Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1Accepted-AOC B 501 509 DYNASTY BUSINESS PARK ANDHERI KURLA ROAD ANDHERI EAST MUMBAI MAHARASHTRA 400059 | MUMBAI SUBURBAN | MAHARASHTRA | 400059 | ₹1 | L1 | Accepted-AOC L1 |
| 2 | Rejected-Technical 501 ARENA SPACE BEHIND MAJAS BUS DEPOT OFF J V LINK ROAD JOGESHWARI EAST MUMBAI MAHARASHTRA 400060 | MUMBAI SUBURBAN | MAHARASHTRA | 400060 | - | - | Rejected-Technical REJECTED |
| 3 | Rejected-Technical 135 139 BILAKHIA HOUSE MUKTANANAD MARG CHALA VALSAD GUJARAT 396191 | VALSAD | GUJARAT | 396191 | - | - | Rejected-Technical REJECTED |
| 4 | Rejected-Technical | - | - | Rejected-Technical REJECTED |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
23 May 2022, 12:00 pmClosed
THE DY. DIRECTOR OF HEALTH SERVICES (E AND S)
Central Medical Stores 141, A J C Bose Road, Kolkata - 700 014
RE E TENDER FOR PROCUREMENT OF ADDITIONAL CONSUMABLE ITEMS FOR TWO YEARS FROM THE DATE OF AWARD OF CONTRACT (AOC)
2022_HFW_378604_2
HST/1P-101-2019/ ADDLCON-RT(074)/2022/194
Open Tender
Equipments
Item Rate
730 days
KOLKATA
Please refer Tender documents.
3 documents required · 3 mandatory
₹1 L
Yes
7 Nov 2022
28 Apr 2022
23 May 2022
28 Apr 2022
23 May 2022
10 May 2022
Cemented Total Hip Replacement System with Accessories: Cemented THR System - Acetabular Cup size 40 to 62 made of Highly Cross-linked Polyethylene ( Range 7 – 10 MARD) , Stem made of forged CoCr, base diameter 4mm to 8mm, & "Internal Head" having minimum 5 nos offset. Total Instruments set for THR System should be on loaner basis. Certification : US FDA / CE certified from notified body.
Uncemented Total Hip Repalcement System : Uncemented Total Hip Replacement System Acetabular Cup size 40 to 62 made of titanium and having porous coating & Highly crosslink polyethylene liner, HA coated Stem base diameter 4mm to 8mm made of titanium, 28/32 mm SST/CoCr internal head, Total Instruments set for THR System. Instruments set should be on loaner basis. Certification : US FDA / CE certified from notified body.
Femoral component Metallurgy - CoCr (Cobalt Chromium Molybdenum ). Femur should have a deep trochlear grove. Femoral component with various A/P diameter & M/L diameter, with different polythickness . Titanium Anatomical Tibia with different M/L diameter & A/P diameter. Poly Insert metallurgy - highly cross linked 5-7.5 MRAD width different Insert thickness, Patella Thickness 9 mm. Instruments set should be on loaner basis. Certification : US FDA / CE certified from notified body.
Total Knee Replacement System with Zirconium Oxide femoral Component: Femoral component Metallurgy - Zirconium Oxide. Femur should have a deep trochlear grove. Femoral component with various A/P diameter & M/L diameter, with different polythickness . Titanium Anatomical Tibia with different M/L diameter & A/P diameter. Poly Insert metallurgy - highly cross linked 5-7.5 MRAD width different Insert thickness, Patella Thickness 9 mm. Instruments set should be on loaner basis. Certification : US FDA / CE certified from notified body.
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .