complete all as specified and directed
SCHEDULE 'A' (E/M ITEMS) Taking down carefully point wiring of any type & pattern (Light/Fan/Socket or power) including fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings of any type etc and making good disturbed surfaces of walls/ roof etc, complete all as specified and directed.
Taking down complete main switches/ MCB DBs with enclosure and its components of any size and capacity ,etc complete all as specified and directed.
M & L for point wiring with PVC insulated FRLS unsheathed 1100 Volts grade single core multistranded copper conductor cable 1.5 Sqmm drawn in and including PVC concealed conduit of suitable size of wall/ RCC slab/ ceiling/ colunms/ beams etc with all accessories, fittings, PVC junction boxes etc, with suitabe sunk pressed steel boxes for modular fittings not less than 1.6 mm thick, including Modular cover plate of suitable size etc with necessary fixing accessories and earth continuity conductor cable of 1.5 Sqmm size connected to common earth and earth dolly including 1.6 mm thick pressed steel terminal boxes concealed in wall mounting switches / sockets / fan regulators fixed with Cadmium plated machine screws complete etc all as specified for one light / fan / bell point controlled by one switch. Note : 1. Two runs of cable, one run of earth wire, one run of PVC conduit will be measured and paid one unit.
All as per item No. 145.00 above but for one 6A 2pin/3pin socket out let multipurpose on the same board with other switches.
All as per item No. 145.00 above but for one 6A 2pin/3pin switch socket out let multipurpose on independent Board.
All as per item No. 145.00 above but wiring complete with 2.5 Sqmm for 3 pin 16A socket multipurpose on independent board inluding earth continuity conductor 2.5 Sqmm
S & F modular type 6A one way SP switch 1 module confirming to IS: 3854-1997 with finger proof terminal complete all as specified and directed.
S & F modular type 2/3 pin 6 Amps socket 2 module conforming to IS: 1293-2005 complete all as specified and directed.
S & F modular type 2/3 pin 16 Amps socket 2 module conforming to IS: 1293-2005 complete all as specified and directed.
S & F modular type 16 A one way SP switch 1 module confirming to IS: 3854-1997 with fingure proof terminal complete all as specified and directed.
S & F shuttered type RJ-11 1 module Telephone socket complete all as specified and directed.
S & F TV Co - axial socket 1 module complete all as specified and directed.
S & F in repairs modular type 120W step fan regulator of 2 module size conformng to IS: 11037-1984 complete all as specified and directed.
S & F in repairs Modular Bell push flush type 6 Amp, 1 module, 230 Volts complete all as specified and directed.
S & F in repairs bell ding dong AC 230 V single pole. complete all as specified and directed.
S & F Modular Blank plate 1 module suitable for Modular switch boards all as specified and as directed
S & F Modular cover plate 12 modules complete all as specified and directed.
S & F Modular cover plate 8 modules complete all as specified and directed.
S & F Modular cover plate 6 modules complete all as specified and directed.
S & F Modular cover plate 4 modules complete all as specified and directed.
S & F Modular cover plate 3 modules complete all as specified and directed.
S & F Modular cover plate 2 modules complete all as specified and directed.
S & F Modular cover plate 1 modules complete all as specified and directed.
S & F ceiling rose three terminal, 230 Volts PVC / Polycarbonate body duly ISI Marked complete all as specified and directed.
Supply and fix surface/wall mountain, indoor decorative type LED luminaire extruded alluminium batten in anodized finished with opal diffuser, with IP 20 protection of capacity 18/20W having luminious efficiency not less than 100 lumen/watt, CCT 6500K4 feet long operating on 230V, 50 Hz, AC supply including fixing and mountaining on PV block 02 Nos & connecting with 1.5 sqmm, 3 core PVC insulated copper conductor and suitable nuts bolts & washers complete all as specified and directed.” Make : Bajaj Model No BCLAV20W-LEDP, Halonix :- HLB-03-18-CW-AL-SQ-HL2, Jaquar :- LGLZU1X022XC. Note : The lowest tenderer shall furnish 3 years warranty certificate from OEM for luminiries including LM79 & LM80 test certificate from NABL certified laboratory
Supply and fixing in replacement of LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including provision with three core flexible copper conductor cable of suitable size and PVC square blocks complete all as specified and directed. Make : Bajaj (Model No –BCLSV-10W-WH), Jaquar (Model No – LGLZO10XC), Wipro, Halonix (Model No –HLB-07-10-CW-lP) Note : The lowest tenderer shall furnish 3 years warranty certificate from OEM for luminiries including LM79 & LM80 test certificate from NABL certified laboratory
S & F LED light fitting 1X10W Bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. Make : Bajaj (Model No-BIBWP10WLED), Jaquar (Model No –LBLK02X010XC), Wipro, Halonix (Model No –HLBH-21-10-CW) Note : The lowest tenderer shall furnish 3 years warranty certificate from OEM for luminiries including LM79 & LM80 test certificate from NABL certified laboratory
S & F Fancy jumbo batten holder metal ring, pin type Batten holder metal ring suitable for LED bulb of 9 Watt complete all as specified and directed.
S & F LED Light Bulb 9 watt, Pin type of white colour, 230 V complete all as specified and directed.
Supply and fix in repairs high speed Ceiling fans complete with aluminium blades, down rods, PVC Canopy and accessories, white in colour 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value min 6.00, BEE Five star rated with brushless direct current motor(BLDC) without remote complete including taking down old unserviceable fan to MES store all as directed by Engr-in-Charge. Make : Havells (Efficiencia Neo (BLDC 26 W) /Orient (FALCON 400) / Bajaj (ENERGOS 28) Note : Fan Regulator will be paid seperately under respective itme of BOQ and Unserviceable ceiling fans shall be deposit to MES store.
Supply & fix Wall mounting fan 400 mm sweep, operating on single phase ,230V,50Hz having Speed of not less than 1350 RPM, air delivery min 65cmm power output of min55W star rated along with blade, canopy, mounting brackets, rubber insulator. Make : USHA-USH-FW-40-3/Orient –Wall80/Crompton Gale Classic
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300 mm Sweep min 1350 RPM with blades, and frame and louvers complete all as specified and directed. Make : Bajaj-SKU-70069/Orient(Airflow)/Havells (FHVVEMTDSB12)
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250m complete all as specified and directed. Make : Crompton-ventilus/Orient Ventilator DX/Havells-FHVTADXWHT10
S&F modular type 3/5 pin socket with one single pole MCB 20 Amp 230 Volts complete all as specified including concealing in wall suitable for Geyser, AC and Domestic appliances complete all as specified and directed.
S & F MCB DB, 12 way, SPN, double door, 240 Volts and including cutting chases in wall, concealing DB in wall, making good the disturbed surfaces and making all connections complete all as specified and directed. Note: Quoted rate shall be deemed to include for provision of copper bus bar of 200 Amps rating.
S & F MCB SPN 40 Amps, 240 / 415 Volts, 'B' Series, 50 Hz, 10 KA Breaking capacity complete all as specified and directed.
S & F MCB SP 5 to 32 Amps, 240 / 415 Volts, 'B' Series, 50 Hz, 10 KA Breaking capacity complete all as specified and directed.
Supply and fix Rigid non-metallic PVC conduit exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc of size 20mm for Telephone and TV wire complete all as specified and directed.
S & F 20 pair telephone distribution box with suitable S.S frame for mounting tag module krone module and incorporated in 16 SWG box with Proper lockable cover. Note :- The box should be fixed on wall with suitable fasteners including painting & earthing, This also inlcudes fixing the cable, distribution chart sufficient space for the cables, wires etc complete all as specified and directed.
S & F for 2 pair telephone cable having solid electrolyte annealed bare copper conductor of 0.5 mm nominal diameter with high density polyethylene insulation paired, polyester taped nylon rip cord and grey colour sheathed with FR PVC conforming to ITD specification SWS 113 C including termination complete all as specified and directed.
S & F Co axial cable Electrolytic Grade solid annealed Copper conductor, Jelly Field, Aluminium Foiled and Aluminium wire Braided RG-6 with connectors used for Television complete all as specified and directed.
M&L for sub main wiring with two single core 6.0 Sqmm PVC insulated FRLS multistranded flexible copper conductor cable 660/1100 volts grade down in through non metalic PVC conduit duly concealed with and including PVC insulated 6.0 Sqm single core single strand copper conductor as continous earth wire in green colour connected to common earth dolly including taking down old unserviceable submain wiring complete all as specified and as directed. Note : 1. Two runs of cable, one run of earth wire, one run of PVC conduit duly concealed will be measured and paid one unit.
M&L for sub main wiring with two single core 4.0 Sqmm PVC insulated FRLS multistranded flexible copper conductor cable 660/1100 volts grade down in through non metalic PVC conduit duly concealed with and including PVC insulated 4.0 Sqm single core single strand copper conductor as continous earth wire in green colour connected to common earth dolly including taking down old unserviceable submain wiring complete all as specified and as directed. Note : 1. Two runs of cable, one run of earth wire, one run of PVC conduit duly concealed will be measured and paid one unit.
M&L for sub main wiring with two single core 1.5 Sqmm PVC insulated FRLS multistranded flexible copper conductor cable 660/1100 volts grade down in through non metalic PVC conduit duly concealed with and including PVC insulated 1.5 Sqmm single core single strand copper conductor as continous earth wire in green colour connected to common earth dolly including taking down old unserviceable submain wiring complete all as specified and as directed Note : 1. Two runs of cable, one run of earth wire, one run ofPVC conduit duly concealed will be measured and paid one unit.
S&F in repair/replacement of building Security light fitting 35 Watt made up of pressure die cast alluminium body with mid power LED as lighting sources and PC cover having Top opening separate driver compartment with IP66 protection and impact resistance of IK07 including fixing arrangements and taking down old rusted bracket fittings complete all as per directed by Engr- in – charge. Make : Bajaj, Jaguar-LULTU1SO36XC, Wipro, Halonix-HLFPS22S06-36-CW
M&L for earthing using GI earthing strip 32 x 6mm complete with galvanised steel earth plate electode 600mmx600mmx6mm thick buried directly in ground, earth pit not less than 2.25 meters deep below ground level connection to and including GI strip of size 32x6mm to the extend 7.5 mtr as earth lead by means of GI bolts, Nuts etc. with provision of charcoal and salt all as per electrical plate No 3 of SSR Part I including water arrangement with GI Pipe 20 MM dia (medium Grade), earth lead protection pipe 50mm madium grade with bends, elbow etc. from earth plate to test point, excavation and earth work returning, filling, ramming and removing of soil to distance not exc 50mtr, make good to match with existing surface making PCC pit (Earth chamber) having internal size 30cm x 30cm x 30cm and outer size 60cm x 60cm x 60cm with RCC reinforced cover 50mm thick with one lifting handle made of 8mm dia MS bar funnel wie mesh and testing on completion including making test point on wall as per SSR specification all as specified and directed.
Excavation in trenches not exceeding 1.50 m wide and n.exc 1.5 m in depth for foundation of poles, cable etc, not exc 10 sqm on plan and getting out in soft/loose soil including taking out brick protection etc complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick complete all as specified and directed.
Removing excavated materials (soils) not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed.
M & L for sand cushioning by spreading in trenches crushed sand by gently by punning down manually as in cable protection all as specified and as directed by Engineer -in-charge.
Supply and laying un-reinforced precast concrete cable cover class LV, type-I, flat size 250 mm x 150 mm x 40 mm laid in trenches all as specified.
Supply and Laying or fixing or passing through pipe, XLPE/PVC insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 25 Sqmm 4 core including necessary connection and providing cable lugs as required all as specified.
M&L for cutting existing road/hard standing not exc 45x45 cm in wide & depth getting out excavated material for laying GI tube ;returning filling & well rammaing watering finish suraface 10 cm from top using PCC 1:3:6; including removal of surplase soil all as directed by Engr-in-Charge..
S&F of HDPE pipe 100 mm dia, PN-10 for laying in ground, raod crossing etc for cable protection including necessary fittings, clamps for supports, etcall as directed by Engr-in-Charge.
S&F of HDPE pipe 75 mm dia, PN-10 for laying in ground, raod crossing etc for cable protection including necessary fittings, clamps for supports, etcall as directed by Engr-in-Charge.Make: Precision/Plasto/Supreme/Sudhakar
Parmatma Enterprises (BID ID -3121976)
Vishal Builders (BID ID -3121121)
M/s Shree Construction Co (BID ID -3122391)
Joy builders (BID ID -3121171)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .