Repairing and Replacement of Slab on Gurgaon Canal Head 110.
2021_HRY_192602_1
6586-6614/25-A dt.13.10.21-Gurgaon Canal
Open Tender
Civil Works
Item-rate/Agreement basic
20 days
Palwal
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
₹1,870
14 Jan 2022
18 Oct 2021
26 Oct 2021
18 Oct 2021
25 Oct 2021
18 Oct 2021
Amount
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - incharge. (HSR item No.5.25)
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : (HSR item No.5.29)
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.(HSR item NO. 5.45)
Brick work with common burnt clay non-modular bricks of class designation 7.5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : Cement mortar 1:4 (HSR item No. 7.22.1)
12 mm cement plaster of mix : 1:3( 1 cement:3fine sand) (HSR item NO. 11.5.2)
Pointing on brick work or brick flooring with cement mortar 1:3 (1 cement : 3 fine sand): Flush/Ruled/Struck or weathered pointing HSR item NO. 11.25.1)
Centering and shuttering including strutting, propping etc. and removal of form for suspended floods, roofs, landings, balaconies (HSR item No. 6.30.3)
Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level (HSR No.6.33.1)
Copper wiring in PVC conduct (Surface/recess)Wiring for Light/Fan/call bell point in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group C (HSR item No. 23.3.1.3)
Wiring in PVC conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin socket and 1 no 5/6 Amp switch required MS Box etc complete as required Group A (HSR item No. 23.3.4.1)
Distempering with dry distemper of approved brand and manufacture (two or more coats) of required shade on new work, over and including water thinnable priming coat to give an even shade. (HSR item NO.11.63)
White washing with lime to give an even shade :New Work (three or more coats) (HSR item NO. 12.1.3)
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid separately). Kiln seasoned and chemically th reated Hollock wood (HSR no. 12.1.3)
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size). (HSR item NO. 12.6)
Providing and fixing panelled or panelled and glazed shutters for doors,windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) (HSR item NO. 12.7.2.1)
M.S. heavy weight butt hinges 100x75x3.5 mm IS: 1341 marked (HSR item no. B0861)
Reinforced cement concrete work in walls (any thickness),including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor four level, excluding cost of centering, shuttering, finishing and reinforcement : (HSR item NO. 6.15.1)
Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diametr.
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : (HSR item No. 9.17)
10 cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar mixed with bhusa @ 35 kg per cum of earth and gobri leaping with mix 1:1 (1 clay : 1 cow dung) and covered with flat tile bricks, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finished neat: (HSR item No. 9.11.1)
Lump Cost of Electricity Metre connection and Cable
The Tewatia Co-op. L&C Society Ltd.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .